The communication via MODBUS is a property of the resource (hardware) and can only be defined in the
program instance of the resource. In the operating system of all PES of HIMA the slave function of MODBUS is
implemented. Using the software building block HK-MMT-3 each PES of HIMA can operate as MODBUS
master.
In the following table it is assumed that a configuration with resources already exists and in the resource a
program instance exists.
A definition of a bus for the MODBUS slave function is not necessary. Setting of the slave address by the DIP
switches on the CPU of the PES.
Slave-System
Master-System
Same procedure as in the slave system. Additionally a software building block HK-MMT-3 has to be
implemented in the program. See description in the HELP page or printout of the manual.
The import variables of the slave system are the export variables of the master system and vice versa.