Error Code Error Cause Elimination E53: 50 650 69 0101E - REV A (GROVE RT-TM) .DOC / Rev. A / 2007-08-17 / RK
This service manual provides information on error codes, possible causes, and solutions for an iFLEX2 crane control system with iSCOUT expert compact. Common issues include incorrect setup, defective or disconnected sensors, invalid data files, and issues with the CAN bus data transfer. Solutions range from checking connections and setup, replacing sensors or central units, to updating software or crane data files.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
704 views1 page
Error Code Error Cause Elimination E53: 50 650 69 0101E - REV A (GROVE RT-TM) .DOC / Rev. A / 2007-08-17 / RK
This service manual provides information on error codes, possible causes, and solutions for an iFLEX2 crane control system with iSCOUT expert compact. Common issues include incorrect setup, defective or disconnected sensors, invalid data files, and issues with the CAN bus data transfer. Solutions range from checking connections and setup, replacing sensors or central units, to updating software or crane data files.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Service Manual iFLEX2 with iSCOUT expert compact
Error code Error Cause Elimination
Wrong setup of min. analog Analog input not supported Setup correct Flag in in DGA E53 inputs length1, angle1, 6.i.2 pressure1 No valid data in the crane Restore or upload valid crane Error in crane data file. data file during calibration. data file E56 Flash-EPROM defective Replace central unit Buffered data file does not Reset system contain valid data. E57 Error in buffered data file. Flash-EPROM defective Replace central unit CAN Bus cable between the Check the connection between central unit and the sensor the central unit and the sensor unit defective or not units Error in the CAN bus data connected. E61 transfer for all CAN units Can bus port in the central Replace the central unit unit defective Short circuit in a CAN Bus Replace Can Bus cable cable Cable between the central Check the cable to the sensor unit and the sensor unit unit defective. Error in the can bus data Can bus port in the central Replace the central unit E62 transfer of the pressure unit defective transducer sensor unit Can bus port in the sensor Replace the sensor unit unit is defective Sensor unit is defective Replace the sensor unit Error in the can bus pressure The analog values of the Replace the sensor unit E63 sensor unit are invalid transducer sensor unit Error in the can bus data See E62 See E62 E64 transfer of the length/angle sensor unit Error in the can bus See E63 See E63 E65 length/angle sensor unit Error in the data of the digtal PDB variable invalid Change system software E66 Change MENTOR I/O MENTOR Error in the can bus data PDB variable invalid Connect digtal I/O external CAN E67 transfer of the digtal I/O module external module The selected rigging condition Select another rigging condition is not contained in the crane E84 Wrong rigging condition. data file. Check the programming in the crane data file. The computed radius is too Check the programming in the Error in the radius E85 small (negative deflection) crane data file. determination The operating mode on the Select operating mode without Operating mode switchover with E89 console has been switched load on the boom load. over with the boom loaded. LMI processing time limit Reset system E98 LMI watchdog activated exceeded Connect PC terminal and watch error messages Short circuit in the A2B switch Replace A2B switch Short circuit in the A2B switch EAB circuit Short circuit in the cable to (not with radio A2B) the A2B switch Replace cable to the A2B switch
56 50 650 69 0101E_REV A (GROVE RT-TM).DOC / Rev. A / 2007-08-17 / rk.