APPLICATIONS BENEFITS
1 Plastics and synthetics 1 Airtight sealed device.
1 Chemicals and fertilizer 1 Outdoor and strenuous environment application
1 Pharmaceuticals 1 Stable and reliable performance.
1 Food and beverage, 1 Lightweight and easy to install
1 Agriculture and fodder mills/depots 1 Practically designed to allow maintenance, checks
1 Cement as well as ceramics and replacement
1 Power plants 1 Not necessary to remove the complete set from
1 Various incinerators the tank.
STRUCTURE
SHAFT
OIL-SEAL
FLANGE CLUTCH MOTOR
BADY
PADDLE BODY
MICRO
SWITCH
SHAFT COVER
OIL-SEAL BEARING
PADDLE CLUTCH
NUT
CABLE MOTOR
BEARING MICRO SWITCH
CABLE
PCB SPRING
LED
BODY
PADDLE
LED COVER
OIL-SEAL HOUSING
BEARING MOTOR
MINI TYPE SE3
1
WORKING PRINCIPLE & TORQUE ADJUSTING
CONTROL SWITCH
WORKING PRINCIPLE WHITE
M
1. A synchronous turning motor indicates the
Limit
tank or container’s material isn't obstructing BLACK
the paddles,C & L [COM & NC] are connected. SW.
NO.1
2. When the material is obstructing the paddles, BLUE L
C&L [COM & NC] are disconnected, C&H
[COM & NO] are connected and the motor's YELLOW C Limit
current is cut off. SW.
NO.2
3. When the material drops away from the RED H
paddles and the motor starts again C & L
[COM & NC] connect and the cycle has begun
once again.
TORQUE ADJUSTING MECHANISM
AND WIRING 1 Do not tamper with the spring as it may cause
The torque spring is applied to adjust the shaft the Rotary Paddle to malfunction.
output torque. Default settings aret "weak" and
can be adjusted to the customer’s target based Spring adjusting hole
on the tank contents and S.G. (special gravity) weakest
of the material. weak
Higher S.G. materials require stronger torque weakest
strong
settings. Start with high settings and slowly weak
strong
release the torque force until the appropriate strongest strongest
setting is found.
Resetting torque
adjusting spring
strongest
strong
weak SE29
weakest
SE38
110Vac NC NO
or 24Vac
COM
220Vac 110Vac
220Vac NC COM NO
Available: SE110, 120, 130, 140, 160, 170 240Vac
20 ~ 55 Vdc
V+ V- NO COM NC V+ V-
24Vdc
SEA-110D-B
PA2 080104 CC
NC COM NO
20~55 NO NC
Vdc COM DC type
GND
Available:SE110E Available:SE3
2
STANDARD TYPE
SCREW TYPE
SE110 Series
Horizontal mounting SE110 Series SE111 Series
Operation Temperature (-20BC ~ 70BC)
Weight: 1.2 kg
4-f15
1"PF
PCD130 f155
4
SHAFT LENGTH 4-f15 f9
PCD130
ADJUSTABLE TYPE
f27.2
SE130 Series 4-f15
f10 L L
Vertical mounting f12.7
Operation Temperature (-20BC ~ 70BC)
Standard Length: 80
L– 460~630mm (2.5 kg) f8
L– 650~1000mm (2.8 kg)
65
L– 760~1200mm (3.0 kg) 30
3
STANDARD TYPE
HI-TEMP TYPE
SE140 Series SE140 Series SE141 Series
Horizontal mounting
Temp. (-20BC ~ 200BC) f98
Weight: 2.1 kg
f98
1/2"PF
1/2"PF
HI-TEMP TYPE
PROTECTIVE TUBE TYPE 210
SE141 Series 189
Horizontal /Vertical mounting
f155
Operation Temperature (-20BC ~ 200BC)
f155
Standard Length (option): 4 PCD130
L--250mm (2.6 kg) 4
L--500mm (2.9 kg) PCD130
f10 f27.2
L--750mm (3.2 kg) 92
4-f15
f10 L
Special length is made by order
30
4-f15
100 80
65
HI-TEMP SHAFT
LENGTH ADJUSTABLE TYPE SE146 Series SE160 Series
SE146 Series
Vertical mounting
Operation Temperature (-20BC ~ 200BC) f98
Standard Length (option):
f98
L– 450~630mm (3 kg)
L– 650~1000mm (3.3 kg) 1/2"PF
L– 760~1200mm (3.5 kg)
1/2"PF 135
Special length is made by order
189
f155
f8
30 30
100 100
4
MODEL NUMBER / ORDER CODE COMPARISON TABLE
5
ORDER INFORMATION
05 06 10 11 12 13 14 15 16 17 18 19 20 21 22
SEX1 99 0 0 - A 9999999999999
05 06 Model
00: Standard
02: Hi-temperature
10 Construction
A: Ceneral type
B: Shafe protective tube type
C: Shafe length adjustable type
D: Cable wire type
11 Power supply
A: AC110V D: AC24V
B: AC220V E: DC24V
C: AC240V
Connection
12 13 14 15 16 17
18 Paddle model
A: None
B: 100x30(WxH)
C: 65x80(WxH)
F: 50x30(WxH)
G: Scimitar type132x100(WxH)
H:Folding type 200x28(WxH)
19 20 21 22 Length
Code Length range
0001~4000 0001~4000mm
6
NEPSI PROOF No.GYB16.1948X Ex d IIC T3~T6 Gb
Ex tD A20/A21 IP65
T80BC/T95BC/T130BC/T190BC
PTB PROOF No. 05 ATEX 1029 II 2G Ex d IIB T6~T3 Gb
II 2D Ex tb IIIC T85BC~T200BC
EXPLOSION PROOF TYPE Db IP65
1 Power source : (A)110Vac, (B)220Vac, (C)240Vac 1 Connect : 1"PF screw or flange 1"~6"
(D)24Vac, 50/60Hz 2-1/2"H5kg/cm2 (std.)
1 Power consumption :3W 1 Housing material : AL Alloy, ADC-12
1 Contact capacity : SPDT, 3A/250Vac 1 Conduit : 1/2" (std.) or 3/4"NPT
1 Rotary speed : 1 R.P.M. 1 Material density : 0.5 g/cm3
1 Insulation test voltage : AC 1500VH1minute
f155 20
14
f10 4- f15
PCD 130
75
30
100
100
30
100
7
NEPSI PROOF No.GYB16.1948X Ex d IIC T3~T6 Gb
Ex tD A20/A21 IP65
T80BC/T95BC/T130BC/T190BC
PTB PROOF No. 05 ATEX 1029 II 2G Ex d IIB T6~T3 Gb
II 2D Ex tb IIIC T85BC~T200BC
EXPLOSION PROOF TYPE Db IP65
f113
f113 f113
108
108 108
f90
f90
45 f155 20
45
f155 14
14
1"PF f14
f27.2
PCD 130
f6 4-f15
f10 f9 PCD 130
L=250~ L=450~
f14 4-f15
750 mm L=450~ 4000 mm
1200 mm f12.7 f28 108
30
30 100
100
4 Paddle Introduction
A E
(E) 50x30 (WxH), Suitable for high
(A) 100x30 (WxH), Min. fixed hole
diameter size f90mm. S.G. raw materials. Use a
small size paddle to decrease
W W the impact of material falling
directly on paddle.
H
H
F
B,C,D (F) Scimitar model paddle, Screw
(B) 65x80 (WxH), Directly mounted 132 tightly on the 1" diameter
into 2" fixed hole. fixed hole, It Is easier to
W (C) 65x120 (WxH), Directly mounted mount and dismount.
into 2" fixed hole. 100
(D) 80x80 (WxH)
H
30
8
MODEL NUMBER / ORDER CODE COMPARISON TABLE
9
ORDER INFORMATION
05 06 07 08 10 11 12 13 14 15 16 17 18 19 20 21 22
05 06 Model
00: Standard
02: Hi-temperation
07 08 Certification
1C: ATEX-Exd
5C: TS-Exd
7C:NEPSI-Exd
10 Construction
A: Ceneral type
B: Shafe protective tube type
C: Shafe length adjustable type
D: Cable wire type
11 Power supply
A: AC110V
B: AC220V
C: AC240V
D: AC24V
Connection
12 13 14 15 16 17
18 Paddle model
A:None F:50x30(WxH)
B: 100x30(WxH) G:Scimitar type 132x100(WxH)
C:65x80(WxH)
19 20 21 22 Length
Code Length range
0001~4000 0001~4000mm
10
Housing cover code:
0: Aluminum cover
MINI TYPE(ALUMINUM ALLOY COVER) 1: Aluminum cover with LED lamp
177
30 L=86mm
30 18 f88
38 LED indicator
LED indicator
80 8
f79
100
f79
3/4"PF
3/4"PF
1/2"PF
1/2"PF
f8 cable 300mm f8 cable 300mm
L=150~400mm
L=150~400mm
30
LED indicator 30 18 LED indicator
f88
21.7
100
f79 100
21.7 3/4"PF f79
3/4"PF
1/2"PF
f8 cable 300mm 1/2"PF
f8 cable 300mm
11
NEPSI PROOF No.GYJ14.1148
MINI TYPE(EXPLOSION PROOF) DIP A20/21 TA , T3~T6 IP65
177
30 L=86mm
30 18 f88
38
80 8
f79
100
f79
3/4"PF
1/2"NPT 3/4"PF
1/2"NPT
f8 cable 300mm
f8 cable 300mm
L=150~400mm
L=150~400mm
30
30 18
f88
21.7
100
f79 100
21.7 3/4"PF f79
1/2"NPT 3/4"PF
1/2"NPT
f8 cable 300mm
f8 cable 300mm
12
MINI TYPE(PLASTIC COVER)
177
30 L=86mm
30 18 f88
38
80 8
f79
100
f79
3/4"PF
3/4"PF
1/2"PF
1/2"PF
f8 cable 300mm f8 cable 300mm
L=150~400mm
L=150~400mm
30
30 18
f88
21.7
100
f79 100
21.7 3/4"PF f79
3/4"PF
1/2"PF
f8 cable 300mm 1/2"PF
f8 cable 300mm
13
MODEL NUMBER / ORDER CODE COMPARISON TABLE
14
ORDER INFORMATION
05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
05 06 Model
00: Standard
02: Hi-temperation
07 08 Certification
00: None
7D: NEPSI-Exd
10 Construction
A: Ceneral type
B: Shafe protective tube type
11 Power supply
A: AC110V
B: AC220V
C: AC240V
D: AC24V
E: DC24V
Connection
12 13 14 15 16 17
15
ORDER INFORMATION
05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
18 Paddle model
A:None
G: PC; Cross type
H: PC; Scimitar type 120x98(WxH)
I : SUS; 200x28(WxH)
K:SUS; Folding type 80x20(WxH)
19 20 21 22 Length
Code Length range
0001~400 0001~400mm
16
MINI TYPE(ECONOMY)
STANDARD
SE290 A/B/D
Operation temperature: -20BC ~ 70BC
Paddle material: PC
179
30 41
f70
3/4"PF
17
MODEL NUMBER / ORDER CODE COMPARISON TABLE
SE290A SEX40000-CAA
SE290B SEX40000-CAB
SE290C SEX40000-CAC
SE290D SEX40000-CAD
18
ORDER INFORMATION
11 12 13 14 15 16 17 18 19 20 21 22
SEX4 0 0 0 0 - C A 999999999999
11 Power supply
A: AC110V
B: AC220V
D: AC24V
Connection
12 13 14 15 16 17
18 Paddle model
A:None
G:PC; Cross type
H:PC; Scimitar type 120x98(WxH)
I :SUS; 100x30(WxH)
K:SUS; Folding type 80x20(WxH)
19
MOUNTING EXAMPLES
Min.3/4"PF 30
Max.45
Max.15mm
20
EXAMPLES
SE130
SE141
SE110
SE120
15B
SE111
INSTALLATION NOTICES
1. Side mount the sensor at a downward angle of 15° ~20° to decrease the material inflow impact.
2. For high temperature application (more than 70°C), please use the SE149 Series.
3. For SE110~SE140 using a 1" inlet, please apply the scimitar model and screw directly.
4. For SE130, SE146 series have flexible and extendible shafts.
5. Please ensure the lead wire enters the housing from the bottom and the nuts are fastened to secure the device.
21
Global Network
Germany
China
U.S.
Taiwan U.S.
Singapore
Malaysia
Indonesia
Singapore
FineTek Pte Ltd. - Singapore Office
No. 60 Kaki Bukit Place, #07-06 Eunos
Techpark 2 Lobby B, Singapore 415979
TEL: 65-6452-6340
EMAIL: [email protected]
Indonesia
FineTek Co., Ltd. - Indonesia Office
Ruko Golden 8 Blok H No.38
Gading Serpong, Tangerang, Indonesia
TEL: 62 (021)-2923-1688
EMAIL: [email protected]
Distributor:
Malaysia
FineTek Co., Ltd. - Malaysia Office
8-05, Plaza Azalea, Persiaran Bandaraya,
Seksyen 14, 40000 Shah Alam, Selangor, Malaysiac
TEL: 603-5524-7168
EMAIL: [email protected]
08-SEXEP-102317