Connectedindustrial: Function Extension Unit Ex-Barrier, Data Communication and Power Supply

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Connected Industrial

FE260
Function extension unit Ex-barrier, data
communication and power supply
Applications
• Ex-barrier for data interface and digital outputs
• Interface for the use of a data communication module
• Intrinsically safe power supply for a volume converter

Brief information
The FE260 is a compact device in which the signals from the data interface
and the digital outputs from a volume converter type EK200 series
installed in a hazardous area can be connected to the corresponding input
terminals. The signals at the output terminals are available for use with
any kind of peripheral device. In addition to this, it is possible to provide an
intrinsically safe power supply for the connected volume converter. All of the
electrical data is perfectly compatible with any of the end devices that can
be connected.

Data communication M ai n feat u res


In order to integrate the volume converter into a remote data transfer
system, the FE260 can be fi tted with a data communication module. • A ssociated apparatus for Ex-Zone 2
For this purpose, modems for a variety of telecommunication networks • Manufacturer declaration to use in Ex-Zone 2
are available to meet the necessary requirements. To connect the • Ex-barrier for data communication interface
device to an IP based network an Ethernet module can be equipped • Ex-barrier for digital outputs
alternatively. Should it be necessary to connect modems or devices from • Power supply for a volume converter

other manufacturers, standard interfaces in accordance with RS232 or • Integration in remote data transfer systems
RS422 are also available. • Modular design
• Monitoring of power supply in combination with
Power supply solar or battery power supply
The power supply of the FE260 can be either 115/230 V AC or a DC Options
voltage between 10 and 30 V DC. The latter also enables the use of • Modem modules
batteries or solar power supply. When this is the case, the voltage in
- 2G (GPRS/GSM)
combination with the volume converter can easily be monitored. If the - 3G (UMTS)
voltage falls below a certain level (either 11 V or 20 V, which can be pre- • Alternative interfaces
set), the volume converter sends out an alarm signal. - RS232 / RS422
- Ethernet (in preparation)
Versions
The FE260 is designed to be mounted on a wall. The connection cables
to the volume converter are available in a variety of lengths making the
installation of the device as easy as possible.
FE260: Function extension unit, Ex-barrier, data communication and power supply

The FE260 function extension unit – a flexible interface between volume converter and control centre
FE260 Modem Telecommunications Data recall
EK200 series
in safe area connection network from utility or
in hazardous area
service provider
Serial interface

GSM
Outputs GPRS
UMTS

Power supply

• Volume conversion • Ex-barrier data interface


• Data logging • Ex-barrier digital outputs
• Process data • Communication module (GSM/GPRS, UMTS, Ethernet, seriell interface)
• Intrinsically safe power supply for EK200 series

Technical data
Order number 83480540
Housing Cast aluminium housing for wall mounting
Dimensions 290 mm x 175 mm x 102 mm (height, width, depth) including cable connections and hinges
Weight App. 3 kg
Protection class IP 65 in accordance with EN 60529 (suitable for outdoor installation)
Associated apparatus for Ex-Zone 1, II (2) G [EEx ia] IIB
ATEX approval
Manufacturer Declaration to use in Ex-Zone 2, II 3 (3) G Ex nA IIB T4 Gc
AC Version 0 °C to +40 °C
Ambient conditions DC Version -10 °C to +60 °C (in combination with communication module see manual)
humidity max. 93%, non-condensing
Power supply 230 V AC +10% / -15%, 50...60 Hz, max. 3 Watt or
115 V AC +10% / -15%, 50...60 Hz, max. 3 Watt
alternative
10 – 30 V DC, max. 3 W
Voltage monitoring 11 V or 20 V adjustable for 12 V DC or 24 V DC power supply
(only available with the 10 – 30 V DC version)
Power output for converters 8,5 V DC / max. 40 mA output
- for external intrinsically safe power supply of a connected volume converter (EK200 series)
- not suitable for the power supply of a built-in communication module in the EK280
- recommended wire section 0.5 – 1 mm² (depending on distance to volume converter)
Display 2 status LED for indication of actual operating mode
Digital inputs 4 digital inputs for connection of digital outputs from converters
Digital outputs 4 digital outputs (with adjustable inverting) which forward the signals, connected to the particular digital input of the FE260
Modems and interface boards (option) Internal serial TTL-interface for clip on of a desired communication module
– Modem module 2G (GPRS/GSM)
– Modem module 3G (UMTS)
– Ethernet interface for connection to a PC network (intranet, internet) for TCP/IP-transmission
Cables (option) Connecting cable for data interface, digital outputs and power supply up to 1000 m corresponding to detailed
specification possible

Honeywell Process Solutions


Germany
Elster GmbH
Steinern Str. 19-21
55252 Mainz-Kastel
Elster® is a registered
T +49 6134 605 0 trademark of Elster GmbH.
F +49 6134 605 223 FE260 | 08/17
www.elster-instromet.com ©2017 Honeywell International Inc.

You might also like