Huawei FusionServer Pro V5 Rack Server Data Sheet
Huawei FusionServer Pro V5 Rack Server Data Sheet
Memory 24 DDR4 DIMM slots, 2933 MT/s; up to 12 Intel® Optane™ PMem modules (100 series), 2666 MT/s
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor for cache power-off protection; RAID-level migration, drive roaming, self-diagnosis,
RAID support
and web-based remote configuration
PCIe expansion Up to 5 PCIe 3.0 slots, including 1 for a RAID controller card and 1 for a flexible NIC
Fan modules 7 hot-swappable counter-rotating fan modules with support for N+1 redundancy
2 hot-swappable PSUs with support for 1+1 redundancy and the following configuration options:
• 550 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W AC Platinum PSUs
Power supply units
1000 W (input: 100 V to 127 V AC)
1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W 380 V HVDC PSUs (input: 260 V to 400 V DC)
• 1200 W -48 V to -60 V DC PSUs (input: -38.4 V to -72 V DC)
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features such as fault
diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0; provides a remote management interface based on HTML5/
Management VNC KVM; supports CD-free deployment and the Agentless feature, simplifying management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such
as stateless computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire-lifecycle
management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, VMware ESXi
Operating Systems
For details, visit https://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Security Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, and security front panel
Operating temperature 5ºC to 45ºC (41ºF to 113ºF), compliant with ASHRAE A3 and A4
Installation suite L-shaped guide rails, adjustable guide rails, and holding rails
Chassis with 3.5-inch hard drives: 43 mm x 447 mm x 748 mm (1.70 in. x 17.60 in. x 29.45 in.)
Dimensions (H x W x D)
Chassis with 2.5-inch hard drives: 43 mm x 447 mm x 708 mm (1.70 in. x 17.60 in. x 27.87 in.)
The Huawei FusionServer Pro 1288X V5 is a 1U 2-socket rack server that delivers high computing density. It is ideal for scenarios such as
cloud computing, virtualization, high-performance computing (HPC), and big data processing, improving space utilization for data centers.
The 1288X V5 supports 2 Intel® Xeon® Scalable processors in a 1U space, with 24 DDR4 DIMMs for memory and 8 x 2.5'' hard drives for local
storage. The 1288X V5 incorporates patented technologies, such as Dynamic Energy Management Technology (DEMT) and Fault Diagnosis
& Management (FDM), and is configurable with Huawei's FusionDirector software for full-lifecycle management, helping reduce OPEX and
improve ROI.
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor for cache power-off protection; RAID-level migration, drive roaming, self-diagnosis,
RAID support
and web-based remote configuration
PCIe expansion Up to 6 PCIe 3.0 slots, including 1 for RAID controller card and 2 for OCP 2.0 mezzanine cards
Heterogeneous 2 single-slot HHHL GPU heterogeneous accelerator cards. For details, visit
accelerator cards https://support.huawei.com/onlinetoolweb/ftca/indexEn?serise=2
2 hot-swappable PSUs supporting 1+1 redundancy and the following configuration options:
• 550 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
Power supply units
• 1500 W AC Platinum PSUs: 1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC); 1000 W (input: 100 V to 127 V AC)
• 1500 W 380 V HVDC PSUs (input: 260 V to 400 V DC)
• 1200 W -48 V to -60 V DC PSUs (input: -38.4 V to -72 V DC)
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features, including
fault diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces, such as Redfish, SNMP, and IPMI 2.0, provides a remote management interface based on HTML5/
Management VNC KVM, and supports CD-free deployment and the Agentless feature to simplify management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such
as stateless computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire-lifecycle
management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, and VMware ESXi
Operating Systems
For details, visit https://support.huawei.com/onlinetoolweb/ftca/indexEn?serise=2.
Security Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, and security front panel
Operating temperature 5ºC to 45ºC (41ºF to 113ºF), compliant with ASHRAE A3 and A4
Installation suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) Chassis with 2.5'' hard drives: 43 mm x 447 mm x 708 mm (1.70 in. x 17.60 in. x 29.45 in.)
The Huawei FusionServer Pro 2288H V5 is a 2U 2-socket rack server that supports various configurations and can be widely used in
scenarios such as cloud computing virtualization, databases, and big data. The server can be configured with two Intel® Xeon® Scalable
processors, 24 DDR4 DIMM slots, 10 PCIe slots, and large-capacity local storage resources.
It incorporates patented technologies such as Dynamic Energy Management Technology (DEMT) and Fault Diagnosis & Management (FDM),
and integrates Huawei's FusionDirector software for entire-lifecycle management, helping customers drive down OPEX and improve ROI.
Memory 24 DDR4 DIMM slots, 2933 MT/s; up to 12 Intel® Optane™ PMem modules (100 series), 2666 MT/s
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor for cache power-off protection; RAID-level migration, drive roaming, self-diagnosis,
RAID support
and web-based remote configuration
PCIe expansion Up to 10 PCIe 3.0 slots, including 1 for a RAID controller card and 1 for a flexible NIC.
Fan modules 4 hot-swappable counter-rotating fan modules with support for N+1 redundancy
2 hot-swappable PSUs with support for 1+1 redundancy and the following configuration options:
• 550 W AC Platinum PSUs (input:100 V to 240 VAC, or 192 V to 288 V DC)
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W AC Platinum PSUs
Power supply units
• 1000 W (input: 100 V to 127 V AC)
• 1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W 380 V HVDC PSUs (input: 260 V to 400 V DC)
• 1200 W -48 V to -60 V DC PSUs (input: -38.4 V to -72 V DC)
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features such as fault
diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0; provides a remote management interface based on HTML5/VNC
Management
KVM; supports CD-free deployment and the Agentless feature, simplifying management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such as stateless
computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire-lifecycle management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, VMware ESXi For details, visit
Operating Systems
https://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Security Power-on password, Administrator password, Trusted Platform Module (TPM), Security front panel
Operating
5ºC to 45ºC (41ºF to 113ºF), compliant with ASHRAE A3 and A4
temperature
Installation suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions Chassis with 3.5-inch hard drives: 86.1 mm x 447 mm x 748 mm (3.39 in. x 17.60 in. x 29.45 in.)
(H x W x D) Chassis with 2.5-inch hard drives: 86.1 mm x 447 mm x 708 mm (3.39 in. x 17.60 in. x 27.87 in.)
The Huawei FusionServer Pro 2288X V5 is a 2U 2-socket rack server that supports various configurations and can be widely applied to
scenarios such as cloud computing, virtualization, databases, and big data. It can be configured with 2 Intel® Xeon® Scalable processors,
24 DDR4 DIMMs, 11 PCIe slots, and large-capacity local storage resources.
The 2288X V5 incorporates patented technologies such as Dynamic Energy Management Technology (DEMT) and Fault Diagnosis &
Management (FDM), and is configurable with Huawei's FusionDirector software for full-lifecycle management, helping reduce OPEX and
improve ROI.
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor for cache power-off protection; RAID-level migration, drive roaming, self-diagnosis,
RAID support
and web-based remote configuration
PCIe expansion Up to 11 PCIe 3.0 slots, including 8 standard slots, 1 for RAID controller card, and 2 for OCP 2.0 mezzanine card
Heterogeneous
Supports 8 HHHL GPU or 2 FHFL GPU cards
accelerator cards
2 hot-swappable PSUs supporting 1+1 redundancy and the following configuration options:
• 550 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
Power supply units
• 1500 W AC Platinum PSUs: 1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC); 1000 W (input: 100 V to 127 V AC)
• 1500 W 380 V HVDC PSUs (input: 260 V to 400 V DC)
• 1200 W -48 V to -60 V DC PSUs (input: -38.4 V to -72 V DC)
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features, including
fault diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces, such as Redfish, SNMP, and IPMI 2.0, provides a remote management interface based on HTML5/
Management VNC KVM, and supports CD-free deployment and the Agentless feature to simplify management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such
as stateless computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire-lifecycle
management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, and VMware ESXi
Operating Systems
For details, visit https://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Security features Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, security front panel, and out-of-box intrusion alarm
Operating temperature 5°C to 45°C (41°F to 113°F), compliant with ASHRAE A3 and A4
Installation suite L-shaped guide rails, adjustable guide rails, and holding rails
Chassis with 3.5'' hard drives: 86.1 mm x 447 mm x 748 mm (3.39 in. x 17.60 in. x 29.45 in.)
Dimensions (H x W x D)
Chassis with 2.5'' hard drives: 86.1 mm x 447 mm x 708 mm (3.39 in. x 17.60 in. x 27.87 in.)
The Huawei FusionServer Pro 2298 V5 is a 2U 2-socket rack server that supports various configurations and can be widely applied to
scenarios such as cloud computing, virtualization, databases, and big data. It can be configured with 2 Intel® Xeon® Scalable processors,
12 DDR4 DIMMs, 4 PCIe slots, and large-capacity local storage resources.
The 2298 V5 incorporates patented technologies such as Dynamic Energy Management Technology (DEMT) and Fault Diagnosis &
Management (FDM), and is configurable with Huawei's FusionDirector software for full-lifecycle management, helping reduce OPEX and
improve ROI.
1 or 2 1st Generation Intel® Xeon® Scalable processors (3100/4100/5100/6100/8100 series), 205 W thermal design power (TDP)
Processors
1 or 2 2nd Generation Intel® Xeon® Scalable processors (3200/4200/5200/6200/8200 series), 205 W TDP
RAID 0 or 1.
RAID support Configured with a supercapacitor for cache power-off protection, and supports RAID-level migration, drive roaming, self-diagnosis, and
web-based remote configuration.
2 hot-swappable PSUs supporting 1+1 redundancy and the following configuration options:
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
Power supply units • 1500 W AC Platinum PSUs: 1000 W (input: 100 V to 127 V AC); 1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W 380 V HVDC PSUs (input: 260 V to 400 V DC)
• 1200 W -48 V to -60 V DC PSUs (input: -38.4 V to -72 V DC)
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features, including
fault diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces, such as Redfish, SNMP, and IPMI 2.0, provides a remote management interface based on HTML5/
Management VNC KVM, and supports CD-free deployment and the Agentless feature to simplify management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such
as stateless computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire-lifecycle
management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, and VMware ESXi. For
Operating Systems
details, visit https://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Security features Power-on password, administrator password, and Trusted Platform Module (TPM) 2.0
Operating temperature 5°C to 35°C (41°F to 113°F), compliant with ASHRAE A3 and A4
2488 V5 2488H V5
Form factor 2U rack server
32 DDR4 DIMM slots, 2933 MT/s; up to 8 Intel® Optane™ PMem 48 DDR4 DIMM slots, 2933MT/s; up to 24 Intel® Optane™ PMem
Memory
modules (100 series), 2666 MT/s modules (100 series), 2666 MT/s
Supports hot-swappable hard drives with the following Supports hot-swappable hard drives with the following
configuration options: configuration options:
• 8 x 2.5-inch SAS/SATA hard drives • 8 x 2.5-inch SAS/SATA hard drives
• 25 x 2.5-inch SAS/SATA hard drives • 25 x 2.5-inch SAS/SATA hard drives
• 8 x 2.5-inch NVMe SSDs and 16 x 2.5-inch SAS/SATA • 24 x 2.5-inch SAS/SATA hard drives
Internal storage
hard drives • 8 x 2.5-inch NVMe SSDs and 16 x 2.5-inch SAS/SATA
Flash storage: hard drives
• 2 M.2 SSDs • 24 x 2.5-inch NVMe SSDs
Flash storage:
• 2 M.2 SSDs
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor for cache power-off protection; RAID-level migration, drive roaming, self-
RAID support
diagnosis, and web-based remote configuration
Fan modules 4 hot-swappable fan modules, providing protection against single-fan failures
2 hot-swappable PSUs, with support for 1+1 redundancy. The following PSUs are supported:
• 2000 W AC Platinum PSUs
1800 W (input: 200 V to 220 V AC, or 192 V to 200 V DC)
2000 W (input: 200 V to 240 V AC, or 200 V to 288 V DC)
Power supply units • 1500 W AC Platinum PSUs
1000 W (input: 100 V to 127 V AC)
1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
• 900 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 1200 W DC PSUs (input: -38.4 V to -72 V DC)
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features such as fault
diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0; provides a remote management interface based on HTML5/
Management VNC KVM; supports CD-free deployment and the Agentless feature, simplifying management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such
as stateless computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire-lifecycle
management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, VMware ESXi
Operating Systems
For details, visit https://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Security Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, secure startup, and security front panel
Operating temperature 5°C to 45°C (41°F to 113°F), compliant with ASHRAE Classes A3 and A4
Installation suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) 86.1 mm x 447 mm x 748 mm (3.39 in. x 17.60 in. x 29.45 in.)
• 2 Intel® Xeon® Scalable processors in 4U space, with 24 DDR4 DIMMs Offers ultra-large storage capacities,
• Up to 44 3.5-inch hard drives for local storage, or 4/8 NVMe SSDs which is ideal for hot, warm, and cold
• 2 10GE and 2 GE LOM ports, and 10 PCIe expansion slots data tiered storage in scenarios such as
• Leverages intelligent energy saving to improve performance per watt by 15%; combines Content Delivery Network (CDN), video
intelligent management features to enable up to 93% accuracy for fault locating cloud, and massive data archiving.
Memory 24 DDR4 DIMM slots, 2933 MT/s; up to 12 Intel® Optane™ PMem modules (100 series), 2666 MT/s
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor for cache power-off protection; RAID-level migration, drive roaming, self-
RAID
diagnosis, and web-based remote configuration
PCIe Expansion Up to 10 PCIe 3.0 slots, including 1 for a RAID controller card and 1 for a flexible NIC
Fan Modules 4 hot-swappable counter-rotating fan modules with optional N+1 redundancy
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features such as fault
diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0; provides a remote management interface based on HTML5/
Management VNC KVM; supports CD-free deployment and the Agentless feature, simplifying management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such
as stateless computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire-lifecycle
management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, VMware ESXi
Operating Systems
For details, see https://support.huawei.com/onlinetoolsweb/ftca/index?serise=2.
Security Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, and security front panel
Installation Suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) 175 mm x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.)
• 2 Intel® Xeon® Scalable processors in 4U space, with 24 DDR4 DIMMs Offers ultra-large storage capacities,
• Up to 38 3.5-inch hard drives for local storage, or 4 NVMe SSDs which is ideal for hot, warm, and cold
• 2 10GE LOM ports, and 11 PCIe expansion slots data tiered storage in scenarios such as
• Leverages intelligent energy saving to improve performance per watt by 15%; combines Content Delivery Network (CDN), video
intelligent management features to enable up to 93% accuracy for fault locating cloud, and massive data archiving.
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor to protect cache data from power failures; RAID level migration, drive roaming,
RAID
self-diagnosis, and web-based remote configuration
PCIe Expansion Up to 11 PCIe 3.0 slots, including 1 for a RAID controller card and 2 for OCP 2.0 standard NICs
Fan Modules 4 hot-swappable counter-rotating fan modules with optional N+1 redundancy
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features such as fault
diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0; provides a remote management interface based on HTML5/
Management VNC KVM; supports CD-free deployment and the Agentless feature, simplifying management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such
as stateless computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire- lifecycle
management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, VMware ESXi For details,
Operating Systems
see https://support.huawei.com/onlinetoolsweb/ftca/index?serise=2.
Security Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, and security front panel
Certification CCC
Installation Suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) 175 mm x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.)
Memory 48 DDR4 DIMM slots, 2933 MT/s; up to 24 Intel® Optane™ PMem modules (100 series), 2666 MT/s
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor for cache power-off protection; RAID-level migration, drive roaming, self-
RAID
diagnosis, and web-based remote configuration
Fan Modules 5 hot-swappable counter-rotating fan modules with optional N+1 redundancy
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features such as fault
diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0; provides a remote management interface based on HTML5/
Management VNC KVM; supports CD-free deployment and the Agentless feature, simplifying management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such
as stateless computing, batch OS deployment, and automated firmware upgrade, enabling smart and automatic entire- lifecycle
management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, VMware ESXi
Operating Systems
For details, visit https://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Security Power-on password, administrator password, Trusted Platform Module (TPM) 2.0, and security front panel
Installation Suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) 175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10 in.)
Huawei FusionServer Pro 2488H V6 is the next-generation 2U 4-socket (4S) rack server, ideal for computing-intensive scenarios such as
cloud computing, virtualization, high-performance computing (HPC), database, and SAP HANA. In virtualization scenarios, the OPEX of one
FusionServer Pro 2488H V6 is lower than that of two 2U 2S rack servers. The 2488H V6 houses four 3rd Gen Intel® Xeon® Scalable processors
in a 2U space, and supports 48 DDR4 DIMMs, 11 PCIe slots, and up to 25 x 2.5'' drives for local storage. It incorporates patented technologies
such as Dynamic Energy Management Technology (DEMT) and Fault Diagnosis & Management (FDM), and can be configured with Huawei
FusionDirector software for entire-lifecycle management, helping drive down OPEX and improve ROI.
Processors 2 or 4 x 3rd Gen Intel® Xeon® Scalable processors (5300/6300/8300 series), TDP up to 250 W
Memory 48 DDR4 DIMM slots, up to 3200 MT/s; up to 24 Intel® Optane™ PMem modules (200 series), 2666 MT/s
RAID 0, 1, 1E, 5, 50, 6, or 60; optional supercapacitor for cache power-off protection; RAID-level migration, drive roaming, self-diagnosis,
RAID
and web-based remote configuration
LOM network port 1 x OCP 3.0 NIC (optional): 2 x GE/10GE/25GE/100GE ports, supporting hot swap, NC-SI, WOL, and PXE
PCIe expansion Up to 11 PCIe 3.0 slots, including one dedicated PCIe slot for the OCP 3.0 NIC
Heterogeneous 2 dual-slot FHFL or 4 single-slot HHHL GPU heterogeneous accelerator cards. For details, visit
accelerator card https://support-it.huawei.com/ftca/indexEn?serise=2
2 hot-swappable PSUs with support for 1+1 redundancy and the following configuration options:
• 3000 W AC Titanium PSUs
2500 W (input: 200 V to 220 V AC)
2900 W (input: 220 V to 230 V AC)
3000 W (input: 230 V to 240 V AC)
• 2000 W AC Platinum PSUs
Power supply unit (PSU)
1800 W (input: 200 V to 220 V AC, or 192 V to 200 V DC)
2000 W (input: 220 V to 240 V AC, or 200 V to 288 V DC)
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W HVDC PSUs (input: 260 V to 400 V DC, or 200V to 277 V AC )
• 2200 W DC PSUs (input: -38.4 V to -72 V DC)
• 1200 W DC PSUs (input: -38.4 V to -72 V DC)
• Huawei iBMC integrates one dedicated management GE network port to provide comprehensive management features such as fault
diagnosis, automated O&M, and hardware security hardening.
• iBMC supports standard interfaces such as Redfish, SNMP, and IPMI 2.0; provides a remote management interface based on HTML5/
Management
VNC KVM; supports CD-free deployment and the Agentless feature for smart and simplified management.
• (Optional) Configured with the Huawei FusionDirector management software to provide advanced management features such as
stateless computing, batch OS deployment, and automated firmware upgrade, enabling automatic entire-lifecycle management.
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, and VMware ESXi.
Operating system (OS)
For details, visit https://support-it.huawei.com/ftca/indexEn?serise=2.
Security Power-on password, administrator password, TCM/TPM 2.0, security front panel, and out-of-box intrusion alarm, etc.
Operating temperature 5°C to 40°C (41°F to 104°F), compliant with ASHRAE Classes A3
Installation suite Adjustable guide rails, holding rails, and cable management arms (CMAs)
Dimensions (H x W x D) Chassis: 86.1 mm x 447 mm x 790 mm (3.39 in. x 17.60 in. x 31.10 in.)
Note:
1
The configuration of 24 NVMe SSDs is expected to be released in Q4 2020.