Generic IEC61850 IED ConnPack ReleaseNotes - v2 - 4 - 3
Generic IEC61850 IED ConnPack ReleaseNotes - v2 - 4 - 3
Release
2011-08-19
Release Notes
New Features
Error Corrections
Improvements
To ensure downwards compatibility to PCM600 versions 2.1. or 2.2 the former
version 2.1.1 of the Generic IEC61850 IED Connectivity Package is installed in
parallel and will be automatically activated if such a PCM600 version is used.
1
ABB Switzerland Ltd. Release Notes Generic IEC6180 IED
Connectivity Package
v.2.4.3
Error Corrections
Error Corrections
While fixing this problem another problem in the PCM600 Disturbance Handling
Tool (DHT) was revealed, because in DR files from GE IEDs the value for
‘number of sample rates’ (refered as nsamp in the COMTRADE standard) is zero.
This confuses the DHT tool such that after successful upload of the DR files
duplicate rows are shown, one for the DR in the IED showing the correct trigger
time and another row for the uploaded DR file on the PC showing by mistake the
start time of the DR instead of the trigger time. The same problem has also been
observed on some types of SIEMENS IEDs. A problem report has been issued to
2
ABB Switzerland Ltd. Release Notes Generic IEC6180 IED
Connectivity Package
v.2.4.3
Improvements
Error Corrections
3
ABB Switzerland Ltd. Release Notes Generic IEC6180 IED
Connectivity Package
v.2.4.3
Opening DHT for Generic IED at wrong time => PCM gets stuck
(E_ABB_PR_20250)
Scheduler remains reading for generic IED (E_ABB_PR_20266)
There was a deadlock situation when the Connectivity Package was used in
Scheduler mode, and also sometimes when used in interactive mode. This problem
has been corrected.
Documentation Updates
The document “Generic IEC61850 IED Connectivity Package User’s Guide” (file
“Generic IEC61850 IED ConnPack Users Guide.pdf”, ID 1KHA001027-UEN)
has been largely revised to reflect the changes done in the new version 2.4.x of the
Generic IEC61850 IED Connectivity Package and the modified user interface of
PCM600 version 2.4.
Installation
Double click on the file “ABB Generic IEC61850 IED Connectivity Package
Ver. 2.4.3.msi”and follow the instructions on the screen. See also chapter 2:
“Installation and uninstallation” of document “Generic IEC61850 IED
Connectivity Package User’s Guide” (file “Generic IEC61850 IED ConnPack
Users Guide.pdf”, document ID 1KHA001027-UEN)
4
ABB Switzerland Ltd. Release Notes Generic IEC6180 IED
Connectivity Package
v.2.4.3
Generic IEC6180 IED Connectivity Package version 2.4.x is a bug fix release
replacing former versions 2.1 and 2.1.1, but remains fully compatible to it.
Testing Notice
The Generic IEC6180 IED Connectivity Package has been tested with the
following devices:
• ABB REx670 Firmware version 1.1 or higher
• ABB REx650 Firmware version 1.0 or higher
• ABB REx630 Firmware version 1.0 or higher
• ABB REx615 Firmware version 3.0 or higher
• ABB REB500 Firmware version 7.40 or higher
• ABB REF542plus
(via SPA-ZC40x) Firmware version 3.0 or higher
• ABB REx541/543/545
(via SPA-ZC40x)
• SIEMENS 7SA612
• SIEMENS 6MD66
• SIEMENS 7UT61
• SIEMENS 7SJ80
• Areva P632
• Areva P439
• GE D60
5
ABB Switzerland Ltd. Release Notes Generic IEC6180 IED
Connectivity Package
v.2.4.3
Known Limitations
• DR upload is not possible for SEL (Schweitzer Electronic Laboratories) IEDs
because these IEDs only support DR upload using ftp but not by IEC61850
MMS.
• Some IED types (e.g. SIEMENS, Areva) do not support DR deletion in the
IED at all.
• On ABB REB500 IEDs only the oldest disturbance record can be deleted.
• On ABB REx670 IEDs of firmware versions 1.0 and 1.1 deletion of specific
disturbance records is not working. Only all DRs can be deleted.
• Deleting many disturbance records on ABB REx670, REx650 and REx630
IEDs may take rather a long time (a few minutes) until the list of recordings in
the IED is appropriately refreshed.
• The Scheduler operation only works if no PCM600 project is open at the same
time, otherwise you will get communication failure messages.