Material Safety Data Sheet: WWW - Smartlab.co - Id
Material Safety Data Sheet: WWW - Smartlab.co - Id
Material Safety Data Sheet: WWW - Smartlab.co - Id
01
For the full text of the H-Statements mentioned in this Section, see Section 16.
Pictogram
Precautionary statement(s)
P273 Avoid release to the environment.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing. Supplemental
Hazard Statements none
3.1 Substances
Synonyms : Sequestrene Na2
Disodium ethylenediaminetetraacetatedihydrate
Edetatedisodium saltdihydrate
Edathamil
EDTAdisodium salt
Formula : C10H14N2Na2O8.2H2O
Molecular weight : 372.24 g/mol
CAS-No. : 6381-92-6
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in
section 11
4.3 Indication of any immediate medical attention and special treatment needed
No data available
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal
technique (without touching glove's outer surface) to avoid skin contact with this product.
PT.SMART-LAB INDONESIA MSDS – ETHYLENEDIAMINETETRAACETIC ACID DISODIUM SALT Page 3
No: F/QCL/008 Rev.01
Dispose of contaminated gloves after use in accordance with applicable laws and good
laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC
and the standard EN 374 derived from it.
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0.11 mm
Break through time: 480 min
Material tested:Dermatril® (KCL 740, Size M)
Splash contact
Material: Nitrile rubber
Minimum layer thickness: 0.11 mm
Break through time: 480 min
Material tested:Dermatril® (KCL 740, Size M)
Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be
selected according to the concentration and amount of the dangerous substance at the specific
workplace.
Respiratory protection
For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle r (US) or type
ABEKP2 (EU EN 143) respirator cartridges. Use respirators and components tested and
approved under appropriate government standards such as NIOSH (US) or CEN (EU)..
10.1 Reactivity
No data available
Skin corrosion/irritation
No data available(Edetate disodium dihydrate)
Carcinogenicity
IARC: No component of this product present at levels greater than or equal to 0.1% is
identified as probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
No data available(Edetate disodium dihydrate)
Aspiration hazard
No data available(Edetate disodium dihydrate)
Additional Information
RTECS: AH4410000 To the best of our knowledge, the chemical, physical, and toxicological properties
have not been thoroughly investigated.
12.1 Toxicity
Toxicity to fish
LC50 - Lepomis macrochirus - 41 mg/l - 96 h
Contaminated packaging
Dispose of as unused product.
14.1 UN number
ADR/RID: - IMDG: - IATA: -
14.2 UN proper shipping name
ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
14.3 Transport hazard class(es)
ADR/RID: - IMDG: - IATA: -
14.4 Packaging group
ADR/RID: - IMDG: - IATA: -
14.5 Environmental hazards
ADR/RID: no IMDG Marine pollutant: no IATA: no
14.6 Special precautions for user
Further information
No data available
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.2 Chemical safety assessment
For this product a chemical safety assessment was not carried out
Further information
The above information is believed to be correct but does not purport to be all inclusive and shall be used only as
a guide. The information in this document is based on the present state of our knowledge and is applicable to
the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties
of the product. PT. Smartlab Indonesia Corporation and its Affiliates shall not be held liable for any damage
resulting from handling or from contact with the above product. See www.sigmaaldrich.com and/or the reverse
side of invoice or packing slip for additional terms and conditions of sale.