0% found this document useful (0 votes)
273 views1 page

Quick Start Guide: Default Parameters

The document provides instructions for configuring a USR-DR301 serial to Ethernet converter. It describes connecting the device to an Ethernet router or PC using an Ethernet cable and connecting a serial device via an RS-232 cable. It notes the default IP address of 192.168.0.7 and instructs the user to assign their computer an IP in the same range to access the web configuration page. The summary provides the essential setup steps and default network parameters.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
273 views1 page

Quick Start Guide: Default Parameters

The document provides instructions for configuring a USR-DR301 serial to Ethernet converter. It describes connecting the device to an Ethernet router or PC using an Ethernet cable and connecting a serial device via an RS-232 cable. It notes the default IP address of 192.168.0.7 and instructs the user to assign their computer an IP in the same range to access the web configuration page. The summary provides the essential setup steps and default network parameters.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

2.Serial Port 4.

Configure USR-DR301 via Web page

RS-232 Terminal Port ■ Assign a static IP address to your computer in the


Quick Start Guide 192.168.0.2 to 192.168.0.254 range.
Tiny Size RS232 to Ethernet Serial Converter
Mask 255.255.255.0. This is necessary to ensure that
MODEL USR-DR301
your computer can communicate with DR301 converter

■ The default IP address is 192.168.0.7 Open your web

Pin Definition Description browser and enter this IP to connect with DR301 for
configure
Power supply: 5-36V DC
Power
1
Interface
Wiring needs to check Default Parameters
marks ‘+’ “-”
User Name admin

RS232 Based on the photo,from Password admin


1. Hardware Installation 2
Terminal right to left is Tx, Rx, G IP address 192.168.0.7

 Use a standard Ethernet cable to connect the DR301 Mask 255.255.255.0


3 RJ45 Port Ethernet Port Gateway 192.168.0.1
to an Ethernet router or connect it directly to a PC.
Work Mode TCP Client
 RS232 can connect with a PC or other serial port Local Port 0

device by serial cables


3. Software Installation Baud Rate 115200
 SetupSoftware: :https://www.usriot.com/support/downl Target Port 8234
oads/usr-m0-setup-software-v224288.html
Target IP 192.168.0.201
Notes: Be sure you have administrative rights and
Parity bit/Data bit/Stop bit None/8/1
disable any firewalls/anti-virus software when install

software.

You might also like