Dotech Sensing & Control
Dotech Sensing & Control
Dotech Sensing & Control
SENSETE°CH®
SECTION V. DOTECH SENSING & CONTROL CATALOGUE
CWC
A. FX Series
HEAT-EDGE®
Digital Temperature Controller ................................................................................................................................................................................................................................................................................ V-A1
Digital Humidity Controller ............................................................................................................................................................................................................................................................................................ V-A2
Refrigeration Controller .................................................................................................................................................................................................................................................................................................... V-A3
Multi-function Digital Controller .............................................................................................................................................................................................................................................................................. V-A5
B. DX Series
RAINBOW
HVAC Controller ...................................................................................................................................................................................................................................................................................................................... V-B6
Screw Compressor Controller ................................................................................................................................................................................................................................................................................... V-B7
Multi Compressor Controller ....................................................................................................................................................................................................................................................................................... V-B9
Geothermy Heat Pump Controller ........................................................................................................................................................................................................................................................................ V-B10
Air-Source Heat Pump Controller .......................................................................................................................................................................................................................................................................... V-B11
DOTECH
HTX Series
Economical Module Type Temperature And Humidity Sensor ............................................................................................................................................................................................ V-C12
OEM Temperature and Humidity Sensor ...................................................................................................................................................................................................................................................... V-C12
Ultra-recise Indoor Type Temperature And Humidity Transmitter ....................................................................................................................................................................................... V-C13
Analog Voltage Relative Humidity Module .............................................................................................................................................................................................................................................. V-C13
SHIMADEN
PR ELECTRONICS
KIMO
OHKURA
SEKONIC
HUBA
KAISE
CORDEX
FRIED ELECTRIC
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
SENSETE°CH®
FX Series
CWC
DIGITAL TEMPERATURE CONTROLLER
FX3S Digital Temperature Controller
FX3D Digital Temperature Controller NTC Heating Cooling Defrost 4~20mA RS485 Retrans
HEAT-EDGE®
NTC Heating Cooling Thermostat Defrost
RAINBOW
OUT1 Heating/cooling
: output 4~20mA 4~20mA
OUT2 Heating/cooling
: ouput signal input wiring method
for loop power sensor
out1 : heating/cooling output - Timer output
DOTECH
- Sensor error detection
alarm output
- Heater defrost output
- Hot gas defrost output
Heating/cooling output, precise temperature control, sensor Heating/cooling output, independent timer output, high/low alarm
Main- correction, sensor detection, data backup, min. on/off maintaining Main- output, defrost output, precise temperature control, sensor correction,
Function time setup, auto-output operation cycle settable in case of sensor Function sensor error detection, data backup, min. on/off maintaining time setup,
SHIMADEN
error RS485 communication (MODBUS), auto-output operation cycle
settable in case of error, transmission output
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Input/output Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)
Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)
PR ELECTRONICS
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C) Input/output 4~20mA Input : 1 point (including power supply)
Sensor Spec DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C)
Models FX3S-00 : Basic model (with DPR-TH1-ET temperature sensor) Sensor Spec DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
KIMO
Models FX3D - R2 : Add on RS232 communication
FX3D - A1R4 : Add on 4~20mA transmission output,
RS485 communication (MODBUS)
OHKURA
FX3FS-00
16A, 250Vac
n1 n2 n3
POWER
SEKONIC
L1 L2 COM B1 B2
c
1 2 4 5 6 8 9 10
AC100-240V ~ OUT NTC
50/60Hz
T1 T2
Main- Heating/cooling output, precise temperature control, sensor correction, Main- Heating/cooling output, high/low alarm output, precise temperature
sensor error detection, data back up, min. on/off maintaining time control, sensor correction, sensor error detection, data backup
Function setup, defrost output, virtual input function, function to prevent Function min. on/off maintaining time setup, transmission output, RS485
incorrect operation caused by sensor error communication (MODBUS)
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
CORDEX
Input/output Relay output : 1point (16A), Temp. sensor input : 1 point (NTC) Input/output Relay output : 3point (10A), Temp. sensor input : 1 point (thermo-couple)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C) Sensor Spec Thermo-couple K type : Measuring range : 0~1000°C
Sensor Spec DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
Models FX3S - 00 : Basic model (with 2 pcs ofDPR-TH1-ET temperature sensor)
Models FX3S - 00 : Basic model (with 2 pcs ofDPR-TH1-ET temperature sensor)
FRIED ELECTRIC
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-A1
SENSETE°CH®
FX Series
CWC
communication (MODBUS)
n1 n2 n3 n4
MODULE
OPTION
OUT1 OUT1 OUT2
POWER POWER
SEKONIC
1 2 4 5 6 9 10 11 1 2 3 4 5 6 7 8 9 10 11
R R
AC100 - 240V ~ W(Y) AC100 - 240V ~ W(Y)
% Humidity 50/60Hz TEMP % Humidity
50/60Hz
B B
OUT1 : Humidifica on/dehumidifica on
OUT1: Dehumidifica on/Humidifica on #1 ON/OFF output
#1 ON/OFF output OUT2 : Humidifica on/dehumidifica on
COM : Signal input common terminal #2 ON/OFF output
HUBA
Function sensor error occurs, sensor correction, sensor error detection, Function
detection, relay output manual control, transmission output, RS485
selection of displaying decimal point communication (MODBUS)
Power Supply AC100~240V, 50/60Hz, Max. 4VA Power Supply AC100~240V, 50/60Hz, Max. 4VA
Input/output Relay output : 1 point (out1 : 250Vac/16A), Input/output Relay output : 1 point (out1 : 250Vac/8(2)A),
CORDEX
Sensor Spec HTX20-FTS-502 (Voltage output type humidity sensor), HTX3515 Sensor Spec HTX20-FTS-502 (Voltage output type humidity sensor), HTX3515
Models FX3H - 00 Models FX3H - 00 : Basic model
FX3DH - R4 : Add on RS485 communication (MODBUS)
FRIED ELECTRIC
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-A2
SENSETE°CH®
FX Series
CWC
REFRIGERATION CONTROLLER
FX32J FX32R NTC RS485
HEAT-EDGE®
Showcase & Coldroom Controller NTC RS485 4~20mA Retrans Showcase & Coldroom Controller
RAINBOW
comp: compressor(SOL) control output ID1-D.SYC: defros ng syncroniza on signal input
fan: fan control outout ID2-I.LOCK: interlock signal input
def: defros ng control output ID3-FAN.AL: fan alarm signal input
DOTECH
al/aux: alarm/defros ng synchroniza on/ ID4-EMG.C: emergency(locking) switch signal input
hea ng control output ID5-NIGHT: NIGHT SETBACK signal input
ID6-DOOR: door open switch signal input
AMB.T : inside temperature sensor ID7-REMOTE remote
: opera on stop signal input
DEF.T : sensor for return temperature a er comp: compressor(SOL) control output
B1-AMB : inside temperature sensor
sensor for defrost recovery fan: fan control outout
B2-DEF :sensor for return temperature a er
def: defros ng control output
sensor for defrost recovery
al/aux: alarm/defros ng synchroniza on/
SHIMADEN
B3-EXT : outlet temperature sensor
hea ng control output
Defrosting (auto/manual), fan control, efcient delay Defrosting (auto/manual), defrosting stop delay, evaporation fan
Main- Room temperature sensor : 1EA, defrost recovery sensor : 1EA. Main- control, air inlet/outlet sensor : 2EA, defrost recovery sensor : 1EA,
Function High (low) temp. alarm output, room temp. transmission output Function virtual temp. sensor computing, door open alarm, emergency call,
(4~20mA), RS85 communication (MODBUS) interlock, defrost activation, night operation, high (low) temp. alarm
PR ELECTRONICS
output, RS85 communication (MODBUS)
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Input/output Relay output : 4point, Temp. sensor input : 2 point Power Supply AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)
Sensor Spec DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) Relay output : 4point, Digital input : 7 point,
Input/output Temp. sensor input : 3 point
FX32J – 00 : Basic model
FX32J– R4 : Add on RS485 communication (MODBUS) FX32R– 00 : Basic model
Models FX32J– A1 : Add on 4~20mA transmission output Models
KIMO
FX32R– R4 : Add on RS485 communication (MODBUS)
FX32J– L1 : adopted printer for recoder
FX32J– L2 : added data logger function
FXP-60 recording
: printer for FX32J-L1
OHKURA
Defrost factor Controller Defrost 4~20mA RS485
SEKONIC
B1 : Ambient humidity 4~20mA input
ID1 : OCR comp : COMP RUN/STOP
B2 : Ambient temperature sensor input
ID2 : INT sol : SOL V/V ON/STOP
B3 :Refrigerant suc on temperature
ID3 : HPS inj : INJECTION SOL
HUBA
sensor input
ID4 : OPS / PMR al/aux : Alarm
ID1 : Interlock signal
ID5 : LPS
def : Defrost ON/OFF output ID6 : INTERLOCK B1 : AMBIENT TEMP
al/aux : Alarm output ID7 : RUN/STOP B2 : SPARE
B3 : DISCHARGE GAS TEMP
Efcient defrosting in geothermy heat pump system Total control and detection (protection) for freezers, function of start,
KAISE
Main- Defrosting execution by measuring of ambient humidity Main- restart, pump down, alarm delay timer, discharge gas detection
Function and temperature Function (high & low temp.), individual alarm message (OC, HP, LP, OP, INT, etc),
liquid injection (discharge gas detection), communication (RS485 MODBUS)
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals Power Supply AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)
Input/output Relay output : 4point, Temp. sensor input : 2 point Input/output Relay output : 4point, Temp. sensor input : 2 point
CORDEX
Relay output : 2 point, Digital input : 1 point, Relay output : 4 point, Digital input : 7 point,
Sensor Spec Temp. sensor input : 2(3) point, humidity sensor input : 1 point Sensor Spec Temp. sensor input : 3 point
FX32K–00 : Basic model FX32C–00 : Basic model
Models FX32K–30 : Add on humidity sensor Models FX32C–30-R4 : Add on RS485 communication (MODBUS)
FRIED ELECTRIC
FX32K–30-R4 : Add on RS485 communication (MODBUS) FX32C–30 : add on gas discharge protection and control
FX32C–40 :add on added gas discharge temperature and inside
temperature control function
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-A3
SENSETE°CH®
FX Series
CWC
REFRIGERATION CONTROLLER
FX32PR FX32EV Electronic Expansion Valve control system
HEAT-EDGE®
Digital Low/High Pressure Controller 4~20mA RS485 Retrans Pt1000 4~20mA RS485 Retrans
FX32EV
MODULE
OPTION
Alarm
EVout
RAINBOW
1 2 3 4 5 6 7 8 9 10 11
AC100 - 240V ~
50/60Hz
EV
1 1 1
2 TRX 2 RXD 2 4~20mA
3 TRX 3 TXD 3 4~20mA
4 SG 4 GND 4 SG
SHIMADEN
Uniform step control, operation with intelligent shift PID degree of superheat control through defense and safety
Main- high/low alarm output, sensor correction, sensor error detection, Main- compensation, degree of superheat control for various refrigerant,
Function transmission output, communication (RS485 MODBUS) Function PMW (opening ratios control), remote operation, transmission output,
RS485 communication (MODBUS)
Power Supply AC100~240V, 50/60Hz, Max. 4VA Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
PR ELECTRONICS
Input/output One sensor input of 4~20 mA (embedded sensor loop power), Input/output SSR output 1-point (expansion valve on/off), relay output 1-point
Four relays (three relays for step control, one relay for alarm output) (alarm point), temperature sensor 1-point, 4~20mA pressure sensor
input 1-point (embedded sensor loop power)
FX32PR–00 : Basic model Sensor Spec Temp. sensor (DPR-PT1K-P6D5OL, -100~100°C
Models FX32PR–R4 : Add on RS485 communication (MODBUS) Pressure sensor (-1~9 bar or 0~30 bar)
FX32PR–A1 : Add on 4~20mA transmission output
FX32EV– 00 : Basic model
Models
FX32EV– R4 : Add on RS485 communication (MODBUS)
KIMO
connection
B3-EXT
B2-DEF
B1-AMB
14 8 14 8
7 12 7 12 Defrost - 8A - - 8A 8A
G G J1 G G J1
DEF
G + G - G + G -
Eva Fans - - - 8A 8A 8A
KAISE
B2-DEF
B1-AMB
B3-EXT
B2-DEF
B1-AMB
Room Temp. ● ● ● ● ● ●
14 8 14 8
7 12 7 12
G G G G
FAN
J1 FAN DEF
J1 Defrost Temp. - ● ● ● ● ●
G + G - G + G -
CORDEX
B2-DEF
B1-AMB
B3-EXT
B2-DEF
B1-AMB
RTC - - - - - -
14 8 14 8
ALARM ALARM
G G
7
J1
12
G G
7
J1
12
RS485 ◎ ◎ ◎ ◎ ◎ ◎
FRIED ELECTRIC
FAN DEF
G + G - G + G -
7 1 RS485, MODBUS FX iview
7 1 RS485, MODBUS FX iview ● : Basic
J2 J2 ◎ : Option
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-A4
SENSETE°CH®
FX Series
CWC
MULTI-FUNCTION DIGITAL CONTROLLER
FX32P FX32F
HEAT-EDGE®
Pressure Switch Controller 4~20mA RS485 Retrans Fan Coil Unit Controller NTC Heating Cooling RS485
MODULE
OPTION
N3,4 : 5A, 250V 2A 250Vac
AMB. TEMP
3wire
COIL TEMP
MODULE
OPTION
SENSOR
SENSOR
2wire
POWER
RAINBOW
L1 L2 COM mA +12V
c L1 L2 B2 G B1 G
1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 12 13
LO MD HI COM
+ AMB
AC100 - 240V~ B/T
SENSOR TEMP
50/60Hz AC100-240V~
N1 N2 N3 N4 50/60Hz FAN
L1
L2 LO : low wind speed on/off output
N1 :decrease pressure / increase pressure MD : midium wind speed on/off output
HI : high wind speed on/off output
DOTECH
#1 ON/OFF output, event output
N2 :decrease pressure / increase pressure
#2 ON/OFF output, event output G : signal input common terminal
N3 :decrease pressure / increase pressure B1 : Ambient temperature sensor input
#3 ON/OFF output, event output B2 : coil temerature sensor input
N4 :decrease pressure / increase pressure
#4 ON/OFF output, event output
SHIMADEN
Output controllable based on measured pressure value (increase and decrease), 3 stage fan speed controllable, 4 kind (stop/high/middle/low) airow choosable,
Main- Main- unication of temp. control function, data backup, self diagnostic, RS485
alternative operation available between freezing exclusive model and booster,
Function pump unit control exclusive model, RS485 communication (MODBUS) Function communication (MODBUS)
PR ELECTRONICS
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals Power Supply AC100~240V, 50/60Hz, Max. 4VA, connector
Input/output relay output : 4 point, Input sensor : 1 point (including power supply) Input/output relay output : 3 point (airow control),
Temp. sensor input : 2 point (room & water)
Sensor Spec 4~20mA (2 wire or 3 wire)
FX32P– 00 : Basic model Sensor Spec DPR-TH1 : NTC 5k, ±0.3°C at 25°C (-50°C~105°C)
Models FX32P– R4 : Add on RS485 communication (MODBUS) FX32F– 00 : Basic model
FX32P– A1 : Add on 4~20mA transmission output
KIMO
Models FX32F– R4 : Add on RS485 communication (MODBUS)
OHKURA
FX32A-351
MODULE
OPTION
3A 250Vac
SEKONIC
L1 L2 ID1 B3 B2 COM B1 +VDC
C1 C2 C
1 2 3 4 5 6 7 8 9 10 11
AC100 - 24 0V ~
50/60Hz
L1
comp : main motor on/off output L2
sol : LOAD SOL ON/OFF output B1 : pressure sensor input signal ID1 : remote run/stop signal
ID1 : control output interlock signal(OCR, EMSW) B1 : pressure sensor input signal B2 : COMP1 temp. sensor input signal C1 : COMP1 motor ON/OFF output
HUBA
ID2 : remote run / stop control signal B2 : temperature sensor input signal B3 : COMP2 temp. sensor input signal C2 : COMP2 motor ON/OFF output
Embedded run/stop switch, motor on/off, load run, auto-stop, manual Embedded run/stop switch, motor on/off, load run, auto-stop, manual
Main- stop, operation delay, load delay, embedded timer, Main- stop, operation delay, load delay, embedded timer,
Function pressure/temerature high level, temperature low level (standby for Function pressure/temerature high level, temperature low level (standby for
starting), interlock input signal (emergency switch, OCR reverse phase), starting), interlock input signal (emergency switch, OCR reverse phase),
KAISE
Usable thermometer and manometer, RS485 communication Usable thermometer and manometer, RS485 communication(MODBUS)
(MODBUS)
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Input/output Relay output : 2 point (motor, SOL)
Input/output Relay output : 2 point (motor, SOL) Digital input : 2 point (interlock, remote control)
Temp. sensor input : 1 point (discharge air temperature)
CORDEX
Models FX32A– R4 : Add on RS485 communication (MODBUS) Models FX32A-351-R4 : Add on RS485 communication (MODBUS)
FX32A– A1 : Add on 4~20mA transmission output FX32A-351-A1 : Add on 4~20mA transmission output
FX32A– R2 : Add on RS232 communication FX32A-351-R2 : Add on RS232 communication
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-A5
SENSETE°CH®
DX Series
CWC
DX100 series based on microprocessor has realized the best control and stability with efcient
control for HVAC units (AHU, constant temperature & humidity unit and control (dehumidier) and
perfect interface with safety devices. Its elegant graphic LCD display and LED helps users to check
RAINBOW
- Prevention from frequent starting failure occurred by low pressure hunting using
low pressure switch in compressor
- Successive starting function, pump down function and prevention from restarting
function
- Control function for cold water, hot water, steam valve, SCR, damper designed for
HVAC (4~20mA PID control)
SHIMADEN
- DX100 : HVAC Controller (2Comp) - DX120 : HVAC Controller (4Comp) - DX140 : Exclusive controller for constant temp. and humidity unit
PR ELECTRONICS
Models Models
DX120 DX140 DX100 DX120 DX140
Main Specication Main Specication
Digital Input Port 10 10 Trip / Alarm Recording Function OK -
Digital Output Port 12 12 Schedule Run/Stop Function OK -
KIMO
Temperature Sensor Input 2 1 Cool / Dehumidify Analog Control OK (PID control) OK(P control)
Humidity Sensor Input 1 1 Cooling Analog Control OK (PID control) OK(P control)
Diff. Pressure Sensor Input 1 - Heating Analog Control OK (PID control) OK(P control)
Refrigerator Compressor Control Step 2 4 2 Humidify Analog Control OK (PID control) OK(P control)
OHKURA
Heater Control Step 7 5 Diff. Pressure Analog Control OK (PID control) OK(P control)
Humidify Control Step 4 2 Temperature Retransmission Output OK -
Dehumidify Control Step 4 - Humidify Retransmission Output OK -
Main Brower Fan on/off Control 1 1 Diff. Press. Retransmission Output OK -
- React Heater SCR on/off Control OK -
SEKONIC
RUN INFO
OPERATION
Digital Output State CM1SL1 CM2SL2 H1 H2 H3 H4 H5 HUD ALR BRO 08:20 Current Time SCHEDULE
TRIP LOG
Opera on State LOC STP DPS. ALARM Alarm Message TRIP LOG
00 080102 15:55 FIRST POWER ON
01 080102 16:10 FAN FAULT
Digital Input State C1A LP1LP2C2A RHAAFS HUA BRA RET
08 Equipment State Code
02 080102 16:30 COMP#1 FAULT
03 080102 16:30 COMP#2 FAULT
Lock Signal 04 080102 16:45 X HEATER FAULT
CORDEX
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-B6
SENSETE°CH®
DX Series
CWC
DX200 / DX240 / DX270 Screw Compressor Controller
HEAT-EDGE®
DX200 series based on microprocessor has realized the best control and stability with deciding
and controlling capacity adjustment timing for screw compressor and perfect interface with safety
devices.
RAINBOW
- Efcient step/stepless control, convenience for operation and inspection
- One-touch setup function (Choosing the maker -> Automatic setup according to
their basic spec.) (Bitzer, Hitachi, Refcomp, Fusheng, Hanbell, Mitsubishi, Roltec, Kobe)
- Strong timer function (Step delay, Start delay, Auto-stop delay, Restart delay,
Pump down delay)
DOTECH
-Temperature control, Pressure control (input temperature, output temperature,
Intake pressure control, Discharge gas temperature control and observation)
SHIMADEN
- DX270 : 1 Cycle Screw Compressor Controller (Step Control)
- DX200H : 1 Cycle Screw Heat Pump Compressor Controller
- DX220H : 1~2 Cycle Screw Heat Pump Compressor Controller
ㅇDX200 (Stepless)
PR ELECTRONICS
PV C SP C
OPERATION
7.0
25.5
Current Temperature
Set Temperature ▶Set Point : 10.0 ℃
1 Step Start Devia on : +3.0 ℃
D.C GAS : 14 C Discharge Gas Temperature 2 Step Start Devia on : +4.0 ℃
MENU SELECT 1 Step Stop Devia on : - 2.0 ℃
Digital Output State INCDECSTSSOL CM CY CD LIS ALR PM 08:20 Current Time
RUN INFO 2 Step Stop Devia on : - 1.0 ℃
Opera on State LOC STP STAND BY Alarm Message OPERATION
Digital Input State OCC REV LPS HPS 51 Equipment State Code TRIP LOG
TRIP LOG
TRIP & ALARM
23 000101 00:00 Low Temp Alarm
KIMO
Lock Signal 24 000101 00:00 Outlet T-Sense Fault
ㅇDX270 (Step) 25 000101 00:00 DC Gas#1 T sensor
26 000101 00:00 DC Gas#2 T sensor
PV SP 7 000101 00:00 X Low Temp Alarm
C C
7.0
25.5
Current Temperature
Set Temperature
TRIP & ALARM
D.C GAS : 14 C Discharge Gas Temperature
OHKURA
Pump(Fan) Interlock Delay : 0 sec
Digital Output State S1% S2% S3% SOL CM CY CD LIS ALR PM 08:20 Current Time Pump(Fan) Interlock Hold : 2 sec
Discharge Gas Over Temp : 105 ℃
Opera on State LOC STP GOOD START READY Alarm Message Freezing Protec on Temp : 2.0 ℃
Low Temp Alarm : 5.0 ℃
Digital Input State OCC REV LPS HPS OLS OVH FSPILRET 51 Equipment State Code
Lock Signal
SEKONIC
Wiring Diagram (DX200 : Stepless)
UIC DX200 Series 100 200
J1 - 3 G N3 J21 - 3 R3
START SOL
200 G (HOT) SOL V/V J21 - 4
FOR LIQUID N4 R4
J11 - 1 +24V
B4 SPARE
AC 220V FUSE J11 - 2
50/60Hz 250VAC 5A OUTPUT COMMON 1 C1 J21 - 5
External Capcity Control J11 - 3 B5 External Capcity
4~20mAdc / 0~100% J11 - 4 AVSS Control Signal
* OPTION
MMI CONNECTION TB1 - 1 GND
FRIED ELECTRIC
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-B7
SENSETE°CH®
DX Series
CWC
DX200 series based on microprocessor performs best operation (control) automatically according
to set condition and unit ’s operation status which conducting efcient operation of 1~2 cycle
compressor.
RAINBOW
OPERATION
▶ SET VALUE : 7.0 ℃
RUN DIFFERENTIAL : +1.0 ℃
STOP DIFFERENTIAL : -0.5 ℃
PV C SP : 10.0 C MENU SELECT 50% CAP. DIFFERENTIAL : +0.2 ℃
Current
TRIP LOG
GAS#1 : 45 C TRIP & ALARM
TRIP & ALARM
Digital FLOW SENSING DELAY : 60 ℃
Output State
ALR 08:20 Current Time FLOW SENSING HOLD : 5℃
DISCHARGE TEMP OVER : 115℃
Opera on State LOC STP STAND BY Alarm Message OUTLET TEMP FREEZE : 2.0℃
LOW TEMP PROTECT : 5.0℃
Equipment
51 State Code
OHKURA
TRIP LOG
Lock Signal
05 000101 00:00 COND-FAN FAULT
06 000101 00:00 COMP INT FAULT
07 000101 00:00 OUTLET SENS. FLT
08 000101 00:00 DS GAS SENS. FLT
09 000101 00:00 INLET SENS FLT
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-B8
SENSETE°CH®
DX Series
CWC
DX260 Multi Compressor Controller
HEAT-EDGE®
DX260 series has realized the best control and stability with ideal control of the number of
equipment, such as equal & backup operation and perfect interface with safety devices. Its elegant
graphic LCD display and LED helps users to check the current state of the units.
RAINBOW
Also, it provides users with the information about PM & trip alarm history for quick and easy treatment.
DOTECH
(Setting On/Off value per individuals and/or per between steps)
- Perfect equal control (Within 1 hour difference of the total accumulated operation time)
- Pressure/temperature control (Individual and/or interlocking control for intake
pressure, discharge pressure)
- Strong storing and/or monitoring function for trip alarm history/state (Max. 200 cases)
SHIMADEN
- Optimal function for condensing fan speed control (4~20mA PID control)
- Transmission output function (Pressure / Temperature transmission)
- PC monitoring system using RS485 communication based on MODBUS protocol
Applications
PR ELECTRONICS
- Multi Condensing Unit
- Multi Compressor Control
KIMO
RUN/STOP DIFF : +1.00 bar
MENU SELECT FAN SET VALUE : 13.0 bar
FAN STOP DIFF : + 0.7 bar
PV SP bar RUN INFO
2.0
bar Set Low
Current
Low Pressure 2.0 Pressure
OPERATION
SCHEDULE
TRIP LOG
TRIP LOG
bar High Pressure 00 080102 15:55 POWER ON FIRST
HPrs 12.3 01 080102 16:10 COMP#1 FAULT
OHKURA
02 080102 16:30 COMP#2 FAULT
Digital Output State C1 C2 C3 C4 F1 F2 F3 F4 N9 N10 N11 N12 08 :20 Currrent Time 03 080102 16:30 COMP#3 FAULT
04 080102 16:45 X COMP#4 FAULT
Opera on State LOC STP STAND BY Alarm Message
CA1 CA2 CA3 CA4 FA1 FA2 FA3 FA4 ILC RET Equipment
Digital Input State 06 State Code TRIP LOG STATE
Lock Signal COMP#1 FAULT 080102 16:30
SEKONIC
LP : -1.00bar HP : 0.0bar
ID (10~1):
N (12~1):
J12 - 5 B3
CONDENSER #4 N8 J22 - 4 R8
Compressor #1 Alarm ON/OFF CONTROL
J13 - 1 ID1 COMP#1 ALARM
OUTPUT COMMON 2 C2 J22 - 5
Compressor #2 Alarm
J13 - 2 ID2 COMP#2 ALARM
Compressor #3 Alarm TOTAL ALARM
J13 - 3 ID3 COMP#3 ALARM N9 J23 - 1 R9
STATE SIGNAL
Compressor #4 Alarm COMP RUN/STOP
J13 - 4 ID4 COMP#4 ALARM N10 J23 - 2 R10
STATE SIGNAL
Condenser #1 Alarm COMP ALL ALARM
J13 - 5 ID5 FAN#1 ALARM N11 J23 - 3 R11
STATE SIGNAL
G (HOT) SYSTEM RUN/STOP N12
J13 - 6 IDC1 ID COMMON J23 - 4 R12
STATE SIGNAL
Condenser #2 Alarm
J14 - 1 ID6 FAN#2 ALARM
* Optional Spec.
Condenser #3 Alarm MULTI FUNCTION Y1 J6 - 1
J14 - 2 ID7 FAN#3 ALARM ANALOG#1(4~20mA) YG1 J6 - 2
Condenser #4 Alarm MULTI FUNCTION Y2 J6 - 3
J14 - 3 ID8 FAN#4 ALARM ANALOG#2(4~20mA) YG2 J6 - 4
Interlock Alarm MULTI FUNCTION Y3 J6 - 5
J14 - 4 ID9 INTERLOCK ALARM ANALOG#3(4~20mA) YG3
J6 - 6
Remote Signal * MULTI - FUNCTION CONTROL (Selctable User)
J14 - 5 ID10 REMOTE ON/OFF
MULTI FUNCTION (N9~N12)
G (HOT)
J14 - 6 IDC2 ID COMMON * OFF
* RUN STATE
* Optional Spec. * RUN WAIT STATE
MMI CONNECTION TB1 - 1 SG * COMP RUN
FRIED ELECTRIC
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-B9
SENSETE°CH®
DX Series
CWC
DX230H which is an optimal control algorism designed for heat pump system has realized the best
control and stability with ideal control and perfect interface with safety devices. Its elegant graphic
LCD display and LED helps users to check the current state of the units. Also, it provides user with the
RAINBOW
information about PM & trip alarm history for quick and easy treatment.
- Strong storing and/or monitoring function for trip alarm history/state (Max. 160 cases)
- Transmission output (Temperature transmission)
- PC monitoring system using RS485 communication based on MODBUS protocol
Applications
PR ELECTRONICS
7.5
C C
45
RUN INFO
Current Set Temperature
Temperature OPERATION
Geothermy SCHEDULE
Output TRIP LOG
GEO TEMP. : 24.8 C TRIP LOG
Temperature 00 080102 15:55 POWER ON FIRST
OHKURA
Equipment
Digital Input State OCCOPSINT HPSLPS HCS FSPILRET 02 State Code
TRIP LOG STATE
Run/Stop Hea ng, Day/Night Equipment State Lock Signal
SEKONIC
State Cooling opera on State (Failure, Alarm, Maintain) COMP OCR 080102 16:30
OPERATING(Y/D) GEO TEMP. : 24.8℃
State OUT : 15.0℃ HP : 12.1℃
ID (10~1):
N (12~1):
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-B10
SENSETE°CH®
DX Series
CWC
DX540H Air-Source Heat Pump Controller
HEAT-EDGE®
UIC DX540H is a ideal controller for air source heat pump. It is based on microprocessor and
designed with algorithm optimised for air source heat pump. UIC DX540H operates efciently and
manages intensively refrigerant compressor of heat pump. It promotes energy-saving through judge
RAINBOW
and control timing of capacity regulation. UIC DX540H is a system to prevent occurrence of
problem by alarming and inform of necessary maintenance.
DOTECH
- The best calculation function of defrosting timing by various combination of 8 sources
- Embedded day-timer to enable energy-saving operation
- Easy expansion due to various analog transmission output function
- Alarm function to inform of time to maintain and change expendables through
automatic calculation
- Additional state output 4 relays for suction temperature, water temperature,
SHIMADEN
evaporation temperature, etc.
Applications
- Air source heat pump
PR ELECTRONICS
Screen Composition MENU Composition
OPERATION
▶HEAT SET VALUE : 7.0°C
HEAT SET VALUE : -50.0°C
STEP1 OP DEV. : -2.0°C
STEP2 OP DEV. : -3.0°C
MENU SELECT STEP2 STOP DEV : 0.0°C
KIMO
Temperature,
C TSUC 50.0℃ RUN INFO
Current Temperature Operation
OPERATION
24.5
(Inlet/Outlet)
TIN 24.5℃ Time Info
SCHEDULE
TOUT 26.0℃ TRIP LOG
TRIP LOG
TAMB 7.7℃ 00 080102 15:55 INLET FAULT
01 080102 16:10 OUTLET FAULT
02 080102 16:30 OUT AIR FAULT
Digital Output State C1 C2 SOL DEF 4W PM 0820
: Current Time
03 080102 16:30 DISCHARGE FAULT
OHKURA
04 080102 16:45 X EVAPO. FAULT
Operation State LOC STP Discharge Fault Alarm Message
Digital Input State OC1 LPS HPSOC2 ID5 FSL HCS RET 02 Equipment State Code
TRIP LOG STATE
Heating/Cooling State Lock Signal EVAPO.FAULT 0909102 16:30
STATE : STAND BY
Tsuc. - 40.0 bar Tsp 0.0°C
ID (10~1) :
N (12~1) :
SEKONIC
Wiring Diagram (DX540H)
HUBA
KAISE
CORDEX
FRIED ELECTRIC
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-B11
SENSETE°CH®
HTX Series
CWC
and HumiditySensor
HUMITRON® HTX20 series,OEM type product line, are modules for sensing temperature and humidity with reasonable price, high precision and high quality. They are ideal for various
application because of excellent stability. Their design reminds shuttle spacecraft. They are intended to minimize spatial constraints through compact-slip design when installed on HVAC or
control equipment. HUMITRON® HTX20 series are plug connection type. They can detect relative humidity, temperature and dew point by measuring.
RAINBOW
Features
Integration of temperature and humidity measurement function
Easy to be applied to the system
Compatibility plug-In design
DOTECH
Applications
Thermo-hygrostat, Humidier / Dehumidiers
SHIMADEN
HUMITRON® HTX23 series is a module for detection of temperature and humidity which is especially for OEM and satisfactory in aspects of price and quality. It provides users with 4~20mA
standard interface and it is designed with compact and slim shape, so users don’t need to consider any spatial restriction or exposure when it is installed inside or outside of various types of
climate control units or control facilities. Also, it can help users to reduce unnecessary cost and to minimize works efciency through to reduce unnecessary cost and to maximize works efciency
SEKONIC
through combination of 4~20mA standard humidity output and various temperature outputs (including passive) according to users’ needs.
Features
Unied function for measuring temperature & humidity.
Easy installation
Compact & slim size – 63(L) x 63(W) x 16(H) (mm)
HUBA
Applications
Constant temperature & humidity control
Temperature & humidity data collection
KAISE
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-C12
SENSETE°CH®
HTX Series
CWC
Ultra-precise Indoor Type Temperature
HTX500 Series
HEAT-EDGE®
and Humidity Transmitter
HUMITRON® HTD500 series is an ultra-precise temperature & humidity transmitter for environmental measuring which integrates micro processor with a digital sensor based on MEMS
technology. It makes precise control and efcient observation possible by transmitting measured temperature and humidity information to analogue output , control and obser vation system
through RS485 communication function in real-time. Also, it supplies users excellent attention even at wide place by applying for a bog sized FND.
RAINBOW
Features
Digital sensor applied for MEMS technology
Embedded RS485 communication port based on MODBUS RTU/ASCII
Excellent long-term stability and self-digital correction
DOTECH
Quick counteraction speed (within 4 sec.)
Slim size – 310(L) x 280(H) x 45(D) (mm)
Applications
Clean room / Measuring center / Inspection room
SHIMADEN
Food company / Pharmaceutical company R&D center, Process control
Wall-Unit Computer room / Storage monitoring system
Storage for foods, medicines, cereals, woods and electronic devices
Technical data & Model
PR ELECTRONICS
Range : 5~95%RH / -10~60°C
Accuracy – HTD520 : ±1.8%RH / ±0.3°C – HTD520 : ±3.0%RH / ±0.5°C
Output : 4~20mA, RS485 communication (MODBUS RTU/ASCII)
Power input : 24VDC (Free adaptor supplied)
KIMO
HTD520 – 00 : Display only
HTX520 – 11 : Humidity (4~20mA), Temperature (4~20mA), RS485 communication
OHKURA
Humidity Module (1.0~3.6V output)
HTX3515 is a dedicated humidity and play transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made
possible with the module’s humidity linear voltage. HTX3515 is designed for high volume and demanding applications.
SEKONIC
Applications
Reliability not affected by repeated condensations
Demonstrated reliability and long term stability
Typical 1 to 3.6 Volt DC output for 0 to 100% RH at 5VDC supply
HUBA
Cable
1 : Black - humidity sensor power 0V
2 : Red - himidity power+5V
4 : White - Signal output for humidity measurement
CORDEX
FRIED ELECTRIC
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com [email protected] Tel No. 532-0088 Fax No. 531-7387
V-C13