Vindicator V5 IDS Data Sheet 2 PDF
Vindicator V5 IDS Data Sheet 2 PDF
Intrusion Detection
System (IDS)
Enterprise Intrusion Solution for Demanding Applications
F EAT U R E S
Data Processing - The embedded IDS scheme matches the operational reality based on individual authorization. Event
server software supervises system for the facility. The V5 IDS separates and system information from one or
equipment status and distributes alarm points into categories of more V5 IDS servers can be routed to
system status changes to operator importance as their status changes. a single or multiple VCC consoles to
interfaces and peripheral equipment. It An alarm’s priority affects the way it is create regionalized solutions and can
also accepts commands from operators displayed, the type of alarm employed be integrated with Computer Aided
and evaluates the significance of when the point goes off normal, and its Dispatch (CAD) platforms, resource
system events against defined “normal” position on the Action List screen. management platforms or emergency
conditions. The IDS server connects to response systems.
Enterprise Capabilities - When
Vindicator field devices over many
coupled with the powerful V5 ACS Powerful Administration and
media types including: RS485, fiber,
server, the enterprise potential of the Maintenance Interface - A single
Ethernet, serial, etc.
system is enhanced. The watchman’s V5 IDS server can be used as a remote
Various Alarm Types - The V5 IDS tour function can be used to ensure configuration interface for other
server supports multiple alarm types, proper, safe and regular rounds by V5 servers in the network and to
including standard, delayed, combined, staff personnel, ensuring credentials interface with downstream Vindicator
auto-secure, two-man access and are presented to a set of readers in transponders. The V5 IDS server
group access alarms. Each type serves a particular order within a specified speeds installation and enhances
a specific purpose in the site security amount of time. The global anti- troubleshooting by providing a powerful
plan and ensures that the security passback feature controls user access maintenance console for performing
device and network diagnostics.
Vindicator ® V5 Intrusion Detection System (IDS)
Enterprise Intrusion Solution for Demanding Applications
S P E C I F I C AT I O N S
Intrusion Detection Capacity (per server) Interfaces/Drivers Electrical Characteristics
• Sensor inputs: more than 20,000 multi-state inputs • Vindicator VCC Platform • Operating voltage: 9 to 18 VAC
• System has passed the “5-in-2” test • Logging/reporting printer • Power: configuration dependent
(capable of reporting five alarm events in less than • Vindicator Security Network • Transient and surge protection: 36 W max
two seconds)
• CCTV control • Ports 1.2 j 80 us 2400 V 12 A peak
Communication Ports
• Plasma display control • Input sensitivity: 0.0 to 5.0 V with 10 bit resolution
• Serial: 8 RS485, 4 RS232 and 1% accuracy
• SIA CIS Central Station
• LAN: 4, 100BaseT with TCP/IP
Environmental Requirements • Inputs configured for resistive load measurement
• Fiber optic: 1-4 optional 100FX optical (SM or MM) source of up to 10 mA at 5 VDC into 1K ohms
• Operating temperature: 0°C to +50°C
Mechanical Specifications • Sensor self testing: Automatic, programmed,
• Storage temperature: -25°C to +65°C random, or regular at average intervals (2 minutes
• Dimensions: 11.1"L x 10.5"W x 2.9"H
• Humidity: 8%-90% non-condensing to 22 days). Failed tests announced.
• Weight: 5 lbs
• Vibration operating: 8G peak swept-sine with Compatibility/Integration
• Mounted on sheet metal base plate, solid-state storage, 1G peak swept-sine with
NEMA enclosed product optional • CCTV: Many cameras, switchers, video motion
HDD option detection or DVR systems
• EMI/RFI gasket • Shock operation: 175G for 2 ms half-sine • Advanced technologies: Ground-based radar
• Field wire connectors: Removable plug type screw
• Sensors: Many interior or exterior sensor systems
jaw clamp terminal for 18 to 24 AWG solid or
stranded wire Enterprise Connectivity
VCC
• Open style architecture (LAN/WAN, Ethernet, SM
and MM fiber, RS232, RS485, FSK, TCP/IP)
V5 V5 Software Configuration
• Via Ethernet or RS485
VCN Encryption
• AES, DES, TDEA (DCID and NIST approved)
Certifications and Approvals
Vindicator Communications VC N
• Certified for nuclear facilities without waiver (USAF
Network (VCN) pending)
V 5 V 5
• FIPS 46-3, FIPS 197, DCID 6/9, SIA
• UL-1076/294/864, FCC Part 15,
Subpart J, Class A
VCN VCN
Field Sensors
ORDERING
V5 IDS Fiber & Memory Options for V5
548-54000-01 AE V5 IDS, AES Encryption, Wire
532-33302-01 Fiber Optic Multi-Mode Port
548-54000-02 AE V5 IDS, AES Encryption, MMFO
548-54000-03 AE V5 IDS, AES Encryption, SMFO 532-33302-02 Fiber Optic Single-Mode Port
548-64000-01 SE V5 IDS, AES Encryption, Wire
548-64000-02 SE V5 IDS, AES Encryption, MMFO Spares
548-64000-03 SE V5 IDS, AES Encryption, SMFO 292-33464-00 12 VDC Wall Plug Power Supply
908-33461-00 Installation, Operation and Maintenance Manual
V5 ACS
548-54100-01 AE V5 ACS, AES Encryption, Wire 536-33005-01 Communication I/O Module
548-54100-02 AE V5 ACS, AES Encryption, MMFO 544-33472-01 Serial Communication H/A, serial communications
548-54100-03 AE V5 ACS, AES Encryption, SMFO cable from V5 to display device
548-64100-01 SE V5 ACS, AES Encryption, Wire 548-51600-01 AE System Server Terminal (PC SmartPAC)
548-64100-02 SE V5 ACS, AES Encryption, MMFO
548-64100-03 SE V5 ACS, AES Encryption, SMFO