03 - Structural

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 10mm Ø TIES SP.

AT
3-50 , 3-100, REST AT
200m
3.00 3.00 3.00

F1-C1 WF F1-C1 WF F1-C1 WF F1-C1


E 4-12mm.Ø RSB
4-12mm.Ø VERTICAL BARS 12mm.Ø EXTRA BAR
L/4 10mm.Ø STIRRUPS

WF

WF

WF
3.00

3.00

0.65
BACKFILL BACKFILL

F1-C1
F1-C1

F1-C1
WF WF L/6
D

F1-C1 SECTION

0.25
0.20 0.20
2.50

2.50

8.50
WF

WF

WF

WF
WF
1.00

0.30

0.30
F1-C1
SECTION
F1-C1

F1-C1

F1-C1
WF
C

WF
1.00 AT SUPPORT AT MID SPAN
0.25

4 ROOF BEAM DETAILS


3.00

3.00
WF
WF

WF

WF
WF
10-12mm.Ø BASE BARS S 1 SCALE 1 : 30 MTS.

0.25
WF WF

1.00
B

F1-C1 F1-C1 F1-C1 F1-C1


1.00
A

Ø10 mm. HOR. BARS


F1-C1 F1-C1 @ EVERY 3 LAYERS
OF CHB
3.00 3.00 3.00 PLAN Ø10 mm. VERT. BARS
SP. @ 0.80m.,O.C.

2 F1-C1 DETAILS FFL

VERIFY
9.00

1 FOUNDATION PLAN S 1 SCALE 1 : 30 MTS. NGL 0.40

0.40
4"CHB WALL

0.60
S 1 SCALE 1 : 100 MTS.

0.20
2" x 10" C-PURLINS 2-10Ø BARS
(FASCIA BOARD) LONGITUDINAL
10Ø @ 300
TRANSVERSE
2" x 5" CHANNEL BAR 0.30 BARS
A. REINFORCED CONCRETE (RAFTER)
1. THE QUALITY AND DESIGN OF ALL REINFORCED CONCRETE CONSTRUCTION
SHALL CONFORM WITH THE BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE (ACI=318.83) AND MANUAL OF STANDARD PRACTICE FOR
2" x 3"
C-PURLINS 3 WALL FOOTING DETAILS
DETAILING REINFORCED CONCRETE STRUCTURES (ACI=315.80); S 1 SCALE 1 : 30 MTS.
0.50mm. THK.
2. ALL CONCRETE SHALL BE MACHINE MIXED AND MECHANICAL VIBRATOR SHALL COLOROOF RIB TYPE
BE USED FOR COMPACTING CONCRETE;
3. MINIMUM CLEAR CONCRETE COVERING FOR REINFORCING STEEL SHALL BE: 0.75
BEAMS AND COLUMNS = 40 mm, FORMED SURFACE BELOW GRADE FOR
16 mmØ BARS AND SMALLER = 50 mm FOR BARS LARGER THAN 16 mmØ
= 75 mm, CONCRETE POURED AGAINST EARTH = 75 mm;
4. ALL REINFORCING STEEL ANCHOR BOLTS, DOWELS AND OTHER INSERTS
SHALL BE WELL SECURED IN POSITION BEFORE PLACING CONCRETE;
5. NO CONCRETING SHALL BE ALLOWED UNLESS ALL BAR PLACEMENTS HAVE
BEEN INSPECTED BY THE STRUCTURAL ENGINEER;
B. REINFORCEMENT STEEL
1. REINFORCEMENTS SHALL BE DEFORMED BARS CONFORMING TO ASTM - 322;
TO ASTM-615 (DEFORMATION);
2. MINIMUM LAP OF SPLICES UNLESS OTHERWISE SHOWN 5 TRUSS DETAILS
a) FOR CONCRETE = 50 BAR DIAMETERS NOT LESS THAN 500 mm S 1 SCALE 1 : 50 MTS.
b) FOR MASONRY = 40 BAR DIAMETERS

C. FOUNDATION
1. ALL FOOTINGS SHALL REST ON NATURAL GROUND.
PROJECT TITLE / LOCATION : OWNER / ADDRESS: SHEET CONTENTS: SHEET NO.

A S S H O W N S-1
3 5

MALIMPIN, DASOL, PANGASINAN MALIMPIN, DASOL, PANGASINAN