Cost Effective Modern Technology: Web Based
Cost Effective Modern Technology: Web Based
Cost Effective Modern Technology: Web Based
MODERN TECHNOLOGY
WEB BASED
D-100
The D-100 is the lowest cost
genset controller ready for
internet monitoring.
FEATURES COMMUNICATION
• Diesel and gas genset support • Idle speed control • 4-band GPRS modem (optional)
• 400 event logs, full snapshot • Battery charge run enabled • USB Device
• All parameters front panel • Combat mode support • J1939-CANBUS (optional)
editable • Multiple nominal conditions • Geo-locating through GSM
• 3 level configuration password • Contactor & MCB drive • Internet Central Monitoring
• 128x64 graphical LCD display • 4 quadrant genset power • SMS message sending
• 4 configurable digital inputs counters • E-mail sending
• 5 configurable digital outputs • Mains power counters • Free PC software: Rainbow Plus
• 3 configurable analog inputs • Fuel consumption counter • Modbus RTU
• CANBUS-J1939 • Modem diagnostics display
• 3 configurable service alarms • Configurable from USB & GPRS
• Dual mutual standby with • Free configuration program
equal aging of gensets • Allows SMS controls FUNCTIONALITIES
• Manual “speed fine adjust” on • Ready for central monitoring • AMF unit
selected ECUs • Mobile genset support • ATS unit
• Automatic fuel pump control • Automatic GSM geo-location • Remote start controller
• Disable protections feature • Easy USB firmware upgrade • Manual start controller
• Excess power protection • IP65 rating with optional gasket • Engine controller
• Reverse power protection
• Overload IDMT protection
• Load shedding, dummy load MEASUREMENTS
• Multiple load management • Mains & genset PN/PP voltages TOPOLOGIES
• Current unbalance protection • Mains & genset frequency • 3 ph 4 w, star & delta
• Voltage unbalance protection • Mains & genset phase currents • 3 ph 3 w, 2 CTs
• Fuel filling & fuel theft alarms • Mains & genset neutral currents • 2 ph 3 w
• Mains & genset, phase & total, • 1 phase 2 wires
kW, kVA, kVAr, pf
• Engine speed
• Battery voltage
COMMUNICATIONS
TECHNICAL SPECIFICATIONS
Alternator voltage: 0 to 300 V-AC (Ph-N) Operating temperature: -20°C to 70°C (-4 to +158 °F)
Alternator frequency: 0-100 Hz. Storage temperature: -40°C to 80°C (-40 to +176°F)
Mains voltage: 0 to 300 V-AC (Ph-N) Maximum humidity: 95% non-condensing.
Mains frequency: 0-100 Hz. IP Protection: IP65 from front panel, IP30 from the rear
Topology: 1-2-3 phases, with or without neutral (with gasket)
DC Supply Range: 8.0 to 36.0 V-DC. Dimensions: 133 x 107 x 46mm (WxHxD)
V-A-cos Accuracy: 0.5% + 1 digit Panel Cut-out Dimensions: 117 x 87 mm minimum.
kW-kVA-kVAr Accuracy: 1.0% + 1 digit Weight: 250 g (approx.)
Current consumption: 300 mA-DC max @ 12V-DC Case Material: High Temperature, non-flammable
Current Inputs: from current transformers. ../5A. ABS/PC
Digital inputs: input voltage 0 to 36 V-DC. Installation: Flat surface mounting on a Type 1 enclosure.
Analog input range: 0-5000 ohms. Rear retaining plastic brackets.
DC Outputs: Protected mosfet semiconductor outputs,
rated 1Amp@28V-DC CONFORMITY
Cranking dropouts: survives 0V for 100ms.
Charge Alternator Excitation: 2W. EU Directives Conformity
Display Screen: 2.9”, 128x64 pixels -2006/95/EC (low voltage)
USB Device: USB 2.0 Full speed -2004/108/EC (electro-magnetic compatibility)
Norms of reference:
EN 61010 (safety requirements)
EN 61326 (EMC requirements)
o
RAINBOW PLUS PROGRAM
O
Smartphone Support
Fleet Display on Map, online monitoring