E Calculation For Temperature Load (IRC: 6 - 2017) : Effect of Temperature Gradient

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

E Calculation for Temperature Load ( IRC : 6 - 2017 )

Maximum air shade temperature 47.2 °C


Minimum air shade temperature -2.5 °C
Mean of max and min temperature 24.85 °C
Temperature Rise 34.85 °C
Temperature fall 14.85 °C
+/- 37.35
Ecm value is reduced to 0.5 as per IRC 112:2020, 6.4.2.5 (04)
Uniform temperature considered in the Midas Model is +/- 18.7

Effect of temperature Gradient

Temperature gradient load is applied in the Midas model in the for Differential temperature.
F= Ec*a*Dt*A
Ec= Modulus of Elasticity of concrete 3.21E+06 t/m^2
a= Coefficient of thermal expansion 1.20E-05 /° C (as per IRC 6)
Dt= Temperature Differential
A= X sectional area of of section where temperature
differential is Dt

Average Thickness of Deck 550 mm

Effect of temperature rise:


#N/A
4 13.8

0.15 m 1 2

3
0.17 m
0.55 m

0.09 m

23
0.15 m 4

2.1