0% found this document useful (0 votes)
59 views3 pages

MD Singh Power Electronics Solution Manual To Chapter 16 Compress

This document contains 5 sections that discuss various power electronics concepts and calculations: 1) Calculating the KVA rating, voltage, and battery capacity required for an inverter with a given load, power factor, and efficiency. 2) Sizing the battery needed to supply backup power to a load for a given time period. 3) Calculating component values for a flyback switch-mode power supply circuit operating at given voltages and frequencies. 4) Determining the depth of heating from an induction coil operating at a given current, frequency, and resistance. 5) Computing the capacitance and power dissipation of a parallel plate capacitor with specified dimensions, dielectric constant, voltage, and phase
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views3 pages

MD Singh Power Electronics Solution Manual To Chapter 16 Compress

This document contains 5 sections that discuss various power electronics concepts and calculations: 1) Calculating the KVA rating, voltage, and battery capacity required for an inverter with a given load, power factor, and efficiency. 2) Sizing the battery needed to supply backup power to a load for a given time period. 3) Calculating component values for a flyback switch-mode power supply circuit operating at given voltages and frequencies. 4) Determining the depth of heating from an induction coil operating at a given current, frequency, and resistance. 5) Computing the capacitance and power dissipation of a parallel plate capacitor with specified dimensions, dielectric constant, voltage, and phase
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CHAPTER 16

16.1 Given: Load = 800 w, PF = 0.8, e = 85%.


Edc = 48 V, Back-up time = 30 min.
(i) KVA rating of inverter
Active Power
PF =
Total Rms Power

800
0.8 =
Total Rms Power

\ Total rms power = 1000 VA


\ VA rating of inverter = 1 KVA
KVA rating ¥ UPF
(ii) Voltage of rectifier =
Efficiency

1 KVA ¥ 0.8
= = 1 kW
0.850
(iii) Battery kW rating = Voltage ¥ current
1 kW = 48 ¥ Idc
\ Idc = 20.83 A.
A-H rating = 20.83 ¥ 1/2 = 10.5 AH.
16.2
Load KVA ¥ PF
(i) Battery (kW) =
Efficiency
50 ¥ 0.8
= = 44.44 kW.
0.90
\ Battery needs to supply 44.44 kW power.
Minimum allowable voltage battery
(ii) No. of cells =
Final voltage per cell.

210
= = 120.
1.75
No. of cells 120
(iii) No. of jars = = = 120
No. of cells per jar 6
94 Power Electronics

44.44
(iv) Cell size (kW) = = 120.
120
= 0.370 kW.
Two 75-AH cell battery is selected which has 0.426 kW discharge rate at 15 min back-up time
which is greater than required 0.370 KW.
16.3 E0 = 80 V, Es = 110 V, f = 16 kHz.
(i) E0 = Es d /1 - d
d 80
\ = = 0.73 \ d = 0.42
(1 - d ) 110
T = 1 = 62.5 usec
f

120
\ P0 = E0 . I0 \ I0 = = 1.5 A.
80
For a single transistor flyback smps, the minimum value of the inductance is given by
T
Lmin = (Es . d)2.
2 P0

62.5 ¥ 10-6
= (110 ¥ 0.42)2 ◊
2 ¥ 120
= 0.559 mH.
16.4 We have d = 25 cm = 0.25 cm N = 20 turns
I = 200 A F = 450 ¥ 103 Hz.
r = 6.8 ¥ 10–8 W - m.
Depth of heating is given by

r 604 ¥ 10-8
d = 503 ◊ = 503 m.
ur. f 1 ¥ 450 ¥ 103

assuming mr = 1 \ d = 190 ¥ 10–6 meters


d = 0.19 mm.
Now, heat per unit area of the surface is given by H = pa = 2p
2
Ê NI ˆ . r . mr ◊ F
ÁË ˜¯
l 107
2
Ê 20 ¥ 200 ˆ . -
= 2p Ë
(6.8 ¥ 10-8 ) ¥ 1 ¥ 450 ¥ 103
0.25 ¯ 107
= 6.28 ¥ 256 ¥ 106 ¥ (55.31 ¥ 10–6)
= 88.92 kW/m2
16.5 Area A = (20 ¥ 15) cm2 = 300 cm2 = 0.0300 m2
b = distance between electrodes = 1 cm = 0.01 m.
Solution Manual 95

Er = 3, cosq = 0.4, f = 20 ¥ 106 Hz.


V = 750 V.

Œ0 . Œr A 8.854 ¥ 10-12 ¥ 3 ¥ 0.0300


C = = = 79.69 ¥ 10–12 F.
b 0.01
cos q = 0.4 \ q = 66.42, d = 900 – 66.42 = 23.58 \ tan d = 0.44
Also, P = 2p f.c. V 2 tan d
= 2p ¥ 20 ¥ 106 ¥ 79.69 ¥ 10–12 ¥ 750 ¥ 750 ¥ 0.44
= 2478.5 Watts.