Check valve, description

Creates a back pressure to prevent reverse flow in the return circuit.


Hydraulic oil cooler directions: 147.1 kPa (1.5 kg/cm2) (21.3 psi) (1.47 bar)
Hydraulic oil tank directions: 294.2 kPa (3.0 kg/cm2) (42.7 psi) (2.94 bar)

Figure 1
Structure, check valve

1 Screw 6 Spring
2 Screw guide 7 Spring holder
3 O-ring 8 Spring guide
4 Check valve body 9 Nut
5 Valve seat 10 Lock nut

Check valve mounting position

Figure 2
Check valve mounting position

1 Hydraulic cooler 5 Check valve (1.5 k)


Main control valve → Oil cooler → Oil tank
2 Fan motor 6 Check valve (3.0 k)
Main control valve → Oil tank
3 Proportional relief valve 7 Hydraulic oil tank
4 Main control valve

NOTE!
When replacing and re-assembling, the check valve must be installed to open in the direction of the flow. If installed in the reverse
direction, excessive back pressure will build in the return circuit.