0% found this document useful (0 votes)
178 views4 pages

E630-NE Data Sheet

The document provides data on Tembreak 2 E630-NE miniature circuit breakers (MCCBs), including: 1) Electrical characteristics such as rated operational voltage of 690V AC, rated insulation voltage of 800V, and ultimate breaking capacity of 10kA at 690V AC. 2) Dimensions of 260mm height, 140mm width for 3 poles, and weight of 5.0kg for 3 poles. 3) Features like adjustable thermal and magnetic protection, front connection, and direct opening action.

Uploaded by

Tosikur Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views4 pages

E630-NE Data Sheet

The document provides data on Tembreak 2 E630-NE miniature circuit breakers (MCCBs), including: 1) Electrical characteristics such as rated operational voltage of 690V AC, rated insulation voltage of 800V, and ultimate breaking capacity of 10kA at 690V AC. 2) Dimensions of 260mm height, 140mm width for 3 poles, and weight of 5.0kg for 3 poles. 3) Features like adjustable thermal and magnetic protection, front connection, and direct opening action.

Uploaded by

Tosikur Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Innovators in Protection Technology

DATA SHEET: TEMBREAK 2 E630-NE MCCB

MCCB Electrical Characteristics to IEC 60947-2, EN 60947-2, JIS C 8201-2-1 ANN.1, AS/NZS 3947-2, NEMA AB-1
Frame Reference Quantity Unit Condition TB2 E/S 630
Max In (A) of Frame 630

Model E630
Number of Poles 3, 4
Type NE

Nominal current ratings


In (A) 50oC 630

Electrical characteristics

Rated operational voltage Ue (A) AC 50/60 Hz 690


DC -
Rated insulation voltage Ui (V) 800
Rated impulse withstand voltage U imp (kV) 8

Ultimate breaking capacity I cu (kA) 690VAC 10


(IEC, JIS, AS/NZS 525VAC 15
440VAC 25
400/415VAC 36
220/240VAC 50
250V DC -

Service breaking capacity I cs (kA) 690VAC 10


(IEC, JIS, AS/NZS 525VAC 15
440VAC 25
400/415VAC 36
220/240VAC 50
250V DC -

(kA) 480VAC 15
Rated breaking capacity (NEMA) 240VAC 50

Protection

Adjustable thermal, adjustable magnetic


Fixed thermal, fixed magnetic
Microprocessor
Utilisation category A

Installation
Front connection (FC)
Extension bar (FB)
Cable clamp (FW) -
Rear connecton (RC)
Plug-in (PM) 2
Din rail mounting (DA) -
Dimensions height (mm) 260
width (mm) 3 pole, (1 pole) 140
4 pole 185
Weight depth (mm) 103
weight (kg) 3 pole, (1 pole) 5.0
4 pole 6.5

Operation

Direct OpeningAction
Toggle operation
Door mounted (HS) / breaker mounted handle (HB)
Motor operation (MC)

Endurance Electrical cycles 415VAC 4,500


Mechanical cycles 15,000

Standard Optional - Not Available MCCB cannot be used in IT systems at this voltage.
2 Not fully rated at 50oC refer to Temperature Ratings
Page 1 of 4
DATA SHEET: TEMBREAK 2 E630-NE MCCB

Outline Dimensions E630-NE

ASL: Arrangement Standard Line HL: Handle Frame Centre Line

Front connected
With extension bars
(optional)

30

Rear connected

Page 2 of 4
Innovators in Protection Technology

DATA SHEET: TEMBREAK 2 E630-NE MCCB

Outline Dimensions E630-NE with Motor Operators


ASL: Arrangement Standard Line HL: Handle Frame Centre Line

Front connected

With extension bars


(optional)

30

R ear connected with Motor Operator

Page 3 of 4
NE, S630-CE, S630-GE
Innovators in Protection Technology

c harac teris tic c urves


DATA SHEET: TEMBREAK 2 E630-NE MCCB
CE, S630-CE, S630-GE
Time/Current Characteristic Curves
E630-NE
3

2 T
hour

IR
1
Ip

40 tR
30 tp
Ig
20 Is d
ts d
10
tg
minute

Ii
6
I
4

40
30

20
Tripping Time

10

1
s econd

0.6

0.4

0.2

0.1

0.06

0.04

0.02

0.01

0.005
10

20

30

40

50

80

100
125

200

300

400

500

600

1000

1500

2000

3000

8000
4000

5000

Percen t R ated
Current I n P ercent R ated C urrent I R

I n = 630A
I R (A)
LTD Pick-up current IR xIn 0.4 0.5 0.63 0.8 0.85 0.9 0.95 1.0

Characteristics No. 1 2 3 4 5 6
11 21 21 5 10 16
LT tR (s)
at 200% x I R at 600% x I R
Standard I sd xI R 2.5 5 8
ST tsd (s) 0.1 0.2
INST Ii xI R 14(Max: 10 x I n) Note (1)
Ip xI R 0.8
PTA tp (s) 40
GF Ig xI n 0.2
Option Note(3) tg (s) 0.2
IN xI R 1.0/0.5 Note(2)
NP
tN (s) tN=tR

Note
(1) I i max. = 10 x I n. (2) 1.0 x I R or 0.5 x I R can be selected. Characteristic of neutral protection (tN vs. I N) is identical to characteristic of
phase protection (tR vs. I R). (3) When you specify GF on MCCBs with 3 poles the terminal block is automatically fitted to connect with
the external neutral CT for 3 phases 4 wires system. See terminal bl

Page 4 of 4