Process Indicators: Ordering Information

The document provides specifications for several process indicator models. The models can accept various sensor inputs like thermocouples, RTDs, and analog voltage/current signals. They have displays, alarms, and communication capabilities. Key features include temperature and analog input measurement ranges, resolution, temperature units, alarm outputs, and certifications for EMC compliance and safety standards.

Uploaded by

Rajesh Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
293 views3 pages

Process Indicators: Ordering Information

The document provides specifications for several process indicator models. The models can accept various sensor inputs like thermocouples, RTDs, and analog voltage/current signals. They have displays, alarms, and communication capabilities. Key features include temperature and analog input measurement ranges, resolution, temperature units, alarm outputs, and certifications for EMC compliance and safety standards.

Uploaded by

Rajesh Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Process Indicators

• Flush Mounting Version 96X48 mm with 7 segment display


• Thermocouple (J, K, T, R & S) / RTD 3-wire (Pt-100) sensor inputs
• Analog Inputs (0-10 VDC / 0-20mA / 4-20mA), mV (Linear) - 5 to 56mV
• Alarm Outputs, Analog (0-20mA/ 4-20mA or 0-10V/ 0-5V) & Relay 5A for alarm indication
• Configurable Band, Deviation Alarms
• °C & °F temperature unit selectable
• Short depth of 65 mm
• RS 485 Communication
• IP 20 (For terminal and enclosure) & IP 55 (For Front Panel only)

Ordering Information
Cat. No. Description
PIA200 180-270 VAC, Process Indicator, Analog Input (0-10 VDC / 4-20 mA)
PIT200 180-270 VAC, Process Indicator, Thermocouple & RTD input
PIB110 85-270 VAC/DC, Process Indicator, Analog Input (0-10 VDC / 4-20 mA),
Thermocouple & RTD Input, 24 VDC sensor supply
PIB120 85-270 VAC/DC, Process Indicator, Analog Input (0-10 VDC / 4-20 mA),
Thermocouple & RTD Input, Alarm Outputs - Analog (0-10 V / 0-5 V,
0-20 mA / 4-20 mA) & Relay 5A for alarm indication, 24 VDC sensor supply
PIB12C 85-270 VAC/DC, Process Indicator, Analog Input (0-10 VDC / 4-20 mA),
Thermocouple & RTD Input, Alarm Outputs - Analog (0-10 V / 0-5 V, 0-20 mA /
4-20 mA) & Relay 5A for alarm indication with RS-485 Modbus communication,
24 VDC sensor supply

222
Process Indicators

Cat. No. PIA200 PIT200 PIB110 PIB120 PIB12C


Parameters
Supply Voltage ( ) 230V AC, ± 20% 85 to 270V AC/DC
Frequency 50/60 Hz
Temperature Sensors/ Inputs Current, Thermocouples: Thermocouples: J, K, T, R, S
Voltage J, K, T, R, S RTD input (2 wire & 3 wire)
RTD (Pt100) Analog inputs: mV, Current, Voltage
(2 wire & 3 wire)
Measurement Ranges Voltage : PT100 : -200 to 850 PT100 : -200°C to 850°C J : -200°C to 750°C
0 to 10VDC J : -200 to 750 K : -200°C to 1350°C T : -200°C to 400°C
Current : K : -200 to 1350 R & S : 0°C to 1750°C Analog Inputs: Voltage : 0 to 10VDC
0 to 20mA and T : -200 to 400 Current : 0 to 20mA, 4 to 20 mA
4 to 20mA R & S : 0 to 1750 mV (Linear) : - 5 to 56mV
Resolution Decimal point J, K, T, PT-100: J, K, T, PT-100: J, K, T, PT-100: 1° / 0.1°
position 1°C / 0.1°C 1°C / 0.1°C R & S: 1°
selectable: R & S: 1°C R & S: 1°C Decimal point position selectabel
Current: 1 / 0.1 / Analog Input: for analog input:
0.01 / 0.001 1° / 0.1° / 0.01 / Voltage: 1 / 0.1 / 0.01 / 0.001
Voltage: 1 / 0.1 / 0.001 Current: 1 / 0.1 / 0.01 / 0.001
0.01 / 0.001
Temperature Unit N.A °C /°F (User selectable)
Error Indications Sensor break, Over range and Under range
Display 4 Digit, 7 Segment display, Red color
Keypad 4 keys for digital setting
Alarm output 1 NO & NC 5A @ 250VAC/ 24V DC
N.A
Alarm output 2 (SPDT)
Analog DC output N.A Re-transmission :
Current: 0 to 20mA/ 4 to 20mA or
Voltage: 0 to 10V/ 0 to 5V
Analog output update rate N.A 100 msec.
Alarm types N.A Absolute (High/Low/Band),
Deviation (High/Low/Band)
Sensor supply 24 VDC
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -20°C to 75°C (-4°F to 167°F)
Humidity (Non-condensing) 95% RH (non-condensing)
Enclosure Flame Retardant UL94V0
Dimensions (W x H x D) (in mm) 96 x 48 x 70.6
Weight (Unpacked) 64g
Mounting Flush / Panel Mounting

Certification RoHS Compliant

Degree of Protection IP 20 Terminal & Enclosure, IP 55 for Front plate

EMI / EMC
Harmonic current emissions IEC 61000-3-2
ESD IEC 61000-4-2
Radiated Susceptibility IEC 61000-4-3
Electrical Fast Transients IEC61000-4-4
Surge IEC61000-4-5
Conducted Susceptibility IEC 61000-4-6
Voltage Dip (AC) & Short interruptions IEC 61000-4-11
Conducted Emission CISPR 11
Radiated Emission CISPR 11
Voltage Fluctuations and flicker IEC 61000-3-3

Safety Compliance:
Test Voltage IEC 60255-5
Impulse voltage IEC 60255-5
Single Fault IEC 61010-1
Insulation Resistance UL 508, > 100MΩ
Leakage Current UL 508, < 3 mA

Environmental
Cold Heat IEC 60068-2-1
Dry Heat IEC 60068-2-2
Component Temperature Rise IEC 61010-1

223