Vibration Absorbers: Scan This QR Code

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

VIBRATION ABSORBERS

Scan this QR Code

HOT
WATER
16 DN5000 +550°C
OIL

Besides of compensating thermal expansions,metal bellowed expansion joints can provide proper solutions for the prob-
lems caused by the system vibration. Goval vibration absorbers can resolve any problems related to mechanical
. vibration and have a higher pressure and temperature capacity than rubber bellows

Movement Absorption
Goval standard Vibration absorbers are finished with double ply bellows with several thin layers of stainless steel (AISI
321). This delivers maximum performance regarding, high pressure and temperature capacity, noise and vibration
absorption and overall cyclic service life. Unlike rubber expansion joints, stainless steel bellows are not effected by
. atmospheric dam-age and UV-radiation especially when used in an outdoor installation

Advantages of Double Double Plied Vibration Absorbers


• The vibration absorbers can withstand high pressure at elevated temperatures
• Reduces vibrations, oscillations, and noise (sound and vibration) from pumps into pipe systems
• The tie rods are used for pressure thrust forces from the pump are not transferred to the piping
• They have a compact design that reduces the waste of space.
• Performance reliability and increased service life of the pipe system and connected equipment
• Unlike rubber expansion joints, the vibration absorbers are resistant against ageing, high temperatures and UV-radiation

Application Areas
• All piping systems and where vibrations and stresses occur
• Equipment like pumps, compressors, engines,burners etc..
• Heating, climate, ventilation and heat recovery installations
• Gas, water and sewage treatment plants

DESIGN (EN 14917&EJMA)


Bellow Material Stainless Steel AISI 321 (Opt.304,316L,316TI,309)
Connection Types Fixed and Floating Flanged, Welded Ended & Grooved
Flange Material PN 16, St.37.2 as standard, the material can be customised on request
Inner Sleeve Available in stainless steel AISI 321 (Opt. 304,316L,316TI,309) on request
Accessories Inner sleeve, cover, counter flange, gaskets, insulation etc. are available on request.
Certificates Material certificate 3.1 according to EN 10204 and /or ASME
PED 2014/68/EU Cat.III Mod.H

Operation Conditions
Operating Temperature -10°C/+550°C
Operating Pressure Standard pressure rating is PN16
Can be produced with different pressure rates PN 2,5-63
PN corresponds to the allowable operating pressure at room temperature

Important
We strongly advise against the use of expansion joints and bellows for misalignment.
Torsion on bellow parts are not desirable and should be eliminated.
40
VIBRATION ABSORBERS

Double Plied Vibration Absorber with rotating flanges


Available Pressure
Type Movement
Sizes (DN) Class (PN)
MKTY-30 30 mm (-20/+10) 25-5000 16

Bellow Information MKTY-30 Flange (DIN EN 1092/1) PN 16


Effective Bellow Axial Spring DN ØD Øk Ød4 f b Ødxn
DN Ødi Ødo Area Rate L Code
DN25 115 85 68 2 16 Ø 14x4
cm2 N/mm
DN32 140 100 78 2 18 Ø 18x4
DN25 38 48,2 14,58 82,1 110 702.031.103.102
DN40 150 110 88 3 18 Ø 18x4
DN32 42,4 55 18,62 49,7 115 702.031.103.104
DN50 165 125 102 3 20 Ø 18x4
DN40 48,3 61 23,44 60,8 120 702.031.103.106
DN65 185 145 122 3 20 Ø 18x4
DN50 60,3 76 36,46 104,5 110 702.031.103.108
DN80 200 160 138 3 20 Ø 18x8
DN65 76,1 95 57,45 87,8 110 702.031.103.110
DN100 220 180 158 3 22 Ø 18x8
DN80 88,9 111 78,42 178,9 110 702.031.103.112
DN125 250 210 188 3 22 Ø 18x8
DN100 114,3 140 137,09 252,2 115 702.031.103.114
DN150 285 240 212 3 24 Ø 23x8
DN125 139,7 164 181,01 320,0 130 702.031.103.116
DN200 340 295 268 3 26 Ø 23x12
DN150 168,3 200 266,20 196,4 145 702.031.103.118
DN250 405 355 320 3 29 Ø 27x12
DN200 219,1 250 431,86 694,2 140 702.031.103.120
DN300 460 410 378 4 32 Ø 27x12
DN250 273 323 697,11 590,0 150 702.031.103.122
DN300 323,9 380 972,37 496,8 150 702.031.103.124 Alternative flange dimensions are also possible e.g. according
to US standards (ANSI), JIS etc.
*All dimensions given in the tables are in “mm”.
** Subject to technical alterations and deviations resulting from production process without giving any notification.

Reduction Factors for Pressure


Pressure reduction factor
Temperature Reduction Temperature Reduction
°C Factor Kp °C Factor Kp
The reduction factor is used to define the
20 1,00 350 0,64 design pressure [PS] where temperatures
100 0,85 400 0,63 exceed 20 °C. It compensates for the decay
in material mechanical properties at elevated
150 0,81 450 0,62
temperatures. The calculated pressure is lower
200 0,77 500 0,60 than the nominal pressure of the standard item.
250 0,71 550 0,59
300 0,68 600 0,57
Calculation: PS ≤ PN x Kp

41
VIBRATION ABSORBERS

Installation Example for Vibration Absorbers

Rising Stem Gate


Valve
Pump

Flow direction
Strainer Checkvalve
Water Tank

Flow
direction

MKTY-30

MKTY-30
Vibration Absorber Expansion Joint

44
VIBRATION ABSORBERS

Braided Expansion Joints


Fixed point

Flow direction
Three Partial
Ball Valve

Checkvalve

Braided Expansion Joints

Three Partial
Ball Valve Flow Direction

Fixed Point

Pump Strainer
(To be fixed)

Braided Expansion Joints


Example for braided expansion joint installation between two tanks

Butterfly
Valve

Braided
Flow Direction Flow Direction
Expansion
Joint

45

You might also like