292 - JK Paper - Technical Offer - Rev 00
292 - JK Paper - Technical Offer - Rev 00
292 - JK Paper - Technical Offer - Rev 00
Date. 27/12/2021
REVD.
Revision Summary
liens and encumbrances when shipped to Buyer and will be free from defects in material and workmanship, will
conform to Seller's specifications or to Buyer's specifications where agreed to in writing for a period of 12
months from initial operation or 18 months from the date of shipment to Buyer, whichever occurs first, provided
that:
a. Seller is promptly notified (within the warranty period) of any warranty claim; and
b. The goods and merchandise are returned to Seller, freight prepaid, after Buyer has received a return
authorization number from Seller. Seller will credit Buyer for reasonable freight charges paid to return such
goods and merchandise; and
c. Seller's examination of such items shall disclose to its reasonable satisfaction that the claimed defect in the
goods and merchandise was not caused by misuse, static discharge, abuse, neglect, improper handling,
REVISIONS
installation, unauthorized repair, alteration or accident. Modification of goods and merchandise by Buyer, or at
Buyer's direction, unless specifically authorized in writing by Seller, shall invalidate the above warranty.
Seller's liability under this warranty is limited to repairing, replacing or issuing a credit in the amount of the unit
contract price, at its election, for any such claim. Any repair or replacement shall not extend the warranty period.
SYM.
5 Impact 2.5 G
6 Dirt None
<Notes>
If the operation condition exceeds above environmental conditions, VFD may trip.
Please note that ambient temperature greatly influences the longevity of the VFD.
3 Auxiliary power source for pre-charge and cooling fans 415 V, 50 Hz, 3 phase
2 Quantity 2
6 Pole 4
9 Rated current 35 A
5 Rated Current 53 A
6 Output voltage 6600 V
7 Type Multi-level IGBT drive
8 Cooling method Air cooling
9 Input harmonic filter Not Required
10 Output filter Not Required
REVISIONS
2 Inverter ready to run Normally Open, Dry type contact AC220, DC24V
Close at Inverter ready
to run
SYM.
4 Inverter fault/ trip Normally Open, Dry type contact AC220, DC24V
Open at Inverter fault/
trip
Open/Close interlock
DATE
50/51
HIVECTOL-HVI-E2-66-600
SYM.
Motor IM
330 kW, 6.6 kV
Note: External wiring / interconnection wiring between VFD and Isolator shall be
in customer scope.
mm
CHKD.
REVD.
>500
DATE
230
LCD
(Touch screen)
REVISIONS
1,900
SYM.
120
2,200
Note: Dimension of Isolator shall be submitted later.
・ Depth 1,230mm
・ Weight (TBA)
・ Maitenance space
・ Front side : 1,000mm, Rear side : 600mm
The dimensions may be changed after detail design