Schedulequantity
Schedulequantity
Schedulequantity
Page 1 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
3.1.1 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural
sources : 8 graded stone aggregate 40 mm nominal size derived
from natural sources). 45 cum 5789.60 260532.00
3.2 Providing and laying cement concrete in retaining walls, return
walls, walls (any thickness) including attached pilasters, columns,
piers, abutments, pillars, posts, struts, buttresses, string or lacing
courses, parapets, coping, bed blocks, anchor blocks, plain
window sills, fillets, sunken floor etc., up to floor five level,
excluding the cost of centering, shuttering and finishing :
4.1.1 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural
sources: 3 graded stone aggregate 20 mm nominal size derived
from natural sources). 12 cum 7718.25 92619.00
4.2 Reinforced cement concrete work in walls (any thickness),
including attached pilasters, buttresses, plinth and string
courses, fillets, columns, pillars, piers, abutments, posts and struts
etc. above plinth level up to floor five level, excluding cost of
centering, shuttering, finishing and reinforcement
4.2.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived
from natural sources). 28 cum 9306.00 260568.00
4.3 Centering and shuttering including strutting, propping etc. and
removal of form for
4.3.1 Foundations, footings, bases of columns, etc. for mass concrete
12 sqm 284.85 3418.00
4.3.2 Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc. 305 sqm 609.30 185837.00
4.3.3 Suspended floors, roofs, landings, balconies and access platform
2760 sqm 693.05 1912818.00
4.3.4 Shelves (Cast in situ) 20 sqm 693.05 13861.00
4.3.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
2200 sqm 552.05 1214510.00
4.3.6 Columns, Pillars, Piers, Abutments, Posts and Struts 1595 sqm 733.70 1170252.00
4.3.7 Stairs, (excluding landings) except spiral-staircases 170 sqm 622.35 105800.00
4.3.8 Small lintels not exceeding 1.5 m clear span, moulding as in
cornices, window sills, string courses, bands, copings, bed plates,
anchor blocks and the like 60 sqm 284.85 17091.00
4.3.9 Small surfaces such as cantilever ends, brackets and ends of steps,
caps and bases to pilasters and columns and the like
280 sqm 773.70 216636.00
4.4 Extra for additional height in centering, shuttering where ever
4.4.1 Suspended floors, roofs, landing, beams and balconies (Plan area
to be measured) 2500 sqm 287.50 718750.00
Page 2 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
4.5 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete upto
plinth level.
4.5.1 Thermo-Mechanically Treated bars of grade Fe-500D or more.
3500 kg 83.50 292250.00
4.6 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
above plinth level.
4.6.1 Thermo-Mechanically Treated bars of grade Fe-500D or more.
143817 kg 83.50 12008720.00
4.7 Add for plaster drip course/ groove in plastered surface or
moulding to R.C.C. projections. 825 metre 58.90 48593.00
4.8 Providing and laying in position machine batched and machine
mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using coarse aggregate as well as fine
aggregate derived from natural sources and cement content as
per approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering, finishing
and reinforcement, including admixtures in recommended
proportions as per IS: 9103 to accelerate, retard setting of
concrete, improve workability without impairing strength and
durability as per direction of Engineer-in-charge. (Note:- Cement
content considered in this item is @ 330 kg/cum."Excess/ less
cement used as per design mix is payable/recoverable
separately).
4.10.1 All works above plinth level upto floor V level 969 cum 9802.20 9498332.00
4.11 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each
four floors or part thereof. 1181 cum 280.95 331802.00
4.12 Extra for centering & shuttering including strutting, proping etc
and removal of form for mullion for all height instead of shuttering
& centering in column. 110 Sqm 637.70 70147.00
Sub-Total 29945820.00
5 MASONRY WORK
Page 3 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
5.1 Brick work with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in foundation and plinth in:
5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) 42.5 cum 6157.45 261692.00
5.2 Brick work with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in superstructure above plinth level up to
floor V level in all shapes and sizes in :
5.2.1 Cement mortar 1:6 (1 cement : 6 coarse sand) 610 cum 7590.45 4630175.00
5.3 Extra for brick work / AAC block masonry / Tile brick masonry in 660 cum 236.65 156189.00
5.4 superstructure
Half above
brick masonry floor
with V level, burnt
common for each four
clay floors
F.P.S. or modular)
(non part
bricks of class designation 7.5 in superstructure above plinth level
up to floor V level.
5.4.1 Cement mortar 1:4 (1 cement :4 coarse sand) 587 sqm 932.10 547143.00
5.5 Extra for half brick masonry in superstructure, above floor V level
for every four floors or part thereof by mechanical means.
587 sqm 20.95 12298.00
5.6 Extra for providing and placing in position 2 Nos 6mm dia. M.S.
bars at every third course of half brick masonry. 543 sqm 80.10 43494.00
Sub-Total 5650991.00
6 CLADDING WORK
6.1 Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms,
vanity counters, window sills, facias and similar locations of
required size, approved shade, colour and texture laid over 20 mm
thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints
treated with white cement, mixed with matching pigment, epoxy
touch ups, including rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at all levels.
Page 4 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
6.6 Providing and fixing stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in
urinal partitions by cutting a chase of appropriate width with
chase cutter and embedding the stone in the chase with epoxy
grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 6 mm nominal size) as per direction of
Engineer-in-charge and finished smooth.
Page 5 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
6.1 Designing, fabricating, testing, installing and fixing in position
Curtain Wall with Aluminium Composite Panel Cladding, with open
grooves for linear as well as curvilinear portions of the building ,
for all heights and all levels etc. including: (a) Structural analysis &
design and preparation of shop drawings for pressure equalisation
or rain screen principle as required, proper drainage of water to
make it watertight including checking of all the structural and
functional design. (b) Providing, fabricating and supplying and
fixing panels of aluminium composite panel cladding in pan shape
in metalic colour of approved shades made out of 4mm thick
aluminium composite panel material consisting of 3mm thick FR
grade mineral core sandwiched between two Aluminium sheets
(each 0.5mm thick). The aluminium composite panel cladding
sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon
based fluoropolymer resin coating of approved colour and shade
on face # 1 and polymer (Service) coating on face # 2 as specified
using stainless steel screws, nuts, bolts, washers, cleats, weather
silicone sealant, backer rods etc. (c) The fastening brackets of
Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the wind load
movement, fasteners, SS 316 Pins and anchor bolts of approved
make in SS 316, Nylon separators to prevent bi-metallic contacts
all complete required to perform as per specification and drawing
The item includes cost of all material & labour component, the
cost of all mock ups at site, cost of all samples of the individual
components for testing in an approved laboratory, field tests on
the assembled working curtain wall with aluminium composite 50 sqm 4309.80 215490.00
panel cladding, cleaning and protection of the curtain wall with
Sub-Total 3517885.00
7 WOOD AND PVC WORK
7.1 Providing and fixing ISI marked flush door shutters conforming to
IS : 2202 (Part I) non-decorative type, core of block board
construction with frame of 1st class hard wood and well matched
commercial 3 ply veneering with vertical grains or cross bands and
face veneers on both faces of shutters:
7.1.1 35 mm thick including ISI marked Stainless Steel butt hinges with
necessary screws 85 sqm 1886.70 160370.00
7.2 Extra for providing lipping with 2nd class teak wood battens 25
mm minimum depth on all edges of flush door shutters (over all
area of door shutter to be measured).
85 sqm 401.40 34119.00
7.3 Extra for providing vision panel not exceeding 0.1 sqm in all type
of flush doors (cost of glass excluded) (overall area of door shutter
to be measured):
7.3.1 Rectangular or square 25 sqm 173.95 4349.00
7.4 Extra for cutting rebate in flush door shutters (Total area of the
shutter to be measured). 10 sqm 93.65 937.00
7.5 Providing and fixing ISI marked oxidised M.S. sliding door bolts
with nuts and screws etc. complete :
7.5.1 250x16 mm 3 each 170.00 510.00
7.6 Providing and fixing ISI marked oxidised M.S. handles conforming
to IS:4992 with necessary screws etc. complete :
Page 6 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
7.7 Providing and fixing aluminium die cast body tubular type
universal hydraulic door closer (having brand logo with ISI, IS :
3564, embossed on the body, door weight upto 35 kg and door
width upto 700 mm), with necessary accessories and screws etc.
complete. 95 each 1003.50 95333.00
7.8 Providing and fixing bright finished brass 100 mm mortice latch
and lock, ISI marked, with six levers and a pair of anodised (anodic
coating not less than grade AC 10 as per IS : 1868) aluminium lever
handles of approved quality with necessary screws etc. complete.
32 each 748.65 23957.00
7.9 Providing and fixing partition upto ceiling height consisting of G.I.
frame and required board, including providing and fixing of frame
work made of special section power pressed/ roll form G.I. sheet
with zinc coating of 120 gms/sqm(both side inclusive), consisting
of floor and ceiling channel 50mm wide having equal flanges of 32
mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing
of 610 mm centre to centre with dash fastener of 12.5 mm dia
meter 50 mm length or suitable anchor fastener or metal screws
with nylon plugs and the studs 48 mm wide having one flange of
34 mm and other flange 36 mm and 0.50 mm thick fixed vertically
within flanges of floor and ceiling channel and placed at a spacing
of 610 mm centre to centre by 6 mm dia bolts and nuts, including
fixing of studs along both ends of partition fixed flush to wall with
suitable anchor fastener or metal screws with nylon plugs at
spacing of 450 mm centre to centre, and fixing of boards to both
side of frame work by 25 mm long dry wall screws on studs, floor
and ceiling channels at the spacing of 300 mm centre to centre.
The boards are to be fixed to the frame work with joints staggered
to avoid through cracks, M.S. fixing channel of 99 mm width (0.9
mm thick having two flanges of 9.5 mm each) to be provided at
the horizontal joints of two boards, fixed to the studs using metal
to metal flat head screws, including jointing and finishing to a flush
finish with recommended jointing compound, jointing tape, angle
beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and
two coats of primer suitable for board as per manufacture's
specification and direction of engineer in charge all complete.
Page 7 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
7.11 Providing and fixing fire resistant door frame of section 143 x 57
mm having built in rebate made out of 16 SWG G.I. sheet (zinc
coating not less than 120 gm/sqm) duly filled with vermuculite
based concrete mix, suitable for mounting 60 minutes fire rated
door shutters. The frame is fitted with intumuscent fire seal strip
of size 10x4 mm (minimum) alround the frame and fixing with
dash fastener of approved size and make, including applying a coat
of approved brand fire resistant primer etc. complete as per
direction of Engineer-in-charge (Dash fastener to be paid for
separately).
25 metre 1444.30 36108.00
7.12 Providing and fixing 50 mm thick glazed fire resistant door shutters
of 60 minutes fire rating conforming to IS:3614 (Part-II), tested
and certified as per laboratory approved by Engineer-in-charge,
with suitable mounting on door frame, consisting of vertical styles,
lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made
out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2)
duly filled FR insulation material and fixing with necessary stainless
steel ball bearing hinges of approved make, including applying a
coat of approved fire resistant primer etc. all complete as per
direction of Engineer-in-charge (panneling to be paid for
separately).
15 sqm 6166.00 92490.00
7.13 Providing and fixing plain lining with necessary screws/nuts &
bolts/ nails, including a coat of approved primer on one face, and
fixed on wooden /steel frame work, complete as per direction of
Engineer-in- charge (Frame work shall be paid for separately).
Page 8 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
7.19 Providing and fixing SS indicator bolt with necessary screws etc.
complete. 16 Each 793.25 12692.00
7.2 Extra for Providing & fixing Ebco make aluminium handle for
windows etc. powder coated in brown colour with necessary
stainless steel screws etc. to the side hung windows as per
directions of the Engineer-in-charge complete instead of
aluminium window fastner. 120 Each 14.27 1712.00
7.21 Providing and fixing SS floor door silencer with necessary screws
etc. complete. 30 Each 120.69 3621.00
7.22 Extra for Providing and fixing mirror polished 18 mm Granite for
wall lining (veneer work) , in required design and pattern wherever
required, stones of different finished surface texture, on 12 mm
(average) thick cement mortar 1:3 (1 cement : 3 oarse sand) laid
and jointed with white cement slurry @ 3.3 kg/sqm including
pointing with white cement slurry admixed with pigment of
matching shade, including rubbing, curing, polishing etc. all
complete above 1.20 meter height up to 3.50 meter instead of
skirting ,dado and pillars.hanger etc.
175 Sqm 393.90 68933.00
Sub-Total 1037419.00
8 STEEL WORK
8.1 Providing and fixing 1mm thick M.S. sheet door with frame of
40x40x6 mm angle iron and 3 mm M.S. gusset plates at the
junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer.
8.1.1 Using M.S. angels 40x40x6 mm for diagonal braces 12.7 sqm 4428.15 56238.00
8.2 Providing and fixing T-iron frames for doors, windows and
ventilators of mild steel Tee-sections, joints mitred and welded,
including fixing of necessary butt hinges and screws and applying a
priming coat of approved steel primer.
8.2.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement
concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse
sand : 6 graded stone aggregate 20 mm nominal size).
125 kg 106.45 13306.00
8.3 Steel work welded in built up sections/ framed work, including
cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required.
Page 9 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
8.6 Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of required
size, on the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in-charge, (for payment
purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts,
fasteners etc.).
600 kg 575.45 345270.00
Sub-Total 670383.00
9 FLOORING
9.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate) finished with a floating coat of neat
cement, including cement slurry, but excluding the cost of nosing
of steps etc. complete.
9.1.1 40 mm thick with 20 mm nominal size stone aggregate 37 sqm 498.35 18439.00
9.2 Cement plaster skirting up to 30 cm height, with cement mortar
1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat
cement.
9.2.1 18 mm thick 2 sqm 521.15 1042.00
9.3 Extra for pre finished nosing to treads of steps of marble stone.
190 metre 530.25 100748.00
9.4 Extra for marble stone flooring in treads of steps and risers using
single length up to 2.00 metre. 130 sqm 622.75 80958.00
9.5 Kota stone slab flooring over 20 mm (average) thick base laid over
and jointed with grey cement slurry mixed with pigment to match
the shade of the slab, including rubbing and polishing complete
with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Page 10 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
9.1 Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less
than 0.08% and conforming to IS: 15622, of approved make, in all
colours and shades, laid on 20mm thick cement mortar 1:4 (1
cement : 4 coarse sand), jointing with grey cement slurry @ 3.3
kg/ sqm including grouting the joints with white cement and
matching pigments etc., complete.
9.13.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat
Eye or equivalent. 200 sqm 3526.60 705320.00
9.14 "Extra for making steps of stairs antiskid by making band of 3 Nos.
grooves, 3 mm wide along the length of stone by stone cutting
machine including grinding and polishing etc. complete (Length of
band to measured for payment in running meter).
280 RM 159.00 44520.00
Kota Stone"
9.15 Providing & fixing machine-cut & machined polished 25 mm thick
Kota Stone Stone in treads of steps, sill, copings,parapet top,
window sill, planter top and such other locations, laid on 20 mm
(average) thick cement mortar 1:4 (1cement:4coarse sand) and
jointed with grey cement slurry mixed with pigment to match the
shades of the slabs, including rubbing and polishing complete.The
Stone used should be in one single piece of minimum 900 mm
long & above and width as per rquirement etc. complete, all as
per drawing and direction of Engineer-in-charge.
Page 11 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
10.1 Providing corrugated G.S. sheet roofing including vertical / curved
surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G.I.
limpet washers filled with white lead, including a coat of approved
steel primer and two coats of approved paint on overlapping of
sheets complete (up to any pitch in horizontal/ vertical or curved
surfaces), excluding the cost of purlins, rafters and trusses and
including cutting to size and shape wherever required.
10.1.1 0.63 mm thick with zinc coating not less than 275 gm/ m² 22 sqm 915.00 20130.00
10.2 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 stone aggregate 10 mm and down gauge),
including finishing with cement mortar 1:3 (1 cement : 3 fine sand)
as per standard design :
10.2.1 In 75x75 mm deep chase 225 metre 237.25 53381.00
10.3 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1
m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
12 each 244.05 2929.00
10.4 Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal
ring conforming to IS : 5382, leaving 10 mm gap for thermal
expansion, (i) Single socketed pipes.
10.4.1 110 mm diameter 100 metre 305.05 30505.00
10.5 Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
10.5.1 Coupler
10.5.1.1 110 mm 24 each 117.80 2827.00
10.5.2 Bend 87.5°
10.5.2.1 110 mm bend 12 each 129.85 1558.00
10.6 Providing and fixing unplasticised -PVC pipe clips of approved
design to unplasticised - PVC rain water pipes by means of
50x50x50 mm hard wood plugs, screwed with M.S. screws of
required length, including cutting brick work and fixing in cement
mortar 1:4 (1 cement : 4 coarse sand) and making good the wall
etc. complete.
10.6.1 110 mm 36 each 288.80 10397.00
Page 12 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
10.7 Providing and fixing false ceiling at all height including providing
and fixing of frame work made of special sections, power pressed
from M.S. sheets and galvanized with zinc coating of 120 gms/sqm
(both side inclusive) as per IS : 277 and consisting of angle cleats of
size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm,
at 1200 mm centre to centre, one flange fixed to the ceiling with
dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other
flange of cleat fixed to the angle hangers of 25x10x0.50 mm of
required length with nuts & bolts of required size and other end of
angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm
running at the spacing of 1200 mm centre to centre, to which the
ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered
flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre
to centre, shall be fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made out of 2.64 mm
dia x 230 mm long G.I. wire at every junction, including fixing
perimeter channels 0.5 mm thick 27 mm high having flanges of 20
mm and 30 mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm centre, with
25mm long dry wall screws @ 230 mm interval, including fixing of
gypsum board to ceiling section and perimeter channel with the
help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of tapered and
square edges of the board with recommended jointing compound
, jointing tapes , finishing with jointing compound in 3 layers
covering upto 150 mm on both sides of joint and two coats of
primer suitable for board, all as per manufacturer's specification
10.7.1 and
12.5also
mmincluding the cost
thick tapered edgeofgypsum
making plain
openings
boardforconforming
light fittings,
to IS:
2095- (Part I) :2011 (Board with BIS certification marks)
580 sqm 1117.65 648237.00
10.8 Providing & fixing UV stabilised fiberglass reinforced plastic sheet
roofing up to any pitch, including fixing with polymer coated 'J' or
'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers
complete but excluding the cost of purlins, rafters, trusses etc. The
sheets shall be manufactured out of 2400 TEX panel rovigs
incorporating minimum 0.3% ultra-violet stabiliser in resin system
under approximately 2400 psi and hot cured. They shall be of
10.8.1 uniform
2 pigmentation
mm thick corrugatedand thickness
(2.5" or 4.2" without
or 6") orairstep-down
pockets and
(2"shall
or 3"
or 6" ) as specified 10 sqm 1095.20 10952.00
Page 13 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
10.9 Providing and fixing tiled false ceiling of specified materials of size
595x595 mm in true horizontal level, suspended on inter locking
metal grid of hot dipped galvanized steel sections ( galvanized @
120 grams/ sqm, both side inclusive) consisting of main "T" runner
with suitably spaced joints to get required length and of size
24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at
1200 mm center to center and cross "T" of size 24x25 mm made of
0.30 mm thick (minimum) sheet, 1200 mm long spaced between
main "T" at 600 mm center to center to form a grid of 1200x600
mm and secondary cross "T" of length 600 mm and size 24x25 mm
made of 0.30 mm thick (minimum) sheet to be interlocked at
middle of the 1200x600 mm panel to form grids of 600x600 mm
and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of
approved texture in the grid including, required cutting/making,
opening for services like diffusers, grills, light fittings, fixtures,
smoke detectors etc. Main "T" runners to be suspended from
ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to
ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI
adjustable rods with galvanised butterfly level clips of size 85 x 30
x 0.8 mm spaced at 1200 mm center to center along main T,
bottom exposed width of 24 mm of all T-sections shall be pre-
painted with polyester paint, all complete for all heights as per
specifications, drawings and as directed by Engineer-in-charge.
10.9.1 12.5 mm thick square edge PVC Laminated Gypsum Tile of size
595x595 mm, made of Gypsum plasterboard, manufactured from
natural gypsum as per IS 2095 part I and laminated with white
0.16mm thick fire retardant PVC film on the face side and
12micron metalized polyester on the back side with all edges
sealed with the face side PVC film which goes around and wraps
the edges and is bonded to the edges and the back side metalized
polyester film so as to make the tile a completely sealed unit.
1745 sqm 1880.95 3282258.00
10.1 Providing and fixing thermal insulation with Resin Bonded Fibre
glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm
thick, wrapped in 200G Virgin Polythene Bags fixed to wall with
screw, rawel plug & washers and held in position by criss crossing
GI wire etc. complete as per directions of Engineer-in-Charge.
95 sqm 316.40 30058.00
10.11 Providing and fixing thermal insulation of ceiling (under deck
insulation) with Resin Bonded Rockwool conforming to IS:
8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin
Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm)
@ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top
most ceiling of building. 700 sqm 546.40 382480.00
Sub-Total 4475712.00
11 FINISHING
11.1 12 mm cement plaster of mix :
11.1.1 1:6 (1 cement: 6 coarse sand) 2450 sqm 263.55 645698.00
11.2 15 mm cement plaster on rough side of single or half brick wall of
mix:
11.2.1 1:6 (1 cement: 6 coarse sand) 5900 sqm 303.90 1793010.00
11.3 12 mm cement plaster finished with a floating coat of neat cement
of mix :
Page 14 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
11.3.1 1:3 (1 cement: 3 fine sand) 380 sqm 340.85 129523.00
11.4 15 mm cement plaster on rough side of single or half brick wall
finished with a floating coat of neat cement of mix :
11.4.1 1:4 (1 cement: 4 fine sand) 86 sqm 369.30 31760.00
11.5 6 mm cement plaster of mix :
11.5.1 1:3 (1 cement : 3 fine sand) 3100 sqm 227.35 704785.00
11.6 Extra for plastering exterior walls of height more than 10 m from
ground level for every additional height of 3 m or part thereof.
2800 sqm 65.95 184660.00
11.7 Extra for plastering:
11.7.1 Flewing soffits 300 sqm 88.35 26505.00
11.8 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine
sand) :
11.8.1 Flush/ Ruled pointing 2800 sqm 285.40 799120.00
11.9 Extra for pointing on walls on the outside at height more than 10
m from ground level for every additional height of 3 m or part
there of. 2965 sqm 7.15 21200.00
11.1 White washing with lime to give an even shade :
11.10.1 New work (three or more coats) 1200 sqm 28.55 34260.00
11.11 Distempering with 1st quality acrylic distemper (ready mixed)
having VOC content less than 50 gms/litre, of approved
manufacturer, of required shade and colour complete, as per
manufacturer's specification.
11.11.1 Two or more coats on new work 6500 sqm 87.15 566475.00
11.12 Finishing walls with textured exterior paint of required shade :
11.12.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over
and including priming coat of exterior primer applied @ 2.20kg/10
sqm 7350 sqm 232.00 1705200.00
11.13 Wall painting with acrylic emulsion paint of approved brand and
manufacture to give an even shade :
11.13.1 Two or more coats on new work 300 sqm 128.65 38595.00
11.14 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :
11.14.1 Two or more coats on new work 210 sqm 121.55 25526.00
11.15 Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete. 10500 sqm 115.15 1209075.00
11.16 Removing dry or oil bound distemper, water proofing cement
paint and the like by scrapping, sand papering and preparing the
surface smooth including necessary repairs to scratches etc.
complete. 1500 sqm 18.25 27375.00
11.17 Providing and fixing approved galvanized chicken wire mesh (24
gauge 12 mm size) to junction of concrete and masonry work and
other locations where called for at all the heights with necessary
scaffolding etc. including cutting to required sizes, side laps of
minimum 75 mm and fixing in position with galvanized wire nails
etc. complete.
300 Sqm 144.58 43374.00
Sub-Total 7986141.00
12 REPAIRS TO BUILDING
Page 15 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
12.1 Making the opening in brick masonry including dismantling in floor
or walls by cutting masonry and making good the damages to
walls, flooring and jambs complete, to match existing surface i/c
disposal of mulba/ rubbish to the nearest municipal dumping
ground, all complete as per direction of Engineer-in-Charge.
Page 16 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
13.11 Dismantling precast concrete or stone slabs in walls, partition
walls etc. including stacking within 50 metres lead :
14.2.1 Cement concrete prepared with batch mixing machine 50 cum 8752.35 437618.00
14.3 Providing and laying at or near ground level factory made kerb
stone of M-25 grade cement concrete in position to the required
line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand), including making joints with or without
grooves (thickness of joints except at sharp curve shall not to more
than 5mm), including making drainage opening wherever required
complete etc. as per direction of Engineer-in-charge (length of
finished kerb edging shall be measured for payment). (Precast C.C.
kerb stone shall be approved by Engineer-in-charge).
Page 17 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
14.4 Providing and erecting 2.00 metre high temporary barricading at
site; each panel of size 2.50mx2.00m made of 40x40x6mm angle
iron or 50x50x3mm hollow MS tube posts/horizontal
members/bracings covered with 1.63mm thick MS sheet. The
sheet shall be fixed with 30x5mm MS flat by suitable
welding/riveting. The panels shall be made so that gap of 50cm
above the ground is available making overall height as 2.5m. MS
channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the
bottom having oval shaped holes of size 50x25mm at both ends
with 50cm long MS angle 40x40x6mm bracing. Suitable
arrangement shall be made to fix the barricading to avoid from
overturning by providing 250mm long expansion fasteners at both
ends. The work shall be executed as per drawing/direction of
Engineer-in-Charge which includes writing and painting,
arrangement for traffic diversion such as traffic signals during
construction at site for day and night, glow lamps, reflective signs,
marking, flags, caution tape as directed by the Engineer-in-Charge.
The barricading provided shall be retained in position at site
continuously i/c shifting of barricading from one location to
another location as many times as required during the execution
of the entire work till its completion. Rate include its maintenance
for damages, painting, all incidentals, labour materials,
equipments and works required to execute the job. The
barricading shall not be removed without prior approval of
Engineer-in-Charge. (Note :- One time payment shall be made for
providing barricading from start of work till completion of work i/c
shifting. The barricading provided shall remain to be the property 200 metre 2566.70 513340.00
of the contractor on completion of the work).
Sub-Total 1026222.00
15 SANITARY INSTALLATIONS
15.1 Providing and fixing white vitreous china flat back half stall urinal
of size 580x380x350 mm with white PVC automatic flushing
cistern, with fittings, standard size C.P. brass flush pipe, spreaders
with unions and clamps (all in C.P. brass) with waste fitting as per
IS : 2556, C.I. trap with outlet grating and other couplings in C.P.
brass, including painting of fittings and cutting and making good
the walls and floors wherever required :
15.1.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
8 each 9360.60 74885.00
15.2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P.
brass pillar taps, 32 mm C.P. brass waste of standard pattern,
including painting of fittings and brackets, cutting and making
good the walls wherever require:
15.2.1 White Vitreous China Wash basin size 630x450 mm with a single
15 mm C.P. brass pillar tap 4 each 2751.30 11005.00
15.3 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as
per IS:13983 with C.I. brackets and stainless steel plug 40 mm,
including painting of fittings and brackets, cutting and making
good the walls wherever required :
15.3.1 Kitchen sink with drain board
15.3.1.1 510x1040 mm bowl depth 250 mm 4 each 5155.95 20624.00
Page 18 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
15.4 Providing and fixing white vitreous china laboratory sink with C.I.
brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste
and 40mm C.P. brass trap with necessary C.P. brass unions
complete, including painting of fittings and brackets, cutting and
making good the wall wherever required :
15.13.1 100x100x100 mm
15.13.1.1 Sand cast iron S&S as per IS - 3989 55 each 667.70 36724.00
15.14 Providing and fixing single unequal junction of required degree
with access door, insertion rubber washer 3 mm thick, bolts and
nuts complete :
15.14.1 100x100x75 mm
15.14.1.1 Sand cast iron S&S as per IS - 3989 4 each 916.55 3666.00
15.15 Providing and fixing terminal guard :
15.15.1 100 mm
15.15.1.1 Sand cast iron S&S as per IS - 3989 13 each 389.40 5062.00
15.16 Providing and fixing collar :
15.16.1 100 mm
15.16.1.1 Sand cast iron S&S as per IS - 3989 128 each 409.45 52410.00
15.17 Providing lead caulked joints to sand cast iron/centrifugally cast
(spun) iron pipes and fittings of diameter :
Page 19 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
15.17.1 100 mm 700 each 481.45 337015.00
15.17.2 75 mm 12 each 407.90 4895.00
15.18 Providing and fixing trap of self cleansing design with screwed
down or hinged grating with or without vent arm complete,
including cost of cutting and making good the walls and floors :
Page 20 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
Sub-Total 1644452.00
16 WATER SUPPLY
16.1 Providing and fixing G.I. pipes complete with G.I. fittings and
clamps, i/c cutting and making good the walls etc. Internal work -
Exposed on wall
16.1.1 15 mm dia nominal bore 65 metre 284.90 18519.00
16.1.2 20 mm dia nominal bore 45 metre 344.10 15485.00
16.1.3 25 mm dia nominal bore 90 metre 438.00 39420.00
16.1.4 32 mm dia nominal bore 110 metre 529.70 58267.00
16.1.5 40 mm dia nominal bore 300 metre 639.60 191880.00
16.1.6 50 mm dia nominal bore 15 metre 786.75 11801.00
16.2 Providing and fixing G.I. Pipes complete with G.I. fittings and
clamps, i/c making good the walls etc. concealed pipe, including
painting with anti corrosive bitumastic paint, cutting chases and
making good the wall :
16.2.1 15 mm dia nominal bore 90 metre 447.60 40284.00
16.2.2 20 mm dia nominal bore 55 metre 494.10 27176.00
16.3 Providing and fixing G.I. pipes complete with G.I. fittings including
trenching and refilling etc. External work
16.3.1 25 mm dia nominal bore 30 metre 364.55 10937.00
16.3.2 32 mm dia nominal bore 30 metre 424.70 12741.00
16.3.3 40 mm dia nominal bore 30 metre 483.15 14495.00
16.4 Making connection of G.I. distribution branch with G.I. main of
following sizes by providing and fixing tee, including cutting and
threading the pipe etc. complete :
16.4.1 25 to 40 mm nominal bore 6 each 673.45 4041.00
16.4.2 50 to 80 mm nominal bore 4 each 1432.75 5731.00
16.5 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) :
16.5.1 25 mm nominal bore 7 each 497.15 3480.00
16.5.2 32 mm nominal bore. 4 each 581.25 2325.00
16.5.3 40 mm nominal bore 5 each 678.40 3392.00
16.5.4 50 mm nominal bore 2 each 869.20 1738.00
16.6 Providing and fixing ball valve (brass) of approved quality, High or
low pressure, with plastic floats complete :
16.6.1 25 mm nominal bore 6 each 394.00 2364.00
16.7 Providing and fixing uplasticised PVC connection pipe with brass
unions :
16.7.1 45 cm length
16.7.1.1 15 mm nominal bore 18 each 83.00 1494.00
16.8 Painting G.I. pipes and fittings with synthetic enamel white paint
with two coats over a ready mixed priming coat, both of approved
quality for new work :
16.8.1 25 mm diameter pipe 75 metre 23.70 1778.00
16.8.2 32 mm diameter pipe 90 metre 28.40 2556.00
16.8.3 40 mm diameter pipe 300 metre 33.40 10020.00
16.9 Providing and fixing G.I. Union in G.I. pipe including cutting and
threading the pipe and making long screws etc. complete (New
work) :
16.9.1 20 mm nominal bore 14 each 261.15 3656.00
16.9.2 25 mm nominal bore 24 each 340.10 8162.00
16.9.3 32 mm nominal bore 10 each 384.25 3843.00
16.9.4 40 mm nominal bore 18 each 452.50 8145.00
16.1 Providing and fixing C.P. brass long body bib cock of approved
quality conforming to IS standards and weighing not less than 690
gms.
16.10.1 15 mm nominal bore 8 each 552.35 4419.00
Page 21 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
16.11 Providing and fixing C.P. brass stop cock (concealed) of standard
design and of approved make conforming to IS:8931.
17.3.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with
frame (light duty) 455x610 mm internal dimensions, total weight
of cover and frame to be not less than 38 kg (weight of cover 23 kg
and weight of frame 15 kg) :
17.3.1.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 2 each 10905.05 21810.00
Page 22 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
17.4 Providing orange colour safety foot rest of minimum 6 mm thick
plastic encapsulated as per IS : 10910, on 12 mm dia steel bar
conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as
165 mm with minimum 112 mm space between protruded legs
having 2 mm tread on top surface by ribbing or chequering besides
necessary and adequate anchoring projections on tail length on
138 mm as per standard drawing and suitable to with stand the
bend test and chemical resistance test as per specifications and
having manufacture's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15 cm
cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) complete as per design.
Page 23 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
18.3 Providing and fixing double action hydraulic floor spring of
approved brand and manufacture conforming to IS : 6315, having
brand logo embossed on the body / plate with double spring
mechanism and door weight upto 125 kg, for doors, including cost
of cutting floors, embedding in floors as required and making good
the same matching to the existing floor finishing and cover plates
with brass pivot and single piece M.S. sheet outer box with slide
plate etc. complete as per the direction of Engineer-in-charge.
Page 24 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
18.11 Extra for Providing and fixing aluminium work for doors, windows
and ventilators for louvers ventilation with extruded built up
appropriate Z sections and other sections of approved make
conforming to IS: 733 and IS: 1285 including necessary filling up
the gaps at junctions, i.e. at top, bottom and sides with required
EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically
wherever required including cleat angle, Aluminium snap beading
for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of
Engineer-in-charge instead of fixed portions :(based on DSR Item
21.1.1.)
325 Kg 90.75 29494.00
18.12 Providing and fixing 10 mm thick clear toughned glass in glazing
partition with aluminium U clip as per manufacturer
recommendation including all hardware all complete as per
drawing and as directed by the architect. 140 Sqm 3072.80 430192.00
Sub-Total 4542407.00
19 WATER PROOFING
19.1 Providing and laying integral cement based treatment for water
proofing on the vertical surface by fixing specified stone slab 22
mm to 25 mm thick with cement slurry mixed with water proofing
compound conforming to IS:2645 in recommended proportions
with a gap of 20 mm (minimum) between stone slabs and the
receiving surfaces and filling the gaps with neat cement slurry
mixed with water proofing compound and finishing the exterior of
stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20
mm thick with neat cement punning mixed with water proofing
compound in recommended proportion complete at all levels and
as directed by Engineer-in-charge :
Page 25 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
19.3 Providing and laying integral cement based water proofing
treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc consisting of following
operations: (a) Applying a slurry coat of neat cement using 2.75
kg/sqm of cement admixed with water proofing compound
conforming to IS. 2645 and approved by Engineer-in-charge over
the RCC slab including adjoining walls upto 300 mm height
including cleaning the surface before treatment. (b) Laying brick
bats with mortar using broken bricks/brick bats 25 mm to 115 mm
size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand)
admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of
cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with
water proofing compound conforming to IS : 2645 and approved
by Engineer-in-charge to required slope and treating similarly the
adjoining walls upto 300 mm height including rounding of
junctions of walls and slabs. (c) After two days of proper curing
applying a second coat of cement slurry using 2.75 kg/ sqm of
cement admixed with water proofing compound conforming to IS :
2645 and approved by Engineer-in-charge. (d) Finishing the surface
with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing compound conforming
to IS : 2645 and approved by Engineer-in-charge including laying
glass fibre cloth of approved quality in top layer of plaster and
finally finishing the surface with trowel with neat cement slurry
and making pattern of 300x300 mm square 3 mm deep. (e) The
whole terrace so finished shall be flooded with water for a
19.3.1 minimum
With averageperiod of two weeks
thickness formm
of 120 curing
andand for final test.“All
minimum thickness at
khurra as 65 mm. 715 sqm 1398.50 999928.00
19.4 Grading roof for water proofing treatment with
19.4.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) 2.1 cum 6924.65 14542.00
Sub-Total 1211870.00
20 RAIN WATER HARVESTING & TUBEWELLS
20.1 Boring/drilling bore well of required dia for casing/ strainer pipe,
by suitable method prescribed in IS: 2800 (part I), including
collecting samples from different strata, preparing and submitting
strata chart/ bore log, including hire & running charges of all
equipments, tools, plants & machineries required for the job, all
complete as per direction of Engineer-in-charge, upto 90 metre
depth below ground level.
Page 26 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
20.3.1 150 mm nominal size dia 34 metre 746.15 25369.00
20.4 Supplying, filling, spreading & leveling stone boulders of size range
5 cm to 20 cm, in recharge pit, in the required thickness, for all
leads & lifts, all complete as per direction of Engineer-in-charge.
7 cum 1326.55 9286.00
20.5 Supplying, filling, spreading & leveling gravels of size range 5 mm
to 10 mm, in the recharge pit, over the existing layer of boulders,
in required thickness, for all leads & lifts, all complete as per
direction of Engineer-in-charge.
6.4 cum 1326.55 8490.00
20.6 Supplying, filling, spreading & leveling coarse sand of size range
1.5 mm to 2 mm in recharge pit, in required thickness over gravel
layer, for all leads & lifts, all complete as per direction of Engineer -
in-charge. 6.4 cum 1326.55 8490.00
20.7 Gravel packing in tubewell construction in accordance with IS:
4097, including providing gravel fine/ medium/ coarse, in required
grading & sizes as per actual requirement, all complete as per
direction of Engineer-in-charge.
1 cum 1497.70 1498.00
20.8 Providing and fixing factory made precast RCC perforated drain
covers, having concrete of strength not less than M-25, of size
1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal
& 9 nos cross sectional T.M.T. hoop bars, including providing 50
mm dia perforations @ 100 to 125 mm c/c, including providing
edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all
as per direction of Engineer-in-charge.
2 each 1210.85 2422.00
20.9 Providing and fixing M.S. clamp of required dia to the top of
casing/ housing pipe of tubewell as per IS: 2800 (part I), including
necessary bolts & nuts of required size complete.
20.9.1 150 mm clamp 1 each 1489.80 1490.00
20.1 Providing and fixing Bail plug/ Bottom plug of required dia to the
bottom of pipe assembly of tubewell as per IS:2800 (part I).
Page 27 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
21.1 Providing and fixing double scaffolding system (cup lock type) on
the exterior side of building/structure, upto 25 metre height,
above ground level, including additional rows of scaffolding in
stepped manner as per requirement of site, made with 40mm dia
M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical
tubes joint with cup & lock system with M.S. Tubes, M.S. tube
challis, M.S. clamps and staircase system in the scaffolding for
working platform etc. and maintaining it in a serviceable condition
for execution of work of cleaning and/ or pointing and/ or applying
chemical and removing it thereafter. The scaffolding system shall
be stiffened with bracings, runners, connecting with the building
etc, wherever required, if feasible, for inspection of work at
required locations with essential safety features for the workmen
etc., complete as per directions and approval of Engineer-in-
charge. Note:- (1) The elevational area of the scaffolding shall be
measured for payment purpose. (2) The payment will be made
once only for execution of all items for such works.
Page 28 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
23.3 "Providing and fixing C.P. pillar cock 15 mm nominal bore (L&K
make) for wash basin. 12 Each 722.50 8670.00
23.4 "Providing and fixing 15 mm nominal bore C.P brass two way bib
cock of L&K or approved equivalent make. 16 Each 1157.50 18520.00
23.5 Providing and fixing SS COAT Hook of ( Hindware cat no. F840007
approved equivalent)complete including consumable items,
cutting and making good the walls where required.
16 Each 437.53 7000.00
23.6 Providing and laying 70 mm thick factory made RCC grass Grid
paver blocks of M30 grade made by block making machine with
strong vibratory compaction, of size 600 mm x 400 mm and of
approved design, laid over and including 50 mm thick compacted
bed of fine sand, filling the joints and holes with mix of 50 %
available Earth and 50 % fine sand etc. all complete as per the
direction of Engineer-in-charge.
200 Sqm 1750.50 350100.00
23.7 Providing fabricating and erecting steel structure staircase (dog
legged) from ground level to terrace of 4th floor (up to 15.00
meter height) to make approach for workers. The work shall be
executed as per drawing/ direction of Engineer-in-Charge and
structural steel conforming to IS: 2062: Grade BR (yield srength =
350 MPa). Rate include its maintenance for damages, painting, all
incidentals, labour materials, equipment’s and works required to
execute the job. The staircase shall not be removed without prior
approval of Engineer-in-Charge. (Note: - Onetime payment shall be
made for providing staircase from start of work till completion of
work i/c dismantling of steel structure, removal from institute and
clearance of ground surface and contractor has to be submitted
vetted structural design & drawing before commencement of the
work. The material provided in staircase shall remain to be the
property of the contractor on completion of the work).
Page 29 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
23.13 Recovery of OLD polyethylene water storage tank after
disconection on terrace (at all floor levels) including cost of
removal from terrace to dumping ground. 20000 Lt -2.16 -43200.00
23.14 Extra for carriage of concrete by transit mixer beyond the initial
lead of 10 Km from concrete plant to construction site.
5814 Km 30.75 178781.00
23.15 Recovery of Hard drawn steel wire fabric of size 75 *25 mm
including dismantling with necessery cleats ,battons including
stacking the materials within 50 meter lead. 170 Sqm -160.00 -27200.00
Sub-Total 5098838.00
24 Fire Fighting System
24.1 Providing and fixing rubber expansion joints PN-16(to provide
relief from stresses at pipe flanges) as per specification of the
manufacturers.
150 mm dia 6 Each 4762.50 28575.00
24.2 Providing and fixing rubber expansion joints PN-16(to provide
relief from stresses at pipe flanges) as per specification of the
manufacturers.
80 mm dia 15 Each 4158.75 62381.00
24.3 Providing and fixing C.I double flanges suction strainer “Y” type
including, nuts, bolts and 3mm thick rubber insertion complete
"150mm dia. 2 Each 26775.00 53550.00
24.4 Providing and fixing doubble flanged butterfly valves, wafer end
type class PN 1.6 as per I.S:13095 - 1991 or BS:5155, including
necessary nuts, bolts, gaskets etc. complete (without gear box)
150 mm dia.
6 Each 10422.50 62535.00
24.5 Providing and fixing C.I double flanged horizontal/vertical type non-
return valve including nuts, bolts, 3mm thick rubber insertions
complete to I.S:5312, Part-I, swing type, class PN 1.6.
150mm dia .
4 Each 11012.50 44050.00
24.6 Providing and fixing gun metal two-way fire brigade inlet
connection consisting of 63mm instantaneously male coupling
and a check valve protected by cap scored with a chain glass
bore etc. complete with one 150mm dia sluice valve and
150mm dia non-return valve (To be connected to GF riser /
External Ring).
1 Each 13003.75 13004.00
24.7 Providing and fixing gun-metal 4-way fire brigade inlet connection
of 4 nos. 63mm dia instantaneous type male coupling with built in
check valves and 150mm dia flanged outlet complete with bolts,
nuts and rubber insertions as per I.S:904. (to be connected to
static tank).
1 Each 122272.00 122272.00
24.8 Providing and fixing gun metal fire brigade suction (draw out
connection) with female coupling as per I.S:902-1974 complete
and with 150mm dia. suction pipe and foot valve (To be connected
to static tank). 1 Each 9652.50 9653.00
Page 30 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
24.9 Supplying and fixing first-aid Hose Reel with MS construction spray
painted in post office red, conforming to IS 884 complete with the
following as required.
Connections from riser with 25 mm dia stop gun metal valve &
M.S. Pipe and socket.
40 m
10 Set 10092.00 100920.00
24.1 Providing and fixing brass ball with wheel tested to 20 Kg/cm2
(I.S:778-1971, Class - II) of approved quality for hose reel
" 10 Each 1056.00 10560.00
24.11 Providing and fixing Pressure gauge with isolation cock suitable
with ‘U’ tube for maximum pressure of 7 Kg/cm2. (0-14 Kg./cm2;
dial size:100 mm dia.) 10 Each 1577.00 15770.00
24.12 Providing and fixing landing valve hydrants to type ‘A’ of I.S: 5290-
1977 with 63mm dia S.S. instantaneous type single headed
outlet, M.S. pipe, bend and flange of required size with blank
caps and chain complete with instantaneous spring lock type
G.M. female coupling of 63mm dia for connecting hose pipe.
14 Each 13117.50 183645.00
24.13 Providing and fixing standard short size S.S. branch pipe (IS:903)
with S.S. nozzle 20mm nominal bore outlet with standard
instantaneous type 63mm dia coupling in all respects.
10 Each 4718.75 47188.00
24.14 Providing and fixing 63mm dia 15m long rubberized fabric lined
hose including S.S. male and female instantaneous type coupling,
approved by fire authority, machine wound with copper. wire
complete in all respects with hose conforming to IS:636 type-II
and coupling conforming to IS: 903-1985 with ISI certification.
30 Each 12179.00 365370.00
24.15 "Providing and fixing pre fabricated weather proof lockable
cabinet wall mounting or free standing type of size not less than
30"" x 24"" x 18"" made out of MS sheet of 1.6 mm thickness and
4 mm thick glazed glass door. suitably marked on the outside with
the letters ""FIRE HOSE"" including necessary locking arrangement
and shall be painted with one coat of primer and two coats of
synthetic enamel paint of approved shade complete in all respect.
(For External Hydrants)
"
16 Each 4856.00 77696.00
24.16 "Providing and fixing pre fabricated with 1.6mm thick MS Sheet 5
mm thick glass door (with MS frame) of size 2.1 m x 0.9 m.
Suitably marked on the outside with the letters ""FIRE HOSE""
including locking arrangement. All MS work to be in Red P.O.
colour over appropriate primer. The above item is only for
masonary fire station. 10 Each 7193.00 71930.00
24.17 "
"Providing and fixing standard fire mans axe with heavy duty
insulated rubber handle.
10 Each 1398.75 13988.00
"
Page 31 of 32
Rate in
Item.No Description of Items Qty Unit Figures in Amount
Rupees
24.18 "Providing and fixing MS black pipes as per IS 1239 (Part I) HEAVY
Class including cutting, welding etc. complete with fittings viz
Tees, Elbows, Bends, flanges, reducer, clamps, hanger etc.
including painting with one coat of primer and two coat of
synthetic enamel paint of approved make and shade.
150 mm dia
30 Rm 2217.00 66510.00
24.19 Providing and fixing MS black pipes as per IS 1239 (Part I) HEAVY
Class including cutting, welding etc. complete with fittings viz
Tees, Elbows, Bends, flanges, reducer, clamps, hanger etc.
including painting with one coat of primer and two coat of
synthetic enamel paint of approved make and shade 40 Rm 1508.00 60320.00
24.2 100 mm dia
Providing and fixing MS black pipes as per IS 1239 (Part I) HEAVY
Class including cutting, welding etc. complete with fittings viz
Tees, Elbows, Bends, flanges, reducer, clamps, hanger etc.
including painting with one coat of primer and two coat of
synthetic enamel paint of approved make and shade
80 mm dia.
10 Rm 1041.00 10410.00
24.21 Providing and fixing electrically operated flow indicating switches
with threaded connection for indicating water flow in sprinkler
branch line with necessary junction box installed in accessible
place. including cost of cable etc. complete. (Wiring from switches
to panel and stair-case pressurisation not included).
1 Each 6041.25 6041.00
24.22 Providing and fixing 25mm dia inspecting & testing assembly with
S.S. isolation valve, S.S. sight glass byepass valve & connected to
line drain complete in all respect as per standard practice of code
including pressure gauges of approved make.
1 Each 11881.25 11881.00
24.23 HAND APPLIANCES