Digital Multimeter: Instruction Manual
Digital Multimeter: Instruction Manual
CD800F
/ / / Voltage input prohibited
After measurement, always turn the function switch to the OFF position. from damage caused by falling, etc.
EF + or - AC/DC 1000 V AC/DC 1000 V • Accessory : Check that the test leads are free from irregularities such as
4-3 Low battery indication wire disconnection and crack.
When the batteries are exhausted until the supply voltage drops below about • Battery: Install the battery before using the meter for the first time. Ensure
[2] APPLICATIONS AND FEATURES that the low battery indication is not displayed and, if it is displayed,
2.3 V, the indicator lights on the display. Replace the batteries when this
2-1 Applications indicator appears. replace the battery with new one. If nothing is displayed, the battery may be
DIGITAL MULTIMETER This instrument is a digital multimeter with rms value response, designed for
exhausted totally (see 6-4).
• Test lead wire disconnection can be checked by setting the function switch
measurements within the range specified as CAT.IV 1000 V in IEC61010. 4-4 Measurement function selection : SELECT button
to and shorting the test pins.
INSTRUCTION MANUAL 2-2 Features
When the SELECT button is pressed, the functions change as follows.
• Also check that the meter and your hands are not moistened by water, etc.
ACV position : ACV → Hz → ACV → …
• Safety design compliant to IEC61010. position : → → → → →…
• AC measurements with True RMS conversion. 5-2 AC voltage measurement (ACV), frequency measurement (Hz)
Dempa Bldg., 4-4 Sotokanda 2-Chome • High portability thanks to the case-integrated design. 4-5 Backlight : SELECT ( ) button Display Coverage Ranges
Chiyoda-ku, Tokyo 101-0021, Japan • Backlight. When the SELECT button is held depressed (for more than 2 sec.), the backlight ACV 0.005 - 1000 6.000/60.00/600.0/1000 V
• EF (Electric Field sensing). of the LCD turns on. Holding the same button depressed again turns it off. The
Hz 10.00 - 99.99 k 99.99/999.9/9.999 k/99.99 kHz
Measurement categories (Overvoltage categories) backlight also turns of automatically in about 30 seconds.
CAT. II : Primary circuit of equipment with a power cord to be connected to a The accuracy-assured frequencies of the ACV measurement are 45 Hz to 500
mains socket. 4-6 Range Hold : RANGE button Hz (sine wave AC).
CAT.III : Primary circuit of equipment that inputs power directly from the Press the RANGE button momentary to set the manual range mode (AUTO Hz input sensitivity : 10.00 to 9.999 kHz: ≥1 Vrms. 10.00 kHz or more: ≥5 Vrms.
02-1704 2040 6006
distributor and the circuit from the distributor to the mains socket. disappears in the display). In manual range mode, press the button again to step
CAT.IV : Circuit from the leading wire to the distributor. through the ranges. To return to the auto mode, press and hold the button for 1 Set the function switch to ACV.
Each press of the SELECT button
sec. or more (then ‘AUTO’ is shown).
[1] SAFETY PRECAUTIONS Manual range hold mode is not available in the Hz, , , and EF functions. alternates ACV and Hz.
Before use, read the following safety precautions.
4-7 Relative value measurement : △ REL button While selecting ACV, appears on the
This instruction manual explains how to use your new digital multimeter CD800F display when a voltage of 20 V or more
safely. Before use, please read this manual thoroughly. After reading it, keep it When the △ REL button is pressed, △ appears on the display, the measuring
range is fixed and the display shows the relative values assuming that the value is input.
together with the product for reference to it when necessary. At the moment the input exceeds 20 V,
If you use the product in a method not specified in this manual, the protection at the moment the button is pressed is 0 (reference value). When the button is
pressed again, △ disappears and the relative value measurement is canceled. the buzzer beeps and the backlight
function of the product may be imperiled.
The instruction given under the heading of “ WARNING” and “ CAUTION” must Relative value measurement mode is not available in the Hz, , and EF flashes to indicate it.
be followed to prevent accidental burn or electrical shock. functions.
1-1 Explanation of Warning Symbols [3] NAMES OF COMPONENT UNITS 4-8 MAX/MIN memory : △ REL (MAX/MIN) button 5-3 DC voltage measurement (DCV)
The meaning of the symbols used in this manual and attached to the product is 3-1 Multimeter and test leads When the △ REL button is held depressed, the meter enters the MAX/MIN
Display Coverage Ranges
as follows. mode, in which the measurement range is fixed and the Auto Power Save and
Strap hole DCV 0.0 m - 1000 600.0 m/6.000/60.00/600.0/1000 V
: Very important instructions for safe use. Removable test pin covers Relative value measurement functions are canceled.
Test pins View when not attached
• The WARNING messages are intended to prevent accidents to operating EF antenna position • Every time the SELECT button is pressed, the displayed information changes Set the function switch to DCV.
personnel such as burn and electrical shock. as follows : Current measurement display (MAX MIN displayed) → MAX
appears on the display when a
• The CAUTION messages are intended to prevent damage to the instrument. value display (MAX displayed) → MIN value display (MIN displayed) →
Current measurement display (MAX MIN displayed) → … voltage of 20 V or more is input.
Symbols attached to the product HOLD button
At the moment the input exceeds 20 V,
: Symbol soliciting reference to this manual before use • Current measurement display : The meter stores the maximum and minimum
△ REL button the buzzer beeps and the backlight
: Double or enhanced insulation values while displaying the current measurement value. The buzzer beeps
every time a value is updated. The maximum and minimum values can be flashes to indicate it.
: Ground : Resistance : Diode
: Buzzer : Capacitance : Backlight checked by pressing the button to view the MAX value display and MIN value
Finger guards display. To cancel the MAX/MIN mode, press the button for 1 sec. or more.
1-2 Warning Instructions for Safe Use Display
• MAX value display : Maximum value measured since the entry in MAX/MIN
Removable test pin covers mode.
WARNING When covered: CAT.IV 1000 V
SELECT button
When uncovered: CAT.II 1000 V • MIN value display : Minimum value measured since the entry in MAX/MIN
The following instructions are intended to prevent personal injury such as mode.
burn and electric shock. Be sure to follow them when using the tester. RANGE button
Test probe (red) The MAX/MIN mode can also be entered when the relative value measurement 5-4 Resistance ( ), diode ( ), continuity ( ) , capacitance ( )
1. This instrument is a digital multimeter for metering low voltages. Never function is active ( △ displayed). In this case, the MAX/MIN mode displays the
use it on electric circuits that exceed CAT.IV 1000 V. Test probe (black) relative values assuming that the value at the moment the button is pressed is 0 WARNING
2. Pay special attention when measuring the voltage of AC 33 Vrms (46.7 V Power/function switch (reference value). • Never apply voltage to the input terminals.
peak) or DC 70 V or more to avoid injury. MAX/MIN memory mode is not available in the Hz, , , and EF functions.
3. Never apply an input signal exceeding the maximum rating input value (see 1-3). * The MAX/MIN mode is canceled when the function or range is switched. Set the function switch to
4. Never use the meter for measuring the line connected with equipment (i.e. Each press of the SELECT button switches the function in order of → →
3-2 Display → → …
motors) that generates induced or surge voltage since it may exceed the 4-9 Data Hold : HOLD button
maximum allowable voltage. When the HOLD button is pressed, the current display is hold ( appears
5. Never use meter if the meter or test leads are damaged or broken. on the display).The display will not be changed even when the input varies 5-4-1 Resistance measurement ( )
6. Never use uncased meter or the meter without the lid. thereafter. Press the button again to cancel the Data Hold mode ( on the
Unit Display Coverage Ranges
7. Always keep your fingers behind the finger guards on the probe when display disappears). This function is not available in the EF function.
making measurements. * The Data Hold mode is also canceled when the function switch is switched or 0.0 - 60.00 MΩ 600.0/6.000 k/60.00 k/600.0 k/6.000 M/60.00 MΩ
8. Be sure to disconnect the test pins from the circuit when changing the function. the RANGE or SELECT button is pressed.
The open voltage across the measurement terminals is about DC 1.2 V.
9. Before starting measurement, make sure that the function and range are
properly set in accordance with the measurement. : Voltage alarm : Data Hold indicator 4-10 Disable Buzzer Resistor If measurement is likely to be influenced
10.Never use meter with wet hands or in a damp environment. : Auto Range indicator : Low battery indication When the meter is switched on while holding the △ REL button displayed, the by noise, shield the object to measure
11.Never open tester case except when replacing batteries. : Auto Power Save indicator : Relative operation indicator display shows for 2 seconds and the buzzer beep is canceled. Even when with negative potential (COM). If a finger
Do not attempt any alteration of original specifications. : Continuity check : Diode : Capacitor the buzzer is canceled, it still beeps in the case of OL alarm, in the continuity touches a test pin during measurement,
12.To ensure safety and maintain accuracy, check the meter in the start-up : Alternative Current : Direct Current : MAX/MIN mode indicator check, when the meter is turned on and before Auto Power Save. To enable all measurement will be influenced by the
inspection as well as in the inspection/calibration to be performed at least of the buzzer sounds, turn the meter off then on again. resistance in the human body, and that
once a year. 3-3 Attaching the strap * This mode cannot be used when the Auto Power Save function is canceled. results in measurement error.
13.The meter is for indoor use only. Hand strap
14.Wear insulating protective gear when using the meter with equipment Insert the Hand strap into the strap hole as
containing a hazardous live part. Also be sure to observe your local and shown in the figure.
national safety rules.
15. Always use the meter in a specified method to prevent the protective
function from being imperiled.
− 1 − − 2 − − 3 − − 4 −
5-4-2 Diode test ( ) Note: Because of the high 7-2 Repair 8-2 Optional accessory
sensitivity, the EF sensing Customers are asked to provide the following information when requesting Hanger magnet: HM-1
Display Coverage Note may be activated at a services:
distance of some tens of 1. Customer name, address, and contact information
Open voltage across input terminals: About 3.2 V centimeter apart from a
0.000 - 3.000 V 2. Description of problem
“OL” is displayed at 3.000 V or more. source of high frequencies 3. Description of product configuration 8-3 Measurement ranges and accuracies
such as an inverter circuit. 4. Model Number
Forward test Reverse test Accuracy-assured temperature/humidity ranges: 23±5 ºC, ≤ 80 %RH, no
Diode 5. Product Serial Number
condensation.
6. Proof of Date-of-Purchase
rdg: reading. dgt: digits (lowest digits)
7. Where you purchased the product
As the ACV measurements employ the rms value response, the accuracy-
Please contact Sanwa authorized agent / distributor / service provider, listed in
Cathode Anode [6] MAINTENANCE our website, in your country with above information. An instrument sent to
assured ranges and crest factor become as follows.
WARNING Accuracy range: 1 % to 100 % of measurement range.
Sanwa / agent / distributor without those information will be returned to the
Crest factor CF: Full scale CF < 1.8, half scale CF < 3.6.
customer.
1. This section is very important for safety. Read and understand the
following instruction fully and maintain your instrument properly. Note: Function Range Accuracy Remarks
Example of Good item: Example of Good item:
Forward voltage “OL” display 2. The instrument must be calibrated and inspected at least once a year to 1) Prior to requesting repair, please check the following: 6.000 V ± (1.2 %rdg+9 dgt) Input resistance: About 10 MΩ
drop display Example of NG item:
maintain the safety and accuracy. • Capacity of the built-in batteries and polarity of installation. • Accuracy-assured
Example of NG item: Other display AC voltage 60.00 V
0.000 V display, • Discontinuity of the test leads. ± (1.2 %rdg+5 dgt) frequencies: 45 Hz – 500 Hz
“OL” display 2) Repair during the warranty period: ACV 600.0 V
6-1 Maintenance and inspection The failed meter will be repaired in accordance with the conditions stipulated 1000 V ± (1.5 %rdg+7 dgt)
5-4-3 Continuity check ( ) in 7-1, Warranty and provision.
1) Appearance 99.99 Hz Input resistance: About 10 MΩ
Display Coverage Note • Is the appearance not damaged by falling? 3) Repair after the warranty period has expired: • Accuracy not assured below
• When the original functionality is expected to be restored by repair, we will Frequency 999.9 Hz
2) Test leads ± (0.5 %rdg+3 dgt) 10 Hz.
0.0 - 600.0 Ω Open voltage across input terminals: About 1.0 V • Is the cord of the test leads not damaged or the core wire not exposed at repair the product upon request and payment by the customer. Hz 9.999 kHz
• Sensitivity 10 Hz: ≥ 1 Vrms
• In some cases, repair and transportation cost may become higher than the
any place of the test leads? 99.99 kHz 10 kHz: ≥5 Vrms
price of the product. Please contact Sanwa authorized agent/service provider
The buzzer beeps at 10 to 50 Ω or less. If any of the above is found with the appearance, do not use the equipment in advance. 600.0 mV Input resistance: About 10 MΩ
and have it repaired. • The minimum retention period of service functional parts is six (6) years after 6.000 V
the discontinuation of manufacture. This retention period is the repair DC voltage ± (0.8 %rdg+3 dgt )
6-2 Calibration warranty period. Please note, however, if such functional parts become DCV
60.00 V
The manufacturer may conduct the calibration and inspection. For more unavailable for reasons of discontinuation of manufacture, etc., the retention 600.0 V
information, please contact the dealers. period may become shorter accordingly. 1000 V ± (1.1 %rdg+5 dgt)
4) Precautions when sending the product to be repaired 600.0 Ω • Open voltage: About DC 1.8 V
6-3 Cleaning and storage • To ensure the safety of the product during transportation, place the product in
6.000 kΩ • Measurement current varies
CAUTION a box that is larger than the product 5 times or more in volume and fill ± (1.2 %rdg+5 dgt) depending on the resistance
cushion materials fully. Resistance 60.00 kΩ
value of the object measured.
1. The main unit is not resistant to volatile solvent and must not be cleaned • Clearly mark “Repair Product Enclosed” on the box surface. 600.0 kΩ
with lacquer thinner or alcohol. If it gets dirty, wipe lightly with a soft cloth • The cost of sending and returning the product shall be borne by the customer.
moistened with a small amount of water. 6.000 MΩ ± (2.0 %rdg+5 dgt)
2. The main unit is not resistant to heat. Do not place it near a source of high heat. 60.00 MΩ ± (4.0 %rdg+5 dgt)
7-3 SANWA web site
3. Do not store the instrument in a place where it may be subjected to Open voltage: About DC 3.2 V
excessive vibrations or from where it may fall. http://www.sanwa-meter.co.jp Diode test “OL” displayed at 3.000 V or more.
5-4-4 Capacitance measurement ( ) E-mail: [email protected]
4. For storing the instrument, avoid hot, cold or humid places or placed
display Coverage Range under direct sunlight or where condensation is anticipated. Open voltage: About DC 1.0 V
5. When the instrument is not to be used for a long period, be sure to Continuity check Buzzer beep generated at 10 to
0.00 - 600.0 μF 60.00 n/600.0 n/6.000 μ/60.00 μ/600.0 μ remove batteries from it. 50 Ω or less.
Discharge the capacitor before 6-4 Battery replacement [8] SPECIFICATIONS 60.00 nF
± (3.0 %rdg+10 dgt)
Auto range only.
measurement. 600.0 nF Accuracy with a capacitor with
WARNING 8-1 General specifications Capacitance low leak current such as a film
It takes a while to measure large 6.000 μF
capacitance. 1. If the rear case or the battery lid is removed with input applied to the input capacitor or equivalent.
Operation method △ - Σ method 60.00 μF ± (5.0 %rdg+10 dgt) Less than 10 nF add +15 dgt to
This measurement is not suitable for terminals, you may get electrical shock. Before starting the work, always
AC detection method True RMS method (AC coupling) 600.0 μF the accuracy.
measurement of a capacitor with a make sure that no input is applied.
high leak current such as an 2. Before starting the work, be sure to turn OFF the main unit power and Display Max. 6000 counts
At the standard sensing voltage of Sensing frequencies: 50/60 Hz.
Electric field
electrolytic capacitor. release the test leads from the circuit. about 60 V or more, the bar graph and Sensing antenna: Near ▲ on top
sensing
Sampling rate Max. approx. 5 times/sec. intermittent sound vary in 5 steps. left of main unit.
EF
Contact type EF sensing : Test pin
Batteries 1 Using a Phillips screwdriver, turn
Overload indication “ OL” mark indication on digital display
the battery lid retaining screw
(x1) until it becomes loose. Range selection Auto and Manual
Accuracy calculation method
2 Press the position marked Example) AC voltage measurement (ACV)
PUSH to lift the battery lid, and Polarity switching Auto (“-” indicated when negative voltage is input) Displayed value: 100.0 V
then remove it. Range accuracy: 600.0 V range ±(1.2 %rdg + 5 dgt)
5-5 EF (Electric Field) sensing 3 Replace the batteries by taking Low battery indication mark displayed when battery voltage drops at 2.3 V or less. Error: ±(100.0 V x 1.2 %rdg + 5 dgt) = ±1.7 V
WARNING care of the polarity. Operating environmental Altitude ≤2000 m, indoor use, pollution degree II True value: 100.0 V ±1.7 V (between 98.3 - 101.7 V )
4 Attach the battery lid and conditions * In the 600.0 V range, 5 dgt corresponds to 0.5 V.
1. Before EF sensing, check the operation of this instrument using a known tighten the retaining screw.
power source. Operating temperature/ -10 ºC to 40 ºC.
humidity ranges Humidity range is as follows (without condensation):
2. Always keep your fingers behind the finger guards on the probe when [7] AFTER-SALE SERVICE Max. 80 %RH at 5 ºC to 31 ºC, decreasing linearly to 50 %RH at Specifications and external appearance of the product described
making EF sensing. 40 ºC. above may be revised for modification without prior notice.
3. Note that the voltage is not always absent and that a voltage below the 7-1 Warranty and provision Storage temperature/ -20 ºC to 40 ºC: ≤80 %RH (without condensation).
sensing voltage may exist. Sanwa offers comprehensive warranty services to its end-users and to its humidity range 40 ºC to 50 ºC: ≤70 %RH (without condensation).
product resellers. Under Sanwa's general warranty policy, each instrument is (Batteries should be removed when the instrument is not to be
1 This function identifies the presence of voltage in a simplified manner by warranted to be free from defects in workmanship or material under normal use used for a long period.)
sensing the electric field generated by AC voltage. for the period of one (1) year from the date of purchase. Temperature coefficient Below 18 ºC and above 28 ºC: Accuracy x 0.15 should be added
Sensing voltage reference: A voltage or electric field of about 60 V or more This warranty policy is valid within the country of purchase only, and applied per ºC. (Accuracy x 0.25 should be added in the function.)
can be sensed.
only to the product purchased from Sanwa authorized agent or distributor. Power supply LR03 (“AAA”-size alkaline battery)1.5 V × 2
2 When the function switch is set to EF, “EF” is displayed. Sanwa reserves the right to inspect all warranty claims to determine the extent
3 Antenna to which the warranty policy shall apply. This warranty shall not apply to Auto Power Save Power Save in about 15 minutes after last operation. Typ. 20 µA
• Noncontact type : An antenna is provided near the ▲ marking on the top disposables batteries or any product or parts which have been subject to one of
left of the main unit. the following causes: Current drain About 1.5 mA (backlight off). max. about 38 mA
• Contact type: Bring the test pin of a test lead (either red or black) in contact 1. A failure due to improper handling or use that deviates from the instruction
manual. Battery life About 600 hours (backlight off)
with the target.
More accurate sensing is possible by distinguishing the non-grounded and 2. A failure due to inadequate repair or modification by people other than Sanwa Dimensions & mass 166 (H) x 100 (W) x 43 (D) mm, about 360 grams (incl. batteries)
grounded sides. “-” is displayed and the buzzer beep is generated on the service personnel.
non-grounded (hot) side, while “EF” remains displayed and the buzzer beep 3. A failure due to causes not attributable to this product such as fire, flood and Test lead length About 0.8 m
is not generated on the grounded side. other natural disaster.
4. Non-operation due to a discharged battery. Safety standards IEC61010-1, IEC61010-2-030, IEC61010-2-33, IEC61010-31
* “EF” may sometimes become “-” even on the grounded side. This happens CAT.IV 1000 V
when the wiring is long, etc. 5. A failure or damage due to transportation, relocation or dropping after the
purchase. EMC Directive, RoHS IEC61326 (EMC), EN50581 (RoHS)
Directive
Accessories Instruction manual, “AAA”-size alkaline battery x 2, hand strap
− 5 − − 6 − − 7 − − 8 −