0% found this document useful (0 votes)
53 views23 pages

DSP - Detials

The document contains output from several commands run on a CGP device. It lists information about the device including its name and type, other devices on the subnet, hard disk details showing serial numbers and storage capacity, and labels for components in the first subrack.

Uploaded by

Manoj Pasupuleti
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views23 pages

DSP - Detials

The document contains output from several commands run on a CGP device. It lists information about the device including its name and type, other devices on the subnet, hard disk details showing serial numbers and storage capacity, and labels for components in the first subrack.

Uploaded by

Manoj Pasupuleti
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 23

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 08:57:48+01:00 DST

O&M #89
%%SET RMTSWITCH: RMTTP=SOL, RMTSTS=ON,CONFIRM=Y;%%
RETCODE = 0 Operation succeeded

--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:13:44+01:00 DST


O&M #371
%%LST ME:;%%
RETCODE = 0 Operation succeeded

The result is as follows


------------------------
Domain ID Subnet ID ME ID ME name ME type ME version ME
vendor ME user-defined state Location name ME lock status ME Country Code ME
Interface ID ME Language ME patch version ME mode
Architecture type

1 0 0 brnt-asbccgf-3 CGP V200R020C00SPC200 HUAWEI


Normal NULL Unlocked NULL
CGPV200R020C00SPC200_M20 ENG V200R020C00SPC200 Enhanced site
management X86
1 0 450 brnt-asbc-3 SE2900 V300R018C10SPC301 Huawei
Normal Brentford Unlocked NULL
SE2900V300R018C10SPC301 ENG SE2900_V300R018C10SPH303 NULL
X86
(Number of results = 2)

--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:14:03+01:00 DST


O&M #376
%%DSP HARDDISK:;%%
RETCODE = 0 Operation succeeded

Hard disk information


---------------------
Subrack number Slot number Rack number Position number Location Hard disk ID
Serial number Vendor name Hard disk state Total capacity of
physical hard disk(MB) Available space of logical hard disk(MB) Link status of
the hard disk Drive letter Firmware version Number of elements on the Glist
Powered-on duration(hour) Powered-on times Temperature(Celsius) Number of
uncorrectable errors

0 1 0 2 Front 0
RS200000010000025759 TDK GBDriver RS2 Normal 7679
5256 Normal /dev/sda
0x8104 NULL NULL NULL
NULL NULL
0 2 0 2 Front GPC 0
W7H654DG HITACHI HUC109060CSS600 Normal 545811
186164 Normal /dev/sda
A440 0 56408 17
32 0
0 3 0 2 Front 0
RS200000020000025943 TDK GBDriver RS2 Normal 7679
5521 Normal /dev/sda
0x8104 NULL NULL NULL
NULL NULL
0 4 0 2 Front 0
RS200000020000066323 TDK GBDriver RS2 Normal 7679
5589 Normal /dev/sda
0x8104 NULL NULL NULL
NULL NULL
0 5 0 2 Front GPC 0
W7H657XG HITACHI HUC109060CSS600 Normal 545811
188786 Normal /dev/sda
A440 0 56422 17
32 0
0 6 0 2 Front 0
RS200000010000025775 TDK GBDriver RS2 Normal 7679
5487 Normal /dev/sda
0x8104 NULL NULL NULL
NULL NULL
(Number of results = 6)

Hard disk controller information


--------------------------------
Subrack number Slot number Rack number Position number Location Status of
the hard disk controller Port status of the hard disk controller

0 1 0 2 Front Normal
Normal
0 2 0 2 Front GPC Normal
Normal
0 3 0 2 Front Normal
Normal
0 4 0 2 Front Normal
Normal
0 5 0 2 Front GPC Normal
Normal
0 6 0 2 Front Normal
Normal
(Number of results = 6)

--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:14:24+01:00 DST


O&M #380
%%DSP BRDRAID:;%%
RETCODE = 0 Operation succeeded

The result is as follows


------------------------
Subrack number Slot number Rack number Position number Location RAID ID
RAID state RAID type Number of hard disks Rebuilding ratio(%) Capacity(MB)

0 1 0 2 Front NULL
NULL NULL NULL NULL NULL
0 2 0 2 Front GPC NULL
NULL NULL NULL NULL NULL
0 3 0 2 Front NULL
NULL NULL NULL NULL NULL
0 4 0 2 Front NULL
NULL NULL NULL NULL NULL
0 5 0 2 Front GPC NULL
NULL NULL NULL NULL NULL
0 6 0 2 Front NULL
NULL NULL NULL NULL NULL
(Number of results = 6)

--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:14:49+01:00 DST


O&M #386
%%DSP ELABEL: OT=SUBRACK, SRN=0;%%
RETCODE = 0 Operation succeeded

Progress Report
---------------
Report Type = DSP ELABEL
Status = Start
Progress = 0%
Session ID = 983040
(Number of results = 1)

--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:14:52+01:00 DST


O&M #386
%%DSP ELABEL: OT=SUBRACK, SRN=0;%%
RETCODE = 0 Operation succeeded

Progress Report
---------------
Report Type = DSP ELABEL
Status = Success
Progress = 100%
Session ID = 983040
(Number of results = 1)

--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:14:52+01:00 DST


O&M #386
%%DSP ELABEL: OT=SUBRACK, SRN=0;%%
RETCODE = 0 Operation succeeded

The subrack result is as follows


--------------------------------
Subrack number = 0
Rack number = 0
Position number = 2
Object type = Subrack
Operation result = Success
BoardType = F8002
BarCode = 2102300809N0F6000073
Item = NULL
Description = NULL
Manufactured = 2004-07-03
VendorName = Huawei Technologies Co., Ltd.
IssueNumber = NULL
CLEICode = NULL
BOM = NULL
Model = NULL
(Number of results = 1)
The board result is as follows
------------------------------
Subrack number Slot number Rack number Position number Object type Location
Operation result BoardType BarCode Item Description
Manufactured VendorName IssueNumber CLEICode BOM Model

0 1 0 2 Board Front
Success CH80SPUA1 210305526310F7000053 03055263 Finished Board
Unit,FusionEngine,CH80SPUA1,Service Processing Unit A1,2*CPU 2015-07-08 Huawei
00 Null Null NULL
0 1 0 2 Port Port7
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 1 0 2 Port Port6
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 1 0 2 Port Port5
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 1 0 2 Port Port4
Success MXPD-243S HA15220561713 NULL LC
150608 HG GENUINE NULL NULL NULL NULL
0 1 0 2 Port Port3
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 1 0 2 Port Port2
Success FTLX1471D3BCL-HU ATK02NQ NULL LC
150510 FINISAR CORP. NULL NULL NULL NULL
0 1 0 2 Port Port1
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 1 0 2 Port Port0
Success MTRS-02X13-G MB15230010229 NULL LC
150610 HG GENUINE NULL NULL NULL NULL
0 2 0 2 Board Front
Success CH80MXUA0 210305526110F7000062 03055261 Finished Board
Unit,FusionEngine,CH80MXUA0,Multi-function Switch Unit A0 2015-07-08 Huawei
00 Null Null NULL
0 2 0 2 Port
Fabric/Lan1 Uninstalled NULL NULL NULL
NULL NULL
NULL NULL NULL NULL NULL
0 2 0 2 Port
Fabric/Lan0 Success AFBR-79EIDZ QF18047P NULL
41200Mb/s-850nm-MPO-100m(0.05mm) 2015-
04-30 AVAGO NULL NULL NULL NULL
0 3 0 2 Board Front
Success CH80SPUA1 210305526310F8000015 03055263 Finished Board
Unit,FusionEngine,CH80SPUA1,Service Processing Unit A1,2*CPU 2015-08-05 Huawei
00 Null Null NULL
0 3 0 2 Port Port7
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 3 0 2 Port Port6
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 3 0 2 Port Port5
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 3 0 2 Port Port4
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 3 0 2 Port Port3
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 3 0 2 Port Port2
Success TRS5021EN-SP11 T15B68303 NULL LC
15021700 OCLARO,INC NULL NULL NULL NULL
0 3 0 2 Port Port1
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 3 0 2 Port Port0
Success MTRS-02X13-G MB15100081822 NULL LC
150312 HG GENUINE NULL NULL NULL NULL
0 4 0 2 Board Front
Success CH80SPUA1 210305526310K7000023 03055263 Finished Board
Unit,OSTA5.0,CH80SPUA1,Service Processing Unit A1,2*CPU 2019-07-02 Huawei
00 Null Null NULL
0 4 0 2 Port Port7
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 4 0 2 Port Port6
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 4 0 2 Port Port5
Success MXPD-243S HA15220680591 NULL LC
150605 HG GENUINE NULL NULL NULL NULL
0 4 0 2 Port Port4
Success MXPD-243S HA15220330949 NULL LC
150603 HG GENUINE NULL NULL NULL NULL
0 4 0 2 Port Port3
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 4 0 2 Port Port2
Success FTLX1471D3BCL-HU ATK04NC NULL LC
150510 FINISAR CORP. NULL NULL NULL NULL
0 4 0 2 Port Port1
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 4 0 2 Port Port0
Success MTRS-02X13-G MB15230010016 NULL LC
150610 HG GENUINE NULL NULL NULL NULL
0 5 0 2 Board Front
Success CH80MXUA0 210305526110F7000063 03055261 Finished Board
Unit,FusionEngine,CH80MXUA0,Multi-function Switch Unit A0 2015-07-09 Huawei
00 Null Null NULL
0 5 0 2 Port
Fabric/Lan1 Uninstalled NULL NULL NULL
NULL NULL
NULL NULL NULL NULL NULL
0 5 0 2 Port
Fabric/Lan0 Success AFBR-79EIDZ QF18047Q NULL
41200Mb/s-850nm-MPO-100m(0.05mm) 2015-
04-30 AVAGO NULL NULL NULL NULL
0 6 0 2 Board Front
Success CH80SPUA1 210305526310F8000016 03055263 Finished Board
Unit,FusionEngine,CH80SPUA1,Service Processing Unit A1,2*CPU 2015-08-05 Huawei
00 Null Null NULL
0 6 0 2 Port Port7
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 6 0 2 Port Port6
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 6 0 2 Port Port5
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 6 0 2 Port Port4
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 6 0 2 Port Port3
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 6 0 2 Port Port2
Success MTRS-02X13-G MB15250150375 NULL LC
150625 HG GENUINE NULL NULL NULL NULL
0 6 0 2 Port Port1
Uninstalled NULL NULL NULL NULL
NULL NULL NULL NULL NULL NULL
0 6 0 2 Port Port0
Success MTRS-02X13-G MB15250150878 NULL LC
150625 HG GENUINE NULL NULL NULL NULL
(Number of results = 42)

The power entry module result is as follows


-------------------------------------------
Subrack number Rack number Position number PEM name Object type
Operation result BoardType BarCode Item Description
Manufactured VendorName IssueNumber CLEICode BOM Model

0 0 2 PEM1 Power entry module


Success CH80PEMA 022ADW10F6000080 03022ADW MCCA,CH80PEMA,Power Entry
Monitor Board ,1*2 2015-06-24 Huawei 00 NULL NULL NULL
0 0 2 PEM2 Power entry module
Success CH80PEMA 022ADW10F6000084 03022ADW MCCA,CH80PEMA,Power Entry
Monitor Board ,1*2 2015-06-24 Huawei 00 NULL NULL NULL
(Number of results = 2)

The fan board result is as follows


----------------------------------
Subrack number Rack number Position number Fan name Object type Operation
result BoardType BarCode Item Description
Manufactured VendorName IssueNumber CLEICode BOM Model

0 0 2 FAN1 Fan Success


CH8E01FAN 2102120956N0F6000383 02120956 Fan Tray
Assembly,FusionEngine,CH8E01FAN,FusionEngine FAN BOX 2015-07-02 Huawei 00
Null Null NULL
0 0 2 FAN2 Fan Success
CH8E01FAN 2102120956P0K4000036 02120956 Fan Tray Assembly,F8000,CH8E01FAN,F8000
FAN BOX 2019-04-17 Huawei 00 Null Null
NULL
(Number of results = 2)

3 reports in total
--- END
+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:15:02+01:00 DST
O&M #394
%%DSP FW:;%%
RETCODE = 0 Operation succeeded

The rate of querying firmware version is as follows


---------------------------------------------------
Completed percentage = 0%
(Number of results = 1)

--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:15:04+01:00 DST


O&M #394
%%DSP FW:;%%
RETCODE = 0 Operation succeeded

The rate of querying firmware version is as follows


---------------------------------------------------
Completed percentage = 100%
(Number of results = 1)

--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:15:04+01:00 DST


O&M #394
%%DSP FW:;%%
RETCODE = 0 Operation succeeded

The result of querying board firmware version is as follows


-----------------------------------------------------------
Subrack number Slot number Location Firmware name Firmware sequence
number Run version Configured version Board type Result of version check

0 1 Front QFSA_BIOS_ARM 0
390 100 SPUA1 Consistent
0 1 Front QFSA_BIOS_X86 0
252 252 SPUA1 Consistent
0 1 Front QFSA_BMC_ARM 0
8012 100 SPUA1 Consistent
0 1 Front QFSA_BOOT_CPLD 0
308 308 SPUA1 Consistent
0 1 Front QFSA_BOOT_FPGA 0
112 201 SPUA1 Matched
0 1 Front QFSA_DISK_SSD_TDK 0
0x8104 0x8104 SPUA1 Consistent
0 1 Front QFSA_ME_X86 0
6.3.50.1252 6.5.50.1252 SPUA1 Matched
0 1 Front QFSA_SDR 0
416 100 SPUA1 Consistent
0 2 Front GPC MFXA_BIOS_X86 0
225 250 MXUA0 Matched
0 2 Front GPC MFXA_ME_X86 0
8.103.30.1350 8.103.30.1350 MXUA0 Consistent
0 2 Front XMC MFXA_APP_SMM 0
8232 8232 MXUA0 Consistent
0 2 Front XMC MFXA_BIOS_PPC 0
226 8300 MXUA0 Matched
0 2 Front XMC MFXA_BOOT_CPLD 0
314 506 MXUA0 Matched
0 2 Front XMC MFXA_BOOT_FPGA 0
113 201 MXUA0 Matched
0 2 Front XMC MFXA_BOOT_MCU 0
644 644 MXUA0 Consistent
0 2 Front XMC MFXA_LSW_BASE 0
8231 8231 MXUA0 Consistent
0 2 Front XMC MFXA_LSW_FABRIC 0
8231 8231 MXUA0 Consistent
0 2 Front XMC MFXA_OS_PPC 0
8232 8232 MXUA0 Consistent
0 2 Front XMC MFXA_SDR 0
455 455 MXUA0 Consistent
0 3 Front QFSA_BIOS_ARM 0
390 100 SPUA1 Consistent
0 3 Front QFSA_BIOS_X86 0
252 252 SPUA1 Consistent
0 3 Front QFSA_BMC_ARM 0
8012 100 SPUA1 Consistent
0 3 Front QFSA_BOOT_CPLD 0
308 308 SPUA1 Consistent
0 3 Front QFSA_BOOT_FPGA 0
112 201 SPUA1 Matched
0 3 Front QFSA_DISK_SSD_TDK 0
0x8104 0x8104 SPUA1 Consistent
0 3 Front QFSA_ME_X86 0
6.3.50.1252 6.5.50.1252 SPUA1 Matched
0 3 Front QFSA_SDR 0
416 100 SPUA1 Consistent
0 4 Front QFSA_BIOS_ARM 0
390 100 SPUA1 Consistent
0 4 Front QFSA_BIOS_X86 0
238 252 SPUA1 Matched
0 4 Front QFSA_BMC_ARM 0
8015 100 SPUA1 Consistent
0 4 Front QFSA_BOOT_CPLD 0
308 308 SPUA1 Consistent
0 4 Front QFSA_BOOT_FPGA 0
112 201 SPUA1 Matched
0 4 Front QFSA_DISK_SSD_TDK 0
0x8104 0x8104 SPUA1 Consistent
0 4 Front QFSA_ME_X86 0
6.5.50.1252 6.5.50.1252 SPUA1 Consistent
0 4 Front QFSA_SDR 0
416 100 SPUA1 Consistent
0 5 Front GPC MFXA_BIOS_X86 0
225 250 MXUA0 Matched
0 5 Front GPC MFXA_ME_X86 0
8.103.30.1350 8.103.30.1350 MXUA0 Consistent
0 5 Front XMC MFXA_APP_SMM 0
8232 8232 MXUA0 Consistent
0 5 Front XMC MFXA_BIOS_PPC 0
226 8300 MXUA0 Matched
0 5 Front XMC MFXA_BOOT_CPLD 0
314 506 MXUA0 Matched
0 5 Front XMC MFXA_BOOT_FPGA 0
113 201 MXUA0 Matched
0 5 Front XMC MFXA_BOOT_MCU 0
644 644 MXUA0 Consistent
0 5 Front XMC MFXA_LSW_BASE 0
8231 8231 MXUA0 Consistent
0 5 Front XMC MFXA_LSW_FABRIC 0
8231 8231 MXUA0 Consistent
0 5 Front XMC MFXA_OS_PPC 0
8232 8232 MXUA0 Consistent
0 5 Front XMC MFXA_SDR 0
455 455 MXUA0 Consistent
0 6 Front QFSA_BIOS_ARM 0
390 100 SPUA1 Consistent
0 6 Front QFSA_BIOS_X86 0
252 252 SPUA1 Consistent
0 6 Front QFSA_BMC_ARM 0
8012 100 SPUA1 Consistent
0 6 Front QFSA_BOOT_CPLD 0
308 308 SPUA1 Consistent
0 6 Front QFSA_BOOT_FPGA 0
112 201 SPUA1 Matched
0 6 Front QFSA_DISK_SSD_TDK 0
0x8104 0x8104 SPUA1 Consistent
0 6 Front QFSA_ME_X86 0
6.3.50.1252 6.5.50.1252 SPUA1 Matched
0 6 Front QFSA_SDR 0
416 100 SPUA1 Consistent
(Number of results = 54)

To be continued...
--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:15:04+01:00 DST


O&M #394
%%DSP FW:;%%
RETCODE = 0 Operation succeeded

The result of querying fan firmware version as follows


------------------------------------------------------
Subrack number Fan name Firmware name Firmware sequence number Run version
Configured version Result of version check

0 FAN1 FANA_LOAD 0 104


104 Consistent
0 FAN2 FANA_LOAD 0 104
104 Consistent
(Number of results = 2)

To be continued...
--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:15:04+01:00 DST


O&M #394
%%DSP FW:;%%
RETCODE = 0 Operation succeeded

The result of querying power entry module firmware version is as follows


------------------------------------------------------------------------
Subrack number Power entry module name Firmware name Firmware sequence number
Run version Configured version Result of version check
0 PEM1 PEMA_SDR 0
105 310 Matched
0 PEM2 PEMA_SDR 0
105 310 Matched
(Number of results = 2)

5 reports in total
--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:15:25+01:00 DST


O&M #398
%%DSP SENSOR:;%%
RETCODE = 0 Operation succeeded

The result is as follows


------------------------
Subrack number Slot number Rack number Position number Location Sensor name
Sensor value

0 1 0 2 Front +1.0VSB_PCH
0.992 Volts
0 1 0 2 Front +1.8VSB
1.792 Volts
0 1 0 2 Front +3.0V_BAT
3.048 Volts
0 1 0 2 Front +3.3VCC
3.232 Volts
0 1 0 2 Front +3.3VSB
3.264 Volts
0 1 0 2 Front +5.0VCC
4.944 Volts
0 1 0 2 Front -48V Power1
No state assertion event.
0 1 0 2 Front -48V Power2
No state assertion event.
0 1 0 2 Front ACPI Status
[S0 / G0 "working"]
0 1 0 2 Front Board Status
No state assertion event.
0 1 0 2 Front Board
Unstable No state assertion event.
0 1 0 2 Front Boot Error
No state assertion event.
0 1 0 2 Front Brd Inlet
Temp 26.000 degrees C
0 1 0 2 Front Brd Outlet
Temp 39.000 degrees C
0 1 0 2 Front CPU1 Core Rem
-46.000 degrees C
0 1 0 2 Front CPU1 Status
No state assertion event.
0 1 0 2 Front CPU2 Core Rem
-43.000 degrees C
0 1 0 2 Front CPU2 Status
No state assertion event.
0 1 0 2 Front Clock Signal
No state assertion event.
0 1 0 2 Front FRU0 Hot Swap
[M4 - FRU Active]
0 1 0 2 Front FRU1 Hot Swap
[M4 - FRU Active]
0 1 0 2 Front FRU2 Hot Swap
[M4 - FRU Active]
0 1 0 2 Front FW Status
No state assertion event.
0 1 0 2 Front IPMB Link
State [IPMB-A enabled,IPMB-B enabled]
0 1 0 2 Front Memory Status
No state assertion event.
0 1 0 2 Front Mgmt Sys
Health No state assertion event.
0 1 0 2 Front Offline
Button No state assertion event.
0 1 0 2 Front Post Error
No state assertion event.
0 1 0 2 Front Power
231.000 Watts
0 1 0 2 Front Power Good
No state assertion event.
0 1 0 2 Front Slot Num
No state assertion event.
0 1 0 2 Front VTT_DDR_AB
0.656 Volts
0 1 0 2 Front VTT_DDR_EF
0.656 Volts
0 1 0 2 Front Ver. Change
No state assertion event.
0 1 0 2 Front Watchdog
No state assertion event.
0 1 0 2 Front X86 Restart
No state assertion event.
0 2 0 2 Front +0.9VCC
0.911 Volts
0 2 0 2 Front +1.05VCC
1.068 Volts
0 2 0 2 Front +1.0VCC_A
1.009 Volts
0 2 0 2 Front +1.0VCC_C
1.009 Volts
0 2 0 2 Front +1.0VCC_E
1.009 Volts
0 2 0 2 Front +1.2VCC_A
1.215 Volts
0 2 0 2 Front +1.2VCC_B
1.196 Volts
0 2 0 2 Front +1.2VSB
1.205 Volts
0 2 0 2 Front +1.5VCC_A
1.519 Volts
0 2 0 2 Front +1.8VCC_A
1.823 Volts
0 2 0 2 Front +1.8VCC_D
1.793 Volts
0 2 0 2 Front +12V_HDD
11.907 Volts
0 2 0 2 Front +2.5VCC_A
2.519 Volts
0 2 0 2 Front +3.0V_BAT
3.136 Volts
0 2 0 2 Front +3.3VCC_D
3.352 Volts
0 2 0 2 Front +5.0VSB
5.040 Volts
0 2 0 2 Front -48V Power1
No state assertion event.
0 2 0 2 Front -48V Power2
No state assertion event.
0 2 0 2 Front ACPI Status
[S0 / G0 "working"]
0 2 0 2 Front Base OS Boot
No state assertion event.
0 2 0 2 Front Board Status
No state assertion event.
0 2 0 2 Front Board Temp
40.000 degrees C
0 2 0 2 Front Board
Unstable No state assertion event.
0 2 0 2 Front Brd Inlet
Temp 28.000 degrees C
0 2 0 2 Front CPU1 Core Rem
-61.000 degrees C
0 2 0 2 Front Chassis
Status No state assertion event.
0 2 0 2 Front Clock Signal
A No state assertion event.
0 2 0 2 Front Clock Signal
B No state assertion event.
0 2 0 2 Front FRU0 Hot Swap
[M4 - FRU Active]
0 2 0 2 Front FRU1 Hot Swap
[M4 - FRU Active]
0 2 0 2 Front FRU2 Hot Swap
[M4 - FRU Active]
0 2 0 2 Front FW Status
No state assertion event.
0 2 0 2 Front Failover ASIC
No state assertion event.
0 2 0 2 Front IPMB Link
State [IPMB-A enabled,IPMB-B enabled]
0 2 0 2 Front LSW Temp
49.000 degrees C
0 2 0 2 Front Memory Status
No state assertion event.
0 2 0 2 Front Mgmt Sys
Health No state assertion event.
0 2 0 2 Front NIC Status
No state assertion event.
0 2 0 2 Front OAM Status
No state assertion event.
0 2 0 2 Front OS Stop
No state assertion event.
0 2 0 2 Front Offline
Button No state assertion event.
0 2 0 2 Front PPC Memory
No state assertion event.
0 2 0 2 Front PPC Post
Error No state assertion event.
0 2 0 2 Front PPC Restart
No state assertion event.
0 2 0 2 Front PPC Status
No state assertion event.
0 2 0 2 Front PPC Watchdog
No state assertion event.
0 2 0 2 Front Power
118.000 Watts
0 2 0 2 Front Power Good A
No state assertion event.
0 2 0 2 Front Power Good B
No state assertion event.
0 2 0 2 Front SAS
Controller No state assertion event.
0 2 0 2 Front SAS Temp
53.000 degrees C
0 2 0 2 Front Slot Num
No state assertion event.
0 2 0 2 Front Update Chan
No state assertion event.
0 2 0 2 Front Ver. Change
No state assertion event.
0 2 0 2 Front X86 Boot
Error No state assertion event.
0 2 0 2 Front X86 CPU1
Status No state assertion event.
0 2 0 2 Front X86 Post
Error No state assertion event.
0 2 0 2 Front X86 Restart
No state assertion event.
0 2 0 2 Front X86 Watchdog
No state assertion event.
0 3 0 2 Front +1.0VSB_PCH
0.992 Volts
0 3 0 2 Front +1.8VSB
1.792 Volts
0 3 0 2 Front +3.0V_BAT
3.072 Volts
0 3 0 2 Front +3.3VCC
3.232 Volts
0 3 0 2 Front +3.3VSB
3.264 Volts
0 3 0 2 Front +5.0VCC
4.992 Volts
0 3 0 2 Front -48V Power1
No state assertion event.
0 3 0 2 Front -48V Power2
No state assertion event.
0 3 0 2 Front ACPI Status
[S0 / G0 "working"]
0 3 0 2 Front Board Status
No state assertion event.
0 3 0 2 Front Board
Unstable No state assertion event.
0 3 0 2 Front Boot Error
No state assertion event.
0 3 0 2 Front Brd Inlet
Temp 27.000 degrees C
0 3 0 2 Front Brd Outlet
Temp 41.000 degrees C
0 3 0 2 Front CPU1 Core Rem
-47.000 degrees C
0 3 0 2 Front CPU1 Status
No state assertion event.
0 3 0 2 Front CPU2 Core Rem
-44.000 degrees C
0 3 0 2 Front CPU2 Status
No state assertion event.
0 3 0 2 Front Clock Signal
No state assertion event.
0 3 0 2 Front FRU0 Hot Swap
[M4 - FRU Active]
0 3 0 2 Front FRU1 Hot Swap
[M4 - FRU Active]
0 3 0 2 Front FRU2 Hot Swap
[M4 - FRU Active]
0 3 0 2 Front FW Status
No state assertion event.
0 3 0 2 Front IPMB Link
State [IPMB-A enabled,IPMB-B enabled]
0 3 0 2 Front Memory Status
No state assertion event.
0 3 0 2 Front Mgmt Sys
Health No state assertion event.
0 3 0 2 Front Offline
Button No state assertion event.
0 3 0 2 Front Post Error
No state assertion event.
0 3 0 2 Front Power
219.000 Watts
0 3 0 2 Front Power Good
No state assertion event.
0 3 0 2 Front Slot Num
No state assertion event.
0 3 0 2 Front VTT_DDR_AB
0.672 Volts
0 3 0 2 Front VTT_DDR_EF
0.672 Volts
0 3 0 2 Front Ver. Change
No state assertion event.
0 3 0 2 Front Watchdog
No state assertion event.
0 3 0 2 Front X86 Restart
No state assertion event.
0 4 0 2 Front +1.0VSB_PCH
1.008 Volts
0 4 0 2 Front +1.8VSB
1.808 Volts
0 4 0 2 Front +3.0V_BAT
3.000 Volts
0 4 0 2 Front +3.3VCC
3.232 Volts
0 4 0 2 Front +3.3VSB
3.264 Volts
0 4 0 2 Front +5.0VCC
4.992 Volts
0 4 0 2 Front -48V Power1
No state assertion event.
0 4 0 2 Front -48V Power2
No state assertion event.
0 4 0 2 Front ACPI Status
[S0 / G0 "working"]
0 4 0 2 Front Board Status
No state assertion event.
0 4 0 2 Front Board
Unstable No state assertion event.
0 4 0 2 Front Boot Error
No state assertion event.
0 4 0 2 Front Brd Inlet
Temp 27.000 degrees C
0 4 0 2 Front Brd Outlet
Temp 38.000 degrees C
0 4 0 2 Front CPU1 Core Rem
-47.000 degrees C
0 4 0 2 Front CPU1 Status
No state assertion event.
0 4 0 2 Front CPU2 Core Rem
-47.000 degrees C
0 4 0 2 Front CPU2 Status
No state assertion event.
0 4 0 2 Front Clock Signal
No state assertion event.
(Number of results = 150)

To be continued...
--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:15:25+01:00 DST


O&M #398
%%DSP SENSOR:;%%
RETCODE = 0 Operation succeeded

The result is as follows


------------------------
Subrack number Slot number Rack number Position number Location Sensor name
Sensor value

0 4 0 2 Front FRU0 Hot Swap


[M4 - FRU Active]
0 4 0 2 Front FRU1 Hot Swap
[M4 - FRU Active]
0 4 0 2 Front FRU2 Hot Swap
[M4 - FRU Active]
0 4 0 2 Front FW Status
No state assertion event.
0 4 0 2 Front IPMB Link
State [IPMB-A enabled,IPMB-B enabled]
0 4 0 2 Front Memory Status
No state assertion event.
0 4 0 2 Front Mgmt Sys
Health No state assertion event.
0 4 0 2 Front Offline
Button No state assertion event.
0 4 0 2 Front Post Error
No state assertion event.
0 4 0 2 Front Power
228.000 Watts
0 4 0 2 Front Power Good
No state assertion event.
0 4 0 2 Front Slot Num
No state assertion event.
0 4 0 2 Front VTT_DDR_AB
0.672 Volts
0 4 0 2 Front VTT_DDR_EF
0.672 Volts
0 4 0 2 Front Ver. Change
No state assertion event.
0 4 0 2 Front Watchdog
No state assertion event.
0 4 0 2 Front X86 Restart
No state assertion event.
0 5 0 2 Front +0.9VCC
0.921 Volts
0 5 0 2 Front +1.05VCC
1.078 Volts
0 5 0 2 Front +1.0VCC_A
1.009 Volts
0 5 0 2 Front +1.0VCC_C
1.019 Volts
0 5 0 2 Front +1.0VCC_E
1.009 Volts
0 5 0 2 Front +1.2VCC_A
1.225 Volts
0 5 0 2 Front +1.2VCC_B
1.205 Volts
0 5 0 2 Front +1.2VSB
1.205 Volts
0 5 0 2 Front +1.5VCC_A
1.519 Volts
0 5 0 2 Front +1.8VCC_A
1.833 Volts
0 5 0 2 Front +1.8VCC_D
1.803 Volts
0 5 0 2 Front +12V_HDD
11.844 Volts
0 5 0 2 Front +2.5VCC_A
2.519 Volts
0 5 0 2 Front +3.0V_BAT
3.156 Volts
0 5 0 2 Front +3.3VCC_D
3.352 Volts
0 5 0 2 Front +5.0VSB
5.004 Volts
0 5 0 2 Front -48V Power1
No state assertion event.
0 5 0 2 Front -48V Power2
No state assertion event.
0 5 0 2 Front ACPI Status
[S0 / G0 "working"]
0 5 0 2 Front Base OS Boot
No state assertion event.
0 5 0 2 Front Board Status
No state assertion event.
0 5 0 2 Front Board Temp
39.000 degrees C
0 5 0 2 Front Board
Unstable No state assertion event.
0 5 0 2 Front Brd Inlet
Temp 28.000 degrees C
0 5 0 2 Front CPU1 Core Rem
-55.000 degrees C
0 5 0 2 Front Chassis
Status No state assertion event.
0 5 0 2 Front Clock Signal
A No state assertion event.
0 5 0 2 Front Clock Signal
B No state assertion event.
0 5 0 2 Front FRU0 Hot Swap
[M4 - FRU Active]
0 5 0 2 Front FRU1 Hot Swap
[M4 - FRU Active]
0 5 0 2 Front FRU2 Hot Swap
[M4 - FRU Active]
0 5 0 2 Front FW Status
No state assertion event.
0 5 0 2 Front Failover ASIC
No state assertion event.
0 5 0 2 Front IPMB Link
State [IPMB-A enabled,IPMB-B enabled]
0 5 0 2 Front LSW Temp
52.000 degrees C
0 5 0 2 Front Memory Status
No state assertion event.
0 5 0 2 Front Mgmt Sys
Health No state assertion event.
0 5 0 2 Front NIC Status
No state assertion event.
0 5 0 2 Front OAM Status
No state assertion event.
0 5 0 2 Front OS Stop
No state assertion event.
0 5 0 2 Front Offline
Button No state assertion event.
0 5 0 2 Front PPC Memory
No state assertion event.
0 5 0 2 Front PPC Post
Error No state assertion event.
0 5 0 2 Front PPC Restart
No state assertion event.
0 5 0 2 Front PPC Status
No state assertion event.
0 5 0 2 Front PPC Watchdog
No state assertion event.
0 5 0 2 Front Power
105.000 Watts
0 5 0 2 Front Power Good A
No state assertion event.
0 5 0 2 Front Power Good B
No state assertion event.
0 5 0 2 Front SAS
Controller No state assertion event.
0 5 0 2 Front SAS Temp
50.000 degrees C
0 5 0 2 Front Slot Num
No state assertion event.
0 5 0 2 Front Update Chan
No state assertion event.
0 5 0 2 Front Ver. Change
No state assertion event.
0 5 0 2 Front X86 Boot
Error No state assertion event.
0 5 0 2 Front X86 CPU1
Status No state assertion event.
0 5 0 2 Front X86 Post
Error No state assertion event.
0 5 0 2 Front X86 Restart
No state assertion event.
0 5 0 2 Front X86 Watchdog
No state assertion event.
0 6 0 2 Front +1.0VSB_PCH
0.992 Volts
0 6 0 2 Front +1.8VSB
1.808 Volts
0 6 0 2 Front +3.0V_BAT
3.096 Volts
0 6 0 2 Front +3.3VCC
3.264 Volts
0 6 0 2 Front +3.3VSB
3.296 Volts
0 6 0 2 Front +5.0VCC
4.992 Volts
0 6 0 2 Front -48V Power1
No state assertion event.
0 6 0 2 Front -48V Power2
No state assertion event.
0 6 0 2 Front ACPI Status
[S0 / G0 "working"]
0 6 0 2 Front Board Status
No state assertion event.
0 6 0 2 Front Board
Unstable No state assertion event.
0 6 0 2 Front Boot Error
No state assertion event.
0 6 0 2 Front Brd Inlet
Temp 27.000 degrees C
0 6 0 2 Front Brd Outlet
Temp 39.000 degrees C
0 6 0 2 Front CPU1 Core Rem
-46.000 degrees C
0 6 0 2 Front CPU1 Status
No state assertion event.
0 6 0 2 Front CPU2 Core Rem
-45.000 degrees C
0 6 0 2 Front CPU2 Status
No state assertion event.
0 6 0 2 Front Clock Signal
No state assertion event.
0 6 0 2 Front FRU0 Hot Swap
[M4 - FRU Active]
0 6 0 2 Front FRU1 Hot Swap
[M4 - FRU Active]
0 6 0 2 Front FRU2 Hot Swap
[M4 - FRU Active]
0 6 0 2 Front FW Status
No state assertion event.
0 6 0 2 Front IPMB Link
State [IPMB-A enabled,IPMB-B enabled]
0 6 0 2 Front Memory Status
No state assertion event.
0 6 0 2 Front Mgmt Sys
Health No state assertion event.
0 6 0 2 Front Offline
Button No state assertion event.
0 6 0 2 Front Post Error
No state assertion event.
0 6 0 2 Front Power
240.000 Watts
0 6 0 2 Front Power Good
No state assertion event.
0 6 0 2 Front Slot Num
No state assertion event.
0 6 0 2 Front VTT_DDR_AB
0.672 Volts
0 6 0 2 Front VTT_DDR_EF
0.672 Volts
0 6 0 2 Front Ver. Change
No state assertion event.
0 6 0 2 Front Watchdog
No state assertion event.
0 6 0 2 Front X86 Restart
No state assertion event.
(Number of results = 112)

2 reports in total
--- END

+++ CGP/*MEID:0 MENAME:brnt-asbccgf-3*/ 2022-05-13 09:15:34+01:00 DST


O&M #408
%%DSP MODULE:;%%
RETCODE = 0 Operation succeeded

Board module information


------------------------
Subrack number Slot number Rack number Position number Location ME ID
Module number Module type Active/Standby state Availability state Memory
allocated (KB) Memory usage (%) CPU usage (%) Administrative state

0 1 0 2 Front 0 501
IMU Active Normal 83294 65
11 Unsupported
0 1 0 2 Front 0 1001
PMU Active Normal 226654 89
6 Unsupported
0 1 0 2 Front 450 1
CDB Active Normal 2621690 77
6 Unlock
0 1 0 2 Front 450 11
SEM Active Normal 1048826 86
4 Unlock
0 1 0 2 Front 450 101
CMU Active Normal 1048826 74
2 Unlock
0 1 0 2 Front 450 102
CMU Active Normal 1048826 74
2 Unlock
0 1 0 2 Front 450 151
HRU Active Normal 20972794 74
7 Unlock
0 1 0 2 Front 450 201
PCU Active Normal 2107642 37
3 Unlock
0 1 0 2 Front 450 251
BSU Active Normal 1048826 72
8 Unlock
0 1 0 2 Front 450 252
BSU Active Normal 1048826 72
8 Unlock
0 1 0 2 Front 450 301
HMU Active Normal 524538 17
3 Unlock
0 1 0 2 Front 450 401
SCU Active Normal 4370682 76
8 Unlock
0 1 0 2 Front 450 402
SCU Active Normal 4370682 76
9 Unlock
0 1 0 2 Front 450 403
SCU Active Normal 4370682 76
8 Unlock
0 1 0 2 Front 450 404
SCU Active Normal 4370682 76
9 Unlock
0 1 0 2 Front 450 405
SCU Active Normal 4370682 76
8 Unlock
0 1 0 2 Front 450 406
SCU Active Normal 4370682 76
8 Unlock
0 1 0 2 Front 450 407
SCU Active Normal 4370682 76
9 Unlock
0 1 0 2 Front 450 408
SCU Active Normal 4370682 76
8 Unlock
0 2 0 2 Front GPC 0 502
IMU Active Normal 83294 65
2 Unsupported
0 2 0 2 Front GPC 0 1002
PMU Active Normal 226654 90
3 Unsupported
0 3 0 2 Front 0 503
IMU Active Normal 83294 65
10 Unsupported
0 3 0 2 Front 0 1003
PMU Active Normal 226654 89
5 Unsupported
0 3 0 2 Front 450 103
CMU Standby Normal 1048826 74
1 Unlock
0 3 0 2 Front 450 104
CMU Standby Normal 1048826 74
1 Unlock
0 3 0 2 Front 450 152
HRU Standby Normal 12584186 71
5 Unlock
0 3 0 2 Front 450 202
PCU Standby Normal 2107642 37
2 Unlock
0 3 0 2 Front 450 255
BSU Active Normal 1048826 72
7 Unlock
0 3 0 2 Front 450 256
BSU Active Normal 1048826 72
6 Unlock
0 3 0 2 Front 450 305
HMU Active Normal 524538 17
3 Unlock
0 3 0 2 Front 450 411
SCU Standby Normal 4370682 76
2 Unlock
0 3 0 2 Front 450 412
SCU Standby Normal 4370682 76
3 Unlock
0 3 0 2 Front 450 413
SCU Standby Normal 4370682 76
3 Unlock
0 3 0 2 Front 450 414
SCU Standby Normal 4370682 76
3 Unlock
0 3 0 2 Front 450 415
SCU Standby Normal 4370682 76
2 Unlock
0 3 0 2 Front 450 416
SCU Standby Normal 4370682 76
3 Unlock
0 3 0 2 Front 450 417
SCU Standby Normal 4370682 76
3 Unlock
0 3 0 2 Front 450 418
SCU Standby Normal 4370682 76
2 Unlock
0 3 0 2 Front 450 419
SCU Standby Normal 4370682 76
2 Unlock
0 3 0 2 Front 450 420
SCU Standby Normal 4370682 76
3 Unlock
0 3 0 2 Front 450 421
SCU Standby Normal 4370682 76
2 Unlock
0 4 0 2 Front 0 504
IMU Active Normal 83294 56
11 Unsupported
0 4 0 2 Front 0 1004
PMU Active Normal 226654 72
6 Unsupported
0 4 0 2 Front 450 1
CDB Standby Normal 2621690 77
3 Unlock
0 4 0 2 Front 450 11
SEM Standby Normal 1048826 86
3 Unlock
0 4 0 2 Front 450 101
CMU Standby Normal 1048826 74
2 Unlock
0 4 0 2 Front 450 102
CMU Standby Normal 1048826 74
1 Unlock
0 4 0 2 Front 450 151
HRU Standby Normal 20972794 74
6 Unlock
0 4 0 2 Front 450 201
PCU Standby Normal 2107642 37
3 Unlock
0 4 0 2 Front 450 253
BSU Active Normal 1048826 72
7 Unlock
0 4 0 2 Front 450 254
BSU Active Normal 1048826 72
7 Unlock
0 4 0 2 Front 450 303
HMU Active Normal 524538 17
3 Unlock
0 4 0 2 Front 450 401
SCU Standby Normal 4370682 76
3 Unlock
0 4 0 2 Front 450 402
SCU Standby Normal 4370682 76
2 Unlock
0 4 0 2 Front 450 403
SCU Standby Normal 4370682 76
3 Unlock
0 4 0 2 Front 450 404
SCU Standby Normal 4370682 76
3 Unlock
0 4 0 2 Front 450 405
SCU Standby Normal 4370682 76
3 Unlock
0 4 0 2 Front 450 406
SCU Standby Normal 4370682 76
3 Unlock
0 4 0 2 Front 450 407
SCU Standby Normal 4370682 76
3 Unlock
0 4 0 2 Front 450 408
SCU Standby Normal 4370682 76
3 Unlock
0 5 0 2 Front GPC 0 505
IMU Active Normal 83294 65
2 Unsupported
0 5 0 2 Front GPC 0 1005
PMU Active Normal 226654 90
3 Unsupported
0 6 0 2 Front 0 506
IMU Active Normal 83294 65
10 Unsupported
0 6 0 2 Front 0 1006
PMU Active Normal 226654 89
6 Unsupported
0 6 0 2 Front 450 103
CMU Active Normal 1048826 74
2 Unlock
0 6 0 2 Front 450 104
CMU Active Normal 1048826 74
2 Unlock
0 6 0 2 Front 450 152
HRU Active Normal 12584186 71
8 Unlock
0 6 0 2 Front 450 202
PCU Active Normal 2107642 37
4 Unlock
0 6 0 2 Front 450 257
BSU Active Normal 1048826 72
8 Unlock
0 6 0 2 Front 450 258
BSU Active Normal 1048826 72
8 Unlock
0 6 0 2 Front 450 307
HMU Active Normal 524538 17
3 Unlock
0 6 0 2 Front 450 411
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 412
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 413
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 414
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 415
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 416
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 417
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 418
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 419
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 420
SCU Active Normal 4370682 76
9 Unlock
0 6 0 2 Front 450 421
SCU Active Normal 4370682 76
8 Unlock