2022-MRV South & Southeast Asia-Edit (High Res.)
2022-MRV South & Southeast Asia-Edit (High Res.)
2022-MRV South & Southeast Asia-Edit (High Res.)
iall A C
2022
02
022
2 South & Southeast Asiaa
MR
M
MRV
RV
RV
2022 South & Southeast Asia
ADDRESS
No.1 Haier Road, Hi-tech Zone, Qingdao 266101 P.R.China
CONTACTS
Tel: +86-532-8893-6938
B2B Website: www.haierac.com
B2C Website: www.haier.com
Haier has owned 10+N R&D centers, 25 industrial park, 122 factories, 106 marketing centers across the world, and the 5002020
Haier has seven major household appliance brands across the world: Haier, Casarte, Leader, AQUA, Fisher & Paykel, GE
Appliances (GEA) and CANDY. All these brands together have constituted Haier’ s global brand cluster, which can fully
meet the best experience of different consumer groups in different regions all across the world.
The world's only ecosystem Haier has ranked No.1 Global Haier Smart Home was In 2020,Haier Smart Home
brand for three consecutive Major Appliance Brand for 12 named one of Fortune’ s was once again listed on the
years. consecutive years.Source most admired companies in Fortune Global 500, ranking
from Euromonitor2020. the world. 13 up from last year.
GE Appliance Park, Louisville, U.S. Turkey Factory Italy Factory Refrigerator Factory in Romania Russia Smart Ecosystem Industrial Park Phase II of Smart Ecosystem Vietnam Factory
Industrial Park in Russia
Europe
x4 x42 x2 x10
North America Asia
x2 x3 x2 x9 Japan R&D Center Japan IoT Laundry Factory
x6 x53 x21 x83
Middle E
Middl Eastt & Africa
Af i
x3 x1 x3
Latin America
AUS & NZL
AC Factory in Egypt
x1 x2 x10
x1 x7 x7
10+N
R&D Centers
108
Marketing Centers
28
Industrial Parks
122
Factories
160+
Countries or Regions
China, Haier runs another 8 overseas air conditioner factories. These factories have a total production capacity of
The First Batch Chinese local enterprise selected as
over 27.2 million units per year.
"Lighthouse Factory "
in the world
Dalian
Jiaozhou
Chongqing MHAQ
Wuhan
Tunisia
India
Algeria
Thailand
Pakistan Bangladesh
Nigeria Vietnam
R&D Center
Haier Air Conditioning R&D Center, located in Qingdao, China, completed in December 2013, covers 20,000 square In April 2014, Haier established joint laboratories with Highly for research in heating & cooling technology and with
meters. It has more than 120 laboratories, including testing laboratories, key part research laboratories and all-weather Mitsubishi Electric for innovative technology for user experience. Research by the user experience center covers the
user experience simulation laboratories. The R&D center also has the world tallest “drop tower” for testing long fields of user comfort evaluation, aerodynamics, acoustics, EMC(Electro-Magnetic Compatibility) and mechanics etc.
refrigerant piping tests(106 meters tall). The labs can carry out more than 600 international tests as per ISO, IEC, EN, CISPR and ANSI etc. to meet the
requirements of Europe, Asia, America, Australia, Middle East and other 100 countries and regions.
The user experience center gains recognition by domestic well-known certification and testing institutions, also is
recognized by international organizations like TUV and Intertek etc. At Haier, we believe that the best air conditioning is
one that builds on uncompromising quality control worldwide, developing and manufacturing fine products and delivering
them to customers everywhere.
R&D Labs
R&
EMC test Simulated Enthalpy-difference Safe Test Acoustic Labs Centralized control
Rainfall Test test
Global Certification
G
f
MRV Milestone
Haier AC has been holding No.1 market share in Pakistan for 5 consecutive years from 2009.
Haier AC was ranked NO.5 in Italy by market share in volume in 2012 & 2013 by DATABANK.
Haier B2C website in Italy was awarded “Interactive Key Award 2013” .
OFFICE
OFFICE
HOSPITAL
FACTORY
+
• 001 • • 002 •
PRODUCT LINE-UP Outdoor Units
Series HP 8~16 18~26 28~32 34 36~52 54~78 80~104 106 108 110 112~136
MRV 5 3/380~415/50/60
Series HP 3 4 5 6 7 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36
MRV SI 1/220~240/50/60
1/220~240/50/60
1/220~240/50/60
MRV SII
3/380~415/50/60
3/380~415/50/60
MRV W 3/380-415/50/60
EASY MRV
Connection Kit
• 003 • • 004 •
PRODUCT LINE-UP Indoor Units
KBTU/h 5 7 9 12 16 18 24 28 30 38 42 48 54 72 96
Series
kW 1.5 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 12.5 14.0 16.0 22.6 28.0
AB**2MCERA
4- Way Cassette
AB**2MNERA
Convertible AC**2MDERA
/ &8
/&8
/& 8
AD**2MSERA(D)
Low ESP Slim Duct (0/15/30Pa) AD**2MSERA
/ &8
/&8
/& 8
• 005 • • 006 •
PRODUCT LINE-UP Indoor Units
KBTU/h 5 7 9 12 16 18 24 28 30 38 42 48 54 72 96
Series
kW 1.5 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 12.5 14.0 16.0 22.6 28.0
/ &8
/&8
/& 8
Console AF**2MBERA
AS**2MNERAB
AS**2MNERA
AS**2MNERAC (NEW)
High Wall
AS**2MFERAB
AS**2MFERA
AS**2MFERAC(NEW)
/ &8
/&8
/& 8
150m3/h 800m3/h
HRV (Heat ReclaimVentalation)
260m3/h 1000m3/h
ERV***ANW
500m3/h
• 007 • • 008 •
011 Features & Benefits
016 MRV 5 Outdoor
029 Dimensions
n
atio
Install
Easy
ort
omf
er C
Sup
ncy
Efficie
High
logy
echno
anced T
Adv
• 009 • • 010 •
ADVANCED TECHNOLOGY
Total pipe length 1000m, height drop 110m
•Max. total pipe length 1000m Max. total pipe length
1000m
•Max. actual pipe length 220m
•Max. equivalent pipe length 260m
•Max. drop between IDU&ODU / 90m (outdoor unit up) / 110m 30m 110m
(outdoor unit down)
•Max. drop between IDU&IDU 30m*
* if the total pipe length is between 300m and 1100m or the drop between IDU
and ODU more than 50m, please contact your local dealer.
Single way total pipe length (=total liquid pipe length) 1000m L1+L2+L3+L4+L5+L6+L7+L8
+L9+L10+L11+L12+L13+L14+L15
Single way max. pipe length (max. length between
outdoor & indoor) actual length 220m L1+ L3+ L5+ L7+ L14+ L13
h1.
Main pipe actual length (length between first
gather pipe & first branch pipe) 130m L5
H1.
L1 L3 L5 L10 the farthest indoor
B
C
Pipe length among outdoor units (length between
10m L1+L3
L9 first gather pipe & farthest outdoor unit)
h2.
L11
L7 L12 L13 Height difference between indoors 18m h2
D E
H2
L14 L15 5m h1
Height difference between outdoors
F
MRV 5
* Class 3000 EEV customized for outdoor unit and Class 2000 EEV customized for indoor unit
Advanced Te
chnology
High Efficiency
Super Comfort
Easy Installation
HIGH EFFICIENCY
Super efficiency with full DC inverter compressor
Exhaust temperature sensor
Smart link We adopted High pressure chamber Each compressor is adopted oil temperature sensor
compressor, and low oil rate structure
Wireless connection and communication between indoor units. design, to ensure the reliable oil supply of and the discharge temperature sensor, detecting the
MRV 5
the compressor, and lubricate all parts
Three stage oil return inside the
•Labor saving effectively
compressor:
discharge temperature and oil temperature of
•Gravity oil return
•Automatic network connection •Centrifugal oil return compressor, cooperated with the compressor
Adopt new type oil cup design, reduce the •Structure shelter oil return
•Convenient maintenance disturbance of high speed rotation to oil frequency and the EEV control, to ensure exhaust
level, also reduce the oil discharge, improve
•Stable performance lubrication efficiency, reduce frictional loss
Oil temperature sensor heat and oil temperature superheat kept within the
•Total Cost saving is about 30% optimal range. Ensure that the oil dilution is maintained
at a safe level at all times.
• 011 • • 012 •
HIGH EFFICIENCY SUPER COMFORT
Speedless inverter DC-motor Intelligent triple backup operation technology
Outdoor unit matches efficient variable-speed DC-motor. •For the double-compressor system, when one compressor breakdown, the other compressor can be put into backup
drived by sine wave, wider efficiency range and torque range, operation immediately to ensure the user needs.
motor efficiency is increased by 17%. air fan of outdoor unit can •For the multi-module combination, in case of breakdown of one outdoor unit, this unit can be interrupted from the
achieve 0~91Hz stepless frequency. system so that the other modules can continue to operate.
•Super-long backup operation time, which can reach up to 8 hours.
Temperature approaching technology CM1 CM2 CM1 CM2 CM1 CM2 CM3
the room temperature reaches the setting temperature and control Temperature
setting
max
restarting when the same becomes higher than the setting method
Compressor 0
temperature. Though the inverter technology has improved speed Multiple modes available to meet the needs of different users
such a problem greatly, the energy consumption caused by
system restart is still a problem that cannot be ignored. 38% Power
consumption
reduced Operation mode: Silent mode: Static pressure mode:
No static pressure mode, low static
Cooling priority, heating priority, Seven-position silent mode
Haier MRV 5 series units adopts the temperature approaching cooling only, heating only, and available (nighttime silent mode pressure mode, medium static
technology, which enables the VRF system to maintain a Room VIP priority and six-position silent mode) pressure mode, and high static
temperature pressure mode
Temperature
low-frequency operating state all the time when the room approach Temperature
setting
temperature is close to the setting temperature but don’ t technology
max
Compressor 0
reach the setting temperature, thus avoiding the energy waste speed
Continuous running
Wide operation temperature Cooling 50°C DB
Limiting cooling 21°C DB Heating
MRV 5
Common control
With twin pressure sensors and twin EEVS, the refrigerant volume
Set temperature
Comfortable
can be adjusted automatically to realize precise temperature
control, improving indoor comfort. ±.°C
Smaller
temp.
fluctuation
Too cold
• 013 • • 014 •
EASY INSTALLATION
Auto addressing indoor units
The ODU can automatically address to the indoor unit through
the module on PCB, and the controller can search and set the
Auto
addressing
4
Auto
addressing
5
Auto
3/380~415/50/60
addressing
6
Auto
addressing
Auto
addressing
AV08IMVEVS AV18IMVEVS
2 3
AV10IMVEVS AV20IMVEVS
AV12IMVEVS AV22IMVEVS
AV14IMVEVS AV24IMVEVS
AV16IMVEVS AV26IMVEVS
/ / / / /
Without oil balancing pipe, the oil is balanced automatically.
/ / / / /
This simplifies system design and improves reliability. Combination model
/ / / / /
/ / / / /
Capacity range HP 8 10 12 14 16
Capacity
Cooling kW 25.2 28.0 33.5 40.0 45.0
No additional oil
balance pipe required
Heating kW 27.0 31.5 37.5 45.0 50.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Automatic snow clearing and dust Rated power input kW 5.60 6.80 8.40 10.90 11.80
Max power input kW 12.000 12.900 13.800 16.400 19.200
removal function Cooling
Rated current A 9.45 11.48 14.18 18.40 19.92
According to the ash accumulation on the outdoor heat Max current A 20.26 21.78 23.30 27.69 32.41
exchanger, the unit will blow away the dust, according to the Electrical
parameters Rated power input kW 5.20 6.30 8.00 10.30 11.20
reverse operation of the fan. Max power input kW 10.90 12.20 12.50 15.10 18.40
Heating
Rated current A 8.78 10.64 13.51 17.39 18.91
Max current A 18.40 20.60 21.10 25.49 31.06
EER 4.50 4.12 3.99 3.67 3.81
COP 5.19 5.00 4.69 4.37 4.46
Piping refrigerant storage technology Air flow (H) 11000 11000 12000 13500 13500
stored in the indoor and outdoor machine piping, remove the Sound power level (H) m³/h 67 67 70 70 71
high pressure tank, less refrigerant filling in unit, high efficiency. External dimensions(W/D/H) dB(A) 980/750/1690
MRV 5
External static pressure Pa 110 110 110 110 110
• 015 • • 016 •
Model AV18IMVEVS AV20IMVEVS AV22IMVEVS AV24IMVEVS AV26IMVEVS AV28IMVEVS AV30IMVEVS AV32IMVEVS
3/380~415/50/60
HP 18 20 22 24 26 28 30 32
Capacity Cooling kW 50.4 56.0 61.5 68.0 73.5 80.0 85.0 90.0
Heating kW 56.5 61.5 69.0 73.0 82.5 90.0 95.0 100.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 14.30 15.10 16.50 17.60 18.80 21.80 22.70 23.60
Max power input kW 21.400 25.100 28.500 29.100 33.000 32.800 35.600 38.400
Cooling Rated current A 24.14 25.49 27.86 29.71 31.74 36.80 38.32 39.84
Max current A 36.13 42.37 48.11 49.13 55.80 55.37 60.10 64.83
Rated power input kW 13.40 14.60 15.40 16.80 17.70 20.60 21.50 22.40
Electrical
parameters Max power input kW 17.70 22.70 25.50 26.50 30.40 30.20 33.50 36.80
Heating
Rated current A 22.62 24.65 26.00 28.36 29.88 34.78 36.30 37.82
Max current A 29.88 38.32 43.05 44.74 51.32 50.98 56.55 62.13
EER 3.52 3.71 3.73 3.86 3.91 3.67 3.74 3.81
AV08IMVEVS AV18IMVEVS COP 4.22 4.21 4.48 4.35 4.66 4.37 4.42 4.46
AV10IMVEVS AV20IMVEVS Air flow (H) 17000 17000 18000 18000 19000 27000 27000 27000
AV12IMVEVS AV22IMVEVS Performance Sound pressure level (H) 61 61 61 62 62 62 62.5 63
AV14IMVEVS AV24IMVEVS Sound power level (H) m³/h 72 72 72 73 73 73 73.5 74
AV16IMVEVS AV26IMVEVS
External dimensions(W/D/H) dB(A) 1410/750/1690 1410/750/1690 980/750/1690+980/750/1690
Shipping dimensions(W/D/H) dB(A) 1515/850/1858 1515/850/1858 1070/850/1858+1070/850/1858
Net/Shipping weight mm 287/317 370/400 370/400 370/400 370/400 244/270+244/270 244/270+244/270 244/270+244/270
Compressor type mm DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL
Auto
addressing5
Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18
Auto
Auto
addressing2
addressing6
Auto
addressing3
External static pressure Pa 110 110 110 110 110 110 110 110
Connection Connectable indoor unit ratio
MRV 5
Total pipe length 1000m, Auto addressing ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
height drop 110m indoor units Maximum number of indoor units 30 33 36 40 43 47 50 53
Cooling °C -5~50 -5~50
Working
temp. Heating °C -23~21 -23~21
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
Space saving Better cooling capacity * All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 017 • • 018 •
Model AV34IMVEVS AV36IMVEVS AV38IMVEVS AV40IMVEVS AV42IMVEVS AV44IMVEVS AV46IMVEVS
/ / / / / / /
Capacity range 36 38 40 42 44 46
3/380~415/50/60
HP 34
Capacity Cooling kW 95.4 100.8 106.4 112.0 117.5 123.0 129.5
Heating kW 106.5 113.0 118.0 123.0 130.5 138.0 142.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 26.10 28.60 29.40 30.20 31.60 33.00 34.10
Max power input kW 40.600 42.800 46.500 50.200 53.60 57.00 57.60
Cooling Rated current A 44.06 48.28 49.63 50.98 53.35 55.71 57.57
Max current A 68.54 72.26 78.50 84.75 90.49 96.23 97.24
Rated power input kW 24.60 26.80 28.00 29.20 30.00 30.80 32.20
Electrical
parameters Max power input kW 36.10 35.40 40.40 45.40 48.20 51.00 52.00
Heating
Rated current A 41.53 45.24 47.27 49.30 50.65 52.00 54.36
Max current A 60.94 59.76 68.20 76.64 81.37 86.10 87.79
EER 3.66 3.52 3.62 3.71 3.72 3.73 3.80
AV08IMVEVS AV18IMVEVS COP 4.33 4.22 4.21 4.21 4.35 4.48 4.41
AV10IMVEVS AV20IMVEVS Air flow (H) 30500 34000 34000 34000 35000 36000 36000
AV12IMVEVS AV22IMVEVS Performance Sound pressure level (H) 63.5 64 64 64 64 64 64.5
AV14IMVEVS AV24IMVEVS Sound power level (H) m³/h 75 75 75 75 75
74.5
AV16IMVEVS AV26IMVEVS
External dimensions(W/D/H) dB(A) 980/750/1690+1410/750/1690 1410/750/1690+1410/750/1690
Shipping dimensions(W/D/H) dB(A) 1070/850/1858+1515/850/1858 1515/850/1858+1515/850/1858
Net/Shipping weight mm 244/270+287/317 287/317+287/317 287/317+370/400 370/400+370/400 370/400+370/400 370/400+370/400 370/400+370/400
Compressor type mm DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL
Auto
addressing5
Standard drop between I.U. *4 m 18 18 18 18 18 18 18
Auto
Auto
addressing2
addressing6
Auto
addressing3
External static pressure Pa 110 110 110 110 110 110 110
Connection Connectable indoor unit ratio
MRV 5
Total pipe length 1000m, Auto addressing ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130
height drop 110m indoor units Maximum number of indoor units 56 59 63 64 64 64 64
Cooling °C -5~50 -5~50
Working
temp. Heating °C -23~21 -23~21
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
Space saving Better cooling capacity * All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 019 • • 020 •
Model AV48IMVEVS AV50IMVEVS AV52IMVEVS AV54IMVEVS AV56IMVEVS AV58IMVEVS AV60IMVEVS AV62IMVEVS
3/380~415/50/60
HP 48 50 52 54 56 58 60 62
Capacity Cooling kW 136.0 141.5 147.0 151.2 156.8 162.4 168.0 173.5
Heating kW 146.0 155.5 165.0 169.5 174.5 179.5 184.5 192.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 35.20 36.40 37.60 42.90 43.70 44.50 45.30 46.70
Max power input kW 58.20 62.10 66.00 64.20 67.90 71.60 75.30 78.70
Cooling Rated current A 59.42 61.45 63.48 72.42 73.77 75.13 76.48 78.84
Max current A 98.25 104.93 111.60 108.38 114.63 120.88 127.12 132.86
Rated power input kW 33.60 34.50 35.40 40.20 41.40 42.60 43.80 44.60
Electrical
parameters Max power input kW 53.00 56.90 60.80 53.10 58.10 63.10 68.10 70.90
Heating
Rated current A 56.72 58.24 59.76 67.87 69.89 71.92 73.94 75.29
Max current A 89.48 96.06 102.64 89.64 98.08 106.53 114.97 119.69
EER 3.86 3.89 3.91 3.52 3.59 3.65 3.71 3.72
AV08IMVEVS AV18IMVEVS COP 4.35 4.51 4.66 4.22 4.21 4.21 4.21 4.30
AV10IMVEVS AV20IMVEVS Air flow (H) 36000 37000 38000 51000 51000 51000 51000 52000
AV12IMVEVS AV22IMVEVS Performance Sound pressure level (H) 65 65 65 65.8 65.8 65.8 65.8 65.8
AV14IMVEVS AV24IMVEVS Sound power level (H) m³/h 76 76 76 76.5 76.5 76.5 76.5 76.5
AV16IMVEVS AV26IMVEVS
External dimensions(W/D/H) dB(A) 1410/750/1690+1410/750/1690 1410/750/1690+1410/750/1690 1410/750/1690+1410/750/1690+1410/750/1690
Shipping dimensions(W/D/H) dB(A) 1515/850/1858+1515/850/1858 1515/850/1858+1515/850/1858 1515/850/1858+1515/850/1858+1515/850/1858
Net/Shipping weight mm 370/400+370/400 370/400+370/400 287/317+287/317+287/317 287/317+287/317+370/400 287/317+370/400+370/400 370/400+370/400+370/400 370/400+370/400+370/400
Compressor type mm DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL
Auto
addressing5
Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18
Auto
Auto
addressing2
addressing6
Auto
addressing3
External static pressure Pa 110 110 110 110 110 110 110 110
Connection Connectable indoor unit ratio
MRV 5
Total pipe length 1000m, Auto addressing ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
height drop 110m indoor units Maximum number of indoor units 64 64 64 64 64 64 64 64
Cooling °C -5~50 -5~50
Working
temp. Heating °C -23~21 -23~21
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
Space saving Better cooling capacity * All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 021 • • 022 •
Model AV64IMVEVS AV66IMVEVS AV68IMVEVS AV70IMVEVS AV72IMVEVS AV74IMVEVS AV76IMVEVS AV78IMVEVS
3/380~415/50/60
HP 64 66 68 70 72 74 76 78
Capacity Cooling kW 179.0 184.5 191.0 197.5 204.0 209.5 215.0 220.5
Heating kW 199.5 207.0 211.0 215.0 219.0 228.5 238.0 247.5
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 48.10 49.50 50.60 51.70 52.80 54.00 55.20 56.40
Max power input kW 82.10 85.50 86.10 86.70 87.30 91.20 95.10 99.00
Cooling Rated current A 81.20 83.57 85.42 87.28 89.14 91.16 93.19 95.21
Max current A 138.60 144.34 145.35 146.37 147.38 154.05 160.73 167.40
Rated power input kW 45.40 46.20 47.60 49.00 50.40 51.30 52.20 53.10
Electrical
parameters Max power input kW 73.70 76.50 77.50 78.50 79.50 83.40 87.30 91.20
Heating
Rated current A 76.64 78.00 80.36 82.72 85.09 86.61 88.12 89.64
Max current A 124.42 129.15 130.84 132.52 134.21 140.80 147.38 153.96
EER 3.72 3.73 3.77 3.82 3.86 3.88 3.89 3.91
AV08IMVEVS AV18IMVEVS COP 4.39 4.48 4.43 4.39 4.35 4.45 4.56 4.66
AV10IMVEVS AV20IMVEVS Air flow (H) 53000 54000 54000 54000 54000 55000 56000 57000
AV12IMVEVS AV22IMVEVS Performance Sound pressure level (H) 66.5 66.8 66.8 66.8 66.8
65.8 65.8 66
AV14IMVEVS AV24IMVEVS Sound power level (H) m³/h 77.5 77.8 77.8 77.8 77.7
76.5 76.5 77
AV16IMVEVS AV26IMVEVS 1410/750/1690+1410/750/1690+1410/750/1690 1410/750/1690+1410/750/1690+1410/750/1690
External dimensions(W/D/H) dB(A)
Shipping dimensions(W/D/H) dB(A) 1515/850/1858+1515/850/1858+1515/850/1858 1515/850/1858+1515/850/1858+1515/850/1858
Net/Shipping weight mm 370/400+370/400+370/400 370/400+370/400+370/400
Compressor type mm DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL
Auto
addressing5
Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18
Auto
Auto
addressing2
addressing6
Auto
addressing3
External static pressure Pa 110 110 110 110 110 110 110 110
Connection Connectable indoor unit ratio
MRV 5
Total pipe length 1000m, Auto addressing ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
height drop 110m indoor units Maximum number of indoor units 64 64 64 64 64 64 64 64
Cooling °C -5~50 -5~50
Working
temp. Heating °C -23~21 -23~21
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
Space saving Better cooling capacity * All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 023 • • 024 •
Model AV80IMVEVS AV82IMVEVS AV84IMVEVS AV86IMVEVS AV88IMVEVS AV90IMVEVS AV92IMVEVS
3/380~415/50/60
HP 80 82 84 86 88 90 92
Capacity Cooling kW 224.0 229.5 235.0 240.5 246.0 252.5 259.0
Heating kW 246.0 253.5 261.0 268.5 276.0 280.0 284.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 60.40 61.80 63.20 64.60 66.00 67.10 68.20
Max power input kW 100.40 103.80 107.20 110.60 114.00 114.60 115.20
Cooling Rated current A 101.97 104.33 106.69 109.06 111.42 113.28 115.14
Max current A 169.50 175.24 180.98 186.72 192.46 193.47 194.48
Rated power input kW 58.40 59.20 60.00 60.80 61.60 63.00 64.40
Electrical
parameters Max power input kW 90.80 93.60 96.40 99.20 102.00 103.00 104.00
Heating
Rated current A 98.59 99.94 101.29 102.64 103.99 106.36 108.72
Max current A 153.29 158.02 162.74 167.47 172.20 173.89 175.57
EER 3.71 3.71 3.72 3.72 3.73 3.76 3.80
AV08IMVEVS AV18IMVEVS COP 4.21 4.28 4.35 4.42 4.48 4.44 4.41
AV10IMVEVS AV20IMVEVS Air flow (H) 68000 69000 70000 71000 72000 72000 72000
AV12IMVEVS AV22IMVEVS Performance Sound pressure level (H) 67 67 67 67 67 67.5 67.5
AV14IMVEVS AV24IMVEVS Sound power level (H) m³/h 78 78 78 78 78 78.5 78.5
AV16IMVEVS AV26IMVEVS 1410/750/1690+1410/750/1690+1410/750/
External dimensions(W/D/H) dB(A) 1690+1410/750/1690 1410/750/1690+1410/750/1690+1410/750/1690+1410/750/1690
Shipping dimensions(W/D/H) dB(A) 1515/850/1858+1515/850/1858+1515/850/
1858+1515/850/1858 1515/850/1858+1515/850/1858+1515/850/1858+1515/850/1858
Net/Shipping weight mm 370/400+370/400+370/400+370/400 370/400+370/400+370/400+370/400
Compressor type mm DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL
Auto
addressing5
Standard drop between I.U. *4 m 18 18 18 18 18 18 18
Auto
Auto
addressing2
addressing6
Auto
addressing3
External static pressure Pa 110 110 110 110 110 110 110
Connection Connectable indoor unit ratio
MRV 5
Total pipe length 1000m, Auto addressing ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130
height drop 110m indoor units Maximum number of indoor units 64 64 64 64 64 64 64
Cooling °C -5~50 -5~50
Working
temp. Heating °C -23~21 -23~21
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
Space saving Better cooling capacity * All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 025 • • 026 •
Model AV94IMVEVS AV96IMVEVS AV98IMVEVS AV100IMVEVS AV102IMVEVS AV104IMVEVS
3/380~415/50/60
HP 94 96 98 100 102 104
Capacity Cooling kW 265.5 272.0 277.5 283.0 288.5 294.0
Heating kW 288.0 292.0 301.5 311.0 320.5 330.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 69.30 70.40 71.60 72.80 74.00 75.20
Max power input kW 115.80 116.40 120.30 124.20 128.10 132.00
Auto
addressing5
Standard drop between I.U. *4 m 18 18 18 18 18 18
Auto
Auto
addressing2
addressing6
Auto
addressing3
MRV 5
Total pipe length 1000m, Auto addressing ratio % 50~130 50~130 50~130 50~130 50~130 50~130
height drop 110m indoor units Maximum number of indoor units 64 64 64 64 64 64
Cooling °C -5~50 -5~50
Working
temp. Heating °C -23~21 -23~21
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
Space saving Better cooling capacity * All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 027 • • 028 •
Dimensions
AV08IMVEVS AV10IMVEVS AV12IMVEVS AV14IMVEVS AV16IMVEVS AV18IMVEVS AV20IMVEVS AV22IMVEVS AV24IMVEVS AV26IMVEVS
Unit:mm Unit:mm
100
Space between fixing holes 755
100
80
80
8 8
630
755
630
755
.
80
80
100
100
.
800 1000
980 1410
750 750
70
70
Air outlet Back 300
duct Back 300
connection
position
Right
Left
Air outlet duct
Right
Left
155
connection
155
300
300
1690
1690
position
300
300
Front
Front
822
822
1000
1000
198
198
122
122
1 2 3 4 5 6 7
1 2 3 4 5 6 7
2 Pipe outlet for 2-pipe system 2 Pipe outlet for 2-pipe system
3 Pipe outlet for 3-pipe system 3 Pipe outlet for 3-pipe system
According to the wire diameter size to choose the appropriate line According to the wire diameter size to choose the appropriate line
4 Power supply hole 4 Power supply hole
hole,and using the line sheath in the unit's attachment for protection hole,and using the line sheath in the unit's attachment for protection
MRV 5
6 Power supply of signal line hole
7 Refrigerant pipe outlet 7 Refrigerant pipe outlet
8 Drain hole 8 Drain hole
• 029 • • 030 •
033 Features & Benefits
035 MRV 5-T Outdoor
ort
omf
rC
pe
Su
ion
llat
Insta
sy
Ea
y
log
hno
ec
dT
ce
an
Adv
• 031 • • 032 •
EASY INSTALLATION
Cloud service
1. Remote monitor and control via PC, smartphone, tablet etc.
2. Scan the QR code to complete configuration and check the
status of the AC at any time and place.
3. Check real-time working status of AC by cloud service data
platform.
4. Convenient Scheduling and central control.
5. Smart detection, pre-alarm and self-diagnostic for malfunction.
6. Group/Zone control. Control temp. , mode, fan speed etc. of
each group/Zone flexibly.
Auto adjustment
After the system is installed, through ODU mainboard, the whole system can be adjusted, eliminate possible faults in the
system. More convenience.
SUPER COMFORT
MRV 5-T
Super Comfort
Quick start, strong cooling and heating
chnology Easy Installation Quick starting of turbo
Advanced Te
Quick start in 5s, achieve Maximum output in 70s. Maintain high cooling and heating
frequency operation for one hour, Ensure that the room of turbo
cooling and heating High frequency working
temperature reaches the maximum set value quickly. Max. output of normal
in 60 minutes
working
Starting in 5s,
full frequency working in 70s
*/7&35&3
Enhanced vapor Injection technology, low temperature heating and high Power cut memory function and restart
temperature cooling During opetation, if the system power off suddenly, the system
will automatically remember state before power off. When power
MRV 5-T
The unit adopts EVI compressor, which can increase the EVI compressor
Air injection pipe, high
Normal compressor
is restored, the system will start automatically and run in the original
refrigerant circulation by 15%, and improve the heating effect pressure side refrigerant
circulation increases
Pressure
by 30% compared with the normal type. Meanwhile, the one-way M+ M Refrigerant
increased
flow
valve built in, and the efficiency of the unit can be increased by M Gas
• 033 • • 034 •
Model AV08NMVETS AV10NMVETS AV12NMVETS AV14NMVETS AV16NMVETS AV18NMVETS AV20NMVETS AV22NMVETS AV24NMVETS AV26NMVETS
/ / / / / / / / / /
/ / / / / / / / / /
Combination model
/ / / / / / / / / /
/ / / / / / / / / /
3/380~415/50/60 Capacity
Capacity range
Cooling @T1
HP
kW
8
25.2
10
28.0
12
33.5
14
40.0
16
45.0
18
50.4
20
56.0
22
61.5 68.0
24 26
73.5
Heating kW 27.0 31.5 37.5 45.0 50.0 56.5 63.0 69.0 75.0 82.5
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 5.38 6.80 8.40 10.70 12.80 13.85 15.71 17.72 19.10 21.20
Cooling Rated current A 8.96 11.32 13.99 17.82 21.31 23.06 26.16 29.50 31.80 35.30
Max power input kW 14.30 15.10 16.32 17.58 20.69 25.90 28.91 31.82 32.81 35.35
Electrical A 40.30 46.30 51.91 54.12 58.86
parameters Max current 23.81 25.14 27.17 29.27 34.50
Rated power input kW 5.30 6.40 8.30 10.60 11.80 13.50 15.30 16.90 18.50 19.70
Heating Rated current A 8.82 10.66 13.82 17.65 19.65 22.48 25.47 28.14 30.80 32.80
AV08NMVETS AV18NMVETS
AV10NMVETS AV20NMVETS Max power input kW 11.69 12.19 12.69 16.10 19.56 21.93 24.70 25.69 30.40 32.45
AV12NMVETS AV22NMVETS Max current A 19.47 20.30 21.13 26.81 32.57 36.51 41.13 42.78 50.62 54.03
AV14NMVETS AV24NMVETS EER / 4.68 4.12 3.99 3.74 3.52 3.64 3.56 3.47 3.56 3.47
AV16NMVETS AV26NMVETS
COP / 5.09 4.92 4.52 4.25 4.24 4.19 4.12 4.08 4.05 4.19
Air flow (H) m³/h 11000 12000 13500 13500 13500 17000 17000 18000 18000 19000
Fan
External static pressure Pa 110 110 110 110 110 110 110 110 110 110
Refrigerant gas pipe mm 19.05 22.22 25.4 25.4 28.58 28.58 28.58 28.58 28.58 28.58
Pipe
AV
AV28NMVETS
V28NNMVETS Refrigerant liquid pipe mm 9.52 9.52 12.7 12.7 12.7 15.88 15.88 15.88 15.88 15.88
AV30NMVETS
AV 30NM
MVET
TS Sound Sound pressure level (H) dB(A) 57 57 59 59 60 61 62 62 63 63
AV32NMVETS
Connectable indoor unit ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
AV34NMVETS Connection
Ratio
Maximum number of indoor units 13 16 20 24 27 30 33 36 40 43
Max.total pipe length m 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Max. pipe length(Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U. 110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90
Max. PipeLength ( O.U. down/up) *1
1000 110m Auto
Standard drop between I.U.&O.U.
Auto
addressing1
Auto
addressing2
addressing4
Auto
addressing5
Auto
addressing6
( O.U. up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40 50/40 50/40 50/40 50/40
Auto
addressing3
MRV 5-T
Total pipe length 1000m, Auto addressing Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18 18 18
height drop 110m indoor units
Cooling ˚C -5~53 -5~53
Working
temp. -25~27
Heating ˚C -25~27
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
EVI compressors Maximum combination 136HP
• 035 • • 036 •
Model AV28NMVETS AV30NMVETS AV32NMVETS AV34NMVETS AV36NMVETS AV38NMVETS AV40NMVETS AV42NMVETS AV44NMVETS
/ / / / AV18NMVETS AV18NMVETS AV20NMVETS AV20NMVETS AV22NMVETS
/ / / / / / / / /
3/380~415/50/60 Capacity
Capacity range
Cooling
HP
kW
28
80.0
30
85.0
32
90.0
34
95.0
36
100.8
38
106.4
40
112.0
42
117.5
44
123.0
Heating kW 90.0 95.0 100.0 106.5 113.0 119.5 126.0 132.0 138.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 21.30 22.75 25.10 26.65 27.70 29.56 31.42 33.43 35.44
Cooling Rated current A 34.70 37.06 40.89 43.42 46.12 49.22 52.31 55.66 59.01
Max power input kW 35.60 36.41 37.62 42.98 51.80 54.81 57.82 60.73 63.64
Electrical A
parameters Max current 58.95 59.31 61.29 70.02 80.60 86.60 92.60 98.21 103.82
Rated power input kW 20.84 22.40 24.60 25.30 27.00 28.80 30.60 32.20 33.80
Heating Rated current A 33.95 36.49 40.08 41.22 44.96 47.95 50.95 53.61 56.28
AV08NMVETS AV18NMVETS
AV10NMVETS AV20NMVETS Max power input kW 32.60 33.10 33.50 37.38 43.86 46.63 49.40 50.39 51.38
AV12NMVETS AV22NMVETS Max current A 53.69 54.51 55.17 60.90 73.03 77.64 82.25 83.90 85.55
AV14NMVETS AV24NMVETS EER / 3.76 3.74 3.59 3.56 3.64 3.60 3.56 3.51 3.47
AV16NMVETS AV26NMVETS
COP / 4.32 4.24 4.07 4.21 4.19 4.15 4.12 4.10 4.08
External dimensions(W/D/H) mm 1785/830/1858 1785/830/1858 1410/750/1690+1410/750/1690
Dimensions
Shipping dimensions(W/D/H) mm 1886/950/2025 1886/950/2025 1515/850/1858+1515/850/1858
Air flow (H) m³/h 27000 27000 27000 27000 34000 34000 34000 35000 36000
Fan
External static pressure Pa 110 110 110 110 110 110 110 110 110
Refrigerant gas pipe mm 31.75 31.75 31.75 31.75 38.1 38.1 38.1 38.1 38.1
Pipe
AV
AV28NMVETS
V28NNMVETS Refrigerant liquid pipe mm 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
AV30NMVETS
AV 30NM
MVET
TS Sound Sound pressure level (H) dB(A) 63 64 64 64 64 64 64 64 64
AV32NMVETS
Connectable indoor unit ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
AV34NMVETS Connection
Ratio
Maximum number of indoor units 47 50 53 56 59 63 64 64 64
Max.total pipe length m 1000 1000 1000 1000 1000 1000 1000 1000 1000
Max. pipe length(Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U.
110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90
Max. Pipe Length ( O.U. down/up) *1
1000 110m Auto
Standard drop between I.U.&O.U.
Auto
addressing1
Auto
addressing2
Auto
addressing4
Auto
addressing5
Auto
addressing6
( O.U. up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40 50/40 50/40 50/40
addressing3
MRV 5-T
Total pipe length 1000m, Auto addressing Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18 18
height drop 110m indoor units
Cooling ˚C -5~53 -5~53
Working
temp. -25~27 -25~27
Heating ˚C
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
EVI compressors Maximum combination 136HP
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 037 • • 038 •
Model AV46NMVETS AV48NMVETS AV50NMVETS AV52NMVETS AV54NMVETS AV56NMVETS AV58NMVETS AV60NMVETS
AV22NMVETS AV24NMVETS AV24NMVETS AV26NMVETS AV18NMVETS AV18NMVETS AV18NMVETS AV20NMVETS
/ / / / / / / /
3/380~415/50/60 Capacity
Capacity range
Cooling
HP
kW
46
129.5
48
136.0
50
141.5
52
147.0
54
153.5
56
160.0 165.0
58 60
170.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 36.82 38.20 40.30 42.40 42.50 42.60 44.05 45.50
Cooling Rated current A 61.31 63.60 67.10 70.60 70.00 69.40 71.77 74.13
Max power input kW 64.63 65.62 68.16 70.70 70.95 71.20 72.01 72.81
Electrical A
parameters Max current 106.03 108.24 112.98 117.72 117.81 117.90 118.26 118.62
Rated power input kW 35.40 37.00 38.20 39.40 40.54 41.68 43.24 44.80
Heating Rated current A 58.94 61.61 63.60 65.60 66.75 67.90 70.45 72.99
AV08NMVETS AV18NMVETS
AV10NMVETS AV20NMVETS Max power input kW 56.09 60.80 62.85 64.90 65.05 65.20 65.70 66.20
AV12NMVETS AV22NMVETS Max current A 93.39 101.23 104.65 108.06 107.72 107.38 108.20 109.03
AV14NMVETS AV24NMVETS EER / 3.52 3.56 3.51 3.47 3.61 3.76 3.75 3.74
AV16NMVETS AV26NMVETS
COP / 4.07 4.05 4.12 4.19 4.26 4.32 4.28 4.24
Air flow (H) m³/h 36000 36000 37000 38000 46000 54000 54000 54000
Fan
External static pressure Pa 110 110 110 110 110 110 110 110
Refrigerant gas pipe mm 38.1 38.1 38.1 38.1 38.1 38.1 41.3 41.3
Pipe
AV
AV28NMVETS
V28NNMVETS Refrigerant liquid pipe mm 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
AV30NMVETS
AV 30NM
MVET
TS Sound Sound pressure level (H) dB(A) 64.5 65 65 65 65.8 65.8 65.8 65.8
AV32NMVETS
Connectable indoor unit ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
AV34NMVETS Connection
Ratio
Maximum number of indoor units 64 64 64 64 64 64 64 64
Max.total pipe length m 1000 1000 1000 1000 1000 1000 1000 1000
Max. pipe length(Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U.
110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90
Max. Pipe Length ( O.U. down/up) *1
1000 110m Auto
Standard drop between I.U.&O.U.
Auto
addressing1
Auto
addressing2
Auto
addressing4
Auto
addressing5
Auto
addressing6
( O.U. up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40 50/40 50/40
addressing3
MRV 5-T
Total pipe length 1000m, Auto addressing Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18
height drop 110m indoor units
Cooling ˚C -5~53 -5~53
Working
temp. -25~27 -25~27
Heating ˚C
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
EVI compressors Maximum combination 136HP
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 039 • • 040 •
Model AV62NMVETS AV64NMVETS AV66NMVETS AV68NMVETS AV70NMVETS AV72NMVETS AV74NMVETS AV76NMVETS AV78NMVETS
AV22NMVETS AV22NMVETS AV22NMVETS AV22NMVETS AV22NMVETS AV24NMVETS AV26NMVETS AV26NMVETS AV26NMVETS
/ / / / / / / / /
3/380~415/50/60 Capacity
Capacity range
Cooling
HP
kW
62
175.0
64
180.0
66
185.0
68
190.0
70
197.5
72
204.0
74
209.5
76
215.0
78
220.5
Heating kW 195.0 200.0 206.5 213.0 219.0 225.0 232.5 240.0 247.5
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 47.85 50.20 51.75 53.30 55.92 57.30 59.40 61.50 63.60
Cooling Rated current A 77.96 81.79 84.31 86.84 93.11 95.40 98.90 102.40 105.89
Max power input kW 74.02 75.24 80.60 85.96 97.44 98.43 100.97 103.51 106.05
Electrical A
parameters Max current 120.60 122.58 131.31 140.04 160.15 162.36 167.10 171.84 176.57
Rated power input kW 47.00 49.20 49.90 50.60 53.90 55.50 56.70 57.90 59.10
Heating Rated current A 76.57 80.16 81.30 82.44 89.74 92.41 94.41 96.40 98.40
AV08NMVETS AV18NMVETS
AV10NMVETS AV20NMVETS Max power input kW 66.60 67.00 70.88 74.76 86.49 91.20 93.25 95.30 97.35
AV12NMVETS AV22NMVETS Max current A 109.68 110.34 116.07 121.80 144.01 151.85 155.26 158.67 162.09
AV14NMVETS AV24NMVETS EER / 3.66 3.59 3.57 3.56 3.53 3.56 3.53 3.50 3.47
AV16NMVETS AV26NMVETS
COP / 4.15 4.07 4.14 4.21 4.06 4.05 4.10 4.15 4.19
Air flow (H) m³/h 54000 54000 54000 54000 54000 54000 55000 56000 57000
Fan
External static pressure Pa 110 110 110 110 110 110 110 110 110
Refrigerant gas pipe mm 41.3 41.3 41.3 44.5 44.5 44.5 44.5 44.5 44.5
Pipe
AV
AV28NMVETS
V28NNMVETS Refrigerant liquid pipe mm 19.05 19.05 19.05 22.2 22.2 22.2 22.2 22.2 22.2
AV30NMVETS
AV 30NM
MVET
TS Sound Sound pressure level (H) dB(A) 65.8 65.8 65.8 66 66.5 66.8 66.8 66.8 66.8
AV32NMVETS
Connectable indoor unit ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
AV34NMVETS Connection
Ratio
Maximum number of indoor units 64 64 64 64 64 64 64 64 64
Max.total pipe length m 1000 1000 1000 1000 1000 1000 1000 1000 1000
Max. pipe length(Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U.
110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90
Max. Pipe Length ( O.U. down/up) *1
1000 110m Auto
Standard drop between I.U.&O.U.
m 50/40 50/40 50/40 50/40
addressing4
Auto
addressing1
Auto
addressing2
Auto
addressing3
Auto
addressing5
Auto
addressing6
( O.U. up/down) *2 50/40 50/40 50/40 50/40 50/40
Max drop between I.U. *3 m 30 30 30 30 30 30 30 30 30
MRV 5-T
Total pipe length 1000m, Auto addressing Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18 18
height drop 110m indoor units
Cooling ˚C -5~53 -5~53
Working
temp.
Heating ˚C -25~27 -25~27
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
EVI compressors Maximum combination 136HP
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 041 • • 042 •
Model AV80NMVETS AV82NMVETS AV84NMVETS AV86NMVETS AV88NMVETS AV90NMVETS AV92NMVETS AV94NMVETS
AV20NMVETS AV20NMVETS AV20NMVETS AV20NMVETS AV22NMVETS AV24NMVETS AV24NMVETS AV24NMVETS
3/380~415/50/60 Capacity
Capacity range
Cooling
HP
kW
80
227.0
82
233.5
84
240.0
86
245.0
88
250.0
90
255.0
92
260.0
94
265.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 63.70 63.80 63.90 65.35 66.80 68.25 70.60 72.95
Cooling Rated current A 105.30 104.70 104.11 106.47 108.83 111.19 115.02 118.85
Max power input kW 106.30 106.55 106.80 107.61 108.41 109.22 110.43 111.64
Electrical A
parameters Max current 176.67 176.76 176.85 177.21 177.57 177.93 179.91 181.89
Rated power input kW 60.24 61.38 62.52 64.08 65.64 67.20 69.40 71.60
Heating Rated current A 99.55 100.71 101.86 104.40 106.94 109.48 113.07 116.65
AV08NMVETS AV18NMVETS
Max power input kW 97.50 97.65 97.80 98.30 98.80 99.30 99.70 100.10
AV10NMVETS AV20NMVETS
AV12NMVETS AV22NMVETS Max current A 161.75 161.41 161.07 161.89 162.71 163.54 164.20 164.86
AV14NMVETS AV24NMVETS EER / 3.56 3.66 3.76 3.75 3.74 3.74 3.68 3.63
AV16NMVETS AV26NMVETS
COP / 4.23 4.28 4.32 4.29 4.27 4.24 4.18 4.12
External dimensions(W/D/H) mm 1410/750/1690*4 1410/750/1690*4
Dimensions
Shipping dimensions(W/D/H) mm 1515/850/1858*4 1515/850/1858*4
Air flow (H) m³/h 65000 73000 81000 81000 81000 81000 81000 81000
Fan
External static pressure Pa 110 110 110 110 110 110 110 110
Refrigerant gas pipe mm 44.5 44.5 44.5 50.8 50.8 50.8 50.8 50.8
Pipe
AV
AV28NMVETS
V28NNMVETS Refrigerant liquid pipe mm 22.2 22.2 22.2 25.4 25.4 25.4 25.4 25.4
AV30NMVETS
AV 30NM
MVET
TS Sound Sound pressure level (H) dB(A) 67 67 67 67 67 67.5 67.5 68
AV32NMVETS
Connectable indoor unit ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
Connection
AV34NMVETS Ratio
Maximum number of indoor units 64 64 64 64 64 64 64 64
Max.total pipe length m 1000 1000 1000 1000 1000 1000 1000 1000
Max. pipe length(Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U. 110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90
Max. Pipe Length ( O.U. down/up) *1
1000 110m Standard drop between I.U.&O.U.
m 50/40 50/40 50/40
Auto
Auto
addressing1
Auto
addressing2
addressing4
Auto
addressing5
Auto
addressing6 ( O.U. up/down) *2 50/40 50/40 50/40 50/40 50/40
Auto
addressing3
MRV 5-T
Total pipe length 1000m, Auto addressing Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18
height drop 110m indoor units
Cooling ˚C -5~53 -5~53
Working
temp. -25~27
Heating ˚C -25~27
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
EVI compressors Maximum combination 136HP
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 043 • • 044 •
Model AV96NMVETS AV98NMVETS AV100NMVETS AV102NMVETS AV104NMVETS AV106NMVETS AV108NMVETS
AV24NMVETS AV26NMVETS AV26NMVETS AV26NMVETS AV26NMVETS AV26NMVETS AV26NMVETS
3/380~415/50/60 Capacity
Capacity range
Cooling
HP
kW
96
270.0
98
275.0
100
280.0
102
285.0
104
294.0
106
300.5
108
307.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 75.30 76.85 78.40 79.95 84.80 84.90 85.00
Cooling Rated current A 122.68 125.20 127.73 130.25 141.19 140.60 140.00
Max power input kW 112.86 118.22 123.58 128.94 141.40 141.65 141.90
Electrical A
parameters Max current 183.86 192.60 201.33 210.06 235.43 235.52 235.62
Rated power input kW 73.80 74.50 75.20 75.90 78.80 79.94 81.08
Heating Rated current A 120.23 121.38 122.52 123.66 131.20 132.35 133.51
AV08NMVETS AV18NMVETS
AV10NMVETS AV20NMVETS Max power input kW 100.50 104.38 108.26 112.14 129.80 129.95 130.10
AV12NMVETS AV22NMVETS Max current A 165.51 171.24 176.97 182.70 216.12 215.78 215.44
AV14NMVETS AV24NMVETS EER / 3.59 3.58 3.57 3.56 3.47 3.54 3.61
AV16NMVETS AV26NMVETS
COP / 4.07 4.11 4.16 4.21 4.19 4.22 4.26
External dimensions(W/D/H) mm 1410/750/1690*4 1410/750/1690*4 1410/750/1690+1410/750/1690+ 1410/750/1690+1410/750/1690+
Dimensions 1410/750/1690+1785/830/1858 1785/830/1858+1785/830/1858
Shipping dimensions(W/D/H) mm 1515/850/1858*4 1515/850/1858*4 1515/850/1858*3+1886/950/2025 1515/850/1858*3+1886/950/2025
Air flow (H) m³/h 81000 81000 81000 81000 76000 84000 92000
Fan
External static pressure Pa 110 110 110 110 110 110 110
Refrigerant gas pipe mm 50.8 54.1 54.1 54.1 54.1 66.7 66.7
Pipe
AV
AV28NMVETS
V28NNMVETS Refrigerant liquid pipe mm 25.4 25.4 25.4 25.4 25.4 28.58 28.58
AV30NMVETS
AV 30NM
MVET
TS Sound Sound pressure level (H) dB(A) 68 68 68 68 68 69.3 69.6
AV32NMVETS
Connectable indoor unit ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130
AV34NMVETS Connection
Ratio
Maximum number of indoor units 64 64 64 64 64 64 64
Max.total pipe length m 1000 1000 1000 1000 1000 1000 1000
Max. pipe length(Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U.
110/90 110/90 110/90 110/90 110/90 110/90 110/90
Max. Pipe Length ( O.U. down/up) *1
1000 110m Auto
Standard drop between I.U.&O.U.
m 50/40 50/40 50/40 50/40 50/40 50/40 50/40
addressing4
Auto
addressing1 Auto
( O.U. up/down) *2
addressing5
Auto
Auto
addressing2
addressing6
Auto
addressing3
MRV 5-T
Total pipe length 1000m, Auto addressing Standard drop between I.U. *4 m 18 18 18 18 18 18 18
height drop 110m indoor units
Cooling ˚C -5~53 -5~53
Working
temp. -25~27
Heating ˚C -25~27
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
EVI compressors Maximum combination 136HP
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 045 • •046 •
Model AV110NMVETS AV112NMVETS AV114NMVETS AV116NMVETS AV118NMVETS AV120NMVETS
AV26NMVETS AV28NMVETS AV28NMVETS AV28NMVETS AV30NMVETS AV30NMVETS
3/380~415/50/60 Capacity
Capacity range
Cooling
HP
kW
110
313.5
112
320.0
114
325.0
116
330.0
118
335.0
120
340.0
Air flow (H) m³/h 100000 108000 108000 108000 108000 108000
Fan
External static pressure Pa 110 110 110 110 110 110
Auto
addressing2
addressing4
Auto
addressing5
Auto
addressing6
( O.U. up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40
Auto
addressing3
MRV 5-T
Total pipe length 1000m, Auto addressing Standard drop between I.U. *4 m 18 18 18 18 18 18
height drop 110m indoor units
Cooling ˚C -5~53
Working
temp.
Heating ˚C -25~27
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
EVI compressors Maximum combination 136HP
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 047 • •048 •
Model AV122NMVETS AV124NMVETS AV126NMVETS AV128NMVETS AV130NMVETS AV132NMVETS AV134NMVETS AV136NMVETS
AV30NMVETS AV30NMVETS AV32NMVETS AV32NMVETS AV32NMVETS AV32NMVETS AV34NMVETS AV34NMVETS
3/380~415/50/60 Capacity
Capacity range
Cooling
HP
kW
122
345.0
124
350.0
126
355.0
128
360.0
130
365.0
132
370.0 375.0
134 136
380.0
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 93.35 95.70 98.05 100.40 101.95 103.50 105.05 106.60
Cooling Rated current A 152.09 155.91 159.74 163.57 166.10 168.62 171.15 173.67
Max power input kW 146.83 148.05 149.26 150.47 155.84 161.20 166.56 171.92
Electrical A 239.22 241.20 243.17 245.15
parameters Max current 253.88 262.62 271.35 280.08
Rated power input kW 91.80 94.00 96.20 98.40 99.10 99.80 100.50 101.20
Heating Rated current A 149.56 153.14 156.73 160.31 161.45 162.59 163.73 164.87
AV08NMVETS AV18NMVETS
AV10NMVETS AV20NMVETS Max power input kW 132.80 133.20 133.60 134.00 137.88 141.76 145.64 149.52
AV12NMVETS AV22NMVETS Max current A 218.71 219.37 220.03 220.69 226.41 232.14 237.87 243.60
AV14NMVETS AV24NMVETS EER / 3.70 3.66 3.62 3.59 3.58 3.57 3.57 3.56
AV16NMVETS AV26NMVETS
COP / 4.19 4.15 4.11 4.07 4.10 4.14 4.17 4.21
Air flow (H) m³/h 108000 108000 108000 108000 108000 108000 108000 108000
Fan
External static pressure Pa 110 110 110 110 110 110 110 110
Refrigerant gas pipe mm 66.7 66.7 66.7 66.7 66.7 66.7 66.7 66.7
Pipe
AV28N
AV28NMVETS
NMV
VETS Refrigerant liquid pipe mm 28.58 28.58 28.58 28.58 28.58 28.58 28.58 28.58
AV30NMVETS
AV
V30NMVETS Sound Sound pressure level (H) dB(A) 70 70 70 70 70 70 70 70
AV32NMVETS
Connectable indoor unit ratio % 50~130 50~130 50~130 50~130 50~130 50~130 50~130 50~130
AV34NMVETS Connection
Ratio
Maximum number of indoor units 64 64 64 64 64 64 64 64
Max.total pipe length m 1000 1000 1000 1000 1000 1000 1000 1000
Max. pipe length(Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U.
110/90 110/90 110/90 110/90 110/90 110/90 110/90 110/90
Max. Pipe Length ( O.U. down/up) *1
1000 110m Auto
Standard drop between I.U.&O.U.
Auto
addressing1
Auto
addressing2
addressing4
Auto
addressing5
Auto
addressing6 ( O.U. up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40 50/40 50/40
Auto
addressing3
MRV 5-T
Total pipe length 1000m, Auto addressing Standard drop between I.U. *4 m 18 18 18 18 18 18 18 18
height drop 110m indoor units
Cooling ˚C -5~53
Working
temp. -25~27
Heating ˚C
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U. *4 Standard design and production in the factory.
EVI compressors Maximum combination 136HP
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
• 049 • ••050
050 •
ion
tallat
053 Features & Benefits Ea
sy
Ins
Su
pe
r Co
005 Features & Benefits
027 MRV 5 Outdoor
y
nc
fficie
hE
Hig
olo
gy 055 Dimensions
n
ch
d Te
ce
van
Ad
• 051 • • 052 •
ADVANCED TECHNOLOGY
High pipe length and height drop
•Max. total pipe length 1000m Max. total pipe length
1000m
•Max. actual pipe length 220m
•Max. equivalent pipe length 260m
•Max. drop between IDU&ODU / 90m (outdoor unit up) / 110m 30m 110m
(outdoor unit down)
•Max. drop between IDU&IDU 30m*
* if the total pipe length is between 300m and 1100m or the drop between IDU
and ODU more than 50m, please contact your local dealer.
Single way total pipe length (=total liquid pipe length) 1000m L1+L2+L3+L4+L5+L6+L7+L8
+L9+L10+L11+L12+L13+L14+L15
Single way max. pipe length (max. length between
outdoor & indoor) actual length 220m L1+ L3+ L5+ L7+ L14+ L13
h1.
gather pipe & first branch pipe) 130m L5
H1.
L1 L3 L5 L10 the farthest indoor
B
Pipe length among outdoor units (length between
C
first gather pipe & farthest outdoor unit) 10m L1+L3
L9
h2.
L11
L7 Height difference between indoors 18m h2
L12 L13
D E
H2
L14 L15 Height difference between outdoors 5m h1
F
MRV 5-C
Easy Installation
Super Comfort Three stage cooling
High Efficiency
chnology
Advanced Te Supercooling cycle
cooling
increases refrigeration
plate heat
exchanger
capacity
Subcooling of heat exchanger
Three stage One stage and Two stage cooling cooling capacity
cooling
ADVANCED TECHNOLOGY
Wide voltage operation
V 415
The new MRV 5-C adopt wide voltage filter board, this can 380 V
MRV 5-C
insure the unit stable working in voltage range between
310V~460V.(note: Outdoor unit)
V
46
0
31
0V
• 053 • • 054 •
ADVANCED TECHNOLOGY HIGH EFFICIENCY
Directly cooling PCB IPLV up to 8.5 (8HP), EER up to 4.82 (8HP)
Traditional refrigerant cooling: firstly copper tube cooling fin, then the fin cooling compressor drive module. Three layers
of heat resistance heat exchange, cause large cold loss. 9.00 8.50 8.48
8.15
cooling efficiency and seasonal energy effciency
Haier directly refrigerant cooling: Refrigerant directly into the fin interior, the fin cooling compressor drive module, reduce 8.00
7.25
7.02
a layer of heat resistance. Under the same operating condition, the temperature of the compressor drive module is lower 7.00
6.90 7.02 6.98
6.72 6.68 6.62
than 8°C, to ensure that the whole unit can continue to work under the high temperature of 53 °C.
6.00
* Integral design, the heat fin and PCB board fit more closely, high cooling efficiency. There will be no condensation,
4.82 EER
more safety 5.00 4.65
4.33
4.21 4.10 IPLV
4.09
4.02 4.00 4.01 3.97
4.00 3.75
Directly cooling PCB
technology: 3.00
Cooling refrigerant in to the
heat exchanger pipe directly,
2.00
then the heat exchanger pipe
cooled the compressor driver 1.00
module. Reduce heat loss,
high cooling effect. 0.00
8 10 12 14 16 18 20 22 24 26 28
Competitive refrigerant heat dissipation Haier direct cooling refrigerant heat dissipation
DC fan motor
Outdoor unit matches efficient variable-speed DC-motor.
HIGH EFFICIENCY drived by sine wave, wider efficiency range and torque range,
motor efficiency is increased by 17%. air fan of outdoor unit
can achieve 0~91Hz stepless frequency.
4 way heat exchanger
SUPER COMFORT
Quick cooling Quick starting of turbo
cooling and heating
Start up and reaching maximum output in short time, Max. output of turbo
realize quick cooling. cooling and heating High frequency working
in 60 minutes
Max. output of normal
DC inverter compressor working
Starting in 5s,
•Adopt double rotor compressor, high efficiency in low frequency, bring better seasonal energy efficiency full frequency working in 70s
*/7&35&3
•The efficient oil separation design of the compressor improves the performance of separating oil and refrigerant.
•The compressor adopts the movement of oil pipe design, increase the oil volume, at the same time also suck the oil at
the bottom when lack of oil. TFD TFD
•The compressor adopts steel crankshaft (originally cast iron crankshaft) to increase the hardness and reliability, reduce
the noise. High temperature performance
Stable performance in high temperature condition, insure the user comfortable experience .
DC fan motor
MRV 5-C
3%
20.00
capacity(Kw)
10.00
35 43 46 53°C
OutdoorTemperature
• 055 • • 056 •
EASY INSTALLATION
Compact electric control box design
Compact electric control box design, compared with MRV 5 heat pump, the electric control box volume reduced by 60%, 3/380~415/50/60
you can maintenance the compressor, stop valve, sensor and other parts only by opening the front panel.
'LPHQVLRQV
AV08NMVQVA AV20NMVQVA
'LPHQVLRQV 'LPHQVLRQV 'LPHQVLRQV
[[ [[ [[ [[ AV10NMVQVA AV22NMVQVA
AV12NMVQVA AV24NMVQVA
AV14NMVQVA AV26NMVQVA
AV16NMVQVA AV28NMVQVA
AV18NMVQVA
reduce
60% Model AV08NMVQVA AV10NMVQVA AV12NMVQVA AV14NMVQVA AV16NMVQVA AV18NMVQVA
/ / / / / /
/ / / / / /
Large connection ratio
Capacity range HP 8 10 12 14 16 18
connection ratio Max power input kW 11.15 11.53 12.09 15.7 18.42 21.86
Single outdoor units 200% Cooling
50%-200% Rated current A 7.85 10.17 13.06 16.04 18.53 20.64
Double outdoor units 150%
Max current A 18.20 18.91 19.74 26.62 30.32 34.26
Electrical
connection ratio= TRIPle outdoor units 130% parameters EER 4.82 4.65 4.33 4.21 4.10 4.09
Total capacity index of the indoor units Note: If the operational capacity of indoor units is more than 130%,low airflow operation is ISEER 8.5 8.75 8.3 7.4 7.02 7.2
capacity index of the outdoor units enforced in all the indoor units.
IPLV 8.50 8.48 8.15 7.25 7.02 6.90
Air flow (H) m3/h 11000 11000 12000 13500 13500 13500
Performance Sound pressure level (H) dB(A) 59.0 59.0 59.0 60.0 61.0 62.0
Smart link 3-way pipe connection Sound power level (H) 73.0 73.0 73.0 74.0 75.0 76.0
dB(A)
Continues Smart link function, easy installation, save You can freely choose the left, front and bottom w
way External dimensions(W/D/H) mm 980/750/1690
labor. connect
ect the pipe, easy installation. Shipping dimensions(W/D/H) mm 1070/850/1858
Refrigerant charge kg 9 9 9 9 10 10
Installation
Refrigerant liquid pipe mm 9.52 / flare 12.7/flare
Refrigerant gas pipe mm 19.05/brazing 22.22 /brazing 25.4/brazing 25.4/brazing 28.58/brazing 28.58/brazing
Max. pipe length( Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U ( O.U
m 110/90 110/90 110/90 110/90 110/90 110/90
down/up) *1
Standard drop between .U.&O.U ( O.U
up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40
MRV 5-C
Standard drop between I.U *4 m 18 18 18 18 18 18
Connection
Connectable indoor unit ratio % 50~200 with limitation
ratio
Maximum number of indoor units 13(20) 16(25) 19(30) 23(36) 26(40) 29(45)
Working
temp. Cooling °C -5~53
• 057 • • 058 •
Model AV20NMVQVA AV22NMVQVA AV24NMVQVA AV26NMVQVA AV28NMVQVA AV30NMVQVA AV32NMVQVA
/ / / / / AV14NMVQVA AV16NMVQVA
/ / / / / AV16NMVQVA AV16NMVQVA
/ / / / / / /
/ / / / / / /
Cooling
HP
kW
20
56.0
22
61.5 67.0
24 26
73.0
28
78.0
30
85.0
32
90.0
Capacity
Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60
Rated power input kW 13.93 15.38 17.87 18.20 19.65 20.5 22.0
Max power input kW 33.01 33.31 33.64 33.92 34.24 34.1 36.8
Cooling
Rated current A 23.52 25.96 30.16 30.73 33.17 34.6 37.1
AV08NMVQVA AV20NMVQVA IPLV 7.02 6.98 6.72 6.68 6.62 7.13 7.00
AV10NMVQVA AV22NMVQVA Air flow (H) 3 17000 18000 19000 19000 19000 13500+13500 13500+13500
m /h
AV12NMVQVA AV24NMVQVA
Performance Sound pressure level (H) dB(A) 63.0 63.0 64.0 64.0 64.0 63.5 64.0
AV14NMVQVA AV26NMVQVA
AV16NMVQVA AV28NMVQVA Sound power level (H) dB(A) 77.0 77.0 78.0 78.0 78.0 77.5 78.0
AV18NMVQVA
External dimensions(W/D/H) mm 1410/750/1690 1410/750/1690 980/750/1690+980/750/1690
Max.total pipe length m 1000 1000 1000 1000 1000 1000 1000
Max. pipe length( Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U ( O.U
m 110/90 110/90 110/90 110/90 110/90 110/90 110/90
down/up) *1
Standard drop between .U.&O.U ( O.U
up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40 50/40
Max.
1000 110m Auto
Auto
addressing2
Auto
addressing3
Auto
addressing5
Auto
addressing6 m 30 30 30 30 30 30 30
MRV 5-C
Total pipe length 1000m, Auto addressing
height drop 110m indoor units
External static pressure Pa 110 110 110 110 110 110 110
Connection
Connectable indoor unit ratio % 50~200 with limitation 50~200 with limitation
ratio
Maximum number of indoor units 33(50) 36(55) 39(60) 43(64) 46(64) 50(64) 53(64)
Working
temp. Cooling °C -5~53 -5~53
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Space saving Better cooling capacity Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;
• 059 • • 060 •
Model AV34NMVQVA AV36NMVQVA AV38NMVQVA AV40NMVQVA AV42NMVQVA AV44NMVQVA
AV16NMVQVA AV18NMVQVA AV18NMVQVA AV20NMVQVA AV20NMVQVA AV22NMVQVA
/ / / / / /
/ / / / / /
Cooling
HP
kW
34
95.0 100.0
36 38
106.0
40
112.0
42
117.5
44
123.0
Capacity
Max. pipe length( Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U ( O.U
m 110/90 110/90 110/90 110/90 110/90 110/90
down/up) *1
Standard drop between .U.&O.U ( O.U
up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40
Max.
1000 110m Auto
Auto
addressing2
Auto
addressing3
Auto
addressing5
Auto
addressing6 m 30 30 30 30 30 30
MRV 5-C
Total pipe length 1000m, Auto addressing
height drop 110m indoor units
External static pressure Pa 110 110 110 110 110 110
Connection
Connectable indoor unit ratio % 50~200 with limitation 50~200 with limitation
ratio
Maximum number of indoor units 56(64) 59(64) 63(64) 64 64 64
Working
temp. Cooling °C -5~53 -5~53
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Space saving Better cooling capacity Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;
• 061 • • 062 •
Model AV46NMVQVA AV48NMVQVA AV50NMVQVA AV52NMVQVA AV54NMVQVA AV56NMVQVA
AV22NMVQVA AV24NMVQVA AV24NMVQVA AV26NMVQVA AV26NMVQVA AV28NMVQVA
/ / / / / /
/ / / / / /
Cooling
HP
kW
46
128.5
48
134.0
50
140.0
52
146.0
54
151.0
56
156.0
Capacity
Max. pipe length( Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U ( O.U
m 110/90 110/90 110/90 110/90 110/90 110/90
down/up) *1
Standard drop between .U.&O.U ( O.U
up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40
Max.
1000 110m Auto
Auto
addressing2
Auto
addressing3
Auto
addressing5
Auto
addressing6 m 30 30 30 30 30 30
MRV
MRV5-C
Total pipe length 1000m, Auto addressing
height drop 110m indoor units
External static pressure Pa 110 110 110 110 110 110
5
Connection
Connectable indoor unit ratio % 50~200 with limitation 50~200 with limitation
ratio
Maximum number of indoor units 64 64 64 64 64 64
Working
temp. Cooling °C -5~53 -5~53
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Space saving Better cooling capacity Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;
• 063 • • 064 •
Model AV58NMVQVA AV60NMVQVA AV62NMVQVA AV64NMVQVA AV66NMVQVA AV68NMVQVA
AV18NMVQVA AV20NMVQVA AV20NMVQVA AV20NMVQVA AV22NMVQVA AV22NMVQVA
/ / / / / /
Cooling
HP
kW
58
162.0
60
168.0
62
173.5
64
179.0
66
184.5
68
190.0
Capacity
Max. pipe length( Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U ( O.U
m 110/90 110/90 110/90 110/90 110/90 110/90
down/up) *1
Standard drop between .U.&O.U ( O.U
up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40
Max.
1000 110m Auto
Auto
addressing2
Auto
addressing3
Auto
addressing5
Auto
addressing6 m 30 30 30 30 30 30
MRV 5-C
Total pipe length 1000m, Auto addressing
height drop 110m indoor units
External static pressure Pa 110 110 110 110 110 110
Connection
Connectable indoor unit ratio % 50~200 with limitation 50~200 with limitation
ratio
Maximum number of indoor units 64 64 64 64 64 64
Working
temp. Cooling °C -5~53 -5~53
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Space saving Better cooling capacity Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;
• 065 • • 066 •
Model AV70NMVQVA AV72NMVQVA AV74NMVQVA AV76NMVQVA AV78NMVQVA AV80NMVQVA
AV22NMVQVA AV24NMVQVA AV24NMVQVA AV24NMVQVA AV26NMVQVA AV26NMVQVA
/ / / / / /
Cooling
HP
kW
70
195.5
72
201.0
74
207.0
76
213.0
78
219.0
80
224.0
Capacity
Max. pipe length( Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U ( O.U
m 110/90 110/90 110/90 110/90 110/90 110/90
down/up) *1
Standard drop between .U.&O.U ( O.U
up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40
Max.
1000 110m Auto
Auto
addressing2
Auto
addressing3
Auto
addressing5
Auto
addressing6 m 30 30 30 30 30 30
MRV 5-C
Total pipe length 1000m, Auto addressing
height drop 110m indoor units
External static pressure Pa 110 110 110 110 110 110
Connection
Connectable indoor unit ratio % 50~200 with limitation 50~200 with limitation
ratio
Maximum number of indoor units 64 64 64 64 64 64
Working
temp. Cooling °C -5~53 -5~53
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Space saving Better cooling capacity Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;
• 067 • • 068 •
Model AV82NMVQVA AV84NMVQVA AV86NMVQVA AV88NMVQVA AV90NMVQVA
AV26NMVQVA AV28NMVQVA AV20NMVQVA AV22NMVQVA AV22NMVQVA
Cooling
HP
kW
82
229.0
84
234.0
86
240.5
88
246.0
90
251.5
Capacity
Auto
addressing2
Auto
addressing3
Auto
addressing5
Auto
addressing6 m 30 30 30 30 30
MRV 5-C
Total pipe length 1000m, Auto addressing
height drop 110m indoor units
External static pressure Pa 110 110 110 110 110
Connection
Connectable indoor unit ratio % 50~200 with limitation 50~200 with limitation
ratio
Maximum number of indoor units 64 64 64 64 64
Working
temp. Cooling °C -5~53 -5~53
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Space saving Better cooling capacity Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;
• 069 • • 070 •
Model AV92NMVQVA AV94NMVQVA AV96NMVQVA AV98NMVQVA AV100NMVQVA
AV22NMVQVA AV22NMVQVA AV24NMVQVA AV24NMVQVA AV24NMVQVA
3/380~415/50/60 Capacity
Capacity range
Cooling
HP
kW
92
257.0
94
262.5
96
268.0
98
274.0
100
280.0
Auto
addressing2
Auto
addressing4
Auto
addressing5
Auto
addressing6
Max drop between I.U *3 m 30 30 30 30 30
Auto
addressing3
MRV 5-C
Total pipe length 1000m, Auto addressing External static pressure Pa 110 110 110 110 110
height drop 110m indoor units
Connection
Connectable indoor unit ratio % 50~200 with limitation 50~200 with limitation
ratio
Maximum number of indoor units 64 64 64 64 64
Working
temp. Cooling °C -5~53 -5~53
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Space saving Better cooling capacity Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;
• 071 • • 072 •
Model AV102NMVQVA AV104NMVQVA AV106NMVQVA AV108NMVQVA AV110NMVQVA AV112NMVQVA
AV24NMVQVA AV26NMVQVA AV26NMVQVA AV26NMVQVA AV26NMVQVA AV28NMVQVA
Cooling
HP
kW
102
286.0
104
292.0
106
297.0
108
302.0
110
307.0
112
312.0
Capacity
Max. pipe length( Equivalent/Actual) m 260/220 260/220 260/220 260/220 260/220 260/220
Max drop between I.U.&O.U ( O.U
m 110/90 110/90 110/90 110/90 110/90 110/90
down/up) *1
Standard drop between .U.&O.U ( O.U
up/down) *2 m 50/40 50/40 50/40 50/40 50/40 50/40
Max.
1000 110m
Max drop between I.U *3
Auto
30 30 30 30 30 30
addressing4
m
Auto
addressing1 Auto
addressing5
Auto
Auto
addressing2
addressing6
Auto
addressing3
MRV 5-C
Total pipe length 1000m, Auto addressing
External static pressure Pa 110 110 110 110 110 110
height drop 110m indoor units
Connection
Connectable indoor unit ratio % 50~200 with limitation 50~200 with limitation
ratio
Maximum number of indoor units 64 64 64 64 64 64
Working
temp. Cooling °C -5~53 -5~53
Max drop between I.U.&O.U *1 If the height difference between the outdoor and the indoor units is from 50 to 110m, you MUST contact your local distributor/dealer for individual design and production.
Standard drop between I.U.&O.U *2 Standard design and production in the factory.
Max drop between I.U. *3 If the height difference between the indoor units is from 18 to 30m, you MUST contact your local distributor/dealer for individual design and production.
Space saving Better cooling capacity Standard drop between I.U. *4 Standard design and production in the factory.
* All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;
• 073 • • 074 •
077 Features & Benefits
082 MRV SII Outdoor
086 Dimensions
ty
liabili
h Re
Hig
n
tio
stalla
y In
Eas
t
m for
Co
per
Su
ncy
fficie
hE
Hig
y
o log
chn
Te
n c ed
Adva
• 075 • • 076 •
ADVANCED TECHNOLOGY
Increasing enthalpy bu replenish gas, realize the unit powerful heating capacity
Taking the heating cycle as an example, when environment
In(P)
tempetature is low, heat exchanged capability of outdoor unit Pc
m+i
MRV S
II Advanced Te
chnology High Efficiency
Super Comfort
Easy Installation
High Reliability
Large diameter fan Double pressure sensor
•Ø570mm big diameter axial flow fan •Equipped with high and low voltage Pressure double sensors
•Zigzag design, reduce airflow disturbance, air •Accurate Pressure control, the system run more smoothly,
volume is bigger, the noise is lower more energy efficiency
ADVANCED TECHNOLOGY
Indoor units and outdoor units self-cleaning
Leadership in technology(4-6HP) Indoor units and outdoor units cleaning mode conversion with nonstop, make abundant use of ODU waste heat to IDU
•Two-stage supercooling cycle technology, increased unit defrosting. At the same time, the IDU uses the waste heat of the ODU to defrost the heat exchanger, to dry the
MRV S II
efficiency by 9%. (Double fan) condensed water, effectively prevent mold breeding.
•Maximizing 30°C undercooling, increase unit refrigerating
capacity by 46%.
• 077 • • 078 •
HIGH EFFICIENCY EASY INSTALLATION
Double side “4 ” handles 2
High energy efficiency 1 Easy to carry
DC inverter compressor Charge Valve “888” test panel
Haier takes DC INV. compressor, 5% power input lower. (14kW) Built-in charge valve enables safer and easier maintenance 2 All running data & error code can be checked from 1
"888" screen, which is easy for installers
DC fan motor and 550mm big fan Low standby power
“Four-way” pipe connection 3
38% power input l ower and 8% airflow higher New PCB programme, reduce 20% standby power consumption
3 4-way (front,back, left & right) pipe connection, easy to
Larger heat exchanger
Heat exchange area rise 10% design and install
Load% Capabiity
Low noise level 100
Peak in the outdoor temperature
Compact side discharge design Good solution
Night Quiet Operation Function for
50 No need additional ventilation hood comparing with top narrow space
Noise can be reduced to 45dB(A).
8hrs 9hrs
discharge unit.
Operation dB(A)
0 ESP
ES
58
Night mode
30Pa
30
4/6HP
Lower 10dB(A) than normal
50
Night mode starts Night mode ends
08:00 12:00 16:00 20:00 00:00 04:00 08:00
Easy installation
Compact Side Discharge Design, Big Capacity, Small Footprint / Small footprint, only 0.42m2, 43% floor area can be reduced.
Easy maintenance for control Maintenance
MRV S II
from the top
0.97 43%
m2 floor area
reduced The control box is in front, reserving space 108mm between
control box and top panel, easy maintenance from the top Difficult to
maintenance
Control box is with hinge design, easy to open for from the front
Hinge design
maintenance(8/10/12HP).
172mm
height
reduced
• 079 • • 080•
HIGH RELIABILITY
Refrigerant automatically reclaim technology
Set refrigerant automatically reclaim through dip switch, the
refrigerant in indoor and pipe can be automatically return to Press these 2
buttons
outdoor, convenient in maintenance and reducing waste of 5 seconds
refrigerant, reduce customer maintenance cost, improve the
efficiency of after-sales maintenance.
AU042FNERA
AU052FNERA
Outdoor
Refrigerant control technology
Without
Refrigerant control technology without high pressure Indoor
accumulator
Air inlet grill design on right side panel Reducing the module Capacity
(1) SEER(T1) / 4.90 4.85
temperature
ηs,c % 193 191
Air inlet grill design, reducing the module temperature and
SCOP(T1) / 3.50 3.55
avoid air dust into air conditioner.
ηs,h % 137 139
•Double pressure sensor with PID control technology. Compressor type / Rotary Rotary
Compressor Motor Power W 4130 4130
•Together with high speed communication to realize the quick start of compressor and more precise control, the
Compressor quantity / 1 1
temperature can be control ±0.5°C.
Fan Air flow (H) m3/h 5400 5400
Temp. PID control
Common control
Pressure Cooling dB(A) 58 60
Too hot
Quick cooling sound level
Heating dB(A) 60 62
Comfortable
MRV S II
Max drop between I.U.&I.U. m 10 10
(1) All the specifications are tested under nominal condition as per Eurovent conditions (In cooling, Indoor temp is 27°C DB/19°C WB; Outdoor temp 35°C DB/24°C WB; In heating, Indoor temp is
20°C DB, Outdoor temp is 7°C DB/6°C WB)
• 081 • • 082 •
Model AU042FPERA AU052FPERA AU062FPERA AU04IFPERA AU05IFPERA AU06IFPERA
Capacity range HP 4 5 6 4 5 6
(1)
SEER(T1) / 6.82 6.92 6.45 6.82 6.63 6.45
Capacity
ηs,c % 269.8 273.8 255 269.8 262.2 255
Compressor quantity / 1 1 1 1 1 1
MRV S II
Double fan series Total pipe length 300m Max drop between IDU & IDU m 15 15 15 15 15 15
Connectable indoor unit ratio % 50-130 50-130 50-130 50-130 50-130 50-130
Connection
ratio Maximum number of indoor
units / 8 10 13 8 10 13
(1) All the specifications are tested under nominal condition as per Eurovent conditions (In cooling, Indoor temp is 27°C DB/19°C WB; Outdoor temp 35°C DB/24°C WB; In heating, Indoor temp is
Two stage sub-cooling Easy connection
20°C DB, Outdoor temp is 7°C DB/6°C WB)
with 4 way
• 083 • • 084 •
Dimensions
AU042FNERA AU052FNERA
950
AU08NFKERA
AU10NFKERA 178 600 172
AU12NFKERA
450
370
970
Model AU08NFKERA AU10NFKERA AU12NFKERA
27
Capacity range HP 8HP 10HP 12HP
Heating(Max) kW 25 32 35
(1) AU042FPERA AU052FPERA AU062FPERA AU04IFPERA AU05IFPERA AU06IFPERA
Capacity SEER(T1) / 8.50 8.20 7.70
Compressor quantity / 1 1 1
3
Fan Air flow (H) m /h 10000 10000 10000
1636
MRV S II
Max drop between I.U.&I.U. m 15 15 15
468
506
Connection Connectable indoor unit ratio % 50~130 50~130 50~130
ratio
Maximum number of indoor units / 13 16 19
• 085 • • 086 •
089 Features & Benefits
092 MRV SI Outdoor
n
stallatio
Easy In
rt
Super Comfo
ncy
High Efficie
gy
ed Technolo
Advanc
• 087 • • 088 •
Full DC inverter twin rotary compressor
Compressor 15~140 RPM wide operating range, can effective
against low load output. The compressor adopts keel motor
technology, the energy efficiency is increased by 10%.
Air inlet grill design on right side panel Reducing the module
temperature Electric
control cabinet
Fan
The unit adopts louver at right side panel for better heat
dissipation to guarantee high frequency operation at high 35°C
temperature. The air inlet grill design, reduces the module 35°C
HIGH EFFICIENCY
DC inverter technology
DC fan motor speed can be adjusted from 0~960r/min, it
can improve the unit efficiency, at the same time, the unit
can realize low ambient cooling operation.
High efficiency
Low vibration, low noise
High reliability
MRV S
I Advanced Te
chnology High Efficiency
Super Comfort
Easy Installation 180° vector control technology
60 120 180
Haier using power resistance to detect the rotor position 240 300 0
ADVANCED TECHNOLOGY
SUPER COMFORT
New update
•We upgraded the whole series and launched new capacity of 3, 5 and 7 HP modules. The overall rounded corner design
refreshes you visually; Operation range 50°CDB
MRV SI
•The stop-valve of new module is build-in, Easier installation; Relying on the compressor upgraded by MRV SI and optimized
27°CWB
•Equipped with super large diameter 550mm fan, in sawtooth shape type design, heat transfer of units more powerful; pipeline upgrade, the operating temperature range of the new
•The heat transfer area of the condensed is increased by 15%, and the heat transfer effect is increased by 10% (5/7HP): model is expanded, including -5°C~50°C for cooling and
The original heat exchanger was 1197*970mm. The current heat exchanger area is 1302*1005mm; -20°C~27°C for heating.
•Standard self-cleaning technology, in addition to the new module upgrade 56°C high temperature cleaning -5°CDB
technology;The heat exchanger of IDU can realize high temperature of 56°, effectively remove mold, and make the air -20°CWB
• 089 • • 090 •
SUPER COMFORT
Precise control
PID control adjusts the output of compressor and the open degree of EEV, balances the indoor refrigerant flow, realizes
the linear output, creates a comfortable environment. The temperature could be controlled precisely.
Constant speed system MRV inverter system
P:Proportion adjustment D:Dif ferential adjustment
I :Integral adjustment MRV III (PID control) Temp
Cooling Conventional control
Refrigerant flow speed
Indoor temperature
Not cool
Comfort enough
Setting
temp
MRV SI
4 8 9
Cooling °C -5°C~50°C -5°C~50°C -5°C~50°C
Working
2 DC fan motor (AU48/60).
2
temp. Heating °C -20°C~27°C -20°C~27°C -20°C~27°C
3 *All the specifications are tested under nominal condition(In cooling, Indoor temp is 27°C DB/19°C WB; Outdoor temp 35°C DB/24°C WB; In heating, Indoor temp is 20°C DB, Outdoor temp is 7°C DB/6°C WB)
3 DC inverter compressor, high efficiency.
4
4 Single set valve, easy to installation and
save installation time.
• 091 • • 092 •
ility
Reliab
High
ation
Install
Easy
ort
rComf
Supe
ncy
Efficie
High
• 093 • • 094 •
SYSTEM INTRODUCTION
What is MRV W series
•MRV W series system is a VRF air conditioning system that adopts water as a cooling or heating source.
•MRV W series can combine water system and refrigerant system together.
Water-cooled MRV
Working principle
Refrigerant system
7
4 (to indoor unit)
5
7
1 6
MRV W
2
3 8
4 5
8
• 095 • • 096 •
SYSTEM INTRODUCTION SYSTEM INTRODUCTION
Type 1 high-rise building Type 3 high-rise building
Conventional chiller system, and water-cooled MRV solution.
Conventional chiller system, and new water-cooled MRV solution.
Chiller MRV W
Shopping mall
Cooling Tower Shopping mall Cooling Tower Cooled/heated water
Cooled/
heated
Chiller Cooling MRV W Cooling water
Atrium
Condensate AHU UHA
Tower Tower water Big duct Big duct
Ground Ground
Exchanger Boiler Basement Exchanger Boiler Basement
Big duct
Office Office
AHU Refrigerant
Suitable buildings
pipe •New construction or retrofit building: MRV W provides an energy efficient solution anywhere that could use a
Cooled Cooled
water-cooled chiller or replacing water source heat pump design by enabling them to afford the water-cooled chiller
Condensate
water
or heated
water water
or heated
benefits. It is especially true for high-rise buildings such as condos, offices, medical centers, schools.
water water •High-rise building that didn’ t design with VRF system.
•Glass curtain wall or special design building.
•No enough space to put the outdoor unit even accept the VRF system.
•Building which required to renewable energy sources.
The
ground Benefit
Boiler Basement Boiler Basement •Lower initial cost for the developer and builder.
•Client or developer can add air conditioning to match load requirement.
Heat exchanger •No rebalancing of water systems if commissioning valves are installed on each floor.
•Connect to the full suite of MRV control solution A/C management system.
•Separate control to every indoor unit.
River water
Cooled/heated water Hotel or
office
Refrigerant
pipe Cooling
Cooling Tower
Lake water
Tower
Cooled/ Cooled/
heated heated
water water
Robby, shopping mall
MRV W
The Sea water
Big duct
ground
Soil Solar energy Waste water Industry waste heat Ground water
• 097 • • 098 •
UNIT STRUCTURE UNIT STRUCTURE
Working principle in cooling mode Core technologies and parts (front side)
Refrigerant pipe
Refrigerant pipe to connect the indoor
35°C units
Gas-liquid separator
Reduce the heat exchanger
30°C
30
0
height(650mm), and the upper and lower
wind speed uniform and high efficiency
Cooling tower Condensing unit
15°C
Heat source
Compact electrical control box
water Compact electric control box, which
20°C
can rote up and down, easy for
compressor service
Heat Water switch
exchanger
Double coil heat Compressor
exchanger
MRV W
Indoor heat exchanger
• 099 • • 100 •
SUPER COMFORT
Low noise level
AHU
60~75dB(A)
Comparing with air system, without fan in the outdoor and with 80
MRV W 70
full insulation design, the noise level can be reduced to only 50dB(A)
60
Screw /oil free chiller
70~90dB(A)
50dB(A), much lower than the air system and conventional chiller. Silent library 50 Street
40
30 Working office
Quiet audio-
visual room
MRV W
•Thanks to the stable water source, the capacity and efficiency
tion High Reliabil
ity will not reduce with extreme ambient conditions compare with
rt Easy Installa
y Super Comfo air-cooled system.
High Efficienc
•Especially in heating mode, water cooling means no defrost
operation is required, the resultant rapid start up time assures
quick and comfortable heating, even in cold environment.
Cooling
7 5.43
4.81
5
4.67
different refrigerant system, more higher total COP. Absorb
the heat
Heating
6
•COP can be up to 6.02, much more higher energy level than air 5
4.8
•Cooling and heating at the same time in different refrigerant Absorb
the heat
Heating
Zone B
system. 4 4.6
system. Boiler
4.35
3
•EER can be up to 4.98, more higher energy level than air system. 2
4.4
4.2
1
EASY INSTALLATION
0 4
which can adjust the condenser volume. •Max water pressure can be up to 1.96MPa.
•Condensate pipe length can be up to 200m.
Max.200m
Two stage deep sub cooling technology
•1st stage sub cooling added a sub cooling coil to condenser
2nd stage sub cooling added a stand alone sub cooler. Flexible Installation Location
•After further cooling, sub-cooling degree can be up to 30˚C, •Max water pressure can be up to 1.96MPa.
with the heat exchanging capacity per unit mass of refrigerant •Condensate pipe length can be up to 200m. Outside Machine room Equipment room
improved by 46% and flow resistance reduced by 55%, and
running efficiency improved by 9%.
High efficiency dc inverter compressor High efficiency double coil heat exchanger Balcony Corridor Storage
High efficiency DC inverter compressor from mitsubishi electric. Double coil heat-exchanger, more uniform heat transfer effect.
Various mode and priority selection
MRV W
The condensers are smaller and can be staked, reducing the installation space and increasing the customers usable
water square footage.
Mode Mode
Refrigerant
Cooling only Heating only Cooling and First on indoor Last on indoor Cooling Heating VIP priority Majority
mode mode heating mode priority priority priority priority
• 101 • • 102 •
EASY INSTALLATION
Long pipe length and high height drop
The condensers are smaller and can be stacked, reducing the installation space. 3/380V-415V/50/60
Cooling tower AV08IMWEWA
Max. 300m AV10IMWEWA
Total pipe length
AV12IMWEWA
Max.200m Max. m
Height drop ID/OD
50
Model AV08IMWEWA AV10IMWEWA AV12IMWEWA
Cooled water pipe
/ / /
Combination model / / /
Max. 150(120)m / / /
Max.1.96MPa
Single pipe length
Capacity range HP 8 10 12
Water
W ter pressure
Wat Capacity Cooling capacity kW 22.4 28 33.5
Heating capacity kW 25 31.5 37.5
Power supply Ph/V/Hz 3/380V-415V/50/60 3/380V-415V/50/60 3/380V-415V/50/60
Cooling Rated power input kW 4.50 6.00 7.70
Boiler Max. power input kW 13.00 15.00 17.00
Rated current A 7.20 9.60 12.32
pump
Sound power level (H) dB(A) 61 62 64
External dimensions(W/D/H) mm 775/545/995 775/545/995 775/545/995
Shipping dimensions(W/D/H) mm 875/655/1182 875/655/1182 875/655/1182
Chilled electric control module Net/Shipping weight kg 172/183 172/183 172/183
•Using refrigerant to reduce the module temperature, to realize Compressor type DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL
stable module temperature, more reliable operation. Compressor quantity 1 INV 1 INV 1 INV
•Canceling heat dissipation fan of the module, reduce the Refrigerant type R410A R410A R410A
power consumption and noise level. Installation Refrigerant charge kg 2 2 2
Refrigerant liquid pipe mm 9.52 9.52 12.7
Refrigerant gas pipe mm 19.05 22.2 25.4
Oil equalization pipe mm 9.52 9.52 9.52
Stable Pressure Setting Pa Total pipe length m 300 300 300
1.7
Stable pressure setting design, to make the high pressure keep Max. pipe length(Equivalent/Actual) m 150/120 150/120 150/120
above the required pressure, ensure the compressor reliability 1.34 Max drop between I.U.&O.U. m 50/40 50/40 50/40
and stable capacity output. 1 Heat Type Double coil Double coil Double coil
0.9 Exchanger Material
Copper&Steel Copper&Steel Copper&Steel
7 20 45
Inlet water connection pipe mm DN32 DN32 DN32
Outlet water connection pipe mm DN32 DN32 DN32
Drain outlet pipe mm / / /
MRV W
45°C
Condensing unit ambient temperature range 0~40°C The condensing unit water flow range is 50~150L/min (Standard 96L/min)
*1 outdoor above 50m, outdoor below 40 m.
*All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
*The specification may change according to the further product development .
• 103 • • 104 •
Model AV16IMWEWA AV18IMWEWA AV20IMWEWA AV22IMWEWA AV24IMWEWA AV26IMWEWA AV28IMWEWA
AV08IMWEWA AV08IMWEWA AV10IMWEWA AV10IMWEWA AV12IMWEWA AV08IMWEWA AV08IMWEWA
Combination model AV08IMWEWA AV10IMWEWA AV10IMWEWA AV12IMWEWA AV12IMWEWA AV08IMWEWA AV10IMWEWA
/ / / / / AV10IMWEWA AV10IMWEWA
Capacity range HP 16 18 20 22 24 26 28
Capacity Cooling capacity kW 44.8 50.4 56 61.5 67.0 72.8 78.4
3/380V-415V/50/60
Heating capacity kW 50.0 56.5 63 69.0 75.0 81.5 88.0
Power supply Ph/V/Hz 3/380V-415V/50/60 3/380V-415V/50/60 3/380V-415V/50/60 3/380V-415V/50/60 3/380V-415V/50/60 3/380V-415V/50/60 3/380V-415V/50/60
Cooling Rated power input kW 9.00 10.50 12.00 13.70 15.40 15.00 16.50
Max. power input kW 26.00 28.00 30.00 32.00 34.00 41.00 43.00
Rated current A 14.39 16.79 19.19 21.91 24.63 23.99 26.39
MRV W
3 Basic Single Module: Most Compact Size Outdoor
8/10/12HP, Max. 3 Design in the Industry Water side pressure drop( inlet and outlet) Kpa 35+35 35+50 50+50 50+70 70+70 35+35+50 35+50+50
Modules Combination up Connection type inner grooved inner grooved inner grooved inner grooved inner grooved inner grooved inner grooved
to 36HP
Max. system water pressure Mpa 1.6 1.6 1.6 1.6 1.6 1.6 1.6
Inlet water temperature range °C 7~45 7~45 7~45 7~45 7~45 7~45 7~45
(Cooling & Heating)
300m
Connection Connectable indoor unit ratio % 50-130 50-130 50-130 50-130 50-130 50-130 50-130
ratio Maximum number of indoor units unit 23 29 33 36 39 43 46
Water cooled VRF, Total 300m Long Pipe Length, *1 outdoor above 50m, outdoor below 40 m.
*All the specifications are tested under nominal condition(in cooling, indoor temp. is 27°C DB/19°C WB;Outdoor temp 35°C DB/24WB;in heating, indoor temp.is 20°C DB,in heating, outdoor temp.is 7°C DB/6°CWB)
higher efficiency Easy for Installation *The specification may change according to the further product development .
• 105 • • 106 •
3/380V-415V/50/60
Dimensions
AV08IMWEWA
AV10IMWEWA
AV12IMWEWA
parameters Heating Rated power input kW 17.40 19.40 21.40 23.40 Ø13 through-hole
630
Max. power input kW 45.00 47.00 49.00 51.00
Rated current A 27.83 31.03 34.23 37.42 340
100
Max.current A 71.97 75.17 78.37 81.57 605
EER /COP
Foundatio n
4.67/5.43 4.54/5.18 4.44/4.98 4.35/4.81
SEER 5.76 5.74 5.72 5.69
SCOP 6.01 5.99 5.97 5.96
Water flow (H) m3/h 3.0-9.0+(3.0-9.0)+(3.0-9.0) 3.0-9.0+(3.0-9.0)+(3.6-10.8) 3.0-9.0+(3.6-10.8)+(3.6-10.8) 3.6-10.8+(3.6-10.8)+(3.6-10.8)
Performance Sound pressure level (H) dB(A) 56 57 57 58
70
Sound power level (H) dB(A) 67 68 68 69
External dimensions(W/D/H) mm (775/545/995)*3 (775/545/995)*3 (775/545/995)*3 (775/545/995)*3
Shipping dimensions(W/D/H) mm (875/655/1182)*3 (875/655/1182)*3 (875/655/1182)*3 (875/655/1182)*3 545
Liquid pipe Oil pipe
443 545
Ga s pipe
Compressor type DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL DC INV. SCROLL 155 Communication terminal
75
Compressor quantity 3 INV 3 INV 3 INV 3 INV
120
Refrigerant type R410A R410A R410A R410A
190 605
Installation Refrigerant charge kg 6 6 6 6
300
Foundatio n
Refrigerant liquid pipe mm 19.05 19.05 19.05 19.05
Refrigerant gas pipe mm 31.8 31.8 31.8 38.1
Oil equalization pipe mm 9.52 9.52 9.52 9.52
Total pipe length m 300 300 300 300
Max. pipe length(Equivalent/Actual) m 150/120 150/120 150/120 150/120
Max drop between I.U.&O.U. m 50/40 50/40 50/40 50/40
Over 500
Heat Type Double coil Double coil Double coil Double coil
Over 100 Over 300
Exchanger Material
Copper&Steel Copper&Steel Copper&Steel Copper&Steel
Inlet water connection pipe mm DN32 DN32 DN32 DN32
Outlet water connection pipe mm DN32 DN32 DN32 DN32
Drain outlet pipe mm / / / / Ø10 Expansion bolt
MRV W
Water side pressure drop( inlet and outlet) Kpa 50+50+50 50+50+70 50+70+70 70+70+70 Concrete
Rubber cushion foundation
Connection type inner grooved inner grooved inner grooved inner grooved
Max. system water pressure Mpa 1.6 1.6 1.6 1.6
Solid ground or roof
Inlet water temperature range
200
(Cooling & Heating) °C 7~45 7~45 7~45 7~45
• 107 • • 108 •
111 Features & Benefits
114 Specification
114 Dimensions
• 109 • • 110 •
SYSTEM INTRODUCTION
Easy MRV system introduction
Haier Easy MRV kit provides a solution to connect Super Match indoor units with MRV outdoor units.
MRV outdoor Connection kit Indoor
1:1
Super Match 36K<Capacity < 60K
1:1
Super Match Capacity ≤ 36K
1:3
MRV Indoor
MRV III-CPLUS
OUTDOOR MRV5 MRV IV MRV SII MRV SI
MRV III(2-Pipe)
HP 8-26 8-24 8 - 16 4 5 4 5 6 8 10 12 3 5 7
3Ph/380-415V/50(60)Hz 3Ph/380-400V/50(60)Hz 3Ph/380-400V/50(60)Hz 1Ph/220-240V/50(60)Hz 3Ph/380-415V/50(60)Hz 3Ph/380-400V/50(60)Hz 1Ph/220-230V/50(60)Hz 3Ph/380-400V/50(60)Hz
Power supply 3Ph/208-230V/50(60)Hz 3Ph/208-230V/60Hz 1Ph/220-240V/50(60)Hz 1Ph/220-230V/50(60)Hz
3Ph/460V/60Hz
Valve Box
MS1-036A(1:1) MS1-060A(1:1) MS3-036A(1:3)
AQUA
AS07QS2HRA AS09QS2HRA AS12QS2HRA
Hi-Wall
Super
Cassette AB12CS2ERA(S) AB18CS2ERA(S) ABH071G2ERG ABH090H1ERG ABH105H1ERG
MRV Outdoor Match
Super Match Indoor
Slim ESP
AD09SS1ERA(N) AD12SS1ERA(N) D18SS1ERA(N) AD24SS1ERA(N)
duct
• 111 • • 112 •
UNIT STRUCTURE SPECIFICATION
Valve box inner structure
Haier easy MRV connection kit consists the following 2 parts.
Different Valve Different Control Parts Power Supply Ph/V/Hz 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60
Size(W/D/H) mm 310/217/155 310/217/155 394/227/253
Shipping dimensions mm 509/285/209 509/285/209 687/295/303
Material / Galvanized steel Galvanized steel Galvanized steel
Color / Grey Grey Grey
Net/shipping weight kg 5/7 5/7 9/12
Liquid pipe mm
High compatible Gas pipe (mm) mm
9.52 (Main) / 6.35
15.88(Main)/ 12.7 / 9.52
9.52 (Main) / 12.7
19.05(Main)/ 15.88
6.35(Main)/9.52 9.52(Main)/12.7
19.05(Main)/ 15.88 15.88(Main)/ 12.7 / 9.52
•Provide a new solution with MRV outdoor and Super Match indoor units to dealers/consumers, more compatible, stock Pipe connection method / Flare connection Flare connection Flare connection
reduced. Brand box-Indoor Max Single pipe length m 15 15 15
•Super match new Hi-wall NF, NH unit and console type can be directly connected with MRV outdoor. Branch box- indoor max drop m 15 15 15
Height Drop between branch box m 15 15 15
MS1-036A MS1-060A
433
378
Easy installation 310 159
152
86
78
15
Gas pipe no need the bend and welding, easy installation
13
43
11
EXV part and control part
36
79
47
14
146
integration, easy for translation
84
155
189
190
216
Traditional
230
and installation. gas pipe is HAIER
integrated into the valve box
165
140
Good performance
integrated system.
394
Largest capacity of side discharge up to 12HP for EASY MRV system.
Largest outdoor capacity Largest capacity of top discharge up to 26HP for Easy MRV system.
78
165
205
Low noise Outside EEV box, low noise.
227
78
135
175
154 203
Good parts FUJIKOKI EEV, good performance and high reliability. 203
217
253
212
• 113 • • 114 •
117 The 2nd Generation AHU Kit
120 Specification
120 Dimensions
ture
struc
Unit
ction
Introdu
System
• 115 • • 116 •
SYSTEM INTRODUCTION
AHU kit configuration
Haier 2nd generation AHU kit also contains the following 4 parts:The Controller model is HW-AA 101DBK, special for
Haier 2nd generation AHU kit as standard accessary, no need to be purchased separately.
AH1-070B/AH1-140B/AH1-280B EXV part Control Part Sensor and wire Controller
System line-up
Haier AHU kit provides a wide range solution for Haier MRV outdoor unit connecting with the 3rd party AHU.
Compatibility
Outdoor MRV5 MRV SII
HP 8-26 4 5 6 8 10 12
Power supply 3Ph/380-415V/50(60)Hz 1Ph/220-230V/50/60HZ 3Ph/380-400V/50/60Hz 3Ph/380-400V/50(60)Hz
AHU &
MRV indoor
AHU need purchase in Market
Control solutions
Four control methods can be used, which can be switched by dip switch based on the site scenario.
Kit
Control method A Control method B
A HU
Unit structure
t i o n
Control temperature via DDC
a
duction
r
System Intro
e
0-10V signal output from DDC
e n
0-10V signal output from DDC
The 2 G
nd
AHU kit receives 0-10V signal to adjust the ODU capacity
AHU kit receives 0-10V signal to adjust set-point temperature
A B
liquid liquid
Gas Gas
C D
Haier offers a range of connection kit to connect MRV outdoor Wired controller
(used in some cases) Standard
Field supply
• 117 • • 118 •
SYSTEM INTRODUCTION SPECIFICATION
Central control Model AH1-070B AH1-140B AH1-280B AH1-560B AH1-730B
•For control method A,B,C of AHU kit, only monitoring the AHU Dimension (W/D/H) (mm) 420/260/165 420/260/165 420/260/165 420/260/215 420/260/215
is available and unable to conduct control operation. +
Communication Sensors
•For control solution D of AHU kit, AHU can be controlled as one Shipping dimensions (mm) 520/340/225 520/340/225 520/340/225 520/340/275 520/340/275
HC-LA1CDBT HA-MA1ADB liquid
MRV indoor unit, both monitoring and control operations are Gas
available. 3rd party AHU (field supply) Material Galvanized steel Galvanized steel Galvanized steel Galvanized steel Galvanized steel
Bms control
Weight (KG) 5.5 5.5 5.5 6.5 6.5
Note:
•Integrate Haier remote monitoring and controlling system via PC
Shipping Weight (KG) 8.5 8.5 8.5 10 10
and BMS interface Wired controller(Necessary)
HCM-01A:Modbus rtu
HCM-03A:Modbus ip/ Bacnet ip
HCM-01A HCM-03A Liquid pipe (mm) 9.52 (Main) / 6.35 9.52 (Main) / 6.35 9.52 (Main) / 6.35 12.7 (Main) / 15.88 12.7 (Main) / 15.88
HCM-05: BACnet ip
AHU Kit-3rd party AHU Max
5 5 5 5 5
Single pipe length (m)
HCM-05
AHU Kit-3rd party AHU Max
5 5 5 5 5
Single pipe length (m)
Note:
Communication Sensors
•Only have BMS interface without Haier remote monitoring system
liquid
HA-MA164AD:Modbus.For MRV 5 and upgraded MRV SII HA-MA164AD Gas AH1-070B AH1-140B AH1-280B
(8/10/12HP) integrates this function 3rd party AHU (field supply)
HCM-04:Bacnet
IGU07:Lonworks 420
UNIT STRUCTURE
110
178
Features
225
•Extend the AHU connected capacity of per kit ranging from 3.5 kW to 73kW, which can meet the small, medium and large
buildings demands.
•Add the 0-10V signal control.
•Supply air temperature (from DDC) or return air temperature controllable.
•Remove the gas pipe, more convenient for installation.
AH1-560B AH1-730B
The 2nd generation AHU kit VS The 1st generation AHU kit
203
156
200
DDC(field supply)
0-10V
225
Communication Sensors
liquid
Gas
• 119 • • 120 •
MRV
INDOOR (Air Guard) 12
123 Air Guard Featuies
23 A
/&8
/&8
/&
Low ESP Slim Duct(0/15/30Pa)
125 L
Duct /
/&&8
/&8
High ESP Duct (20/200Pa)
127 H
• 121 • • 122 •
HEALTHY
Self-cleaning
Make the ODU and IDU cleaning mode conversion without
stopping, make full use of the waste heat of the ODU to Cold expansion Express washing Anti-bacteria
technology technology technology
defrost the IDU with faster speed. Which means when the
ODU fins frost to strip the dirt while IDU will defrost and dry the α
Frost on the evaporator/condenser Hydrophilic aluminum coating with smaller The coating contains silver nanoparticles
generates strong cold expansion force angle helps increase water drainage that kill bacteria and inhibits their growth
easily peels dirt off the surface. efficiency by 20%. with efficiency up to 99%.
EASY INSTALLATION
Multi dimensions
R rd )
I N D O O ( A i r G u a Two series duct you can choice, Slim duct & Medium high ESP duct. The height are 185mm and 248mm, suitable for
M RV
different situations.
HEALTHY
0/15/30 Pa
Multi ESP
Two ESP design you can choice, the ESP of Slim duct is
UVC sterilization 0/15/30 Pa, the ESP of High Medium ESP is 20~200Pa,
The built-in LED UV lights kill airborne hazards when the air suitable for different duct pipe length. 20~200 Pa
• 123 • • 124 •
Low ESP Slim
(0/15/30Pa)
Reserved fresh air inlet Super slim design, Panel External dimensions(W/D/H) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 1210/290.5/32.4 (inlet panel)1210/290.5/32.4 (inlet panel)
only 185mm Shipping dimensions(W/D/H) mm 938/335/220 938/335/220 938/335/220 938/335/220 938/335/220 1258/335/220 1258/335/220
Net/Shipping weight Kg 4/5 4/5 4/5 4/5 4/5 5/6 5/6
Drain pump O-optional,S-standard,W-without S S S S S S S
/ HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
Wired(Optional) / YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
1000mm Controller / YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
Infrared (Optional) / YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
Friendly design of rear or Built-in high head drain pump
bottom air return
• 125 • • 126 •
High ESP
(20/200Pa)
High ESP
(20/200Pa)
HW-BA116ABK YR-E17A HW-BA101ABT YR-E16B YR-HRS01 YL-HRS01
(Cooling only)
Model/Indoor unit AD052MJERA(H) AD072MJERA(H) AD092MJERA(H) AD122MJERA(H) AD162MJERA(H) AD182MJERA(H) AD242MJERA(H) AD282MJERA(H) AD302MJERA(H) AD382MJERA(H) AD482MJERA(H) AD542MJERA(H)
kBtu/h 5.1 7.5 9.6 12.3 15.3 19.1 24.2 27.3 30.7 38.2 47.8 54.6
Cooling
kW 1.5 2.2 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14 16
Capacity
Btu/h 5.8 8.5 10.9 13.7 17 21.5 27.3 30.7 34.1 44.4 55.6 61.4
Heating
kW 1.7 2.5 3.2 4 5 6.3 8 9 10 13 16.3 18
Electrical Ph/V/Hz 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60
Parameters Power supply
Dimensions Net Product m³/h 700/700/248 700/700/248 700/700/248 700/700/248 700/700/248 1100/700/248 1100/700/248 1100/700/248 1100/700/248 1500/700/248 1500/700/248 1500/700/248
(W/D/H)
Shipping Product dB(A) 932/835/280 932/835/280 932/835/280 932/835/280 932/835/280 1332/835/280 1332/835/280 1332/835/280 1332/835/280 1698/857/305 1698/857/305 1698/857/305
Weight Product Net/Shipping dB(A) 27/32 27/32 27/32 27/32 28.5/33.5 36.8/43.4 36.8/43.4 36.8/43.4 39.4/45.4 48.3/56.5 51.3/59.5 51.3/59.5
Static Pressure(Standard/Max) mm 20/200 20/200 20/200 20/200 20/200 20/200 20/200 20/200 20/180 20/180 20/180 20/180
Fan
Air flow (H/M/L) mm 515/440/390 545/470/390 545/470/390 570/495/420 700/625/550 915/765/640 1275/1050/875 1275/1050/875 1450/1200/1000 2000/1700/1400 2150/1750/1400 2350/1950/1600
Sound pressure level(H/M/L) kg 29/27/25 30/28/25 30/28/25 31/29/27 32/30/28 33/31/29 34/31/29 35/33/30 36/33/30 38/35/32 40/36/32 42/38/34
20/200Pa Sound level
Refrigerant liquid pipe mm 6.35 6.35 6.35 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Piping
20/200Pa Only 248mm thick Refrigerant gas pipe Pa 9.52 9.52 9.52 12.7 12.7 12.7 15.88 15.88 15.88 15.88 15.88 15.88
Drain pump O-optional ,S-standard, N-not S S S S S S S S S S S S
/ YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
/ YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
50/60Hz Controller
Wired(Optional)
/ HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK
1000mm
/ HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
Built-in drain pump All module can realize
50/60Hz Infrared(Optional) / YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 127 • • 128 •
MRV
INDOOR
131 Featuies 159 Medium ESP Duct (50/100Pa)
141 1-way Cassette 161 High ESP Duct (20/200Pa)
143 2-Way Cassette 163 High ESP Duct (100/250Pa)
145 MINI 4-Way Cassette 165 Built-in Floor Standing
147 Round way cassette 167 Console
Cassette Convertible Duct Built-in Floor Standing Console High Wall
149 4-Way Cassette 169 High Wall
153 Convertible Type 177 Dimensions
155 Low ESP Slim Duct
• 129 • • 130 •
1-way Cassette 2-way Cassette
New butterfly wing air supply, 5 step fan High ceiling design the air reaches the Thin and light design for easy installation Anti-fouling ceiling design
speed is optional, enjoy healthy air ground Height is only 220mm, reduce the limitations of installation Unique antifouling and antifogging airflow design, no flocking
space. Light weight design to improve installation convenience. guide plate, reduce dirt on the ceiling.
N
N
Celling
Standard condensate water lifting pump Super wide angle air supply comfortable enjoy
Equipped with 700mm drain pump, built-in float switch, conve- Adopt new DC motor, equipped with up and down, left and right
nient according to the actual working situation, Discharge swing wind motor, realize intelligent swing wind control and ultra
condensate water from air conditioner. wide Angle air supply range, enjoy comfortable air.
On both sides The central
of the part part of the
Body NN
Celling
MRV INDOOR
NN
Body
Celling
• 131 • • 132 •
Round way Cassette 4-way Cassete
Free air supply and flexible control to enjoy Streamlined outlook design Square panel the whole product unified more beautiful
a comfortable environment Buy a traditional grille and a dynamic windmill for multi-choice and •Square design, makes room decoration more harmonious, beautiful and easy to arrange lighting
ghtin
ng system.
The outlet adopts stepper motor design to realize the multi-enjoyment. Buy a dynamic windmill to enjoy a dynamic •Thin design of indoor unit, the height is only 260mm (2HP), even in a small space can be installed.
stalle
ed.
four-direction independent control system. mood and relax in the wind.
Stereo air supply, more comfortable.
Invisible LCD Large air inlet grille
MRV INDOOR
Standard condensate lift pump
Standard drain pump, the lift is 700mm and built-in float
Standard drain pump switch, convenient to cooperate with the actual situation to
condensate water discharge air conditioning. 700mm
Body
Standard drain pump, the lift is 700mm and built-in float switch,
convenient to cooperate with the actual situation to condensate
water discharge air conditioning. Celling
Thinner design, easy installation No restriction on hoisting direction Separation of strong and weak
current, high reliability
• 133 • • 134 •
Convertible Type Slim Duct
Thinner body design, good value option Adjusted ESP super slim save installation space agile and convenient
Thin fuselage thickness is only 199mm (2HP), Fuselage thickness of only 180mm, easy to install in the height of
streamlined design, beautiful and generous, narrow residential ceiling, fuselage depth of only 450mm, save
commercial home decoration value choice. the ceiling area, and fully cooperate with the interior decoration. Minimum distance 5mm
NN
NN
Celling
Side view Top view
Standard with filter, easy installation Quiet operation Return air mode selection according to local
With high efficiency filter, fully filter dust, smoke and other fine particles in the air, improve indoor air quality. Filter netease •High efficiency model * High efficiency brushless DC motor, conditions -- more user-friendly installation
disassembly,, easy cleaning, reduce cleaning and maintenan
maintenance operations, so that you enjoy fresh air. speed stepless adjustment, can achieve seven air supply, greatly Provide bottom and rear two return air modes, indoor installation
reduce operating noise. more flexible and convenient, users can choose the best
installation scheme according to the characteristics of interior
•Through the reasonable design of indoor unit thermal
decoration. Note: If there is enough installation space, it is
components and internal air duct, four block wind speed, silent recommended to use the side feed back mode, which can
operation is realized. Note: The standard model of AC motor is effectively reduce the running sound.
also available.
HAPE filter Filer disassembly
MRV INDOOR
5 steps selectable 5 steps selectable
Users can choose ceiling installation, also can choose ground 700mm Return air
Air duct
installation, convenient for users to choose freely.
Return air from the bottom
Floor
• 135 • • 136 •
3D three-dimensional air supply Medium and High ESP DUCT
Static pressure optional, meet different needs
According to users requirements, the static pressure can be
adjusted by wire controller instead of the traditional way of
With makings Sympathetic
fastidious function changing the red and white terminals. The maximum static Indoor unit
pressure of the whole series can reach 200Pa.
Air guide plate, shutter adopts PC+ABS, The panel parameters are displayed in
high temperature resistance, not easy to invisible mode, which makes it softer. The Air duct Air duct
deformation, color and luster lasting. temperature display and color
transformation of refrigeration and heating Air outlet Air inlet
are green and red, which are more classy. Air ducts need to be installed between the indoor unit and the air outlet. When producing long air
supply distance, please choose High static pressure.
narrow shape
Hidden design, more Free setting air outlet High lift-up drain pump
The horizontal louver is driven by
Details of the outstanding using at ease two motors, which makes it easier beautiful humanization setting
The air inlet grille can be dismantled and cleaned to run.
Thin height design, the unit can be easily Due to the use of pipe air supply, Standard condensate water lifting pump,
by pulling the buckle, which is more convenient. Vertical louvers are driven by placed in the ceiling, only the air outlet according to the room environment and standard head 700mm, special models
an electric motor and run exposed, can not feel the existence of user requirements to freely choose the customized range up to 1200mm, and
freely.
indoor unit, so that the indoor space number of air outlet and installation built-in float switch, convenient to
suddenly open. position, fully consider the load of the cooperate with the actual situation of the
3D three-dimensional air supply room and room temperature balance, to site, condensate water discharge air
MRV INDOOR
Fashionable •Pendulum blade two motor control, vertical achieve a more perfect and comfortable conditioning.
and beautiful louver one motor control, easy to operate. feeling.
Streamline design, automatic shutdown, no ash •Free swing wind between 30-80 degrees
accumulation, beautiful atmosphere, hidden up and down, swing wind around 90
installation and home decoration perfect degrees, 3D three-dimensional air supply,
combination, highlight grade. wide Angle of air supply. NN
• 137 • • 138 •
High ESP Duct High Wall
High static pressure design, more room to share Built-in electronic expansion valve for easy installation
The external static pressure can achieve 250Pa, and the air duct can be freely selected. Do an air conditioning, multi-room sharing.
Built-in electronic expansion valve, easy to install. Dc fan motor,
multi-wind speed, with multi-stage air supply angle to create
comfortable airflow. Electronic
Between the skeleton and
variety of wind
expansion
Save energy
Silence design Sliding fan unit Flexible wind control, quick cooling and heating
•Adopt international new sound insulation noise reduction The electrical cabinet In heating and cooling condition, the unit can supply large volume air to quick warm and cold everywhere of indoor room.
materials, pressure off mute wind wheel.
•Prevents indoor pollution and provides maximum wind
speed, ensuring air circulation throughout the room.
•5 speed adjustable wind speed to meet different needs.
When the heating mode is When the cooling mode is
setting, it sends a lot setting, it sends a lot
of warm air down of cold air up
Fan motor
MRV INDOOR
Room form: long and
Room form: U shape
Room form: L shape
narrow shape
• 139 • • 140 •
1-way
1-way
MRV INDOOR
DC fan motor Ultra thin design 185mm
External dimensions(W/D/H) mm 1050/560/122 1050/560/122 1050/560/122 1050/560/122
Panel
Shipping dimensions(W/D/H) mm 1133/623/197 1133/623/197 1133/623/197 1133/623/197
Net/Shipping weight kg 5.3/8.3 5.3/8.3 5.3/8.3 5.3/8.3
/ HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
/ YR-E16B YR-E16B YR-E16B YR-E16B
1000mm Controller Wired(Optional)
/ HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK
/ YR-E17A YR-E17A YR-E17A YR-E17A
Butterfly wings airflow Built-in high head
drain pump maxi. 1000mm Infrared (Optional) / YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 141 • • 142 •
2-way
2-way
HW-BA116ABK YR-E17A HW-BA101ABT YR-E16B YR-HRS01
MRV INDOOR
P2B-1055IB P2B-1055IB P2B-1055IB P2B-1055IB P2B-1055IB
• 143 • • 144 •
Mini 4-way
Mini 4-way
Performance Sound pressure level(H/M/L) dB(A) 32/30/29 32/30/29 32/30/29 33/30/29 33/30/29 34/32/30
Sound power level(H/M/L) dB(A) 46/44/43 46/44/43 46/44/43 47/44/43 47/44/43 48/46/44
External dimensions(W/D/H) mm 570/570/260 570/570/260 570/570/260 570/570/260 570/570/260 570/570/260
Shipping dimensions(W/D/H) mm 718/680/380 718/680/380 718/680/380 718/680/380 718/680/380 718/680/380
620mm Net/Shipping weight kg 16/19 16/19 16/19 19/22 19/22 19/22
Installation
620mm
MRV INDOOR
Refrigerant gas pipe mm 9.52 9.52 9.52 12.7 12.7 12.7
DC fan motor New panel design Model Name PB-620KB PB-620KB PB-620KB PB-620KB PB-620KB PB-620KB
620*620mm
Panel External dimensions(W/D/H) mm 620/620/60 620/620/60 620/620/60 620/620/60 620/620/60 620/620/60
Shipping dimensions(W/D/H) mm 660/660/115 660/660/115 660/660/115 660/660/115 660/660/115 660/660/115
• 145 • • 146 •
Round way
Round way
Model/Indoor unit AB072MRERA AB092MRERA AB122MRERA AB162MRERA AB182MRERA AB242MRERA AB282MRERA AB302MRERA AB382MRERA AB482MRERA AB602MRERA
kBtu/h 7.5 9.5 12.3 15.3 19.1 24.2 27.3 30.7 38.2 47.7 54.6
Cooling
kW 2.2 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14 16
Capacity
Btu/h 8.5 10.9 13.6 17.1 21.5 27.3 30.7 34.1 42.6 54.6 61.2
Heating
kW 2.5 3.2 4 5 6.3 8 9 10 12.5 16 18
Electrical Power supply 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60
Parameters Ph/V/Hz
Air flow (H) m³/h 1000/810/620 1000/810/620 1000/810/620 1000/810/620 1000/810/620 1380/1190/1000 1380/1190/1000 2050/1860/1670 2050/1860/1670 2100/1910/1720 2100/1910/1720
Performance
Sound pressure level(H/M/L) dB(A) 30/27/25 30/27/25 30/27/25 32/29/27 33/30/29 35/34/31 37/35/31 37/35/31 37/35/31 44/40/36 44/40/36
External dimensions(W/D/H) mm 840/840/183 840/840/183 840/840/183 840/840/183 840/840/183 840/840/204 840/840/204 840/840/246 840/840/246 840/840/288 840/840/288
Shipping dimensions(W/D/H) mm 983/983/268 983/983/268 983/983/268 983/983/268 983/983/268 983/983/290 983/983/290 983/983/331 983/983/331 983/983/373 983/983/373
Installation Net/Shipping weight kg 25/28 25/28 25/28 25/28 25/28 27/30 27/30 31/36 31/36 33/38 33/38
Refrigerant liquid pipe mm 6.35 6.35 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Refrigerant gas pipe mm 9.52 9.52 12.7 12.7 12.7 15.88 15.88 15.88 15.88 15.88 15.88
MRV INDOOR
Model name PB-950KB PB-950KB PB-950KB PB-950KB PB-950KB PB-950KB PB-950KB PB-950KB PB-950KB PB-950KB PB-950KB
DC fan motor Unique round-way air External dimensions(W/D/H) mm 950/950/50 950/950/50 950/950/50 950/950/50 950/950/50 950/950/50 950/950/50 950/950/50 950/950/50 950/950/50 950/950/50
outlet, no blind spot Panel
Shipping dimensions(W/D/H) mm 1013/1025/123 1013/1025/123 1013/1025/123 1013/1025/123 1013/1025/123 1013/1025/123 1013/1025/123 1013/1025/123 1013/1025/123 1013/1025/123 1013/1025/123
Net/Shipping weight kg 6.5/9 6.5/9 6.5/9 6.5/9 6.5/9 6.5/9 6.5/9 6.5/9 6.5/9 6.5/9 6.5/9
/ YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
Wired(Optional)
/ YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
Controller Infrared(Optional) / YR-HQS01 YR-HQS01 YR-HQS01 YR-HQS01 YR-HQS01 YR-HQS01 YR-HQS01 YR-HQS01 YR-HQS01 YR-HQS01 YR-HQS01
Innovative 4 independent 6 adjustable louver positions,
air flow control 1296 air flow combinations YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 147 • • 148 •
4-way
4-way
MRV INDOOR
External dimensions(W/D/H) mm 700/700/60 700/700/60 700/700/60 700/700/60 700/700/60 700/700/60
700x700mm panel design Pre-set fresh air inlet
Panel
Shipping dimensions(W/D/H) mm 740/740/115 740/740/115 740/740/115 740/740/115 740/740/115 740/740/115
Net/Shipping weight kg 2.8/4.5 2.8/4.5 2.8/4.5 2.8/4.5 2.8/4.5 2.8/4.5
/ HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
/ YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
Wired(Optional)
1000mm Controller / HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK
/ YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
Built-in high head drain pump Quiet operation
Infrared (Optional) / YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 149 • • 150 •
4-way
4-way
MRV INDOOR
PB-950JB PB-950JB PB-950JB PB-950JB
External dimensions(W/D/H) mm 950/950/60 950/950/60 950/950/60 950/950/60 950/950/60 950/950/60 950/950/60
700x700mm panel design Pre-set fresh air inlet
Panel
Shipping dimensions(W/D/H) mm 992/992/115 992/992/115 992/992/115 992/992/115 992/992/115 992/992/115 992/992/115
Net/Shipping weight kg 6/7.5 6/7.5 6/7.5 6/7.5 6/7.5 6/7.5 6/7.5
/ HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
/ YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
Wired(Optional)
1000mm Controller / HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK
/ YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
Built-in high head drain pump Quiet operation
Infrared (Optional) / YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 151 • • 152 •
HW-BA116ABK YR-E17A HW-BA101ABT YR-E16B YR-HRS01 YL-HRS01
(Cooling only)
Model/Indoor unit AC092MDERA AC122MDERA AC162MDERA AC182MDERA AC242MDERA AC282MDERA AC302MDERA AC382MDERA AC482MDERA
kBtu/h 9.5 12.3 15.4 19.1 24.2 27.3 30.7 38.2 48.0
Cooling
kW 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14.0
Capacity
Btu/h 10.9 13.6 17.1 21.5 27.3 30.7 34.1 42.6 55.0
Heating
kW 3.2 4.0 5 6.3 8 9 10 12.5 16.0
Electrical
Parameters Power supply Ph/V/Hz 1,220~230,50/60 1,220~230,50/60 1,220~230,50/60 1,220~230,50/60 1,220~230,50/60 1,220~230,50/60 1,220~230,50/60 1,220~230,50/60 1,220~230,50/60
Air flow (H) m³/h 820/750/690 820/750/690 950/820/690 950/820/690 1420/1270/1240 1570/1420/1240 1570/1420/1240 2110/1990/1750 2110/1990/1750
Performance Sound pressure level(H/M/L) dB(A) 38/36/34 38/36/34 42/38/35 42/38/35 46/44/41 47/44/41 47/44/41 50/46/43 50/46/43
Sound power level(H/M/L) dB(A) 52/50/47 52/50/47 55/51/48 55/51/48 60/58/54 61/58/54 61/58/55 63/60/57 63/60/57
External dimensions(W/D/H) mm 1000/230/680 1000/230/680 1000/230/680 1000/230/680 1325/230/680 1325/230/680 1325/230/680 1650/230/680 1650/230/680
Shipping dimensions(W/D/H) mm 1100/305/779 1100/305/779 1100/305/779 1100/305/779 1425/305/779 1425/305/779 1425/305/779 1750/305/779 1750/305/779
Installation Net/Shipping weight kg 27.9/33.6 27.9/33.6 27.9/33.6 27.9/33.6 35.8/42.1 35.8/42.1 35.8/42.1 43.5/50.5 43.5/50.5
MRV INDOOR
Refrigerant liquid pipe mm 6.35 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52
DC fan motor Automatic horizontal
and vertical swing Refrigerant gas pipe mm 9.52 12.7 12.7 12.7 15.88 15.88 15.88 15.88 15.88
• 153 • • 154 •
Low ESP Slim
(0/15/30Pa)
Installation Net/Shipping weight kg 16.5/21.5 17.5/22.5 17.5/22.5 17.5/22.5 18.5/23.5 22.2/28.2 24/30
Refrigerant liquid pipe mm 6.35 6.35 6.35 6.35 6.35 6.35 9.52
Refrigerant gas pipe mm 9.52 9.52 9.52 12.7 12.7 12.7 15.88
185mm
Static Pressure(Standard/Max.) Pa 0/15/30 0/15/30 0/15/30 0/15/30 0/15/30 0/15/30 0/15/30
Panel model / P1B-890IA/D P1B-890IA/D P1B-890IA/D P1B-890IA/D P1B-890IA/D P1B-1210IA/D P1B-1210IA/D
MRV INDOOR
External dimensions(W/D/H) mm 890/190/100 (outlet panel) 890/190/100 (outlet panel) 890/190/100 (outlet panel) 890/190/100 (outlet panel) 890/190/100 (outlet panel) 1210/190/100 (outlet panel) 1210/190/100 (outlet panel)
DC fan motor Super slim design,
Panel External dimensions(W/D/H) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 1210/290.5/32.4 (inlet panel) 1210/290.5/32.4 (inlet panel)
only 185mm
Shipping dimensions(W/D/H) mm 938/335/220 938/335/220 938/335/220 938/335/220 938/335/220 1258/335/220 1258/335/220
Net/Shipping weight Kg 4/5 4/5 4/5 4/5 4/5 5/6 5/6
Drain pump O-optional,S-standard,W-without S S S S S S S
/ HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
1000mm Controller Wired(Optional) / YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
/ YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
Friendly design of rear or Built-in high head drain pump
bottom air return Infrared (Optional) / YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 155 • • 156 •
Low ESP Slim
(0/30Pa)
MRV INDOOR
External dimensions(W/D/H) mm 890/190/100 (outlet panel) 890/190/100 (outlet panel) 890/190/100 (outlet panel) 890/190/100 (outlet panel) 890/190/100 (outlet panel) 1210/190/100 (outlet panel) 1210/190/100 (outlet panel)
Reserved fresh air inlet Super slim design, Panel External dimensions(W/D/H) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 890/290.5/32.4 (inlet panel) 1210/290.5/32.4 (inlet panel) 1210/290.5/32.4 (inlet panel)
only 185mm Shipping dimensions(W/D/H) mm 938/335/220 938/335/220 938/335/220 938/335/220 938/335/220 1258/335/220 1258/335/220
Net/Shipping weight Kg 4/5 4/5 4/5 4/5 4/5 5/6 5/6
Drain pump O-optional,S-standard,W-without S S S S S S S
/ HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
/ YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
1000mm Controller Wired(Optional)
/ HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK
/ YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
Friendly design of rear or Built-in high head drain pump
bottom air return Infrared (Optional) / YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 157 • • 158 •
Medium ESP
(50/100Pa)
Medium ESP
(50/100Pa)
HW-BA116ABK YR-E17A HW-BA101ABT YR-E16B YR-HRS01 YL-HRS01
(Cooling only)
*1. HW-BA116ABK, YR-E17A and HW-BA101ABT have built-in infrared signal receiver. YR-E16B no such function
Model/Indoor unit AD052MJERAB AD072MJERAB AD092MJERAB AD122MJERAB AD162MJERAB AD182MJERAB AD242MJERAB AD282MJERAB AD302MJERA AD382MJERA AD482MJERA AD542MJERA
kBtu/h 5.1 7.5 9.5 12.3 15.3 19.1 24.2 27.3 30.7 38.2 47.8 54.6
Cooling
kW 1.5 2.2 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14 16
Capacity
Btu/h 5.8 8.5 10.9 13.6 17.1 21.5 27.3 30.7 34.1 44.4 55.6 61.4
Heating
kW 1.7 2.5 3.2 4 5 6.3 8 9 10 13 16.3 18
Electrical Ph/V/Hz 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60 1/220~230/50/60
Parameters Power supply
Air flow (H) m³/h 630/510/424 630/510/424 630/510/424 630/510/424 740/550/442 980/840/760 1174/1080/960 1174/1080/960 1500/1180/930 1700/1300/900 2000/1700/1250 2000/1700/1250
Performance Sound pressure level(H/M/L) dB(A) 35/33/31 35/33/31 35/33/31 35/33/31 35/33/31 36/34/32 40/37/34 42/38/34 42/38/34 42/39/35 43/40/35 43/40/35
Sound power level(H/M/L) dB(A) 39/37/35 39/37/35 39/37/35 39/37/35 39/37/35 40/38/36 44/41/38 46/42/38 46/42/38 46/33/39 47/44/39 47/44/39
External dimensions(W/D/H) mm 700/700/248 700/700/248 700/700/248 700/700/248 700/700/248 1100/700/248 1100/700/248 1100/700/248 1100/700/248 1500/700/248 1500/700/248 1500/700/248
Shipping dimensions(W/D/H) mm 932/835/280 932/835/280 932/835/280 932/835/280 932/835/280 1332/835/280 1332/835/280 1332/835/280 1332/835/280 1698/857/305 1698/857/305 1698/857/305
Net/Shipping weight kg 27/32 27/32 27/32 27/32 28.5/33.5 36.8/43.5 37/43.4 37/43.6 39.4/45.4 48.3/56.5 51.3/59.5 51.3/59.5
50/100Pa 248mm Installation
Refrigerant liquid pipe mm 6.35 6.35 6.35 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
MRV INDOOR
Refrigerant gas pipe mm 9.52 9.52 9.52 12.7 12.7 12.7 15.88 15.88 15.88 15.88 15.88 15.88
50/100Pa Only 248mm thick Static Pressure(Standard/Max.) Pa 50/100 50/100 50/100 50/100 50/100 50/100 50/100 50/100 50/100 50/100 50/100 50/100
Drain pump O-optional,S-standard,W-without S S S S S S S S S S S S
/ HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
/ YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
50/60Hz Controller
Wired(Optional)
/ YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
1000mm
/ HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK
Built-in drain pump All module can realize
50/60Hz Infrared(Optional) / YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 159 • • 160 •
High ESP
(20/200Pa)
Medium ESP
(20/200Pa)
High ESP
(20/200Pa)
HW-BA116ABK YR-E17A HW-BA101ABT YR-E16B YR-HRS01 YL-HRS01
(Cooling only)
*1. HW-BA116ABK, YR-E17A and HW-BA101ABT have built-in infrared signal receiver. YR-E16B no such function
Model/Indoor unit AD052MJERAD AD072MJERAD AD092MJERAD AD122MJERAD AD162MJERAD AD182MJERAD AD242MJERAD AD282MJERAD AD302MJERAD AD382MJERAD AD482MJERAD AD542MJERAD
HP 0.5 0.8 1.0 1.25 1.7 2.0 2.5 3.0 3.2 4.0 5.0 6.0
kBtu/h 5.1 7.5 9.6 12.3 15.3 19.1 24.2 27.3 30.7 38.2 47.8 54.6
Cooling
kW 1.5 2.2 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14 16
Capacity
kBtu/h 5.8 8.5 10.9 13.7 17 21.5 27.3 30.7 34.1 44.4 55.6 61.4
Heating
kW 1.7 2.5 3.2 4 5 6.3 8 9 10 13 16.3 18
Electrical
Parameters Power supply Ph/V/Hz 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60 1/220-240/50/60
Net Product mm 700/700/248 700/700/248 700/700/248 700/700/248 700/700/248 1100/700/248 1100/700/248 1100/700/248 1100/700/248 1500/700/248 1500/700/248 1500/700/248
Dimensions
Shipping Product mm 932/835/280 932/835/280 932/835/280 932/835/280 932/835/280 1332/835/280 1332/835/280 1332/835/280 1332/835/280 1698/857/305 1698/857/305 1698/857/305
Weight Product Net/Shipping kg 27/32 27/32 27/32 27/32 28.5/33.5 36.8/43.4 36.8/43.4 36.8/43.4 39.4/45.4 48.3/56.5 51.3/59.5 51.3/59.5
Static Pressure(Standard/Max) Pa 20/200 20/200 20/200 20/200 20/200 20/200 20/200 20/200 20/180 20/180 20/180 20/180
Fan
Air flow (H/M/L) m /h3
515/440/390 545/470/390 545/470/390 570/495/420 700/625/550 915/765/640 1275/1050/875 1275/1050/875 1450/1200/1000 2000/1700/1400 2150/1750/1400 2350/1950/1600
Sound pressure level(H/M/L) dB(A) 29/27/25 30/28/25 30/28/25 31/29/27 32/30/28 33/31/29 34/31/29 35/33/30 36/33/30 38/35/32 40/36/32 42/38/34
248mm Sound level
Sound power level(H/M/L) dB(A) 41/39/37 42/40/37 42/40/37 43/41/39 44/42/40 45/43/41 46/43/41 47/45/42 48/45/42 50/47/44 52/48/44 54/50/46
MRV INDOOR
Refrigerant liquid pipe mm 6.35 6.35 6.35 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Piping
DC fan motor Only 248mm thick
Refrigerant gas pipe mm 9.52 9.52 9.52 12.7 12.7 12.7 15.88 15.88 15.88 15.88 15.88 15.88
Drain pump O-optional ,S-standard, N-not / S S S S S S S S S S S S
/ YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A YR-E17A
/ YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B YR-E16B
50/60Hz
YR-E16B
Wired(Optional)
/ HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK
1000mm Controller
HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT HW-BA101ABT
Built-in drain pump All module can realize Infrared(Optional)
50/60Hz
/ YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01 YR(L)-HRS01
• 161 • • 162 •
High ESP
(100/250Pa)
Medium ESP
(20/200Pa)
High ESP
(100/250Pa)
YR-E16B
Model capacity HP 8 10
MRV INDOOR
Air flow (H/M/L) m3/h 4200/3900/2500 5200/4390/3500
DC fan motor Max. ESP 250Pa
Max. capacity 28kw All module can realize Controller Wired(Optional) / YR-E16B YR-E16B
50/60Hz
• 163 • • 164 •
HW-BA116ABK YR-E17A HW-BA101ABT YR-E16B YR-HRS01 YL-HRS01
(Cooling only)
Performance Sound pressure level(H/M/L) dB(A) 38/35/33 38/35/33 40/37/35 40/37/35 42/39/36 42/39/36
Sound power level(H/M/L) dB(A) 51/48/46 51/48/46 53/50/48 53/50/48 55/52/49 55/52/49
MRV INDOOR
Refrigerant gas pipe mm 9.52 9.52 12.7 12.7 12.7 15.88
Require very little installation Good solution for
space: only 220mm installation beneath a window
Static Pressure Pa 0/30 0/30 0/30 0/30 0/30 0/30
• 165 • • 166 •
YR-E17A YR-HRS01 YL-HRS01
(Cooling only)
Electrical Power supply Ph/V/Hz 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60
Parameters
Air flow (H) m³/h 540/460/390/310/270 540/460/390/310/270 540/460/390/310/270 580/500/420/350/270 620/540/460/390/270 620/540/460/390/270
Performance
Sound pressure level(H/M/L) dB(A) 45/42/38/33/30 45/42/38/33/30 45/42/38/33/30 47/44/40/36/30 48/45/42/38/30 48/45/42/38/30
MRV INDOOR
DC fan motor Air discharge through Installation 15.2/18.7 15.2/18.7 15.2/18.7 15.2/18.7 15.2/18.7 15.2/18.7
Net/Shipping weight kg
top ang bottom
• 167 • • 168 •
N High
N High
HW-BA116ABK YR-E17A HW-BA101ABT YR-E16B YR-HRS01 YL-HRS01
(Cooling only)
Air flow (H) m³/h 500/430/370 550/480/420 600/530/470 630/560/500 800/720/650 920/800/720 1010/920/800 1500/1400/1300 1600/1500/1400
Performance Sound pressure level(H/M/L) dB(A) 33/31/29 35/31/29 36/31/29 37/33/29 39/36/34 40/39/35 44/40/36 48/43/40 49/44/41
Sound power level(H/M/L) dB(A) 49/46//41 50/47/42 52/48/44 54/51/50 56/53/51 57/54/52 58/56/54 60/57/53 61/58/54
External dimensions(W/D/H) mm 855/208/280 855/208/280 855/208/280 855/208/280 1115/243/336 1115/243/336 1115/243/336 1316/270/365 1316/270/365
Shipping dimensions(W/D/H) mm 954/279/355 954/279/355 954/279/355 954/279/355 1206/342/418 1206/342/418 1206/342/418 1403/384/463 1403/384/463
Installation Net/Shipping weight kg 9.9/12 9.9/12 9.9/12 9.9/12 15.8/18.9 15.8/18.9 15.8/18.9 21.8/26.3 21.8/26.3
MRV INDOOR
Refrigerant liquid pipe mm 6.35 6.35 6.35 6.35 6.35 6.35 9.52 9.52 9.52
DC fan motor Stylish design & LED display
Refrigerant gas pipe mm 9.52 9.52 9.52 12.7 12.7 12.7 15.88 15.88 15.88
EEV Controller
Wired(Optional)
/ HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK HW-BA116ABK
• 171 • • 172 •
Fresh Air
Fresh Air
250Pa Installation
Net/Shipping weight kg 43.6/50.4 102/116 102/116
MRV INDOOR
Refrigerant liquid pipe mm 9.52 12.7 12.7
Variable static pressure Install with other indoor
100~250Pa setting units together, and Refrigerant gas pipe mm 15.88 22.22 22.22
introduce the outdoor
fresh air into indoor Static Pressure(Standard/Max.) Pa 100 100 100
• 173 • • 174 •
W9301
Performance Sound pressure level (H/M/L) dB(A) 38/35/30 40/38/35 45/42/40 48/46/43 50/48/45
MRV INDOOR
External dimensions(W/D/H) mm 750/530/240 750/530/270 1000/710/270 1200/940/324 1250/935/350
Be controlled with other Efficient heat recovery
indoor units together air processing
Shipping dimensions(W/D/H) mm 955/575/305 955/575/335 1205/755/335 1405/985/389 1455/980/415
Installation
Net weight/Shipping weight kg 26/28 30/32 40/42 55/59 56/60
1000
m³/h Static Pressure Pa 80 80 100 100 100
Heat recovery media Max. air flow 1000m³/h Controller Wired (Standard) / W9301 W9301 W9301 W9301 W9301
element
• 175 • • 176 •
Dimensions
AB052MCERA(M) AB072MCERA(M) AB092MCERA(M)
1-way Cassette AB052MAERA AB072MAERA AB092MAERA AB122MAERA Mini 4-way Cassette AB122MCERA(M) AB162MCERA(M) AB182MCERA(M)
248
pipe connection
298
decoration board620
diagram
Ś
ś
570(indoor units)
535(gap betwwn
590(celing open)
Ŝ
supending rod)
ŝ
165
Ş ş
connect drain pipe
*at least 1500
60
155
⑥
Gap between suspending rod 917 Suspending bolt
4-M8~M10 ⑤
suspending rod420
④
adjustable(0-360)
CeIling open525
Indoor units 505
Gap between
15
Center of the ceiling
750
275
285
210
200
180
25
175
140
1050 Indoor units 875 SN Part name
Ceiling open 1025 SN Part Name 1 Connection port of gas pipe
1 Gas pipe 2 Connection of liquid pipe
176 170
55
30
2 3 Wiring connection port of motor/pumping motor
Liquid pipe
③ 310 210 4 Connect drain pipe
3 Water filling hole
310 1 5 Inlet grill
4 Drain pipe 2 6 Outlet gril
5 Power supply 7 Drain hose(accessory)
6 Communication wire
2-way Cassette AB072MBERA AB092MBERA AB122MBERA AB162MBERA AB182MBERA Round Flow 4-way AB072MRERA AB092MRERA AB122MRERA AB162MRERA AB162MRERA AB242MRERA
Cassette AB282MRERA AB302MRERA AB302MRERA AB482MRERA AB602MRERA
240 240
278 Ś 200 200 297~325
264 130 130 Ş
Drain pipe max. hoisting ş
750
220
280
56
47
161
connection
120
98
95
Š ś Ś
38
600
8
ŝ 840
600mm
ś Ŝ 310 20 20
16-Ø4tapping screw hole
74 460 178 124
A
170
130
126
Suspend ing 270
bolt 4-M10 330 Decoration board 950mm
Ceiling1015
Ŝ ŝ
470
Hanging bolt distance 885
468 417 90 Ceiling hole 890mm
620 Gap between suspending rod 765mm
405
97
MRV INDOOR
Ceiling 640
68
Code Name Code Name
ş Ø7
227
207
2 Liquid pipe
Less than100
2 Pothook
3 Observe plate
3 Fresh air entrance 4 Drain pipe
View A
97
• 177 • • 178 •
Dimensions
4-way Cassette AB052MCERA AB072MCERA AB092MCERA AB122MCERA AB162MCERA AB182MCERA(C) 4-way Cassette AB242MNERA AB282MNERA
(360mm) below
connect freh air inlet accessory
ifting 14in
ΦGLUHFWLQVWDOODWLRQ Ľ ĸ ķ
lifting 23.6in
( 600mm )below
2.4 22.8 2.4
4-M0.1reserved hole
3.5
8 in
6.7 in
5.1 in
5 in
3.5
10.6 in
8.3
6.9
13 in
Ĺ ĺ
18.5 in d ecorated board 38in (950mm)
700mm
less than3.9 indoor units22.4
⑦
700mm
60
(360mm) below
ifting 14in
ifting 14in
Ľ ĸ ķ Ľ ĸ ķ
lifting 23.6in
( 600mm )below
lifting 23.6in
( 600mm )below
7.2 in
9.7 in
6.7 in
6.7 in
5.1 in
5 in
5.1 in
5 in
10.6 in
10.6 in
13 in
Ĺ 13 in d ecorated board 38in (950mm)
ĺ
18.5 in Ĺ ĺ
d ecorated board 38in (950mm)
18.5 in
MRV INDOOR
decorated board 38in (950mm)
gap between studs 31in (765mm) gap between studs 31in (765mm)
• 179 • • 180 •
Dimensions
4-way Cassette AB482MNERA AB602MNERA Convertible AC242MDERA AC282MDERA AC302MDERA
(360mm) below
ifting 14in
Ľ ĸ ķ
lifting 23.6in
( 600mm )below
11.3 in
6.7 in
5.1 in
5 in
10.6 in
13 in
Ĺ ĺ
18.5 in d ecorated board 38in (950mm)
680
1325
decorated board 38in (950mm)
gap between studs 31in (765mm)
230
680
680
1650
1000
230
MRV INDOOR
230
• 181 • • 182 •
Dimensions
Low ESP Slim Duct(0/15/30Pa) AD052MSERA(H) AD072MSERA(H) AD092MSERA(H) AD122MSERA(H) AD162MSERA(H) High ESP Duct(20/200Pa) AD052MJERA(H) AD072MJERA(H) AD092MJERA(H) AD122MJERA(H) AD162MJERA(H)
Low ESP Slim Duct(0/15/30Pa) AD052MSERA(D) AD072MSERA(D) AD092MSERA(D) AD122MSERA(D) AD162MSERA(D) Medium ESP Duct(50/100Pa) AD052MJERAB AD072MJERAB AD092MJERAB AD122MJERAB AD162MJERAB
Low ESP Slim Duct(0/30Pa) AD052MSERA AD072MSERA AD092MSERA AD122MSERA AD162MSERA High ESP Duct(20/200Pa) AD52MJERAD AD72MJERAD AD92MJERAD AD122MJERAD AD162MJERAD
290~325
Top
592
returns from
when air
42 ķ Ĺļ
rear
165
reserved space
248
86
30
160
40
distance between suspending bolt
159
Bottom
420
370
ĸ 184
Ľ
Ľ 578
above 100 238
141
130 130 130 130
52
Ƥ1
6×P100=600( evenly distributed ) 20
Ļ
147
ĺ
892
12
Ĺ
ľ
suspending bolt4-M10 less than 200
619
700
172
152
ķ
B
369
316
2*P260=520 (evenly distributed) ĸ
185
195
90
760
100
ĺ 770
640 45 780
Ľ 90
when air returns from rear Ļ 90 90 90 90 90 90 65 65
120 592
ļ 165
196 700
Lifting bolt
. spacing 761
SN Part Name
2× P260=520 (evenly distributed) 1 Liquid pipe connection No. Name
Gas pipe connection 1 Liquid pipe
172
2
152
2 Gas pipe
3 Drain hose with pump
578 3 Drain pipe
760 4 Drain hose(accessory) 4 Electronic box assy.
770 70
5 sSuspending point 5 Suspension bracket
780
238
Checking hole 6 Air outlet
when air returns from the bottom 6
7 Air return
7 Water drainge outlet Fresh air
8
Low ESP Slim Duct(0/15/30Pa) AD182MSERA(H) AD242MSERA(H) High ESP Duct(20/200Pa) AD182MJERA(H) AD242MJERA(H) AD282MJERA(H) AD302MJERA(H)
Low ESP Slim Duct(0/15/30Pa) AD182MSERA(D) AD242MSERA(D) Medium ESP Duct(50/100Pa) AD182MJERAB AD242MJERAB AD282MJERAB AD302MJERA
Low ESP Slim Duct(0/30Pa) AD182MSERA AD242MSERA High ESP Duct(20/200Pa) AD182MJERAD AD242MJERAD AD282MJERAD AD302MJERAD
0~600 adjustable
290~325
when air returns
Top
42 ķ Ĺļ
45 992
from rear
86
reserved space
165
40
248
159
£¨gap between suspending bolt£©
ĸ 184
Ľ
420
370
Bottom
above 100 Ľ
238 978
116 116 106 106 136 116 116 116 141
52
8×P115=920 (evenly distributed) Ļ Ƥ1
ĺ 20
1213
147
12
suspending bolt4-M10 less than 200 Ĺ
172
153
B
ľ
619
700
ķ
185
90
369
ĺ 1080 316
ĸ
195
960 45 1090
100
1100
MRV INDOOR
90
Ļ 116 116 116 116 116 116 116 112
120 992 165
ļ 1100
196
Ľ SN Part Name Lifting bolt
. spacing 1161
1 liquid pipe connection
No. Name
152
172
238
1090 4 Electronic box assy.
1100 5 suspending point 5 Suspension bracket
when air returns from the bottom 6 Air outlet
6 checking hole
7 Air return
7 water drainge outlet 8 Fresh air
• 183 • • 184 •
Dimensions
High ESP Duct(20/200Pa) AD382MJERA(H) AD482MJERA(H) AD542MJERA(H) AE072MLERA AE092MLERA AE122MLERA AE162MLERA AE182MLERA AE242MLERA
Medium ESP Duct(50/100Pa) AD382MJERA AD482MJERA AD542MJERA
Built-in Floor Standing
High ESP Duct(20/200Pa) AD382MJERAD AD482MJERAD AD542MJERAD
205
52 141
④
Ƥ1
12
147
③ 20
603 624
580
⑧
700
620
①
369
316
② 990
195
100
90
120 ⑤
1500
196 ⑥
1561 1042
No. Name
1 Liquid pipe
2 Gas pipe
1378
3 Drain pipe
144
4 Electrical box
5 Hanging foot
238
6 Air outlet
7 Air return
8 Fresh air
Top
44(1116) 700 210
13 3/4(348)
Bottom
150
48 1/8(1221) ķ
600
145
492
ĸ
Ĺ
ļ
2(51)
33 1/4(845)
35 1/4(895)
252
228
1 1/2(38)
MRV INDOOR
1 1/4(32)
12 3/4(324)
52 3/8(1330)
8 3/8(213) Liquid pipe
Ļ
52 5/8(1366) Φ6.35(flared) 1 4"
Air Return Gas pipe
No. Name
1 Control borad cover Φ12.7(flared) 1 2"
160
2 Liquid pipe connection
3 Gas pipe connection
14 3/4(376)
4 Top baffle
5 Gravity drain hose
6 Bottom baffle
634
37 3/4(960)
• 185 • • 186 •
Dimensions
N High Wall AS052MNERAB AS072MNERAB AS092MNERAB AS122MNERAB N High Wall AS282MNERA AS302MNERA
AS052MFERAB AS072MFERAB AS092MFERAB AS122MFERAB
855
620
1316
220 Snap joint
200 1065
340
280
19
34
20
Gas pipe
855 Drain pipe
110 Liquid pipe
56
46
138 125
30
345 Liquid pipe
130
37
511 DrainSLSH
552 135 GasSLSH
652 652
692
1182
1(L) 2(N) 3 4
124
1(L) 2(N) 3 4
148
175
88 216 96
165
248
1115
878
243 274
52 141
④
336 Ƥ1
12
147
③ 20
24
Gas pipe
23
Drain pipe ⑧
700
620
102 ①
369
123
316
587
②
195
612
100
903
90
120 ⑤
MRV INDOOR
1500
196 ⑥
1561
No. Name
1(L) 2(N) 3 4
1 Liquid pipe
135
2 Gas pipe
1378
3 Drain pipe
196 96 4 Electrical box
5 Hanging foot
238
6 Air outlet
7 Air return
8 Fresh air
• 187 • • 188 •
Dimensions
Fresh Air Duct AD722MTERF AD962MTERF
876
23 830 255
air inlet 245 80 23 air outlet
75
50
B A
1510
38 90
1570
110
1725
304 view A
150
205
1622
1572 More than 830
1510 800 95
85
360 255
view C
MRV INDOOR
Model A B H
ERV0150ANW 530 750 240
ERV0260ANW 530 750 270
ERV0500ANW 690 1000 256
ERV0800ANW 920 1200 324
ERV01000ANW 915 1250 350
• 189 • • 190 •
CONTROL
SYSTEM
193 Individual Controller 205 Multi Tenant Solution
195 Centralized Controller 206 Service Tool
Individual Centralized BMS Multi Tenant Service Tool Controllers Match Table Accessories
Controller Controller Solution for MRV Indoor Units
199 BMS Solution
• 191 • • 192 •
INDIVIDUAL CONTROLLER
YR-E17A
•On/Off, Mode, Fan speed, Temperature setting, Swing
•Individual & Group control (Max.16 indoor units)
•Simple and Smart design, 86*86*13.05mm
•Touch button with back light
•Timer/ Clock
•Individual flap control for round way cassette and compact cassette
•Built-in infrared signal receiver for duct units
•Self-cleaning function
•Built-in humidity sensor and humidity display
HW-BA116ABK
•Alternating current
•Basic fucntion: on/off, mode, fan speed, temperature
•Individual & group control (max.16 indoor units)
•Simple and smart design, 86*86*14.80mm
•Could receive wireless controller signal
HW-BA101ABT
•Individual & group control (max. 16 indoor units controllable)
•Compact design 86*86mm
•Touch screen
•Black and tempered glass body with highlight LED icon display
•Basic function: on/off, mode, swing, dry, auto
•Built-in infrared signal receiver for infrared remote control
rol of your air
intelligent cont
troller you easy and
Individual Con rs which enable
ro lle •Built-in buzzer
les s co nt
red and wire ning managem
ent.
s a variety of wi
e ind ivi du al co ntrol system ha be st su its fo r your air conditio
Th
conditioners. Yo
u can choose th
e one which YR-E16B
•Colorful screen
•On/off, mode, fan speed, temperature setting, swing
•Individual & group control (max 16 indoor units)
•Fahrenheit/ celsius selectable; sensitivity ±0.5°c (±1°F)
•Weekly timer
INDIVIDUAL CONTROLLER •Individual louver control for MINI 4-way cassette and Round Flow 4-way cassette
•Static pressure setting
YR-HQS01 / &8
/&8
/& 8
•On/Off, Operation Mode, Fan speed, Temperature setting, Swing
•Turbo and Quiet
RE-02
•Infrared signal receiver
•Individual louver control for Round Flow 4- way cassette and mini 4-way cassette
•Clock & Timer •Realize the remote control of duct type indoor unit
•Health function •Model selection depens on the duct indoor unit
•Self-Clean
•Backlight
•Convenient to operate most functions through one button
CONTROL SYSTEM
YR-HRS01 /
/&&8
/&88
Central Control WIFI Module (HI-WA164DBI)
•On/Off, Operation Mode, Fan speed, Temperature setting, Swing •Individual/Central remote control by APP
•Turbo and quiet •Max.64 IDUs controllable for single wifi module (Max. 256 for combinations)
•Individual louver control for Round Flow 4- way cassette and mini 4-way cassette •Remote monitoring and control: on/off, temp, operation mode, fan speeds
•Self-Clean •Weekly Scheduling
•Timer •Error alarm and error history
•Health function •Convenient management authority sharing without repeating to pair with units
•Backlight •Connecting to 5-inch central controller (HC-SA164DBT);
(MRV5 and HA-MA164AD gateway can connect directly.)
• 193 • • 194 •
CENTRALIZED CONTROLLER
Monitoring up to 64 Set schedule for unit,
indoor unit could group,all time control
control HRV and could be add,change,
monitoring the delete,unit control,
state of all IDU display IIDU
DU
Un um
u mber,
mbe
ber,
be r,ON
ON/O
N/OFF
OF ,
number,ON/OFF, group control , all
Fault IDU number ON/OFF
Interface display
Setting password
mode choice: list or
according to user
icon All on, all off,
demand
control all, control
dually or by
nditioner indivi
o n t ro ll e r aging your air co
select
Centralized C
nc e wh ile m an
nvenient experie ent.
u a smart and co
offers yo ning managem conditio
control system perfect your air
The centralized of co nt ro lle rs can be used to
nes. a variety
groups or by zo
HC-SA164DBT System
HC-SA164DBT MRV
•Individual control, central control (max. 64 indoor units)
•5-inch TFT LCD touch screen with back light
•Weekly timer
•Indoor units' information editable
•Historical error HA-MA164AD
•MRV 5 system and upgraded MRV SII(8/10/12HP) outdoor units
can connect directly
HC-SA164DBT
CONTROL SYSTEM
•Other MRV system requires HA-MA164AD
YCJ-A002
SuperMatch
• 195 • • 196 •
CENTRALIZED CONTROLLER CENTRALIZED CONTROLLER
YCZ-A004 HC-LA1CDBT
•Individual control, group control & central control (Max. 256 indoor •12.5-inch TFT LCD touch screen
units) •Max. 800 MRV indoor units and Max. 128 LCAC IDUs connectable
•7-inch TFT LCD touch screen with back light for one controller totally 928 IDUS connectable
•Floor plan layout view
•Weekly timer
•Web Access and Email Alarm
•Indoor units' information editable •Weekly Schedule and Special day setting
•Error display •Integrate 3rd party devices like fire alarm, lighting with Haier indoor units
•Other MRV system requires HA-MA164AD •All MRV system requires the new gateway HA-MA1ADB(one
system requires one gateway)
•LCAC products requires PCB adapter YCJ-A002(One 2(One IDU requires
one YCJ-A002)
•Total electricity consumption display
•Data curve /
/&8
/& &88
•Electricity consumption distribution for Tenant billing
•Multi Language
HA-MA1ADB
Max32
Internet/intranet (RS485) Home-bus
HA-MA164AD
(RS485) Home-bus
2fire 2DI
DI 2DO
Max32
(RS485) Home-bus
MRV
RS485(COM2)
HA-MA1ADB
YCJ-A002
Home-bus
HA-MA164AD
Max128
YCJ-A002
RS485(COM3) Home-bus
YCZ-A004
YCJ-A002
Home-bus
YCJ-A002
SuperMatch
CONTROL SYSTEM
Modbus ETUgateway
Max16 DO points
Max32
RS485(COM4)
Max512 units
YCJ-A002 Max16 DO points
Modbus ETUgateway
• 197 • • 198 •
BMS MONITOR
HCM-01A
•Local control version; convert USB to RS-485
•Max. 400 indoor units can be controlled
•Modbus rtu interface
•Brand new interface design
•Win 7 32bits/64bits, Win 8 Pro, Win 10 Pro
•Max.32 systems connectable
•MRV 5system and upgraded MRV SII(8/10/12HP) outdoor units can directly
connect with HCM-01A
•Other MRV system outdoor units require HA-MA164AD
•Electricity charge report (must use IGU02)
HCM-01A System
Home BUS
HA-MA164AD
nt
iding an excelle
ing management system, prov
BMS Solution odules could perfectly integrate air conditioners
into the build
anagement m
The building m
USB
Ammeter
IGU02
Max. 32 gateways
CONTROL SYSTEM
monitoring and controlling the AC systems, 3rd party BMS or BAS
RS-485
interface and electricity distribution management i.g the tenant billing. Ammeter
HCM-01A IGU02
*Each outdoor system requires one HA-MA164AD; For power consumption function, users should connect IGU02 and Ammeter.
• 199 • • 200 •
BMS MONITOR BMS MONITOR
HCM-03A HCM-05 Hardware
Upgrade
•Remote monitoring version; third party interface: BACnet ip/ Modbus ip •Remote monitoring version
•Max. 1500 indoor units can be controlled •Third party interface: BACnet ip
•Max. 4 groups. each group can connect 20 systems •Max. 250 indoor units can be controlled for HCM-05; and 500 indoor units for HCM-05A
•MRV 5 system and upgraded MRV SII(8/10/12HP) outdoor units can directly •Max. 32 systems for HCM-05. Each system requires one IGU02/HA-MA164AD
connect with HCM-03A •Max. 64 systems for HCM-05A. Each system requires one IGU02/HA-MA164AD
•Other MRV system outdoor units require HA-MA164AD •Operation status setting & monitoring.
•Operation status setting & monitoring. •Schedule setting
•Schedule setting •Multi user management with different authorized levels
•Multi user management with different authorized levels •Electricity charge report (must use IGU02)
•Operation and error history log •Operation and error history log
•Electricity charge report (must use IGU02) •Cooperated technology with honeywell
HA-MA164AD
Homebus
HA-MA164AD
Max. 32 HA-MA1
CONTROL SYSTEM
HA-MA164AD
TCP/IP
HCM-05 PC
C
• 201 • • 202 •
BMS INTERFACE
HA-MA164AD
•Protocol adapter, convert homebus to RS-485
•Gateway: modbus rtu
•Max. 64 indoor units can be connected with one HA-MA164AD
•MRV 5system and upgraded MRV SII(8/10/12HP) outdoor units can directly connect with central
controller HC-SA164AD and YCZ-A004 or BMS monitor: HCM-01A and HCM-03A
•Other MRV system outdoor units require HA-MA164AD
HA-MA1ADB
•Interface: Modbus
•Match with 12.5-inch webserver central controller HC-LA1CDBT
•Max. 128 indoor units connectable
•Digital tube display Indoor quantity, gateway address, time and date
•Electricity data collection, calculation, distribution and storage
IGU02
•Protocol adapter, convert homebus to modbus
•Electricity data collection, calculation, allocation and storage
•Match with BMS (HCM-01A,03A,05,05A). each system requires one IGU02
•Max.40 indoor units can be connected with one IGU02
IGU07
•Protocol adapter, convert modbus rtu to lonworks
•Each system requires one IGU07+ HA-MA164AD
•Max. 32 indoor units can be connected in one system
•External 24V DC power supply is needed
LonWorks System
Homebus
for large
anagement system; perfect
rious building m
BMS interfacesy and convenient way to integrate air conditione
rs into va
er you an ea
The adapters off Third party HA-MA164AD Max. 32 indoor units
l pr oje cts. IGU07
commercia RS-485, Max. 1000m
Homebus
CONTROL SYSTEM
BAS system, including the Modbus interface, BACnet interface and
Lonworks interface etc. Third party IGU07
HA-MA164AD
Homebus
• 203 • • 204 •
BMS INTERFACE SERVICE TOOL
HCM-04 Address setting and checking tool YR-NS
•BACnet gateway, convert modbus rtu to BACnet ip •On/Off, Mode, Fan speed, Temperature setting, Swing
•Max.128 indoor units/ 4 systems can be controlled. Max. 32 indoor units for one system •IDU address checking
•MRV 5 and upgraded MRV SI I (8/10/12HP) can connect directly with HCM-04. •IDU address setting
•Other MRV systems require IGU02 or HA-MA164AD
•BTL certificate
Hard work to check the indoor unit address Easy to get the indoor unit addresss
Time Consuming Time saving
Before Now
MTC-001
Application Scenario: Haier HACS Selection Software -easy to Design and Customization
•a. The multi tenant site using separate circuit breaker for each indoor unit Haier HACS Selection Software supports PC & App, which means the reports and information on the phone and computer are
•b. The hotel room using key-tag system which cuts off the power of indoor unit directly synchronous.
•When it is detected that any connected indoor unit is forcibly cut off, the MTC-001 provides DC With the Haier MRV Selection software, engineers and consultants can easily design, layout and prepare a full MRV system for
power to the indoor PCB to ensure that the indoor unit maintains standby mode: the EEV is turned quotation in a few steps. It selects the right models to meet your building load requirements and calculates the piping schematic
off and the control signal is blocked to prevent the system from alarming automatically or manually, as well as the wiring. It’ s possible to import dwg or jpg drawings. The selection software guides you within
•Note: If there is power or communication failure in the indoor computer board, MTC-001 cannot design rules and offers a comprehensive system design report under pdf, word or excel format.
be prevented and detected
Launch page System Layout Page System Configuration page Synchronous Information on PC & APP
OFF
ELCB ELCB ELCB ELCB ELCB ELCB
AC380V AC220V AC220V AC220V AC220V AC220V
CONTROL SYSTEM
MTC-001 MTC-001 MTC-001 MTC-001
DC 12/5V
Comm
• 205 • • 206 •
CONTROLLERS MATCH TABLE FOR MRV INDOOR UNITS ACCESSORIES
Refrigerant gathering
4-way Gather pipe HZG-R20B 2 outdoor units
for MRV 5-RC
Cassette
Refrigerant gathering
Convertible Gather pipe HZG-R30B for MRV 5-RC
3 outdoor units
Convertible
Gather pipe HZG-R40B
Refrigerant gathering
4 outdoor units
for MRV 5-RC
Low ESP Slim Duct
(0/15/30Pa)
Refrigerant distribution Total indoor units capacity less than
Manifold pipe FQG-B335A
Low ESP Slim Duct for heat pump MRV 33,500W
(0/30Pa) Refrigerant distribution Total indoor units capacity less than
Manifold pipe FQG-B506A 50,600W, but equal or bigger than
for heat pump MRV 33,500W
Medium ESP Duct Refrigerant distribution Total indoor units capacity less than
(50/96 Pa) Manifold pipe FQG-B730A for heat pump MRV 73,000W, but equal or bigger than
50,600W
Refrigerant distribution Total indoor units capacity
Medium ESP Duct Manifold pipe FQG-B1350A for heat pump MRV less than 135,000W, but equal or
AD**2MJERA bigger than 73,000W
(50/100 Pa)
Refrigerant distribution Total indoor units capacity less than
Manifold pipe FQG-R335A for heat recovery MRV 33,500W
Medium ESP Duct Refrigerant distribution Total indoor units capacity less than
FQG-R506A 50,600W, but equal or bigger than
(80/120 Pa) Manifold pipe for heat recovery MRV
33,500W
Refrigerant distribution Total indoor units capacity less than
High ESP Duct Manifold pipe FQG-R730A for heat recovery MRV 73,000W, but equal or bigger than
(100/196 Pa) 50,600W
Refrigerant distribution Total indoor units capacity less than
Manifold pipe FQG-R1350A for heat recovery MRV 135,000W, but equal or bigger than
73,000W
High ESP Duct Total indoor capacity less than
Refrigerant distribution
(0-200Pa) Manifold pipe FQG-B2040A 204,000W but equal or bigger than
for heat pump
135,000W
High Wall
(N platform) VP1-112A, VP1-180A
VP box Vavle pipe box MRV III-RC(heat recovery)
VP1-280A
CONTROL SYSTEM
Console AF**2MBERA
VP box VP4-450A Vavle pipe box MRV III-RC(heat recovery)
Built-in Floor
Standing VP1-112B, VP1-180B
VP box VP1-280B
Vavle pipe box MRV 5-RC(heat recovery)
• 207 • • 208 •
REFERENCE
PROJECTS
Subway
Industriall Hotel
Offices
Hospital
Education
Home &
Apartment
Shop &
Showroom
• 209 • • 210 •
Reference Projects
Country: Algeria Country: Algeria
Project Name: Mobil Art Project Name: Hotel-Akbou Bedjaia
Installation Series: MRV-S&MRVIII Installation Series: MRVII-C&MRVIII-C
REFERENCE PROJECTS
• 211 • • 212 •
Reference Projects
Country: Algeria Country: Algeria
Project Name: Ofarco Office Project Name: Tapis office and showroom
Installation Series: MRVII-S Installation Series: MRVII-C
REFERENCE PROJECTS
• 213 • • 214 •
Reference Projects
Country: Czech Republic Country: Czech Republic
Project Name: Outlet Arena Moravia Project Name: Pragolaktos
Installation Series: MRV-S + MRV5 Installation Series: MRV-S + MRV5
REFERENCE PROJECTS
• 215 • • 216 •
Reference Projects
Country: Czech Republic Country: France
Project Name: DEK Stavebniny Project Name: Les Roches Rouges hotel
Installation Series:MRV-S Installation Series:MRV IV
REFERENCE PROJECTS
• 217 • • 218 •
Reference Projects
Country: Italy Country: Italy
Project Name: Pantheon Hotel Project Name: Marina Hotel
Installation Series:MRV III-RC Installation Series: MRV IV
REFERENCE PROJECTS
• 219 • • 220 •
Reference Projects
Country: Italy Country: Indonesia
Project Name: Meininger Hotel Project Name: Kosambi Apartement
Installation Series: MRV III C Plus +MRV III –RC Installation Series: MRV IV-C & SINGLE
REFERENCE PROJECTS
• 221
193 • 222 •
• 194
Reference Projects
Country: Malta Country: Pakistan
Project Name: St. Vincent de Paul Residence Project Name: Lecole School
Installation Series: MRV IV + MRV S Installation Series: MRV IV
REFERENCE PROJECTS
• 223 • • 224 •
Reference Projects
Country: Pakistan Country: Pakistan
Project Name: CNS Project Name: Nagina Head Office’s HVAC project
Installation Series: MRV-3C PLUS Installation Series: MRV 5
REFERENCE PROJECTS
• 225 • • 226 •
Reference Projects
Country: Poland Country: Poland
Project Name: 46 luxury apartments Project Name: 4 separate building designated for buisness, retail and ententainment purposes
Installation Series: 3 MRV IV-C systems, 1 MRV III-S system Installation Series: MRV III-C
REFERENCE PROJECTS
• 227 • • 228 •
Reference Projects
Country: Poland Country: Russia
Project Name: 2000sq m, 3 story building Project Name: Azimut
Installation Series: MRV III-C Installation Series: MRV III – C; MRV –S
REFERENCE PROJECTS
• 229 • • 230 •
Reference Projects
Country: Spain Country: Thailand
Project Name: Escuela de Hosteleria de Jerez Project Name: The South Cuisine
Installation Series: MRV III Plus Installation Series: MRV III c-Plus
REFERENCE PROJECTS
• 231 • • 232 •
Reference Projects
Country: Turkey Country: Thailand
Project Name: Caspian Shopping Center Project Name:Wandee Culinary Cook School
Installation Series: MRV 5 Installation Series: MRV III-C PLUS
REFERENCE PROJECTS