0% found this document useful (0 votes)
548 views2 pages

Composite Curve

The document provides stream data for a process in a table, including temperature values for hot and cold streams. It asks to sketch composite curves for the streams with a minimum temperature difference (ΔTmin) of 10°C and determine the minimum hot and cold utility targets. The response sketches the composite curves, showing that the hot utility minimum (QHmin) is 5 MW occurring at 160°C, and the cold utility minimum (Qcmin) is 8.3 MW occurring at 150°C.

Uploaded by

teguh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
548 views2 pages

Composite Curve

The document provides stream data for a process in a table, including temperature values for hot and cold streams. It asks to sketch composite curves for the streams with a minimum temperature difference (ΔTmin) of 10°C and determine the minimum hot and cold utility targets. The response sketches the composite curves, showing that the hot utility minimum (QHmin) is 5 MW occurring at 160°C, and the cold utility minimum (Qcmin) is 8.3 MW occurring at 150°C.

Uploaded by

teguh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

The stream data for a process are given in Table 16.11.

Table 16.11 Stream data for Exercise 2.

Stream Heat Duty Total Heat Duty C


Ts (C) TT (C) Assumed TT (C)
(MW)
No. Type MW MW.K-1
1 Hot 160 40 40 3.6 -0.03
2 Hot 50 50 49 5 10.1 -5
3 Hot 140 110 110 1.5 -0.05
4 Cold 160 160 161 5 5
5 Cold 60 150 150 1.8 6.8 0.02

a. Sketch the composite curves for ΔTmin = 10◦C.


b. From the composite curves, determine the target for hot and
cold utility for ΔTmin10◦C.

a. Hot Stream 170


160 10.1 160
140 9.5 150 Hot Stream
140 Cold Stream
110 8 QHmin= 5 MW
130
50 5.4
120
49 0.4 110
40 0 100
Cold Stream 90
t (C)

60 8.4 80
70
150 10.2
60
160 10.2 50
161 15.2 40 Q req= 1,8 MW
30
20
10 Qc min= 8.3 MW
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

∆h (mw)
b.
ΔTmin10◦C.
Hot Pinch Point
QHmin= 5 MW 160 degC
Cold Pinch Point
150 degC

1.9