Ariston Instantaneous Electric Water Heater Manual Optimized
Ariston Instantaneous Electric Water Heater Manual Optimized
Ariston Instantaneous Electric Water Heater Manual Optimized
1. This manual is an integral part of the product. Keep it with care with the appliance, and hand
it on to the next user/owner in case of change of property.
2. Read the instructions and warning in this manual carefully, they contain important information
regarding safe installation, use and maintenance.
3. The appliance must be installed and commissioned by a qualified technician in accordance
with local legislation and health and safety regulations. All power circuits must be shut off
before you open the terminal block.
4. DO NOT use the appliance for any other than its specified use. The manufacturer is not liable
for damage resulting from improper or incorrect use or failure to observe the instructions
given in this manual.
5. Incorrect installation can result in damage to property and injury to persons and animals; the
manufacturer is not liable for the consquences.
6. DO NOT leave the packaging materials (staples, plastic bags, expanded polystyrene, etc.)
within the reach of children - they can cause serious injury.
7. The appliance is not intended for use by persons under 8 years of age, with reduced
physical, sensory or mental capacity, or lacking the requisite experience and familiarity,
unless under supervision or following instruction in the safe use of the appliance and the
hazards attendant on such use. DO NOT permit children to play with the appliance. User
cleaning and maintenance may not be done by unsupervised children.
8. Any repairs, maintenance, plumbing and electrical hookup must be done by qualified
technicians using original spare parts only. Failure to observe the above instructions can
compromise the safety of the appliance and relieves the manufacturer of any liability for the
consequences.
9. The hot water temperature is regulated by a thermostat which also acts as a safety device to
prevent dangerous overheating.
10. The electrical hookup must be done as indicated in this manual.
11. If the appliance is equipped with a power cord, the latter may only be replaced by an
authorised service centre or professional technician.
12. Make sure to drain the appliance when it is out of service or in an area subject to subzero
temperatures.
13. Do not leave flammable materials in contact with or in the vicinity of the appliance.
2
Symbol Meaning
Failure to observe this warning can result in injury, which may even be fatal in certain circumstances
Failure to observe this warning can result in damage or injury, even to property; plants and animals
Observe the product's general and specific safety instructions.
3
TECHNICAL CHARACTERISTICS
For the technical specifications, refer to the nameplate (the nameplate is located on the right side
of the water heater).
Product Information
Power (kW) 9.5
Voltage 220-240V
Phases Mono
Installation Hidden Installation
Constructions Close Outlet
Model Refer to name plate
Frequency 50/60hz
Amper 39,6
Water Protection IP24
Pipe Connection 1/2" BSP
Minimu, Water Flow 2.1L/Min
Qelec (kWh) 2,191
max water pressure (bar) 8 bar
Load Profile XS
Lwa (db) 15db
wh 39%
Rated Volume (lt) 400cc
Weight 2400 gr
Dimensions 304 mm x 178 mm x 98 mm
The power consumption data in the table and the other information given in the Product Data
Sheet (Enclosure A to this manual) are defined in relation to EU Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar devices, stipulated
in regulation 812/2013, are not intended to be used in such assemblies.
Products equipped with a regulator knob have the thermostat positioned in the <ready to use
setting indicated in the Data Sheet (Enclosure A), according to which the relevant energy class
has been declared by the manufacturer.
The product should be connected only to a supply with the relevant system
impedance no more than 0.237 ohm.
Restrictions to connection may be imposed by the supply authority on the use of
equipment in the actual relevant system impedance at the interface point on the
user's premise exceeds 0.237 ohm.
This appliance is conforming with the international electrical safety standards IEC
60335-1 and IEC 60335-2-35. When present, The CE marking of the appliances
attests its conformity to the following EC Directives, of which it satisfies the
essential requisites:
- LVD Low Voltage Directive: EN 60335-1, EN 60335-2-35, EN 60529, EN 62233, EN 50106.
- EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3,
EN 61000-3-11 and EN 61000-3-12.
- ERP Energy related Products: Eu812, Eu814, EN50193-1-2013
4
INSTALLATION INSTRUCTIONS
The appliance must be installed and commissioned by a qualified technician in accordance with
established regulations and local health and safety regulations..
1. Open the four screws located on the top and bottom of the device and remove the cover
from base.
2. Fix the base horizontally against a wall or side of cabinet, ground wire must be connected
to the unit, the inlet and outlet water pipes are on the down/bottom side of the unit. Use 4
mounting screws provided.
N
G
L
AURES
SLIM MULTI
3. Use the supplied water filter and PRD on the inlet water pipe line (see attached
separate diagram Page 9).
4. Connect the incoming water line (cold only) to the inlet water pipe on the bottom left side and
the outgoing water line to the outlet water pipe on the bottom right side. Open the mains cock
of water supply and check there is no water leakage from the unit.
5. Before performing any operations, disconnect the appliance from the electricity mains using
the external switch then connect the power to cable to the appliance. The appliance must be
earthed and the earth cable (show with a letter in the drawing) is fixed to the terminal marked
by the symbol .
6. Turn on the unit and check that it is operating as required.
7. Reconnect the cover to the base with 4 screws.
8. It is required that a Ground Fault Circuit Interrupter/Earth Leakage Circuit Breaker be
incorporated in the circuit.
9. Make sure to install in the right way the pressure relief valve (supplied with the
product) before Inlet pipe.
10. It is required to install a flow control restrictor (AERATOR) at the sink or shower.
5
11. WARNING: UNIT MUST BE PROPERLY GROUNDED
12. THIS HEATER MUST HAVE ITS OWN INDEPENDENT CIRCUIT USING A
CORRECTLY RATED CIRCUIT BREAKER AND SUITABLE WIRE, SEE TABLE
RECOMMENDED CABLE.
OPERATING INSTRUCTIONS
1. Your new Instant Water Heater is flow activated. Regulate the knob in one of the 3 setting
power (Low, Med, High) the product will switch ON and turn on the hot water tap. the
heating element will work and warm the water only when there is a flow of water through the
appliance.. You will need to allow at least 2.1 liters per minute to flow through the unit in
order to activate the Instant Heating System. Run water through the heater for a few minutes.
2. Be sure to every so often clean the spray head of sediment to assure a smooth water flow.
3. Be sure to every so often clean the incoming water filter.
4. Be sure to install your Instant Water Heater in a heated location. The appliance cannot be
installed in areas where the temperature may drop critically and there may be a risk that ice
may form.
5. The user can adjust the hot water temperature regulating the setting power on the unit. the
user can choose till 4 setting poer position:
- Power - Heating element is off
- Low - Only the 1st Heating element switches on.
- Med - Only the 2nd heating element switches on.
- High - 1st and 2nd heating elements switch on, working together.
6
INSTALLATION REQUIREMENTS
A. A separate electrical line is required.
B. The device must be connected to a separate circuit breaker.
C. The recommended electrical cable for feeding the device, see table I (next page).
INSTALLATION
Device with 220-240V from 7kW up to 12kW & 400-415V 3 Phase
Thermostat 85
L L2 Heating Element
G N
R.R PCB
Switch Indicator
Terminal Terminal
Block Block
7
WARNING!
BEFORE BEGINNING ANY WORK ON THE ELECTRICAL INSTALLA-
TION BE SURE THAT THE CIRCUIT BREAKER IS IN THE “OFF” POSI-
TION TO AVOID DANGER OF ELECTRICAL SHOCK
SLIM MULTI
AURES
AURES
SLIM MULTI
8
Power Knob
Power Led
AURES Water Inler
Pressure Relief Valve
SLIM MULTI
Filter
Water Outlet
9
This product conforms to Directive
WEEE 2012/19/EU.
The symbol of the crossed waste paper basket on the appliance indicates that at the end of its
working life the product should be disposed of separately from normal domestic household rub-
bish, it must be disposed of at a waste disposal center with dedicated facilities for electric and
electronic appliances or returned to the retailer when a new replacement product is purchased.
The user is responsible for the disposal of the product at the end of its life at an appropriate waste
disposal center.
The waste disposal center (which using special treatment and recycling processes effectively
dismantles and disposes of the appliance) helps to protect the environment by recycling the
material from which the product is made.
For further information about waste disposal systems visit your local waste disposal center or the
retailer from which the product was purchased.
Product sizes
304
178
98
10
Troubleshooting
SYMPTOM POSSIBLE CAUSE SOLUTION
Water not hot Too much water flowing through Reduce the flow rate of the water via
enough the heater the outlet tap.
Reduction In tha ambient Switch to higher temperature setting.
temperature
Water ceases Blockage of spray head, twisted Clean or replace spray head, check
to flow or blocked flexible shower hose. for free passage of water through
hose. Replace as necessary.
No water supply. Check water supply, stop valve
Open? and no blockage.
Water Water pressure has dropped Increase hot water supply,
temperature below min. level.
varies from hot
to cold during
use
No hot water No electrical power Check the circuit breaker and check
despite fully voltage at the wiring block.
open hot water
The activation flow rate needed Clean filter screen
faucet
to turn on the heating element • Turn circuit breaker off
has not been reached. • Open hot valve to release pressure
from the unit.
• Turn circuit breaker on.
11
P.N. 198840D - 11/2018