OV Catalogue
OV Catalogue
OV Catalogue
2021
Product Catalogue
2021
Modularly combinable product portfolio Pioneer
With over 4,000 product components in the areas of In the 1960s, our oil filters were instrumental in paving the
indoor climate, hydronics, potable water, stations way for oil heating. Today, our efficient dwelling stations are
and smart home, we always find a suitable connection. perfectly matched to regenerative energies.
Personal service Best in industry as for design
Our competent staff will be happy to assist you No other company in the heating fittings industry
by telephone or on site, for example with the design has received more awards than we have.
and commissioning of our products.
7
Oventrop
Academy
Face-to-face events Online seminars
for direct exchange on site for more flexibility
8
Contact
at a glance
INTERNATIONAL
Service Hotline
+49 2962 82100
Mo – Fr 7.30 – 16.30 h CET
9
System competence
for efficient heating, cooling
and clean potable water
Oil, Solar
Room climate
Smart Home,
Smart Building
Hydronics
Potable water
Stations,
Oil, Solar
Storage cylinders
Room climate
Hydronics
Stations, Storage cylinders
Radiator fittings and controllers Control valves for hydronics Dwelling stations
Electronic room temperature control Volume flow controllers Stations for local and district heating
Potable water
Oil, Solar
Smart Home, Smart Building
Potable water technology Solar collectors Central control and regulation technology
Aquanova System Oil heating technology
11
1 Room climate
2 Hydronics
3 Stations
Storage cylinders
4 Potable water
5 Oil
Solar
6 Smart Home
Smart Building
Room climate
Hydronic balancing at the radiator
Hydronics
Hydronic balancing with pressure independent control valves
Storage cylinders
Potable water
Shutoff valves and other products for potable water
Components for control, regulation and the building management system (BMS)
Service
Service and
data
General information
1 Room climate 2 Hydronics
1.1 Room temperature control 2.1 Hydronic balancing of risers in heating and cooling systems
1.2 Hydronic balancing at the radiator 2.2 Hydronic balancing with pressure independent control valves
Q-Tech Automatic hydronic balancing................................... 65 Cocon Q Pressure independent control valves...................... 279
Thermostatic radiator valves.................................................. 76 Actuators................................................................................. 289
Radiator lockshield valves...................................................... 97
Valve inserts for compact radiators........................................ 107 2.3 Connection and control of heating and cooling devices
H-blocks.................................................................................. 113
Optibal W6 Control ball valve................................................. 299
Heating circuit distributors/collectors for radiators.............. 124
Flypass Connection sets......................................................... 303
Connection technology.......................................................... 128
Tri-CTR Three-way valves....................................................... 309
One pipe.................................................................................. 138
Hycocon Control valves.......................................................... 313
Valve sets................................................................................ 149
14
3 Stations, Storage cylinders 5 Oil, Solar
3.1 Stations for heating circuit and cooling circuit connection 5.1 Products for heating oil installations
Regumat Stations for heating circuits.................................... 387 Deaerators and filters for oil heating technology.................. 601
Regumat Stations for solid fuel boilers.................................. 409 Tank equipment for oil heating technology........................... 612
Regumat Accessories............................................................. 414 Pipeline valves and components for oil heating technology. 625
Sets.......................................................................................... 637
3.2 Stations for local and district heating
5.2 Solar thermal energy
Regudis H Transmission stations for local and district heat-
ing networks........................................................................... 445 Regusol Stations..................................................................... 641
Regtronic Electronic controllers............................................. 658
3.3 Stations for hot potable water preparation Solar Diaphragm expansion tanks.......................................... 663
Regumaq X Fresh water stations for central hot potable OV-Flex ST Pipes and connectors........................................... 667
water preparation................................................................... 453 OKP Tube collectors............................................................... 670
Regudis W Dwelling stations for decentralised hot potable OKF Flat-plate collectors........................................................ 675
water preparation................................................................... 471 Solcos Solar packages............................................................. 683
4.1 Products for the preservation of potable water hygiene 6.2 Components for control, regulation and the building manage-
ment system (BMS)
Aquastrom Thermal circulation valves................................... 525
Aquastrom Static control valves............................................. 538 Room thermostats.................................................................. 719
Circulation and flushing stations............................................ 544 Actuators................................................................................. 730
Controllers............................................................................... 739
4.2 Shutoff valves and other products for potable water
15
Room climate
1
1.1
Thermostatic heads 19
Uni L Thermostats.......................................................................... 20
Uni L Special thermostats.............................................................. 22
Uni X Thermostats......................................................................... 25
Uni SH Thermostats....................................................................... 27
pinox Thermostats......................................................................... 28
vindo Thermostats......................................................................... 29
Uni CH Thermostats....................................................................... 30
Uni F Thermostats.......................................................................... 31
mote 200 Electronic wireless thermostat (Bluetooth).................. 32
Manual regulating heads................................................................ 33
Thermostats Accessories and spare parts..................................... 34
Room thermostats 37
ClimaCon F Room thermostats for surface heating...................... 38
Room thermostats heating............................................................ 40
Room thermostats heating/cooling.............................................. 42
Room thermostats heating/cooling with fan control.................... 43
Room thermostats Accessories..................................................... 44
R-Tronic Wireless thermostats....................................................... 46
R-Tronic Accessories....................................................................... 48
i-Tronic Climate meter.................................................................... 49
Actuators 50
Aktor T Electrothermal actuators................................................... 51
Aktor T Accessories........................................................................ 53
Aktor M Electromotive actuators................................................... 54
Actuators with radio interface........................................................ 56
Radiator sets 57
Sets with Uni LH thermostat.......................................................... 58
Sets with Uni SH thermostat.......................................................... 59
Sets with pinox thermostat............................................................ 61
Sets with vindo TH thermostat...................................................... 62
18
Room climate
1.1 Room temperature control
Thermostatic heads 19
Uni L Thermostats.......................................................................... 20
Uni L Special thermostats.............................................................. 22
Uni X Thermostats......................................................................... 25
Uni SH Thermostats....................................................................... 27
pinox Thermostats......................................................................... 28
vindo Thermostats......................................................................... 29
Uni CH Thermostats....................................................................... 30
Uni F Thermostats.......................................................................... 31
mote 200 Electronic wireless thermostat (Bluetooth).................. 32
Manual regulating heads................................................................ 33
Thermostats Accessories and spare parts..................................... 34
19
ROOM TEMPERATURE CONTROL
1.1 THERMOSTATIC HEADS
Uni L Thermostats
The Uni L thermostat impresses with its sim- The control range can be limited or blocked
ple and timeless design. Handling and reada- using the concealed limiting elements. In case
bility are optimally matched. The radiator ther- of unfavourable lighting conditions or for visu-
mostat is equipped with a memo disc to mark ally impaired persons, the basic setting “3” can
a selected setting, which makes it easy to re- easily be found again by using the palpable
set a desired temperature after turning the setting aids.
handwheel.
Colour RAL* Zero position Frost protection Control range PU Item No.
(°C)
Colour RAL* Zero position Length capillary* Control range PU Item No.
(mm) (°C)
Colour RAL* Zero position Control range Length capillary* Item No.
(°C) (mm)
The special thermostats follow the design of using the concealed limiting elements.
the Uni L thermostat. Handling and readabil- In case of unfavourable lighting conditions or
ity are optimally matched. The radiator ther- for visually impaired persons, the basic setting
mostat is equipped with a memo disc to mark “3” can easily be found again by using the pal-
a selected setting, which makes it easy to re- pable setting aids.
set a desired temperature after turning the The connection threads are specially adapted
handwheel. to the specified valve manufacturers.
The control range can be limited or blocked
Control element Liquid sensor Setting aid for visually impaired Yes
Zero position Yes persons
Frost protection Yes Blocking / Limiting Yes
Control range 7 up to 28 °C Max. heating medium tempera- 120 °C
ture
Remote sensor No
PU 10
Remote control No
Protection against vandalism No
Uni X Thermostats
The Uni X thermostat is a design oriented ra- position (factory setting). In case of unfavoura-
diator thermostat. Handling and readability are ble lighting conditions or for visually impaired
optimally matched. The radiator thermostat is persons, the basic setting “3” can easily be
equipped with a memo disc to mark a selected found again by using the palpable setting aids.
setting, which makes it easy to reset a desired
temperature after turning the handwheel. The radiator thermostat is characterised by
excellent control behaviour, optimal handling
The control range can be limited or blocked by and excellent design.
moving the limiting elements out of the park
Uni SH Thermostats
The Uni SH thermostat with liquid sensor ena- tered, unnecessary corners and edges have
bles the room temperature to be controlled in been avoided. In addition, white, chrome-plat-
a modern design. The radiator thermostat in ed and anthracite SH-Caps are available for
the new, slim design combines attractive form use in combination with a Multiblock T and
with excellent function. Handling and readabil- the corresponding design cover (see chapter
ity are excellent. “Thermostats Accessories and spare parts”).
The colour variants of the SH-Caps are match-
The discreet contours on the chrome plated ed to the colour palette of modern radiators
handle sleeve increase the ease of handling. and bathroom radiators.
In case of unfavourable lighting conditions or
for visually impaired persons, the basic setting The Uni SH thermostat is particularly recom-
can easily be found again by using the palpa- mended in combination with the Oventrop E
ble setting aids. The elegant thermostat is bal- thermostatic valves for modern living room
anced in itself. The lines are clear and unclut- design.
pinox Thermostats
pinox. The thermostat sets special accents. has already received numerous design awards
Functional and perfectly shaped, it cuts a fine in a wide range of competitions.
figure on radiators.
The handle allows for easy and precise tem- The pinox thermostat is particularly recom-
perature setting. mended in combination with the Oventrop E
thermostatic valves for modern living room
Since its market launch, the pinox thermostat design.
vindo Thermostats
The vindo thermostat is characterised by a Handling and readability are excellent. In case
simple and slim design. The reduced dimen- of unfavourable lighting conditions or for visu-
sions combine attractive form with excellent ally impaired persons, the basic setting “3” can
function. easily be found again by using the palpable
setting aids.
29
ROOM TEMPERATURE CONTROL
1.1 THERMOSTATIC HEADS
Uni CH Thermostats
The Uni CH thermostat speaks for an extrava- off by a precisely coordinated functionality.
gant design, which was created by Luigi Cola- The union nut of the thermostat can be con-
ni. cealed by a sliding cover.
The design-oriented appearance is rounded
Uni F Thermostats
The Uni F thermostat with remote control is The versions with connection thread M 30 x
particularly suitable for underfloor convectors, 1.5 are also available with an additional remote
surface heating systems and covered or con- sensor.
cealed radiators.
Colour Zero position Connection thread Length capillary* Length capillary 2* Item No.
(mm) (mm)
The electronic mote 200 wireless thermo- The wireless thermostat also offers the fol-
stat has a Bluetooth interface that can com- lowing functions: Frost protection, child-proof
municate with an app on the smartphone or lock, window open detection and battery lev-
tablet. el indicator. The mote 200 is supplied with 3
For maximum heating efficiency, the radiator adapters (Danfoss RA, RAV, RAVL) for squeeze
thermostat can be controlled via radio and in- connection.
dividual time profiles can be stored.
mote 200
32
ROOM TEMPERATURE CONTROL
THERMOSTATIC HEADS 1.1
Adapter
Angle adapter
Anti-theft ring
White, for Uni XH, XHM, LH, LHZ, L, LA, SH and vindo TH thermostats, set = 5 pieces 1011766
White, for Uni XD, LD and vindo TD thermostats, set = 5 pieces 1011775
34
ROOM TEMPERATURE CONTROL
THERMOSTATIC HEADS 1.1
Anthracite, for Uni LH, SH, XH, LA, XHM, vindo TH and pinox thermostats, set = 5 pieces 1011380
Chrome plated, for Uni LH, SH, XH, LA, XHM, vindo TH and pinox thermostats, set = 5 pieces 1011381
Gold plated, for Uni LH, SH, XH, LA, XHM, vindo TH and pinox thermostats, set = 5 pieces 1011382
Stainless steel design, for Uni LH, SH, XH, LA, XHM, vindo TH and pinox thermostats, set = 5 pieces 1011383
White, for Uni LH, SH, XH, LA, XHM, vindo TH and pinox thermostats, set = 5 pieces 1011393
Reinforcing cap
For the protection against vandalism.
For Uni LH, LHZ and LA thermostats, not lockable, white (RAL 9010) 1011865
For Uni LH, LHZ and LA thermostats, lockable, white (RAL 9010) 1011866
SH-Cap
Combined cap
For thermostatic valves, opening and closing possible with Allen screw, M 30 x 1.5 1627965
Setting key
35
ROOM TEMPERATURE CONTROL
1.1 THERMOSTATIC HEADS
Universal tool
For Uni LHB, LDB, LH and L thermostats as well as AV 9 and AQ thermostatic valves 1011489
36
1.1
Room thermostats 37
ClimaCon F Room thermostats for surface heating...................... 38
Room thermostats heating............................................................ 40
Room thermostats heating/cooling.............................................. 42
Room thermostats heating/cooling with fan control.................... 43
Room thermostats Accessories..................................................... 44
R-Tronic Wireless thermostats....................................................... 46
R-Tronic Accessories....................................................................... 48
i-Tronic Climate meter.................................................................... 49
37
ROOM TEMPERATURE CONTROL
1.1 ROOM THERMOSTATS
ClimaCon F 90 for two pipe applications, heating only/ cooling only, slave
ClimaCon F 210 for two pipe applications, heating only/ cooling only, master
Switching between time programme and manual mode possible.
Control Two point / PWM Operation At the room thermostat
Installation Surface mounting With smartphone app
Setback* Via time programme (adjustable in the Communication Bluetooth
app)
Via Eco button at the room thermostat
Room thermostats are used in conjunction ing applications by using a different actuator
with actuators for individual room tempera- (e.g. “normally closed” instead of “normally
ture control in heating systems. The temper- open”).
ature is set at the room thermostat. Depend-
ing on the room thermostat used, the temper- Oventrop offers room thermostats for surface-
ature is reduced via an adjustable time pro- and flush-mounted installation, with or with-
gramme or an external time switch. out display.
Room thermostats can also be used for cool-
Room thermostat for two pipe applications, with concealed temperature setting, surface mounting
Room thermostat for two pipe applications, with clock, surface mounting
Room thermostat for two pipe applications, with display, flush mounting
Room thermostats are used in conjunction mostat can also be used in three or four pipe
with electromotive or electrothermal actuators systems and has an adjustable neutral zone
for individual room temperature control in between heating and cooling stage. The tem-
heating and cooling systems. This room ther- perature is set at the room thermostat.
42
ROOM TEMPERATURE CONTROL
ROOM THERMOSTATS 1.1
FloorCon Electrical connecting block with automatic hydronic balancing for surface heating
FloorCon F 200, without room allocation, connection of 6 room thermostats / 8 actuators, 230 V 1400984 +
FloorCon F 300, with room allocation, connection of 10 room thermostats / 12 actuators, 230 V 1400985 +
Aktor T 2P Electrothermal actuator, two point control for FloorCon connecting block
With pre-mounted plug for direct connection to the FloorCon connecting block.
Installation position Any Valve connection Connection thread M 30 x 1.5
Installation Plug-in connection with valve adapt-
er
R-Tronic (EnOcean)
46 Desig. = Designation
EEP = EnOcean Equipment Profile
ROOM TEMPERATURE CONTROL
ROOM THERMOSTATS 1.1
TCP/
TCP/IPIP Heating zone 1 Heating zone 2
Heizzone 1 Heizzone 2
BACnet
BACnetIPIP
A
A A
A
G
G
BB
C
C
FF
24
24VV// 230
230VV
Heizen/Kühlen
C/O
C/O-Signal
Heating/
signal
E
Cooling
Heating zone 11
Heizzone Heating zone2 2
Heizzone
Heat
WP
pump
A R-Tronic RT B/R-Tronic RTF B/R-Tronic RTFC K E Aktor T2P Electrothermal actuator (two point)
Wireless thermostat F Multidis SF Heating circuit distributor/collector
B R-Con Wireless receiver G RP-S F Wireless repeater
C R-Con HC Extension module heating/cooling
D FK-C F Wireless window contact
47
ROOM TEMPERATURE CONTROL
1.1 ROOM THERMOSTATS
R-Tronic Accessories
Cover frame
PU 50
48
ROOM TEMPERATURE CONTROL
ROOM THERMOSTATS 1.1
Actuators 50
Aktor T Electrothermal actuators................................................... 51
Aktor T Accessories........................................................................ 53
Aktor M Electromotive actuators................................................... 54
Actuators with radio interface........................................................ 56
50
ROOM TEMPERATURE CONTROL
ACTUATORS 1.1
Aktor T Accessories
Valve adapter
PU 5
Reinforcing cap
53
ROOM TEMPERATURE CONTROL
1.1 ACTUATORS
Electromotive actuators are used for heating, tors/collectors (except for item no. 1012710 /
ventilation and air conditioning. Amongst oth- 11), radiant heating ceilings, cooling ceilings
ers, the actuators can be used for room tem- and induction units.
perature control. They can be used, for exam-
ple, with conventional radiators, radiators with Oventrop offers electromotive actuators with
integrated valve sets, heating circuit distribu- and without communication interfaces.
Tension Electrical emergency control function Additional two point / three point Position feedback Item No.
control
Aktor M two point and three point control, connection thread M 30 x 1.5
Cable* 1.5 m
Description Without valve anti-blocking function
Mode of operation not adjustable
Zero point detection
230 V 1012729
Aktor M two point control, with short operating time (3 s), connection thread M 30 x 1.5
Cable* 1.5 m
Description Without valve anti-blocking function
Mode of operation adjustable
230 V 1012710
24 V 1012711
Electronic battery operated actuator for room actuator is configured in the Smart Home sys-
temperature control with interface to mobile tem.
devices.
The mote 420 wireless actuator with EnOcean The mote 200 wireless actuator offers a stand-
interface can be used in combination with R- alone solution. The actuator with Bluetooth in-
Tronic wireless thermostats or be integrated terface is configured via a mobile terminal or
into Smart Home systems (e.g. wibutler). The directly at the actuator.
Radiator sets 57
Sets with Uni LH thermostat.......................................................... 58
Sets with Uni SH thermostat.......................................................... 59
Sets with pinox thermostat............................................................ 61
Sets with vindo TH thermostat...................................................... 62
57
ROOM TEMPERATURE CONTROL
1.1 RADIATOR SETS
The radiator sets consist of a thermostatic used in central heating and cooling systems
valve, a radiator lockshield valve and a Uni with closed circuits. Depending on the ther-
LH thermostat. The sets include all necessary mostatic valve, the sets are suitable for man-
components to control a radiator. They are ual or automatic hydronic balancing.
PU 10
58
ROOM TEMPERATURE CONTROL
RADIATOR SETS 1.1
The radiator sets consist of a Multiblock con- nents to connect a radiator to the pipework
nection fitting, a design cover, an SH-Cap and and to control the room temperature. They are
a Uni SH thermostat or a thermostatic valve, used in central heating and cooling systems
a radiator lockshield valve and a Uni SH ther- with closed circuits. The sets are suitable for
mostat. The sets include all necessary compo- manual hydronic balancing.
Multiblock T
For the connection to radiators with G 1/2 internal thread.
Multiblock TFU
For the connection to radiators with G 1/2 internal thread.
59
ROOM TEMPERATURE CONTROL
1.1 RADIATOR SETS
Multiblock T-RTL
For the connection to radiators with G 1/2 internal thread.
60
ROOM TEMPERATURE CONTROL
RADIATOR SETS 1.1
The radiator sets consist of a Multiblock con- face temperature regulation. They are used
nection fitting, a design cover and a pinox in central heating and cooling systems with
thermostat. The sets include all necessary closed circuits. The set are suitable for manual
components for the control of a radiator, and, hydronic balancing.
depending on the connection fitting, for sur-
2017
Multiblock T
For the connection to radiators with G 1/2 internal thread.
Multiblock T-RTL
For the connection to radiators with G 1/2 internal thread.
61
ROOM TEMPERATURE CONTROL
1.1 RADIATOR SETS
The radiators sets consist of a Multiflex F con- are used in central heating and cooling sys-
nection fitting and a vindo TH thermostat. The tems with closed cirucits. The sets are suitable
sets include all necessary components to con- for manual hydronic balancing.
trol a radiator with integrated valve set. They
PU 10
Multiflex F
62
1.2
H-blocks 113
Multiblock T Connection fittings with thermostatic valve............ 114
Multiblock T-RTL Connection fittings with thermostatic valve
and return temperature limiter...................................................... 116
Multiflex F H-blocks........................................................................ 117
63
1.2
65
HYDRONIC BALANCING AT THE RADIATOR
Q-TECH AUTOMATIC HYDRONIC BALANCING
1.2
AQ Thermostatic valves
For automatic hydronic balancing at the radia- justed between 10 and 170 l/h. A correspond-
tor in central heating and cooling systems with ing presetting key is included.
closed circuits. Installation in the supply pipe. The AQ thermostatic valves are available in
The Q-Tech valves are ideal for retrofitting and angle, straight, reversed angle and double an-
refurbishment of existing heating systems, as gle versions.
complex calculations of preset values are not The body of the valve is made of brass and the
necessary. The volume flow is kept constant surface is nickel plated. The stem is made of
even if the differential pressure in the system stainless steel.
fluctuates. The flow range can be variably ad-
AQ Angle
AQ Straight
1.2
AQ Straight (self sealing)
AQ Reversed angle
1.2
For automatic hydronic balancing in heating fluctuates. The flow range can be variably ad-
and cooling systems with closed water circuit. justed between 35 and 420 l/h. A correspond-
Installation in the supply pipe. The Q-Tech ing presetting key is included.
valves with high flow rate (AQH) are ideal The AQ thermostatic valves DN 15 are availa-
for new construction, refurbishment and ret- ble in angle, straight and reversed angle ver-
rofitting in combination with radiant ceiling sions.
panels, fan coils, radiators and other consum- The body of the valve is made of brass and the
ers. Complex pipework calculations are not surface is nickel plated. The stem is made of
necessary. The volume flow is kept constant stainless steel.
even if the differential pressure in the system
AQH Straight
AQH Angle
68 Q-Tech = Suitable for automatic hydronic balancing + New in the catalogue 2021
One pipe = Suitable for one pipe system
Two pipe = Suitable for two pipe system
HYDRONIC BALANCING AT THE RADIATOR
Q-TECH AUTOMATIC HYDRONIC BALANCING
1.2
EQ Thermostatic valves
For automatic hydronic balancing at the radia- ing presetting key is included.
tor in central heating and cooling systems with The EQ thermostatic valves are available in an-
closed circuits. Installation in the supply pipe. gle and straight versions.
The Q-Tech valves are ideal for retrofitting and The design of the exclusive radiator fittings
refurbishment of existing heating systems, as combines exceptional form with outstanding
complex calculations of preset values are not function, especially for modern radiators and
necessary. The volume flow is kept constant bathroom radiators. The body of the valve is
even if the differential pressure in the system made of brass and the surface is chrome plat-
fluctuates. The flow range can be variably ad- ed or white powder coated. The stem is made
justed between 10 and 170 l/h. A correspond- of stainless steel.
EQ Angle
EQ Straight
1.2
Multiblock TQ Angle
Multiblock TQ Straight
1.2
1.2
Multiflex FQ Straight
Multiflex FQ Angle
1.2
Anthracite 1184089
Stainless steel design 1184091
White 1184096
Chrome plated 1184098
Anthracite 1184088
Stainless steel design 1184090
White 1184095
Chrome plated 1184097
Connection thread M 30 x 1.5, including coupling set for QA and QAH valve inserts 1188051
73
HYDRONIC BALANCING AT THE RADIATOR
Q-TECH AUTOMATIC HYDRONIC BALANCING
1.2
Differential pressure measuring spindle
For all Q-Tech valves (with QA and QAH valve insert), set = 10 pieces 1187090
Covering rosette
Mounting aid
74
HYDRONIC BALANCING AT THE RADIATOR
Q-TECH AUTOMATIC HYDRONIC BALANCING
1.2
Replacement valve insert QA/QAH
Replacement nipple
76
HYDRONIC BALANCING AT THE RADIATOR
THERMOSTATIC RADIATOR VALVES
1.2
AV 9 Thermostatic valves
For manual hydronic balancing at the radiator AV 9 thermostatic valves are available in an-
in central heating and cooling system with gle, straight, reversed angle and double angle
closed circuits. Installation in the supply pipe. versions.
The integrated AV 9 valve insert allows for in- The body of the valve is made of brass and the
finitely adjustable presetting to adapt the vol- surface is nickel plated. The spindle is made of
ume flow to the required heat demand. The stainless steel.
AV 9 Angle
Nominal size kvs Pipe connection Radiator connection Certification PU Item No.
AV 9 Straight
Nominal size kvs Pipe connection Radiator connection Certification PU Item No.
1.2
AV 9 Straight (self sealing)
AV 9 Reversed angle
1.2
AV 9 Straight for return
1.2
For manual hydronic balancing at the radiator in angle and straight versions. The thermostat-
in central heating and cooling system with ic valve RFV 9 with reduced dimensions has
closed circuits. Installation in the supply pipe. been specially designed for use in confined in-
The integrated AV 9 valve insert allows for stallation conditions.
infinitely adjustable presetting to adapt the The body of the valve is made of brass and the
volume flow to the required heat demand. surface is nickel plated. The spindle is made of
The RFV 9 thermostatic valves are available stainless steel.
RFV 9 Angle
RFV 9 Straight
1.2
CV 9 Thermostatic valves
For manual hydronic balancing at the radiator CV 9 thermostatic valves are available in angle,
in central heating and cooling system with straight, and double angle versions.
closed circuits. Installation in the supply pipe. The body of the valve is made of brass and the
The integrated AV 9 valve insert allows for in- surface is chrome plated. The spindle is made
finitely adjustable presetting to adapt the vol- of stainless steel.
ume flow to the required heat demand. The
CV 9 Angle
CV 9 Straight
1.2
CV 9 Double angle right
1.2
For manual hydronic balancing at the radiator surface is nickel plated. The spindle is made of
in central heating and cooling system with stainless steel.
closed circuits. Installation in the supply pipe. The double function of these valves causes
The integrated ADV 9 valve insert allows for the valve to close automatically to 5% of the
infinitely adjustable presetting to adapt the nominal flow rate if the thermostat is disman-
volume flow to the required heat demand. The tled or destroyed (vandalism). This provides
ADV 9 thermostatic valves are available in an- the frost protection function and prevents an
gle and straight versions. uncontrolled rise in room temperature.
The body of the valve is made of brass and the
ADV 9 Angle
ADV 9 Straight
1.2
E Thermostatic valves
For manual hydronic balancing at the radiator straight, reversed angle and double angle ver-
in central heating and cooling system with sions.
closed circuits. Installation in the supply pipe. The body of the fitting is made of brass and
The integrated AV 9 valve insert allows for in- the surface is offered in different colours. The
finitely adjustable presetting to adapt the vol- spindle is made of stainless steel. With their
ume flow to the required heat demand. The exclusive design, the valves fit in perfectly with
E thermostatic valves are available in angle, modern living room design.
E Angle
E Straight
1.2
E Double angle right
E Reversed angle
1.2
A Thermostatic valves
For use at the radiator in central heating and valves are available in angle, straight, reversed
cooling system with closed circuits. Installa- angle and double angle versions.
tion in the supply pipe. The body of the valve is made of brass and the
The integrated A valve insert provides a high surface is nickel plated. The spindle is made of
flow rate, which enables use in one pipe, two stainless steel.
pipe and gravity systems. The A thermostatic
A Angle
Nominal size kvs Pipe connection Radiator connection Certification PU Item No.
A Straight
Nominal size kvs Pipe connection Radiator connection Certification PU Item No.
1.2
A Double angle right
A Reversed angle
1.2
AF Thermostatic valves
For manual hydronic balancing at the radiator The body of the valve is made of brass and the
in central heating and cooling system with surface is nickel plated. The spindle is made of
closed circuits. Installation in the supply pipe. stainless steel.
The integrated AF valve insert allows for in- The AF thermostatic valve is used especially
finitely adjustable presetting to adapt the vol- in heating systems with a high temperature
ume flow to the required heat demand. The spread (district heating systems) or in systems
AF thermostatic valves are available in angle, with small flow rates. A great advantage of the
straight, reversed angle and double angle ver- valve is the litre-precise adjustment of the flow
sions. rate at the radiator.
AF Angle
kvs Nominal size Pipe connection Radiator connection Certification Item No.
AF Straight
kvs Nominal size Pipe connection Radiator connection Certification Item No.
1.2
AF Double angle right
AF Reversed angle
1.2
AZ V Thermostatic valves
For use at radiators in central heating and zone control in combination with thermostats
cooling system with closed circuits. Installa- or actuators. The AZ V thermostatic valves are
tion in the supply pipe. available in angle and straight versions.
The integrated valve insert, which is also used The body of the valve is made of brass and the
in balancing and pipeline valves, provides a surface is nickel plated. The spindle is made of
very high flow rate, which enables use for stainless steel.
AZ V Angle
AZ V Straight
1.2
The manual regulating valves for radiators can the possibilty of subsequent conversion to
be used in one and two pipe central heating thermostatic operation by replacing the valve
systems. They enable precise manual regula- inserts. With the special tool Demo-Bloc the
tion of the room temperature. The heat output conversion can be carried out without draining
of the radiator is proportional to the setting the heating system.
of the handwheel. This sensitive regulation
is achieved by a specially shaped valve plug. The HRV manual regulating valves with pre-
The presetting is infinitely variable. It is con- setting ensure exact hydronic balancing of the
cealed and can be adjusted easily, quickly and system. They offer good manual regulation
precisely with a screwdriver. This makes it im- and also the possibility of a later, problem-free
possible for unauthorised persons to change and inexpensive conversion to thermostatic
the setting. The valve body is identical to oth- operation.
er Oventrop thermostatic valves. This enables
HRV Angle
Nominal size Presetting kvs Pipe connection Radiator connection Item No.
HRV Straight
Nominal size Presetting kvs Pipe connection Radiator connection Item No.
1.2
HR Angle
Cannot be converted to thermostatic operation.
Nominal size Presetting kvs Pipe connection Radiator connection Item No.
HR Straight
Cannot be converted to thermostatic operation.
Nominal size Presetting kvs Pipe connection Radiator connection Item No.
1.2
Connection thread M 30 x 1.5, including coupling set for QA and QAH valve inserts 1188051
Cleaning head
The valve seat can be cleaned with the Demo-Bloc and the cleaning head.
93
HYDRONIC BALANCING AT THE RADIATOR
THERMOSTATIC RADIATOR VALVES
1.2
Differential pressure measuring spindle
Coupling set
Universal tool
For Uni LHB, LDB, LH and L thermostats as well as AV 9 and AQ thermostatic valves 1011489
Presetting key
94
HYDRONIC BALANCING AT THE RADIATOR
THERMOSTATIC RADIATOR VALVES
1.2
Screen insert for QA valve insert
For all Q-Tech valves (with QA and QAH valve insert), set = 10 pieces 1187090
Measuring device
95
HYDRONIC BALANCING AT THE RADIATOR
THERMOSTATIC RADIATOR VALVES
1.2
The valve inserts are suitable for replacement valve. We recommend our Demo-Bloc for re-
in thermostatic valves. The valve inserts can placement. With this special tool, the valve in-
be preset for adaptation to the system require- sert can be replaced without draining the sys-
ments and for manual or automatic hydronic tem. Our thermostats with connection thread
balancing. The valve inserts are suitable for all M 30 x 1.5, such as the Uni LH, SH and pinox or
thermostatic valves, so you can benefit from the Uni L with connection thread M 30 x 1.0, fit
the advantages of the different valve inserts at the valve inserts.
any time without having to replace the entire
Valve insert for valves with connection thread M 30 x 1.0 (manufactured until 1998)
96
1.2
97
HYDRONIC BALANCING AT THE RADIATOR
RADIATOR LOCKSHIELD VALVES
1.2
The Combi 2 radiator lockshield valves are presetting and are suitable for use in central
suitable for the lower connection of the pi- heating and cooling systems with closed cir-
pework to radiators with conventional valve cuits. The Combi 2 radiator lockshield valves
connection. The fittings have a proportional are made of nickel plated brass.
Combi 2 Angle
Combi 2 Straight
1.2
Combi 2 Straight (self sealing)
1.2
The Combi 3 radiator lockshield valves are addition, the radiator can be drained and filled
suitable for the lower connection of the pipe- via the fitting with the help of a separate tool
work to radiators with conventional valve con- (item no. 1090551). The Combi 3 radiator lock-
nection. The fittings have a proportional pre- shield valves are made of nickel plated brass
setting and are suitable for use in central heat- or nickel plated bronze (straight version DN 10
ing and cooling systems with closed circuits. In and DN 15).
Combi 3 Angle
Nominal size Body material Radiator connection Pipe connection PU Item No.
Combi 3 Straight
Nominal size Body material Radiator connection Pipe connection PU Item No.
1.2
The Combi 4 radiator lockshield valves are closed circuits. In addition, the radiator can
suitable for the lower connection of the pipe- be drained and filled via the fitting with the
work to radiators with conventional valve con- help of a separate tool (item no. 1090551). The
nection. The fittings have a reproducible, pro- Combi 4 radiator lockshield valves are made
portional presetting and are suitable for use of nickel plated brass or nickel plated bronze
in central heating and cooling systems with (straight version DN 10 and DN 15).
Combi 4 Angle
Nominal size Body material Radiator connection Pipe connection PU Item No.
Nominal size Body material Radiator connection Pipe connection Item No.
Combi 4 Straight
Nominal size Body material Radiator connection Pipe connection PU Item No.
One pipe = Suitable for one pipe system ° Production will be discontinued 101
Two pipe = Suitable for two pipe system
HYDRONIC BALANCING AT THE RADIATOR
RADIATOR LOCKSHIELD VALVES
1.2
Combi 4 Straight (self sealing)
Nominal size Body material Radiator connection Pipe connection Item No.
102 One pipe = Suitable for one pipe system ° Production will be discontinued
Two pipe = Suitable for two pipe system
HYDRONIC BALANCING AT THE RADIATOR
RADIATOR LOCKSHIELD VALVES
1.2
The Combi E radiator lockshield valves are suitable for use in central heating and cool-
suitable for the lower connection of the pipe- ing systems with closed circuits. In addition,
work to radiators with conventional valve con- the radiator can be drained and filled via the
nection. They are available as an exclusive ver- fitting with the help of a separate tool (item
sion in various designs. The fittings have a no. 1090551). The Combi E radiator lockshield
reproducible, proportional presetting and are valves are made of brass.
Combi E Angle
DN 15 Anthracite 1166032
DN 15 Chrome plated 1166052
DN 15 White powder coated 1166062
DN 15 Gold plated 1166072
DN 15 Stainless steel design 1166082
Combi E Straight
DN 15 Anthracite 1167032
DN 15 Chrome plated 1167052
DN 15 White powder coated 1167062
DN 15 Gold plated 1167072
DN 15 Stainless steel design 1167082
1.2
The Combi C radiator lockshield valves are closed circuits. In addition, the radiator can
suitable for the lower connection of the pipe- be drained and filled via the fitting with the
work to radiators with conventional valve con- help of a separate tool (item no. 1090551). The
nection. The fittings have a reproducible, pro- Combi C radiator lockshield valves are made of
portional presetting and are suitable for use chrome plated brass.
in central heating and cooling systems with
Combi C Angle
Combi C Straight
1.2
The Combi LR radiator lockshield valves are suitable for use in central heating and cooling
suitable for the lower connection of the pi- systems with closed circuits. The Combi LR
pework to radiators with conventional valve radiator lockshield valves are made of nickel
connection. The fittings have a proportional plated brass.
presetting with increased kvs value and are
Combi LR Angle
Combi LR Straight
1.2
106
1.2
107
HYDRONIC BALANCING AT THE RADIATOR
VALVE INSERTS FOR COMPACT RADIATORS
1.2
GH GH GH GD GD GHF GHF
Baufa
Bemm
bremo
from 2013
Brötje 1994-2003
from 2003
Buderus/Brötje 1982-1986
from 2016
DEF
Dia-therm
DURA
Ferroli/IMA
HM-Heizkörper
Hoval
Korado
Manaut
Ribe
Runtal
Vasco
VEHA
108
HYDRONIC BALANCING AT THE RADIATOR
VALVE INSERTS FOR COMPACT RADIATORS
1.2
109
HYDRONIC BALANCING AT THE RADIATOR
VALVE INSERTS FOR COMPACT RADIATORS
1.2
The valve inserts are suitable for installation various types of radiators of numerous man-
in compact radiators. The valve inserts can ufacturers. Our thermostats with connection
be preset for adaptation to the system require- thread M 30 x 1.5, such as the Uni LH, SH or
ments and for manual or automatic hydronic pinox, fit the valve inserts.
balancing. The valve inserts are suitable for
PU 25
GHQ valve insert, Q-Tech, 10-170 l/h, G ½ external thread, M 30 x 1.5, with frontal seat sealing 1019080
GHQ valve insert, Q-Tech, 10-170 l/h, G ½ external thread, M 30 x 1.5, for seat diameter 16 H 11 1019082
GHQ valve insert, Q-Tech, 10-170 l/h, G ½ external thread, M 30 x 1.5, with internal O-ring 1019083
GHF valve insert, with fine presetting, G ½ external thread, M 30 x 1,5, with frontal seat sealing 1018090
GHF valve insert, with fine presetting, G ½ external thread, M 30 x 1.5, for seat diameter 16 H 11 1018097
GHF valve insert, with fine presetting, G ½ external thread, M 30 x 1.5, with internal O-ring 1018098
110
HYDRONIC BALANCING AT THE RADIATOR
VALVE INSERTS FOR COMPACT RADIATORS
1.2
GDQ Valve insert with squeeze connection
111
HYDRONIC BALANCING AT THE RADIATOR
VALVE INSERTS FOR COMPACT RADIATORS
1.2
Presetting key
112
1.2
H-blocks 113
Multiblock T Connection fittings with thermostatic valve............ 114
Multiblock T-RTL Connection fittings with thermostatic valve
and return temperature limiter...................................................... 116
Multiflex F H-blocks........................................................................ 117
Inversion fittings............................................................................. 118
H-blocks Accessories and spare parts........................................... 119
113
HYDRONIC BALANCING AT THE RADIATOR
H-BLOCKS
1.2
Multiblock T Straight
Thermostat connection Left or right hand side Filling and draining Yes
Multiblock TU Straight
1.2
Multiblock T Angle
Multiblock TU Angle
1.2
1.2
Multiflex F H-blocks
Multiflex F Angle
Radiator connection Presetting Filling and draining One pipe* Two pipe* Item No.
Multiflex F Straight
Radiator connection Presetting Filling and draining One pipe* Two pipe* Item No.
Multiflex F pivoting
Radiator connection Presetting Filling and draining One pipe* Two pipe* Item No.
1.2
Inversion fittings
Inversion fittings are connection fittings that insert to radiators with G 3/4 external thread
are designed for reversed flow and return at (Eurocone) or with G 3/4 union nut and nipple
radiators with integrated valve set. They en- to radiators with G 1/2 internal thread.
sure a correct flow against the valve insert by
exchanging the supply and return flow cross- All inversion fittings feature a shutoff function.
wise. They are available in straight and angle ver-
sions and are made of nickel plated brass. The
The fittings are soft sealing to the radiator. centre distance is 50 mm. Item no. 1016372
Depending on the version, the connection to has a reduced centre distance to the pipe net-
the radiator is either with G 3/4 union nut and work (40 mm).
Distance between pipe centres Radiator connection Pipe connection Item No.
(mm)
Distance between pipe centres Radiator connection Pipe connection Item No.
(mm)
1.2
Anthracite 1184089
Stainless steel design 1184091
White 1184096
Chrome plated 1184098
Anthracite 1184088
Stainless steel design 1184090
White 1184095
Chrome plated 1184097
White 1184092
Chrome plated 1184093
119
HYDRONIC BALANCING AT THE RADIATOR
H-BLOCKS
1.2
Design cover for Multiflex F
Covering rosette
Mounting aid
Double nipple
G ¾ external thread x G ¾ external thread, conically sealing, brass, nickel plated 1028263
120
HYDRONIC BALANCING AT THE RADIATOR
H-BLOCKS
1.2
Insert
Coupling
Effective length: 15.5 mm
Spacer
For Multiflex F, G ¾ internal thread x G ¾ external thread, nickel plated, set = 2 pieces 1681650
Covering rosette
For Multiblock T, TU, TFU, TQ and Multiflex F, plastic, centre distance 50 mm, 15 mm perforation 1016673
For Multiblock T, TU, TFU, TQ and Multiflex F, plastic, centre distance 50 mm, 16 mm perforation 1016674
121
HYDRONIC BALANCING AT THE RADIATOR
H-BLOCKS
1.2
Mounting bridge
For bridging the supply and return pipes when installing radiators at a later stage.
For installation and commissioning of the heating system without radiators 1015651
122
HYDRONIC BALANCING AT THE RADIATOR
H-BLOCKS
1.2
Replacement nipple
123
1.2
124
HYDRONIC BALANCING AT THE RADIATOR
HEATING CIRCUIT DISTRIBUTORS/COLLECTORS FOR RADIATORS
1.2
The Multidis SH heating circuit distribu- Wall brackets are loosely enclosed. Sound in-
tors/collectors for radiator connection for 2 - sulation according to DIN 4109. The heating
12 circuits are equipped with flat sealing un- circuit distributors/collectors for radiator con-
ion nut with G 1 internal thread. The heating nection are used for the central distribution
circuit connections with G ¾ external thread of the heating/cooling water to the different
are suitable for Oventrop compression fittings. radiators per dwelling unit.
2 -10 up to 90 1407252 +
3 -10 up to 90 1407253 +
4 -10 up to 90 1407254 +
5 -10 up to 90 1407255 +
6 -10 up to 90 1407256 +
7 -10 up to 90 1407257 +
8 -10 up to 90 1407258 +
9 -10 up to 90 1407259 +
10 -10 up to 90 1407260 +
11 -10 up to 90 1407261 +
12 -10 up to 90 1407262 +
1.2
Multidis SH Accessories
126
HYDRONIC BALANCING AT THE RADIATOR
HEATING CIRCUIT DISTRIBUTORS/COLLECTORS FOR RADIATORS
1.2
Ball valve with Eurocone
For Multidis SH/SF/SFQ heating circuit distributors/collectors, G 3/4 external thread x G 3/4 union nut 1406504
Surface-mounted cabinet
Flush-mounted cabinet
When using heat meter connection sets, the sum of Length (L) with ball
installation length and distributor/collector length Outlets Length (L) Cabinet no. valve item no. 1406384 Cabinet no.
must be taken into account.
2 168 mm 1 248 mm 1
32 3 218 mm 1 298 mm 1
4 268 mm 1 348 mm 1
5 318 mm 1 398 mm 1
6 368 mm 1 448 mm 1
50 7 418 mm 1 498 mm 2
200
8 468 mm 2 548 mm 2
9 518 mm 2 598 mm 2
max. 83
10 568 mm 2 648 mm 3
G1
11 618 mm 3 698 mm 3
G 3/4
52 12 668 mm 3 748 mm 3
Ring spanner
127
1.2
128
HYDRONIC BALANCING AT THE RADIATOR
CONNECTION TECHNOLOGY
1.2
For Optiflex ball valves, DN 10, G 5/8 internal thread, without fixing loop 10 1010999
For fill and drain cocks DN 25, G 1 ¼ 25 1034008
- 50 1034052
- 25 1034053
S-connection fitting
Reducer
129
HYDRONIC BALANCING AT THE RADIATOR
CONNECTION TECHNOLOGY
1.2
Reducing coupling
Reducing tail
Coupling
Elbow
Compensation fitting
For lower connection, G ¾ union nut x G ¾ external thread, brass, nickel plated 1019451
130
HYDRONIC BALANCING AT THE RADIATOR
CONNECTION TECHNOLOGY
1.2
Vent plug
G ⅜ external thread, PN 10, nickel plated, water outlet rotatable, self sealing 100 1101603
G ½ external thread, PN 10, nickel plated, water outlet rotatable, self sealing 10 1101604
Blind plug
G ⅜ external thread, PN 10, self sealing, brass, nickel plated 100 1101703
G ½ external thread, PN 10, self sealing, brass, nickel plated 10 1101704
G ¾ external thread, PN 10, self sealing, brass, nickel plated 50 1101706
Key
Drain valve
With rotatable outlet, dezincification resistant, G ¼ external thread (set = 10 pieces) 1102002
With rotatable outlet, dezincification resistant, G 3/8 external thread (set = 10 pieces) 1102003
With rotatable outlet, dezincification resistant, G ½ external thread (set = 10 pieces) 1102004
131
HYDRONIC BALANCING AT THE RADIATOR
CONNECTION TECHNOLOGY
1.2
Cofit S compression fittings for G ¾ external an additional sealing to the G ¾ internal cone.
thread are universally applicable for multi-layer The sealing to the pipe is achieved by an out-
composite pipes and, with the same process- let with additional O-ring. Clamping ring and
ing method, also for plastic pipes (PE-Xc pipes union nut are made of brass, the union nut is
and PE-RT pipes). They are soft sealing due to nickel plated. The outlet is made of bronze.
an O-ring and metal to metal sealing due to
132
HYDRONIC BALANCING AT THE RADIATOR
CONNECTION TECHNOLOGY
1.2
Ofix compression fittings for G 3/4 external ised steel pipes. Metal to metal sealing and
thread and G 3/8, G 1/2 and G 3/4 internal soft sealing variants are available. No support
thread are available for various types of pipes, sleeves are necessary for the soft sealing var-
such as copper pipes, plastic pipes, stainless iant.
steel pipes, precision steel pipes and galvan-
Suitable for:
Suitable for:
1.2
Ofix CEP for internal thread, metal to metal sealing
Ofix CEP, 2-fold, for connecting pipe, pressure screw nickel plated, metal to metal sealing.
Suitable for:
Ofix CEP for G 3/4 external thread according to DIN EN 16313, soft sealing
Ofix CEP, 2-fold, one-piece pre-assembled, for copper pipes according to DIN EN 1057, precision steel pipes accord-
ing to DIN EN 10305-1 / 2, stainless steel pipes and galvanised steel pipes, soft sealing (no support sleeves required).
Suitable for:
Ofix CEP for G 3/4 external thread according to DIN EN 16313, metal to metal sealing
Ofix CEP, 2-fold, for copper pipes according to DIN EN 1057, metal to metal sealing.
Suitable for:
134
HYDRONIC BALANCING AT THE RADIATOR
CONNECTION TECHNOLOGY
1.2
Ofix K for G 3/4 external thread according to DIN EN 16313, metal to metal sealing
Ofix K, 2-fold, for plastic pipes according to DIN EN 4726, PE-X according to DIN 16892/16893, PB according to DIN
16968 and PP according to DIN 8078 A1, metal to metal sealing plus O-ring.
Suitable for:
12 x 2 mm 2-fold 1016870
14 x 2 mm 2-fold 1016873
16 x 2 mm 2-fold 1016874
17 x 2 mm 2-fold 1016876
18 x 2 mm 2-fold 1016877
20 x 2 mm 2-fold 1016879
16 x 1.5 mm 2-fold 1016882
12 x 1.1 mm 2-fold 1016883
15 x 2.5 mm 2-fold 1016885
135
HYDRONIC BALANCING AT THE RADIATOR
CONNECTION TECHNOLOGY
1.2
10 mm 100 1029651
14 mm 100 1029653
15 mm 50 1029654
16 mm 50 1029655
18 mm 50 1029656
22 mm 50 1029657
6 mm 100 2083951
8 mm 100 2083952
136
HYDRONIC BALANCING AT THE RADIATOR
CONNECTION TECHNOLOGY
1.2
Connection of pipes, fittings, radiators, distributors/collectors etc.
for heating, sanitation and air conditioning with compression fitting
Compression fittings for Compression fittings for
G ¾ male thread according to DIN EN 16313 (Eurocone) Rp ½ female thread
Oventrop Copipe
multi-layer composite pipe and
multi-layer composite pipes Ø 14 – Ø 20 Ø 14 – Ø 16
of other manufacturers
Ø 14 – Ø 20
Plastic pipe
according to DIN 4726,
PE-X according to
DIN 16 892/16 893, Ø 14 – Ø 20
Ø 12 – Ø 20
PB according to DIN 16 968, (only PE-X pipes)
PP according to DIN 80 78 A1
Ø 12 – Ø 20
Copper pipe
DIN EN 1057
Ø 10 – Ø 18 Ø 10 – Ø 22 Ø 10 – Ø 16
Ø 10 – Ø 18
Ø 10 – Ø 18
137
1.2
138
HYDRONIC BALANCING AT THE RADIATOR
ONE PIPE
1.2
The Unofix system for the refurbishment of terval for e.g. night setback. The third variant
one pipe heating systems is based on the dif- Unofix QR has a return temperature limitation
ferential pressure independent control valve to maintain the temperature spread in partial
Cocon QTZ. It is available in different variants: load operation of the one pipe heating circuit.
As basic variant Unofix QB with pure volume Two different spacers with fixed or adjustable
flow limitation or as Unofix QT with addition- minimum stroke are available for Unofix QR to
al actuator and room thermostat with time in- ensure the residual volume flow.
1.2
Cocon QTZ with external thread PN 16, DN 10...20
Spacer
1.2
Room thermostat for two pipe applications, with display, flush mounting
1.2
The Bypass Combi Uno system is used in one through the radiator fitting when the thermo-
pipe central heating systems with forced cir- static valve is closed. The possibility of shut-
culation, with ring circuits up to 8000 watts, ting off the supply and return to the radiator
regardless of the type of heating. means that it can also be removed while the
heating system is running.
The one pipe valves and connection fittings
allow for an efficient, cost-saving installation A one pipe connection piece, a connecting
and easy dimensioning of one pipe heating pipe and a reversed angle valve, a double an-
systems. The infinitely presettable bypass al- gle valve or a straight valve with elbow, as
lows for an optimal economical design of the well as a compression fitting set are required
entire heating system. The radiator fitting of for the implementation. If the thermostat is
the one pipe connection piece can be either to face forward, the double angle valve or the
a brass fitting or an insulating fitting. The in- straight valve with elbow must be selected in-
sulating fitting largely prevents even small ra- stead of the reversed angle valve. The thermo-
diators from heating up due to the heat flow stat must be ordered separately.
Uno One pipe connection piece with infinitely adjustable bypass and shutoff
Distance between Suitable for reversed Pipe connection Description Item No.
pipe centres supply and return
(mm)
With radiator insulating fit-
50 No G 3/4 external 1013161
ting
50 No G 3/4 external With brass fitting 1013162
With radiator insulating fit-
50 Yes G 3/4 external 1013164
ting
35 No M 24 x 1.5 external With brass fitting 1182151
1.2
A Thermostatic valve
Connecting pipe
For connecting pipe, 2-fold for internal thread, G 1/2 external thread x 15 mm, metal to metal sealing 1016853
1.2
Ofix K Compression fitting M 24 x 1.5
For plastic pipes, 2-fold, 14 x 2.0 mm, metal to metal sealing 1016823
For plastic pipes, 2-fold, 16 x 2.0 mm, metal to metal sealing 1016824
For connecting pipe, flat, distance between pipe centres 35 mm, 14-16 mm perforation 1016684
Elbow
144
HYDRONIC BALANCING AT THE RADIATOR
ONE PIPE
1.2
The three-way conversion valves are suitable the valve closes, the flow through the radiator
for one pipe heating systems with forced cir- is reduced and the flow through the bypass is
culation and are often used in housing con- increased and vice versa. The three-way con-
struction in the new Federal states. The body version valves are supplied with a plastic pro-
is made of nickel plated bronze/brass. The tection cap, which serves as protection and
valve insert is made of brass and the spindle for manual operation during the construction
and spring of stainless steel. The valve disc period. The subsequent temperature control is
has a soft seal. The pipe connections are de- carried out by a thermostat. All thermostats
signed with flat-sealing external thread. When with connection thread M 30 x 1.5 can be used.
DN 15 1180584
DN 20 1180586
DN 15 1180585
DN 20 1180587
1.2
Presetting key
Fitting
DN 15, weldable tailpipe and union nut G ¾ internal thread, flat sealing to the pipework 1019374
DN 20, weldable tailpipe and union nut G 1 internal thread, flat sealing to the pipework 1019376
DN 15, G ½ internal thread / union nut G 7/8 internal thread, flat sealing to the bypass pipe 1019384
DN 20, G ¾ internal thread / union nut G 1 1/8 internal thread, flat sealing to the bypass pipe 1019386
DN 15, R ½ external thread / union nut G ¾ internal thread, flat sealing to the radiator 1019394
DN 20, R ½ external thread / union nut G 1 internal thread, flat sealing to the radiator 1019396
Shutoff fitting
Length: 45 mm
PU 25
DN 15, G ¾ external thread / union nut G ¾ internal thread, flat sealing 1016194
DN 20, G 1 external thread / union nut G 1 internal thread, flat sealing 1016196
Connection set
The conversion set as short-circuit section consists of a replacement set of the fittings located upstream of the
radiator. These components are required in addition to three-way conversion valves and insulating fittings.
Insulating fitting
To reduce the heat transfer between valve/T-piece and radiator in vertical one pipe heating systems.
146
HYDRONIC BALANCING AT THE RADIATOR
ONE PIPE
1.2
S-connection fitting
The S-connection fitting is suitable for replacing radiators with prefabricated radiators with deviating centre distance
up to max. 2 x 32 mm = 64 mm
Tailpipe set
For S-connection fitting
1.2
148
1.2
149
HYDRONIC BALANCING AT THE RADIATOR
VALVE SETS
1.2
The Bypass Combi Duo system is used in two A two pipe connection piece, a connecting
pipe central heating systems with forced circu- pipe and a reversed angle valve, a double an-
lation, regardless of the type of heating. gle valve or a straight valve with elbow, as
well as a compression fitting set are required
The two pipe valves allow for an efficient, for the implementation. If the thermostat is
cost-saving installation and easy dimensioning to face forward, the double angle valve or the
of two pipe heating systems. The possibility of straight valve with elbow must be selected in-
shutting off the supply and return to the radia- stead of the reversed angle valve. The thermo-
tor means that it can also be removed while stat must be ordered separately.
the heating system is running.
Duo Two pipe connection piece with shutoff and infinitely adjustable presetting
DN 15 1182651
DN 15 1013361
1.2
Valve with immersion pipe with shutoff
DN 15 1028750
A Thermostatic valve
Connecting pipe
1.2
Ofix CEP Compression fitting
For connecting pipe, 2-fold for internal thread, G 1/2 external thread x 15 mm, metal to metal sealing 1016853
152
1.3
Heating circuit distributors/collectors for 155 Unibox Accessories and spare parts.............................................. 215
surface heating and surface cooling
Multidis SF Heating circuit distributors/collectors for surface Surface heating with decentralised 219
heating and surface cooling........................................................... 156 distribution
Multidis SFQ Heating circuit distributors/collectors with Q-Tech. 158
Unidis Connection without distributor/collector for surface
Multidis SFI Distributors/collectors for industrial surface heat-
heating............................................................................................ 220
ing / cooling and concrete core activation..................................... 160
Unidis Accessories and spare parts............................................... 223
Multidis Accessories and spare parts............................................. 161
153
1.3
155
SURFACE HEATING AND COOLING
HEATING CIRCUIT DISTRIBUTORS/COLLECTORS FOR SURFACE HEATING AND SURFACE COOLING
10 2 -10 up to 90 1406552 +
10 3 -10 up to 90 1406553 +
10 4 -10 up to 90 1406554 +
10 5 -10 up to 90 1406555 +
10 6 -10 up to 90 1406556 +
10 7 -10 up to 90 1406557 +
10 8 -10 up to 90 1406558 +
10 9 -10 up to 90 1406559 +
10 10 -10 up to 90 1406560 +
10 11 -10 up to 90 1406561 +
10 12 -10 up to 90 1406562 +
Max. operating pressure Heating circuits kvs Operating temperature PU Item No. 1.3
(bar) (°C)
6 2 1.90 - 1405552 °
6 3 1.90 -10 up to 80 1405553 °
6 4 1.90 -10 up to 80 120 1405554 °
6 5 1.90 -10 up to 80 120 1405555 °
6 6 1.90 -10 up to 80 1405556 °
6 7 1.90 -10 up to 80 1405557 °
6 8 1.90 -10 up to 80 1405558 °
6 9 1.90 -10 up to 80 1405559 °
6 10 1.90 -10 up to 80 1405560 °
6 11 1.90 -10 up to 80 1405561 °
6 12 1.90 -10 up to 80 1405562 °
Multidis SF with integrated flow measuring and regulating devices in the flow distributor
Max. operating pressure Heating circuits Control range Operating temperature Item No.
(bar) (l/min) (°C)
6 2 0 up to 5 -10 up to 70 1406352 +
6 3 0 up to 5 -10 up to 70 1406353 +
6 4 0 up to 5 -10 up to 70 1406354 +
6 5 0 up to 5 -10 up to 70 1406355 +
6 6 0 up to 5 -10 up to 70 1406356 +
6 7 0 up to 5 -10 up to 70 1406357 +
6 8 0 up to 5 -10 up to 70 1406358 +
6 9 0 up to 5 -10 up to 70 1406359 +
6 10 0 up to 5 -10 up to 70 1406360 +
6 11 0 up to 5 -10 up to 70 1406361 +
6 12 0 up to 5 -10 up to 70 1406362 +
Multidis SF with integrated flow measuring and regulating devices in the flow distributor
Will be discontinued in the course of 2021 and replaced by item no. 1406352 - 62.
Max. operating pressure Heating circuits Control range kvs Operating temperature Item No.
(bar) (l/min) (°C)
2 Yes 1404952 +
3 Yes 1404953 +
4 Yes 1404954 +
5 Yes 1404955 +
6 Yes 1404956 +
7 Yes 1404957 +
8 Yes 1404958 +
9 Yes 1404959 +
10 Yes 1404960 +
11 Yes 1404961 +
12 Yes 1404962 +
158 Q-Tech = Suitable for automatic hydronic balancing + New in the catalogue 2021
SURFACE HEATING AND COOLING
HEATING CIRCUIT DISTRIBUTORS/COLLECTORS FOR SURFACE HEATING AND SURFACE COOLING
Heating circuits Flow rate indicator Control range Item No. 1.3
(l/min)
2 No 0.5 up to 5 1404752 °
3 No 0.5 up to 5 1404753 °
4 No 0.5 up to 5 1404754 °
5 No 0.5 up to 5 1404755 °
6 No 0.5 up to 5 1404756 °
7 No 0.5 up to 5 1404757 °
8 No 0.5 up to 5 1404758 °
9 No 0.5 up to 5 1404759 °
10 No 0.5 up to 5 1404760 °
11 No 0.5 up to 5 1404761 °
12 No 0.5 up to 5 1404762 °
Q-Tech = Suitable for automatic hydronic balancing ° Production will be discontinued 159
SURFACE HEATING AND COOLING
HEATING CIRCUIT DISTRIBUTORS/COLLECTORS FOR SURFACE HEATING AND SURFACE COOLING
Multidis SFI
2 1414452
3 1414453
4 1414454
5 1414455
6 1414456
For heat meter connection sets, G 1 external thread x G 1 union nut 1699085
Coupling
Coupling
DN 15, G 3/4 union nut x R 1/2 external thread, brass, nickel plated 1019304
161
SURFACE HEATING AND COOLING
HEATING CIRCUIT DISTRIBUTORS/COLLECTORS FOR SURFACE HEATING AND SURFACE COOLING
Surface-mounted cabinet
For Multidis SF/SFQ heating circuit distributors.
Steel, galvanised. Frame and door white lacquered.
1.3
Description PU Item No.
Flush-mounted cabinet
For Multidis SF/SFQ heating circuit distributors/collectors.
Steel, galvanised. Frame and door white lacquered. With removable screen.
When using heat meter connection sets, the sum of Length (L) with ball
installation length and distributor/collector length Outlets Length (L) Cabinet no. valve item no. 1406384 Cabinet no.
must be taken into account.
2 168 mm 1 248 mm 1
32 3 218 mm 1 298 mm 1
4 268 mm 1 348 mm 1
5 318 mm 1 398 mm 1
6 368 mm 1 448 mm 1
50 7 418 mm 1 498 mm 2
200
8 468 mm 2 548 mm 2
9 518 mm 2 598 mm 2
max. 83
10 568 mm 2 648 mm 3
G1
11 618 mm 3 698 mm 3
G 3/4
52 12 668 mm 3 748 mm 3
Cylinder lock
162
SURFACE HEATING AND COOLING
HEATING CIRCUIT DISTRIBUTORS/COLLECTORS FOR SURFACE HEATING AND SURFACE COOLING
Heat meter connection set for Multidis SFQ heating circuit distributors/collectors
For Multidis SH/SF/SFQ heating circuit distributors/collectors, G 3/4 external thread x G 3/4 union nut 1406504
164
SURFACE HEATING AND COOLING
HEATING CIRCUIT DISTRIBUTORS/COLLECTORS FOR SURFACE HEATING AND SURFACE COOLING
Bracket
Console
Terminal distributor/collector
Distributor/collector
Terminal cap
Cap (2-fold)
Vent plug
Cap
G 1 internal 1400693
Blind plug
Thermometer
Ring spanner
For heat meter connection sets, DN 20, G 1 external thread, with measuring and drain valve 1061856 °
For heat meter connection sets, DN 20, G 1 external thread, with measuring and drain valve 1062166
169
SURFACE HEATING AND COOLING
PIPES AND LAYING SYSTEMS
The plastic pipes Copex (PE-Xc) and Copert 16833 / DIN 16834. Both pipes are oxygen
(PE-RT) are suitable for surface heating and tight according to DIN 4726. The following di-
cooling. The Copex pipes comply with DIN mensions are available: 12 x 2.0 mm, 14 x 2.0
16892 / DIN 16893 / DIN EN ISO 15 875 / mm, 16 x 2.0 mm, 17 x 2.0 mm, 20 x 2.0 mm,
EN1264-4. The Copert pipes comply with DIN 26 x 3.0 mm and 32 x 3.0 mm.
170
SURFACE HEATING AND COOLING
PIPES AND LAYING SYSTEMS
1.3
171
SURFACE HEATING AND COOLING
PIPES AND LAYING SYSTEMS
Copipe HSC multi-layer composite pipes (PE- sive layer and inner medium pipe made of PE-
RT/AL/PE-RT) are suitable for surface heating RT). The following dimensions are available:
and cooling. Copipe pipes consist of 5 layers 14 x 2 mm, 16 x 2 mm, 17 x 2 mm and 20 x 2.5
(outer jacket pipe made of PE-RT, adhesive lay- mm
er, longitudinally welded aluminum pipe, adhe-
14 x 2.0 50 1541405 +
14 x 2.0 100 100 1541410 +
14 x 2.0 200 200 1541420 +
16 x 2.0 50 1541605 +
16 x 2.0 100 100 1541610 +
16 x 2.0 200 200 1541620 +
16 x 2.0 500 500 1541650 +
17 x 2.0 200 1541720 +
17 x 2.0 500 1541750 +
20 x 2.5 50 1542005 +
20 x 2.5 100 1542010 +
20 x 2.5 200 1542020 +
26 x 3.0 50 50 1542605 +
32 x 3.0 50 50 1543205 +
The Cofloor system tacker consists of base er hooks or alternatively by means of self-ad-
mat rolls or folded boards, pipes and tacker hesive clamping rails made of polypropylene.
hooks. This system can be used for new con- The base mat rolls and folded boards are laid
struction and renovation. The base mat rolls out on the raw concrete or, if necessary, on the
and the folded boards made of expanded pol- additional insulation.
ystyrene are provided with a laminated tissue
foil and have an imprinted laying grid (grid dis- The Cofloor system tacker enables inexpen-
tance 5 cm). sive, quick and easy laying of the individu-
al components. The clear picture of the lay-
Fastening of the Oventrop Copex PE-Xc, Co- ing grid facilitates a straight pipe guidance
pert PE-RT plastic pipes or the Copipe HSC when fixing the pipe with the handy Oventrop
multi-layer composite pipes (14 mm, 16 mm tacker machine. Particularly suitable for stand-
and 17 mm) is carried out by means of tack- ard-compliant concrete screed or liquid screed.
Insulation* Impact sound* Max. load Stiffness* Rd* TCG* PU Item No.
(mm) (dB(A)) (kN/m²) (MN/m²) ((m²K)/W)
Folded board
2.0 x 1.0 m = 2.0 m²
Grid* 50 mm Fire behaviour RTF-E (according to DIN EN
Material EPS 13501-1)
Pipe diameter* 14 up to 17 mm PU 5
Impact sound insulation Yes
Insulation* Impact sound* Max. load Stiffness* Rd* TCG* Item No.
(mm) (dB(A)) (kN/m²) (MN/m²) ((m²K)/W)
174 Insulation = Thickness insulation layer Grid = Laying grid / Laying distances
Impact sound = Impact sound improvement Pipe diameter = Suitable for pipe diameter
Stiffness = Dynamic stiffness TCG = Thermal conductivity group
Rd = Thermal resistivity RD
SURFACE HEATING AND COOLING
PIPES AND LAYING SYSTEMS
Clamping rail
Laying rail, self-adhesive, clamp distance 5 cm
Tacker hook
Made of plastic, for pipes 14 - 20 mm
Tacker machine
The Cofloor system base mat consists of base edge insulating strips and the overlapping of
mats and pipes. This system can be used for the base mats at the edge of the board cre-
new construction and renovation. The base ate a dense surface so that cement screed or
mats have a suitable thermal insulation made liquid screed can be applied without further
of PS (polystyrene) or EPS (expanded polystyr- sealing. This reliably prevents a sound bridge
ene) in various thicknesses (except for item to the raw concrete.
no. 1402130: only foil), which also serves as
impact sound insulation. The special geometry There are four different base mats to choose
of the nubs (grid dimension 6 cm) allows easy from. The special geometry of the nubs increa-
installation of 14 mm, 16 mm and 17 mm Co- ses the impact resistance of the nubs during
pex PE-Xc and Copert PE-RT plastic pipes and pipe installation and ensures that the heating
also Copipe HSC multi-layer composite pipes. or cooling pipes are held securely in place. The
coordinated components enable fast installa-
The handy base mats know practically no tion even with one-man installation. Particu-
waste. They can be laid economically and in a larly suitable for standard-compliant cement or
user-friendly manner in both small, angled and liquid screed.
large-area rooms. The PE foil of the optional
Base mat NP
1.44 x 0.84 m = 1.20 m²
Rd* 0.00 (m²K)/W Impact sound insulation No
Grid* 60 mm PU 14
PS 14 up to 17 1402130
11 EPS 14 up to 17 1402330
30 EPS 14 up to 17 1402430
PS 12 1402010
Compensation element 11
1.00 x 1.00 m = 1.00 m²
Max. load 60 kN/m² Impact sound insulation No
Rd* 0.31 (m²K)/W PU 5
TCG* 035
11 EPS 14 up to 17 1402390
Compensation element 30
1.00 x 1.00 m = 1.00 m²
Max. load 5 kN/m² Rd* 0.75 (m²K)/W
Stiffness* 20 MN/m² PU 5
30 EPS 14 up to 17 1402490
Insulation = Thickness insulation layer Pipe diameter = Suitable for pipe diameter 177
Impact sound = Impact sound improvement TCG = Thermal conductivity group
Rd = Thermal resistivity RD Stiffness = Dynamic stiffness
Grid = Laying grid / Laying distances
SURFACE HEATING AND COOLING
PIPES AND LAYING SYSTEMS
PS 14 up to 17 1402394
Connection element
For laying butt-jointed or butt-to-butt base mats.
PS 14 up to 17 1402393
Fixing hook
Made of plastic
For base mats, for pipes 14 and 16 mm, bag = 200 pieces 1409082
The Cofloor system Velcro consists of a base rolls are laid out on the raw concrete or, if nec-
mat with Velcro velour foil and a Velcro pipe. essary, on the additional insulation.
This system can be used for new construction
and renovation. The base mat roll has an im- The Cofloor system Velcro enables inexpen-
printed laying grid (grid distance 5 cm). sive, quick and easy laying of the individual
components. The clear picture of the laying
Fastening of the Oventrop Copert PE-RT Vel- grid facilitates straight pipe guidance. Particu-
cro plastic pipes or the 16 mm Velcro multi-lay- larly suitable for standard-compliant cement or
er composite pipes is done by simply pressing liquid screed.
the pipe onto the base mat roll. The base mat
The Cofloor system drywall consists of dry- PE-RT plastic pipes. The heat/cooling con-
wall construction elements and matching ducting lamellas are made of 0.4 mm thick and
heat/cooling conducting lamellas. The drywall the heat/cooling conducting bends of 0.5 mm
basic element consists of 25 mm thick foamed thick galvanised sheet steel and enable opti-
PS (polystyrene). It is a thermal insulation mum heat/cooling transport into the drywall
and at the same time a support element for construction elements or into the cement or
the individual heat/cooling conducting lamel- liquid screed. The practicable predetermined
las and bends. The special arrangement of the breaking points on the heat/cooling conduct-
grooves in the basic elements allows both a ing lamellas (sheet length 998 mm) enable op-
meandering and a bifilar (spiral) installation of timal laying of the pipes in the rooms.
the Oventrop Copipe HSC multi-layer compo-
site pipe 14 x 2 mm. The installation of the Cofloor system drywall
is without waste, the execution of the com-
We recommend the installation of the Copipe plete installation is possible by only one per-
HSC multi-layer composite pipe due to its low- son. Especially suitable for standard-compliant
er expansion coefficient during heating opera- cement or liquid screed, but also for dry screed
tion compared to the Copex PE-Xc and Copert elements (e.g. Fermacell panels).
For Copipe HSC multi-layer composite pipe 14 x 2 mm, made of galvanised sheet steel 1402855
181
SURFACE HEATING AND COOLING
PIPES AND LAYING SYSTEMS
Infill panel
1000 x 500 mm, thickness = 25 mm
Fire behaviour RTF-E according to DIN EN 13501-1
1.3
Description Item No.
Made of expanded polystyrene, thermal conductivity group 035, load 60 kN/m² 1402857
Membrane
182
SURFACE HEATING AND COOLING
PIPES AND LAYING SYSTEMS
Double nipple
G ¾ conically sealing according to DIN EN 16313 (Eurocone).
G ¾ external thread x G ¾ external thread, conically sealing, brass, nickel plated 1028263
183
SURFACE HEATING AND COOLING
PIPES AND LAYING SYSTEMS
Coil unwinder
For pipes, for rolls with a length up to 600 m.
Stationary 1402096
Mobile with transport chart 5 1402098
Transport chart for coil unwinder 1402099 °
Screed additive
Additive component for the production of cement screed for heated floor constructions, for homogenisation and
improvement of workability, as well as for increasing the bulk density of cement screed.
10 kg canister 1409095
Made of polyethylene foam, height: 120 mm, thickness: 10 mm, length: 1.20 m 1402091
Protective tube
For protecting heating pipes at junctions of screed joints, as well as when entering or leaving the screed.
Tape gun
For masking butt edges on the base mat rolls and insulation boards.
Adhesive tape
For masking butt edges on the base mat rolls and insulation boards againt the penetration of screed water.
50 mm x 66 m 1402599
185
1.3
186
SURFACE HEATING AND COOLING
STATIONS FOR SURFACE HEATING SYSTEMS
The Regufloor control stations are used for weather-compensated) or by a fixed value con-
flow temperature control for surface heating trol via a temperature controller with contact
and cooling systems (Regufloor HC). In this sensor (only for surface heating). Stations are
way, the maximum/minimum permissible flow available as directly operated variants as well
temperature for surface heating and cooling as with system separation.
systems can be maintained. The flow tem-
perature is controlled either by an electronic All stations are delivered pre-assembled and
control in conjunction with an actuator (e.g. tested.
Connection thread heating cir- G 3/4 exter- Max. operating temperature sec- 50 °C
cuits nal ondary side
High-efficiency pump Yes Max. operating pressure 6 bar
Max. operating temperature pri- 90 °C
mary side
Regufloor HW
Control station for flow temperature control, with Regtronic RC heating circuit controller, weather-compensated.
Heating circuit controller Max. heat output STL* Temperature control Weather-compensated Item No.
(kW)
Regufloor HN
Control station for flow temperature control, fixed value control.
Heating circuit controller Max. heat output STL* Temperature control Weather-compensated Item No.
(kW)
Regufloor HC
Control station for heating / cooling.
Heating circuit controller Max. heat output STL* Temperature control Weather-compensated Item No.
(kW)
Regufloor HX
Control station with heat exchanger for system separation.
1.3 Heating circuit controller STL* Temperature control Weather-compensated Item No.
No No Thermostatic No 1151065
T-connection piece
Bracket
190
SURFACE HEATING AND COOLING
STATIONS FOR SURFACE HEATING SYSTEMS
For Regufloor HN, Wilo-Yonos PARA with axial pump housing, without pump cable 1151089 1.3
191
SURFACE HEATING AND COOLING
STATIONS FOR SURFACE HEATING SYSTEMS
The control sets for surface heating are used m², 120 m² and 200 m². Advantages of the
to control the flow temperature of a surface control set: all components from only one sup-
heating system, e.g. for combined radiator plier, uniform warranty, coordinated compo-
and surface heating systems. The desired flow nents, simple installation, flow temperature in-
temperature is set at the temperature control- finitely adjustable between 20 °C - 50 °C, tem-
ler. The electric pipe contact safety switch perature setting can be limited and blocked as
switches off the circulation pump as soon as desired and connection possibility to all com-
the set value is exceeded due to a malfunction. mon surface heating pipes. The control set
The bypass valve is used to regulate the vol- consists of a straight valve, a bypass valve,
ume flow of the surface heating circuit. The a temperature controller with contact sensor
control set is available for floor areas up to 85 and an electric pipe contact safety switch.
192
1.3
193
SURFACE HEATING AND COOLING
ROOM THERMOSTATS AND CONTROLLERS
ClimaCon F 90 for two pipe applications, heating only/ cooling only, slave
ClimaCon F 210 for two pipe applications, heating only / cooling only, master
Switching between time programme and manual mode possible.
Control Two point / PWM Operation At the room thermostat
Installation Surface mounting With smartphone app
Setback* Via time programme (adjustable in the Communication Bluetooth
app)
Via Eco button at the room thermostat
Room thermostats are used in conjunction ing applications by using a different actuator
with actuators for individual room tempera- (e.g. “normally closed” instead of “normally
ture control in heating systems. The temper- open”).
ature is set at the room thermostat. Depend-
ing on the room thermostat used, the temper- Oventrop offers room thermostats for surface-
ature is reduced via an adjustable time pro- or flush-mounted installation, with or without
gramme or an external time switch. display.
Room thermostats can also be used for cool-
Room thermostat for two pipe applications, with concealed temperature setting, surface mounting
Room thermostat for two pipe applications, with clock, surface mounting
Room thermostat for two pipe applications, with display, flush mounting
Room thermostats are used in conjunction mostat can also be used in three or four pipe
with electromotive or electrothermal actuators systems and has an adjustable neutral zone
for individual room temperature control in between heating and cooling stage. The tem-
heating and cooling systems. This room ther- perature is set at the room thermostat.
198
SURFACE HEATING AND COOLING
ROOM THERMOSTATS AND CONTROLLERS
199
SURFACE HEATING AND COOLING
ROOM THERMOSTATS AND CONTROLLERS
Connecting blocks
1.3
The connecting block is used for wiring indi- zones for heating and cooling systems with up
vidual room controls and is used for surface to 18 actuators and 10 room thermostats can
heating and cooling control. With the connect- be connected to the connecting block. In addi-
ing block, a simple assignment of the individu- tion, further components, such as a pump, a
al rooms or heating circuits can be carried out change-over signal transmitter, a temperature
centrally. Depending on the variant, up to 10 limiter or dew point sensor can be wired.
FloorCon Electrical connecting block with automatic hydronic balancing for surface heating
FloorCon F 200, without room allocation, connection of 6 room thermostats / 8 actuators, 230 V 1400984 +
FloorCon F 300, with room allocation, connection of 10 room thermostats / 12 actuators, 230 V 1400985 +
Aktor T 2P Electrothermal actuator, two point control for FloorCon connecting block
With pre-mounted plug for direct connection to the FloorCon connecting block.
Installation position Any Valve connection Connection thread M 30 x 1.5
1.3
Installation Plug-in connection with valve adapt-
er
Sensor LW TH Electric pipe contact safety switch with concealed temperature setting
Actuators
1.3
Actuators Accessories
1.3
Valve adapter
PU 5
Reinforcing cap
204
SURFACE HEATING AND COOLING
ROOM THERMOSTATS AND CONTROLLERS
R-Tronic (EnOcean)
TCP/
TCP/IPIP Heating zone 1 Heating zone 2
Heizzone 1 Heizzone 2
BACnet
BACnetIPIP
1.3
A
A A
A
G
G
BB
C
C
FF
24
24VV// 230
230VV
Heizen/Kühlen
C/O
C/O-Signal
Heating/
signal
E
Cooling
Heating zone 11
Heizzone Heating zone2 2
Heizzone
Heat
WP
pump
A R-Tronic RT B/R-Tronic RTF B/R-Tronic RTFC K E Aktor T2P Electrothermal actuator (two point)
Wireless thermostat F Multidis SF Heating circuit distributor/collector
B R-Con Wireless receiver G RP-S F Wireless repeater
C R-Con HC Extension module heating/cooling
D FK-C F Wireless window contact
206
SURFACE HEATING AND COOLING
ROOM THERMOSTATS AND CONTROLLERS
R-Tronic Accessories
1.3
Cover frame
PU 50
Solar powered, white (similar to RAL 9003), EnOcean Equipment Profile D5-00-01 1153070
207
SURFACE HEATING AND COOLING
ROOM THERMOSTATS AND CONTROLLERS
The R-Con wireless receivers are used in com- Additional functions can be set directly at the
bination with the R-Tronic wireless thermo- wireless receiver, e.g. pump logic with adjusta-
stats for room temperature control of surface ble lead time and follow-up time, burner logic
heating systems. The electronic multi-channel for heat demand and a PWM control for sur-
wireless receivers can control up to 8 inde- face heating. Electrothermal actuators with 24
pendent heating zones according to adjustable V or 230 V can be connected to the channels
time profiles. The time profiles are set via the of the receiver.
connected wireless thermostat.
R-Con Multichannel wireless receiver for surface heating (proprietary radio communication)
Time programme adjustable with R-Tronic wireless thermostats. Item no. 1150770 / 72 additionally with pump and
burner logic. To be installed in a cabinet, the protective housing item no. 1150776 (see “R-Con Accessories”) can be
used alternatively.
Tension 230 V Installation Carrier rail (DIN EN 60715
Control Two point / PWM TH35)
Communication Proprietary radio Compatible with wibutler Yes
208
SURFACE HEATING AND COOLING
ROOM THERMOSTATS AND CONTROLLERS
Dew point monitoring, cooling mode is interrupted if the dew point is exceeded 1150774
209
SURFACE HEATING AND COOLING
ROOM THERMOSTATS AND CONTROLLERS
R-Con Accessories
1.3
Antenna extension
With SMA screw terminal, antenna length 1 m, surface mounting, white glossy (RAL 9003) 1150777
210
1.3
211
SURFACE HEATING AND COOLING
SURFACE TEMPERATURE REGULATION WITH RETURN TEMPERATURE LIMITATION
The Unibox return temperature control is used and flush valve and a cover with integrated
for surface temperature regulation of rooms handwheel. The cover of the Unibox E RTL is
with a size of up to 20 m², such as the closed. The nominal value range is adjustable
bathroom. The Uniboxes are particularly suit- between 10 °C and 50 °C for the Unibox RTL
able for retrofitting a surface temperature reg- and between 20 °C and 40°C for the Unibox E-
ulation in heating systems in combined use RTL. The cover with the integrated handwheel
with radiators. The Unibox consists of a wall enables angle and depth compensation of the
mounting box with thermostatic valve, an in- flush-mounted box installed in the wall.
tegrated return temperature limiter, a vent
Unibox RTL
Unibox E RTL
The Unibox room and return temperature con- return temperature limiter, a vent and flush
trol is used for surface temperature regulation valve, a valve insulation and a cover with
of rooms with a size of up to 20 m², such as integrated thermostat. The cover of the Uni-
the bathroom. The Uniboxes are particularly box T-RTL R-Tronic and TQ-RTL R-Tronic is
suitable for retrofitting a surface temperature closed. The nominal value range is adjustable
regulation in heating systems in combined between 20 °C and 40 °C (return temperature)
use with radiators. The Unibox is also used and between 7 °C and 28 °C (room tempera-
for individual room temperature control. The ture). The cover with the integrated thermo-
Unibox consists of a wall mounting box with stat enables angle and depth compensation of
presettable thermostatic valve, an integrated the flush-mounted box installed in the wall.
2021 2019
Unibox T-RTL
Cover Operation Cover* Colour of cover Colour operating element PU Item No.
No Internal 1022734
Unibox TQ-RTL
Cover Operation Cover* Colour of cover Colour operating element Q-Tech Item No.
1.3 Yes Thermostat Plastic White White Yes 1022739
Yes Thermostat Genuine glass White Chrome Yes 1022780
Yes Thermostat Genuine glass Black Dark chrome Yes 1022781
R-Tronic R-TB Wireless thermostat (EnOcean) for Unibox T-RTL R-Tronic and Unibox TQ-RTL R-Tronic
Room thermostat
For Unibox T vario, TQ vario, T-RTL vario, TQ-RTL vario and E BV vario.
Cover
Genuine glass white, for Unibox T-RTL vario, TQ-RTL vario, T vario, TQ vario and E BV vario, closed 1022774
Genuine glass black, for Unibox T-RTL vario, TQ-RTL vario, T vario, TQ vario and E BV vario, closed 1022775
White, for Unibox T-RTL vario, TQ-RTL vario, T vario, TQ vario and E BV vario, closed 1022776
Mounting channel
For Unibox, depth 57 mm, suitable for the wall mounting boxes 1022650
For the connection of two heating circuits, 1 x G 3/4 union nut, 2 x G 3/4 external thread 1022655
216
SURFACE HEATING AND COOLING
SURFACE TEMPERATURE REGULATION WITH RETURN TEMPERATURE LIMITATION
Extension
Valve insert
For reversed supply and return pipe, for Unibox and RTL valves 100 1026970
For Unibox and RTLH valves, M 30 x 1.5 100 1026981
For AV 9, CV 9 , RFV 9, and E thermostatic valves, Multiblock T-RTL, Unibox, M 30 x 1.5,
100 1187047
DN 10 - DN 20, kv = 0.67
For AQ, RFQ and EQ thermostatic valves, Multiblock TQ, TQ-RTL, Multiflex FQ, Unibox
25 1187065
TQ and TQ vario, 10 - 160 l/h, M 30 x 1.5
For reversed supply and return pipe, for A, AV 9, ADV 9, CV 9, E, AF, RF and RFV 9 ther-
100 1187078
mostatic valves, Multiblock T, TU and TFU as well as Unibox, M 30 x 1.5, with presetting
217
SURFACE HEATING AND COOLING
SURFACE TEMPERATURE REGULATION WITH RETURN TEMPERATURE LIMITATION
For Unibox RTL, T and plus, plastic white, depth 110 mm 1022691
218
1.3
219
SURFACE HEATING AND COOLING
SURFACE HEATING WITH DECENTRALISED DISTRIBUTION
Item No.
1022725
Unibox RLA vario (basic model) Flush-mounted box for return shutoff
Item No.
1022726
Item No.
1022723
Item No.
1022729
222
SURFACE HEATING AND COOLING
SURFACE HEATING WITH DECENTRALISED DISTRIBUTION
Mounting channel
For Unibox, made of galvanised sheet steel, H: 440-490 mm, W: 160 mm 1022653
For Unibox, with return shutoff, with cover and thermostat with remote control 1022654
Room thermostat
For Unibox T vario, TQ vario, T-RTL vario, TQ-RTL vario and E BV vario.
224
1.3
225
SURFACE HEATING AND COOLING
RETURN TEMPERATURE LIMITERS
Return temperature limiters are used in com- heating. In addition, the valve has a frost pro-
bined radiator and surface heating systems tection function. The Uni RTLH thermostats
with closed circuits. The valves are available with connection thread M 30 x 1.5 and the Uni
in reversed angle for return and straight for re- RTL thermostats with connection thread M 30
turn versions. The integrated valve insert has a x 1.0 are suitable for the valves (see chapter
double cone that prevents unintentional over- “Return temperature limiter Accessories”).
226
SURFACE HEATING AND COOLING
RETURN TEMPERATURE LIMITERS
The return temperature limiter sets consist of are available in straight for return and angle for
the valve for return temperature limitation and return versions, each with a white thermostat.
the matching Uni RTLH thermostat. The sets
Straight 1028464
227
SURFACE HEATING AND COOLING
RETURN TEMPERATURE LIMITERS
Extension
White, 10 °C - 40 °C 25 1027165
Chrome plated, 10 °C - 40 °C 25 1027172
Anthracite, with zero position, limitable and blockable, 10 °C - 70 °C 10 1149068
228
SURFACE HEATING AND COOLING
RETURN TEMPERATURE LIMITERS
229
Hydronics
2
2.1 Hydronic balancing of risers in heating and
2.1
cooling systems
232
2.1 Hydronic balancing of risers in heating and cooling
Hydronics
systems
233
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
measuring orifice
Differential pressure
regulator
Shut-off valve
Diverting/mixing valve
Control valve
Pressure independent
control valve
Volume flow regulator
Connection set
Control functions
Presetting/fix throttle
Differential pressure
control
Volume flow control
Further functions
Shut-off
Draining/Filling
Measuring (Δp)
Actuator connection
Design
Angle seat valve
Coupling/internal thread
Flange acc. to EN1092-2 PN16/PN6/ PN16 PN16
PN25
Flange acc. to ANSI Class 150
Groove PN25
Others Clamping ring
PN25
kvs value/control range kvs kPa kvs kvs kvs kvs kvs kvs kvs
DN10 LF 5...30
DN10 or 2.9
DN15 ULF 25...70
DN15 LF 0.6
DN15 3.8 3.9 1.2
DN15 HF 2.1
DN20 LF 1.0
DN20 6.8 5.7 4.8 3.7 2.6
DN20 HF
DN25 10.8 8.9 8.4 6.1
DN32 20.0 19.5 17.1 12.5
DN40 27.5 27.5 26.9 18.1
DN50 44.0 38.8 36.0 36.0 30.5
DN65 50.0 98 98 98 87
DN80 122 122 122 102
DN100 201 201 201 198
DN125 293 293 293 271
DN150 404 404 404 400
DN200 815 815 815 750
DN250 1,200 1,200 1.090
DN300 1,600 1,600 1.500
DN350 2,250
DN400 3,750
kvs value Control range volume flow Control range differential pressure
234
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
Differential pressure
control
Volume flow control
Further functions
Shut-off
Draining/Filling
Impulse line connection
Measuring (flow rate)
Via fix orifice
Measuring (Δp)
Actuator connection
Design
Angle seat valve
Straight seat valve
Multi-way valve
Connection
PN25 PN16 PN16 PN16 PN16 PN16 PN16 PN10 Internal thread
PN16 PN16 PN16 PN16 PN16 External thread
with union nuts
Coupling/internal thread
PN16 PN16 Flange acc. to EN1092-2
50.0 98 DN65
122 DN80
201 DN100
293 DN125
404 DN150
DN200
DN250
DN300
DN350
DN400
kvs value Control range volume flow Control range differential pressure
235
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
Chapter Hydronic balancing with pressure independent control valves Connection of heating/cooling devices
Product family Cocon Optibal Flypass 2-/3-way valves Hycocon control valves
QTZ QTR QFC QGC QDP W6 4TZ Tri-CTR 2+3WV ETZ HTZ
2.1 Characteristics
Nominal pressure PN25/PN16 PN25/PN16 PN25/PN16 PN25 PN25 PN16 PN16 PN16 PN16 PN16 PN16
Class 150 Class 150
Medium temperature -10...120 -10...120 -10...120 -10...120 -10...120 0...90 -10...120 -10...120 -10...120 -10...120 -10...120
Body DZR brass Bronze Cast iron, Cast iron DZR brass DZR brass DZR brass Bronze Bronze DZR brass DZR brass
nodular cast
iron
Valve type
Double regulating and
commissioning valve
Double regulating and
commissioning valve with
measuring orifice
Differential pressure
regulator
Shut-off valve
Diverting/mixing valve
Control valve
Pressure independent
control valve
Volume flow regulator
Connection set
Control functions
Presetting/fix throttle
Differential pressure
control
Volume flow control
Further functions
Shut-off
Draining/Filling
Measuring (Δp)
Actuator connection M30 x 1.5 M30 x 1.5 M30 x 1.5 M30 x 1.5 M30 x 1.5
Design
Angle seat valve
Straight seat valve
kvs value/control range l/h m³/h m³/h m³/h m³/h kvs kvs kvs kvs kvs kvs
DN10 LF 30...210
DN10 90...450
DN15 ULF
DN15 LF 30...210 1
DN15 150...1.050 3.2 22.0 2.5 1.6 1.0 1.7
DN15 HF 200...1.300 2.5
DN20 LF 4
DN20 150...1.050 max. 1.35 3.2 34.0 4.4 6.3 1.2 2.7
DN20 HF 250...1.800 5.0
DN25 400...2.500 max. 1.54 5.7 10.0 1.2 3.6
DN32 600...4.800 7.2 16.0 6.8
DN40 1.5...7.5 1.5...7.5 8.5 25.0 10.0
DN50 3.5...14 (I) 2...8 10.0 35.0
2.5...10 (E)
DN65 5...20 5...20 63
DN80 7.5...30 7,5...30 100
DN100 12.5...50 12.5...50 160
DN125 27...108 220
DN150 36...150 320
DN200 55...190
DN250
DN300
DN350
DN400
kvs value Control range volume flow Control range differential pressure
236
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
Flow control
237
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
Body material DZR brass Impulse tube connec- Yes, via HydroPort
Presetting Yes tion
Shutoff Yes Operating temperature -20 up to 150 °C
Draining With HydroPort adapt- Medium Water
er Water-glycol mixture
Measuring connection HydroPort Installation location Supply or return
Body material DZR brass Impulse tube connection Yes, via HydroPort
Presetting Yes Operating temperature -20 up to 150 °C
Shutoff Yes Medium Water
Draining Yes Water-glycol mixture
Measuring connection HydroPort Installation location Supply or return
DN 15 Rp 1/2 12 1065804 +
DN 20 Rp 3/4 12 1065806 +
DN 25 Rp 1 6 1065808 +
DN 32 Rp 1 ¼ 6 1065810 +
DN 40 Rp 1 1/2 6 1065812 +
DN 50 Rp 2 6 1065816 +
DN 15 MF Rp 1/2 12 1065824 +
DN 15 LF Rp 1/2 12 1065834 +
DN 15 ULF Rp 1/2 12 1065844 +
For automatic hydronic balancing of distribu- trol D are supplied with impulse tube and one
2.1 tion pipes in central heating and cooling sys- mounted HydroPort auxiliary valve for measur-
tems with closed circuits. The differential pres- ing, draining and filling.
sure control ensures hydronic balancing even Regulator body and all parts coming into con-
at partial load and prevents high differential tact with the medium made of dezincification
pressures in the controlled system section, resistant brass, stainless steel or EPDM. Main-
e.g. at the radiator valve. When using a Hydro- tenance-free spindle sealing. Impulse tube 1 m
Control V as partner valve, the water quantity long.
in the riser can also be measured with the help The new HydroControl D differential pressure
of the OV-DMC 3 measuring system with the regulators are characterised by robust design,
impulse tube connected. Installation only in precise presetting and excellent control quali-
the return pipe. ty.
Y-pattern valve with secured, at any time con-
trollable, infinitely adjustable presetting of the Suitable connection fittings see section “Con-
desired nominal differential pressure value. All nection technology”
functions accessible from the top. HydroCon-
HydroControl D with internal thread PN 25, DN 15…50, nominal value range 5...30 kPa (50…300 mbar)
Nominal size Connection size Nominal value differential pressure Item No.
(mbar)
HydroControl D with internal thread PN 25, DN 15…50, nominal value range 25...70 kPa (250…700 mbar)
Nominal size Connection size Nominal value differential pressure Item No.
(mbar)
HydroControl D with external thread PN 16, DN 15…50, nominal value range 5...30 kPa (50…300 mbar)
Flat sealing, without union nut and sealing ring.
Nominal size Connection size Nominal value differential pressure Item No.
(mbar)
For shutting off distribution pipes in central Valve body and all parts coming into contact
2.1 heating and cooling systems with closed cir- with the medium made of dezincification re-
cuits. Installation in the supply or the return sistant brass, stainless steel, EPDM or PTFE.
pipe. Maintenance-free spindle sealing.
Y-pattern valve without presetting. Supplied The new HydroControl A shutoff valves are
with one HydroPort auxiliary valve for measur- characterised by robust design and perma-
ing, draining and filling which can also be used nently reliable operation.
to connect the impulse tube of a HydroControl
D differential pressure regulator under system Suitable connection fittings see section “Con-
pressure. nection technology”.
HydroControl VTR with internal thread PN 25, DN 10…50, with mounted Classic measuring valve and fill and drain
ball valve
Nominal sizes DN 10 to DN 20 suitable for compression fittings item no. 10271..
Body material Bronze Operating temperature -20 up to 150 °C
Draining Yes Medium Water
Measuring connection Classic Water-glycol mixture
Impulse tube connection Yes
HydroControl VTR with internal thread PN 25, DN 10…50, with two mounted Classic measuring valves
Nominal sizes DN 10 to DN 20 suitable for compression fittings item no. 10271..
Body material Bronze Operating temperature -20 up to 150 °C
Draining Extendable (only depressurised) Medium Water
Measuring connection Classic Water-glycol mixture
Impulse tube connectionExtendable (only depressurised)
2.1
DN 10 G⅝ 2.88 10 1060503 °
DN 15 G 3/4 3.88 10 1060504 °
DN 20 G1 5.71 10 1060506 °
DN 25 G1¼ 8.89 10 1060508 °
DN 32 G 1 1/2 19.45 5 1060510 °
DN 40 G 1 3/4 27.51 5 1060512 °
DN 50 G 2 3/8 38.78 5 1060516 °
HydroControl VFC with flanges according to EN 1092-2 PN 16, DN 20…400, with two mounted Classic measuring
valves
HydroControl VFN with flanges according to EN 1092-2 PN 25, DN 65…300, with two mounted Classic measuring
valves
DN 65 98.00 1062451
DN 80 122.00 1062452
DN 100 201.00 1062453
DN 125 293.00 1062454
DN 150 404.00 1062455
DN 200 815.00 2 1062456
DN 250 1,200.00 1062457
DN 300 1,600.00 1062458
HydroControl VFC with flanges according to EN 1092-2 PN 6, DN 20…200, with two mounted Classic measuring
valves
DN 20 4.80 1062676
DN 25 8.40 1062677
DN 32 17.10 1062678
DN 40 26.90 1062679
DN 50 36.00 1062680
DN 65 98.00 1062681
DN 80 122.00 1062682
DN 100 201.00 1062683
DN 125 293.00 1062684
DN 150 404.00 1062685
DN 200 815.00 1062686
246
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
HydroControl VFC with flanges PN 16 with hole circles according to ANSI class 150, 3/4...16 inch (DN 20...400), with
two mounted Classic measuring valves
2.1
Nominal size Body material kvs PU Item No.
HydroControl VGC with grooves PN 25, DN 65…300, with two mounted Classic measuring valves
Suitable for couplings of the Victaulic, Grinnell, or similar systems.
Body material Cast iron Operating temperature -10 up to 150 °C
Draining Extendable (only depressurised) Medium Water
Measuring connection Classic Water-glycol mixture
Impulse tube connectionExtendable (only depressurised)
247
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
HydroControl VFR with flanges according to EN 1092-2 PN 16, DN 50…200, with two mounted Classic measuring
valves, body made of bronze
DN 50 36.00 1062350
DN 65 98.00 1062351
DN 80 122.00 1062352
DN 100 201.00 1062353
DN 125 293.00 1062354
DN 150 404.00 10 1062355
DN 200 815.00 2 1062356
248
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
HydroControl VFC with flanges according to EN 1092-2 PN 16, DN 20…50, with two mounted Classic measuring
valves
DN 20 4.80 1688746
DN 25 8.40 1688747
DN 32 17.10 1688748
DN 40 26.90 1688749
DN 50 36.00 1688750
249
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
HydroControl VFR with flanges according to EN 1092-2 PN 16, DN 50 and DN 200, with two mounted Classic
measuring valves
HydroControl MTR with internal thread PN 25, DN 15...50, with two mounted Classic measuring valves
HydroControl MTR with external thread PN 16, DN 15...20, with two mounted Classic measuring valves
Flat sealing, without union nut and sealing ring.
Body material Bronze PU 10
Operating temperature -20 up to 150 °C
HydroControl MFC with flanges according to EN 1092-2 PN 16, DN 65…300, with two mounted Classic measuring
valves
252
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
253
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCONTROL BALANCING AND PIPELINE VALVES
For shutting off distribution pipes in central Valve body and all parts coming into contact
2.1 heating and cooling systems with closed cir- with the medium made of dezincification re-
cuits. Installation in the supply or the return sistant brass, stainless steel, EPDM or PTFE.
pipe. Maintenance-free spindle sealing.
Y-pattern valve without presetting. With two HydroControl ATR will be replaced with the
measuring connections closed with blind new HydroControl A during 2012.
plugs. Diffusion tight thermal insulation shells
up to 120 °C available as accessories for nomi- Suitable connection fittings see section “Con-
nal sizes up to DN 50. nection technology”.
DN 65 98.00 36 1062051
DN 80 122.00 36 1062052
DN 100 201.00 18 1062053
DN 125 293.00 16 1062054
DN 150 404.00 10 1062055
Thermal insulation shell made polyurethane rigid foam with polystyrene shell
For HydroControl VFC, VFN, VFR and VGC as well as HydroControl AFC.
Made of polyurethane rigid foam with polystyrene shell. For heating and cooling systems. Operating temperature:
-10 to + 130 °C. Building material class B2 according to DIN 4102. Complies with the German Energy Saving
Ordinance (EnEV) according to appendix 5, table 1, line 5. Cold insulation: Min. medium temperature 6 °C, shells
have to be bonded hermetically. Restricted diffusion tightness at low medium temperature and at high ambient
temperature and/or air humidity.
DN 20 1062581
DN 25 1062582
DN 32 1062583
DN 40 1062584
DN 50 1062585
DN 65 1062586
DN 80 1062587
DN 100 7 1062588
DN 125 1062589
DN 150 1062590
Blocking set
For HydroControl VTR, VFC, VFN, VFR, VGC, MTR and MFC up to DN 50.
PU 25
Identification ring
Can be clipped onto the handwheel for riser identification. For HydroControl VTR, VFC, VFN, VFR, VGC, MTR and
MFC up to DN 50.
PU 50
Replacement insert
For HydroControl VTR, VFC, VFN, VFR, VGC, MTR and MFC up to DN 50.
DN 10 1069003
DN 15 1069004
DN 20 1069006
2.1
DN 25 1069008
DN 32 1069010
DN 40 1069012
DN 50 1069016
258
2.1 Hydronic balancing of risers in heating and cooling 2.1
systems
259
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROMAT DIFFERENTIAL PRESSURE REGULATORS
Nominal size Connection size kvs Nominal value differential pressure PU Item No.
(mbar)
Nominal size Connection size kvs Nominal value differential pressure Item No.
(mbar)
2.1
DN 15 G 3/4 2.50 50 up to 300 1064604 °
DN 20 G1 5.00 50 up to 300 1064606 °
DN 25 G1¼ 7.50 50 up to 300 1064608 °
DN 32 G 1 1/2 10.00 50 up to 300 1064610 °
DN 40 G 1 3/4 15.00 50 up to 300 1064612 °
DN 50 G 2 3/8 34.00 50 up to 300 1064616 °
DN 15 G 3/4 2.50 250 up to 700 1064804 °
DN 20 G1 5.00 250 up to 700 1064806 °
DN 25 G1¼ 7.50 250 up to 700 1064808 °
DN 32 G 1 1/2 10.00 250 up to 700 1064810 °
DN 40 G 1 3/4 15.00 250 up to 700 1064812 °
DN 50 G 2 3/8 34.00 250 up to 700 1064816 °
Hydromat DFC with flanges PN 16 with hole circles according to ANSI class 150, 2 1/2…6 inch (DN 65…150)
DN 15 50 up to 300 1064592
DN 20 50 up to 300 1064593
DN 25 50 up to 300 1064594
DN 32 50 up to 300 1064595
DN 40 50 up to 300 1064596
DN 50 50 up to 300 1064597
DN 15 250 up to 700 1064792
DN 20 250 up to 700 1064793
DN 25 250 up to 700 1064794
DN 32 250 up to 700 1064795
DN 40 250 up to 700 1064796
DN 50 250 up to 700 1064797
PU 10
264
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
HYDROCOM AND HYCOCON BALANCING AND PIPELINE VALVES
Body material DZR brass Impulse tube connec- Yes, via HydroPort
Presetting Yes tion
Shutoff Yes Operating temperature -20 up to 120 °C
Draining With HydroPort adapt- Medium Water
er Water-glycol mixture
Measuring connection HydroPort Installation location Supply or return
Body material DZR brass Impulse tube connec- Yes, via HydroPort
Presetting No tion
Shutoff Yes Operating temperature -20 up to 120 °C
Draining With HydroPort Medium Water
adapter Water-glycol mixture
Measuring connection No Installation location Supply or return
For automatic hydronic balancing of distribu- to 110 °C included in the scope of delivery (not
2.1 tion pipes in central heating and cooling sys- diffusion tight). Diffusion tight thermal insula-
tems with closed circuits. The differential pres- tion shells up to 120 °C available as accesso-
sure control ensures hydronic balancing even ries.
at partial load and prevents high differential Valve body, bonnet, regulator bowl and all
pressures in the controlled system section, parts coming into contact with the medium
e.g. at the radiator valve. Installation only in made of dezincification resistant brass or
the return pipe. EPDM. Valve plug with soft seal. With two
Straight seat valve as proportional controller mounted measuring and draining valves with
working without auxiliary energy. Infinitely ad- Eco measuring technique.
justable nominal value. Nominal value can be Hycocon DTZ will be replaced with the new
blocked and read from outside at any time. HydroCom D during 2021.
With direct shutoff and the option of draining
and filling. Connection set, drain valve and Suitable connection fittings see section “Con-
thermal insulation shells for temperatures up nection technology”.
Nominal size Connection size kvs Nominal value differential pressure PU Item No.
(mbar)
Nominal size Connection size kvs Nominal value differential pressure PU Item No.
(mbar)
PU 10
DN 15 1061771 °
DN 20 1061772 °
DN 25 1061773 °
DN 32 1061774 °
DN 40 1061775 °
DN 15 1061781 °
DN 20 1061782 °
DN 25 1061783 °
DN 32 1061784 °
DN 40 1061785 °
DN 15 1061793 °
DN 20 1061794 °
DN 25 1061795 °
DN 32 1061796 °
DN 40 1061797 °
Diaphragm actuator
For the conversion of a Hycocon ATZ shutoff valve or a Hycocon VTZ double regulating and commissioning valve
to a Hycocon DTZ differential pressure regulator. Note that the impulse tube supplied requires a connection in the
supply pipe (or the return pipe if the valve to be converted is installed in the supply pipe). DN 15 to DN 25: the valve
insert must be replaced for the conversion (enclosed). This can be done with the Oventrop Demo-Bloc special tool
under system pressure.
PU 10
2.1
PU 50
Adapter for connecting the impulse tube to a G 3/4 external thread 1062090
Adapter for connecting the impulse tube to a G 1/4 internal thread 1609302
Measuring adapter with quick-coupling technique for drain and fill tool 50 1060297 °
Drain and fill tool 1061791 °
2 measuring needles for OV-DMC 3, OV-DMC 2 and OV-DMPC 25 1061799 °
Demo-Bloc
Special tool for the replacement of Hycocon valve inserts DN 15 to DN 25 under system pressure - except for
Hycocon DTZ differential pressure regulators.
Connection thread M 30 x 1.5, including coupling set for QA and QAH valve inserts 1188051
Differential pressure measuring spindle 1188093
2.1 Cleaning head for all valves 100 1188400
PU 10
PU 10
Measuring and draining unit for valves with Eco measuring technique 1061790 °
Plug for valves with Eco measuring technique 1061798 °
275
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
OTHER BALANCING AND PIPELINE VALVES
For hydronic balancing of distribution pipes Axial valve with infinitely adjustable presetting
2.1 in central heating and cooling systems with and shutoff. Body made of brass.
closed circuits. The integrated flow rate dis-
play allows for easy balancing by directly read- Suitable connection fittings see section “Con-
ing the water quantity. Installation in the sup- nection technology”.
ply or the return pipe.
PU 655
DN 25 G1 5.50 5 - 40 1060925
276
HYDRONIC BALANCING OF RISERS IN HEATING AND COOLING SYSTEMS
OTHER BALANCING AND PIPELINE VALVES
DN 20 Rp 3/4 1085206
DN 25 Rp 1 1085208
DN 32 Rp 1 ¼ 1085210
277
2.2 Hydronic balancing with pressure independent
control valves
2.2
Actuators 289
Aktor T Electrothermal actuators................................................... 292
Aktor T Accessories and spare parts............................................. 293
Aktor M Electromotive actuators................................................... 294
Aktor M Accessories....................................................................... 297
278
2.2 Hydronic balancing with pressure independent
control valves
2.2
279
HYDRONIC BALANCING WITH PRESSURE INDEPENDENT CONTROL VALVES
COCON Q PRESSURE INDEPENDENT CONTROL VALVES
Pressure independent control valve for dy- Valves with blind plugs can be retrofitted with
namic hydronic balancing of heat exchangers, Classic measuring valves. All DN 15 and DN 20
for example fan coils or cooling ceilings and valves are suitable for copper pipe.
distribution pipes in heating and cooling sys- Valve body and parts coming into contact with
tems with closed circuits. The valve combina- the medium made of dezincification resistant
2.2 tion consists of an automatically operating brass, plastic, stainless steel, EPDM or PTFE.
flow controller and a control valve and can be Maintenance-free spindle sealing.
equipped with an actuator or a manual regu- Cocon QTZ are characterised by easy adjust-
lating head. Installation in the supply or the ability, compact dimensions and best control
return pipe. quality.
Two-way valve, with secured, lead sealable,
infinitely adjustable flow limitation. Direct set- Suitable connection fittings see section “Con-
ting in litres per hour. Readability of the set nection technology”.
value independent of the handwheel position.
Nominal size Connection size Control range Pressure rating PU Item No.
(l/h)
Cocon QTZ with coupling and internal thread, DN 15…32, with two mounted Classic measuring valves
Nominal size Connection size Control range Pressure rating PU Item No.
(l/h)
Nominal size Connection size Control range Pressure rating PU Item No.
(l/h)
Cocon QTZ with external thread, DN 10…32, with two mounted Classic measuring valves
Nominal sizes DN 10, DN 25 and DN 32 flat sealing. Nominal sizes DN 15 and DN 20 conically sealing, with insert
1661100 (for DN 15) or 1650793 (for DN 20) flat sealing.
Nominal size Connection size Control range Pressure rating PU Item No.
(l/h)
Nominal size Connection size Control range Pressure rating PU Item No.
(l/h)
Cocon QTZ with internal thread, DN 15...32, with two mounted Classic measuring valves
Nominal size Connection size Control range Pressure rating PU Item No.
(l/h)
Cocon QTZ with external thread, DN 15…20, with two mounted Classic measuring valves and mounted measuring
orifice
PU 10
Nominal size Connection size Control range Pressure rating Item No.
(l/h)
Pressure independent control valve for dy- hour. Readability of the set value independent
namic hydronic balancing of heat exchangers, of the handwheel position.
for example fan coils or air conditioning units Valve body and parts coming into contact
and distribution pipes in heating and cooling with the medium made of bronze, dezincifica-
systems with closed circuits. The valve combi- tion resistant brass, stainless steel, EPDM or
nation consists of an automatically operating PTFE. Maintenance-free spindle sealing. Sup- 2.2
flow controller and a control valve and can plied with two Classic measuring valves.
be equipped with an actuator. Installation in Cocon QTR are characterised by easy adjust-
the supply or the return pipe.Two-way valve, ability, compact dimensions and best control
with secured, lead sealable, infinitely adjusta- quality.
ble flow limitation. Direct setting in m³ per
Cocon QTR with internal thread PN 25, DN 40...50, with two mounted Classic measuring valves
DN 50 Rp 2 3.5 up to 14 1143116
DN 40 Rp 1 1/2 1.5 up to 7.5 50 1146112
Cocon QTR with external thread PN 16, DN 40...DN50, with two mounted Classic measuring valves
Flat sealing, without union nut and sealing ring.
283
HYDRONIC BALANCING WITH PRESSURE INDEPENDENT CONTROL VALVES
COCON Q PRESSURE INDEPENDENT CONTROL VALVES
Pressure independent control valve for dy- independent of the handwheel position.
namic hydronic balancing of heat exchangers, Valve body made of cast iron or nodular cast
for example air conditioning units and distribu- iron, parts coming into contact with the me-
tion pipes in heating and cooling systems with dium made of cast iron, nodular cast iron,
closed circuits. The valve combination consists bronze, dezincification resistant brass, stain-
2.2 of an automatically operating flow controller less steel, EPDM or PTFE. Maintenance-free
and a control valve and can be equipped with spindle sealing. Supplied with two Classic
an actuator. Installation in the supply or the measuring valves.
return pipe. Cocon QFC and QGC are characterised by
Two-way valve, with secured, lead sealable, easy adjustability, compact dimensions and
infinitely adjustable flow limitation. Direct set- best control quality.
ting in m³ per hour. Readability of the set value
Cocon QFC with flanges according to EN 1092-2 PN 16, DN 40…200, with two mounted Classic measuring valves
Cocon QFC with flanges according to EN 1092-2 PN 25, DN 40…200, with two mounted Classic measuring valves
284
HYDRONIC BALANCING WITH PRESSURE INDEPENDENT CONTROL VALVES
COCON Q PRESSURE INDEPENDENT CONTROL VALVES
Cocon QFC with flanges PN 16 with hole circles according to ANSI class 150, 1 1/2…8 inch (DN 40…200), with two
mounted Classic measuring valves
Cocon QGC with grooves PN 25, DN 65…100, with two mounted Classic measuring valves
DN 65 73.0 5 up to 20 1676351 +
DN 80 88.9 7.5 up to 30 1676352 +
DN 100 114.3 12.5 up to 50 1676353 +
DN 20 G1 up to 1,350 1144606
DN 25 G1¼ up to 1,540 1144608
286
HYDRONIC BALANCING WITH PRESSURE INDEPENDENT CONTROL VALVES
COCON Q PRESSURE INDEPENDENT CONTROL VALVES
DN 15 Rp 1/2 1149004 °
2.2
2.2
Actuators 289
Aktor T Electrothermal actuators................................................... 292
Aktor T Accessories and spare parts............................................. 293
Aktor M Electromotive actuators................................................... 294
Aktor M Accessories....................................................................... 297
289
HYDRONIC BALANCING WITH PRESSURE INDEPENDENT CONTROL VALVES
ACTUATORS
2.2 Item no. 106836. 10685.. 1145., 1146., 1143., 1147., 1144606 11312..
106846. 10686.. 11475.., 1148. 1149. 1144608
PN 16 16 16 25 25 16
Connection M30 x 1.5 M30 x 1.5 M30 x 1.5 M30 x 1.5 M30 x 1.5 M30 x 1.5
Closing force [mm] 11.8 11.8 11.8 11.8 11.8
Δp max [bar] 1 5 3 2 4 6 4
Valve stroke [mm] 2.2 3 4 4 2.8 3.5 4 2,8 4 4 2.8
Upper stroke position [mm] ≥14.0 ≥15.8 ≥14.6 ≥15.8 ≥14.6 ≥15.8 ≥15.8 ≥14.6
Lower stroke position [mm] ≤11.3 ≤11.3 ≤11.3 ≤11.3 ≤11.3 ≤11.3
Closing force [N] min...max 90...150 90...150 90...150 90...150 90...150 90...150
Valve characteristic line
290
HYDRONIC BALANCING WITH PRESSURE INDEPENDENT CONTROL VALVES
ACTUATORS
Product family Cocon Large and flanged valves from DN 40 Control valves
Closing force [N] 500/ 500/ 800/ 800/ 800/ 500 2.000
800/ 800/ 1.000/ 1.000/ 1.000
1.000 1.000 1.200 1.200
Valve characteristic
line
291
HYDRONIC BALANCING WITH PRESSURE INDEPENDENT CONTROL VALVES
ACTUATORS
Valve adapter
PU 5
2.2
Description Item No.
Reinforcing cap
293
HYDRONIC BALANCING WITH PRESSURE INDEPENDENT CONTROL VALVES
ACTUATORS
Electromotive actuators are used for heating, tors/collectors (except for item no. 1012710 /
ventilation and air conditioning. Amongst oth- 11), radiant heating ceilings, cooling ceilings
ers, the actuators can be used for room tem- and induction units.
perature control. They can be used, for exam-
ple, with conventional radiators, radiators with Oventrop offers electromotive actuators with
2.2 integrated valve sets, heating circuit distribu- and without communication interfaces.
Electrical emergency control function Additional two point / three point Position feedback Tension Item No.
control
Aktor M two point and three point control, connection thread M 30 x 1.5
Cable* 1.5 m
Description Without valve anti-blocking function
Mode of operation not adjustable
Zero point detection
230 V 1012729
Aktor M two point control, with short operating time (3 s), connection thread M 30 x 1.5
Cable* 1.5 m
Description Without valve anti-blocking function
Mode of operation adjustable
230 V 1012710
24 V 1012711
2.2
Aktor M steady control with 0 - 10 V or two point / three point control, squeeze connection
For two-way valve item no. 11308.. and 16708.. DN 15 to DN 50.
Cable* 1.2 m
Descrip- Automatic valve anti-blocking function
tion With position feedback signal 0 - 10 V
Characteristic line adjustable (linear, equal
percentage)
24 V 1158011
Aktor M steady control with 0(2) - 10 V or three point control, squeeze connection
For Cocon QTR / QFC DN 40 to DN 100.
Description Characteristic line linear
20 mm stroke with adapter
With position feedback signal 0 - 10 V
24 V 1158020
Aktor M steady control with 0(2) - 10 V resp. 0(4) - 20 mA or two point / three point control, squeeze connection
For Cocon QTR / QFC DN 40 to DN 100.
Description 20 mm stroke, spring return and adapter
With position feedback signal 0 - 10 V
Characteristic line linear
Aktor M steady control with 0 - 10 V, 4 - 20 mA or two point / three point control, squeeze connection
For Cocon QFC DN 125 to DN 200 and two-way valves DN 65 to DN 150.
Descrip- Characteristic line adjustable (linear, square-
tion law, equal percentage)
With position feedback signal 0 - 10 V
Aktor M Accessories
Resistor 0 / 4 mA
For Aktor M 0 - 10 V (item no. 1158020).
298
2.3 Connection and control of heating and cooling
devices
299
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
OPTIBAL W6 CONTROL BALL VALVE
BMS GLT Optibal W6 as change-over and control ball valve with Kvs orifices.
Can also be integrated into the building management system (BMS).
A
B
2.3
Kühlen
Heizen
Cooling
Kühlen
Heizen
Cooling
Kühlen
Heizen
300
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
OPTIBAL W6 CONTROL BALL VALVE
Six-way ball valve for switching between cool- Pipe connection DN 15 external thread with
ing and heating in a four pipe system by Eurocone according to EN 16313, DN 20 exter-
means of the Aktor R ST L electromotive rota- nal thread with internal cone.
ry actuator. The six-way ball valve can be used Kvs orifices 0.25 / 0.4 / 0.63 / 1 / 1.6 and 2.5
to control the flow rates via the angle of rota- available as accessories.
tion. In conjunction with kvs orifices, cooling
and heating circuits can be limited independ- Suitable connection fittings see section “Con-
ently of each other. nection technology”.
Body made of dezincification resistant brass.
2.3
2019
DN 15 G 3/4 1132004
DN 20 G1 10 1132006
301
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
OPTIBAL W6 CONTROL BALL VALVE
Aktor R ST L
Rotary actuator for Optibal W6 six-way ball valve. 24 V, proportional control with 0 - 10 V or two point control via
24 V forced control. With position feedback signal 0 - 10 V. Torque: 5 Nm. Angle of rotation: 90°. With manual
adjustment.
302
2.3 Connection and control of heating and cooling
devices
303
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
FLYPASS CONNECTION SETS
oventrop
Flypass 4TZ
Made in Germany
Flypass 4TZ
oventrop
Draining of the system and Draining, venting and Filling and flushing of the Shutting off and draining
appliance side, flushing of the system side appliance side of the appliance side
venting and flushing of the
system side
oventrop
Flypass 4TZ
Made in Germany
304
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
FLYPASS CONNECTION SETS
Connection fitting for shutting off, flushing, tion valves. Basically, all flat-sealing Oventrop
draining and venting the upstream supply and valves of the corresponding nominal sizes with
return pipes or the downstream system com- G 3/4 external thread (DN 15) or G 1 external
ponents, for example fan coil units or cooling thread (DN 20) can be combined with the Fly-
ceiling modules. Convertible to bypass mode. pass 4TZ. The adapter item no. 1149075 (DN
The flow paths can be identified by the handle 15) or 1149076 (DN 20) is required for mount-
shape. ing valves with internal thread.
For combination with other control and func-
2.3
Body material DZR brass Operating temperature -10 up to 120 °C
Shutoff Yes Medium Water
Draining Yes Water-glycol mixture
Position indicator Yes
Flypass 4TZ with internal thread and union nut with sealing ring, flat sealing PN 16, DN 15…20
DN 15 22.00 1149504
DN 20 34.00 1149506
305
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
FLYPASS CONNECTION SETS
Flypass sets
306
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
FLYPASS CONNECTION SETS
Flypass Accessories
Thermal insulation shell made polyurethane rigid foam with polystyrene shell
For Flypass set 1, except for item no. 1149651-54.
For Flypass set 2, except for item no. 1149562-64.
Thermal insulation consisting of two shells for heating and cooling systems. Complies with the German Energy
Saving Ordinance (EnEV) according to appendix 5, table 1, line 5. Building material class B2 according to DIN 4102.
Operating temperature: -10 °C to +120 °C.
Cold insulation: Min. medium temperature 6 °C, shells have to be bonded hermetically. Restricted diffusion tightness
at low medium temperature and at high ambient temperature and/or air humidity.
2.3
Description Item No.
308
2.3 Connection and control of heating and cooling
devices
309
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
TRI-CTR THREE-WAY VALVES
DN 15 R 1/2 10 1130291
DN 20 R 1/2 10 1130292
DN 20 R 3/4 10 1130293
DN 25 R1 10 1130294
DN 40 R1¼ 5 1130295
DN 40 R 1 1/2 5 1130296
DN 50 R2 5 1130298
DN 32 R1¼ 5 1130299
310
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
TRI-CTR THREE-WAY VALVES
Temperature controllers
20 up to 50 2,000 1140561
40 up to 70 2,000 1140562
50 up to 80 2,000 1140563
70 up to 100 2,000 1140564
20 up to 50 5,000 1140571
40 up to 70 5,000 1140572
70 up to 100 5,000 1140574
Immersion sleeve
Two-way valve for use in central heating and centre spigot is closed with a blind flange.
cooling systems with closed circuits. The valve can be used as a three-way valve
DN 15 to DN 50: metal to metal seal between (mixing and diverting) when the blind flange is
cone and seat, DN 65 to DN 150: soft sealing removed.
with EPDM seal beween cone and seat. The
DN 15 2.50 1130845
DN 20 6.30 1130846
DN 25 10.00 1130847
DN 32 16.00 1130848
DN 40 25.00 1130849
DN 50 35.00 1130850
DN 65 63.00 1130851
DN 80 100.00 1130852
DN 100 160.00 1130853
DN 125 220.00 1130854
DN 150 320.00 1130855
DN 15 1.60 1130865
DN 20 4.00 1130866
DN 15 1.00 1130875
Flanges PN 16 with hole circles according to ANSI class 150, 2 1/2…6 inch (DN 65…150)
313
CONNECTION AND CONTROL OF HEATING AND COOLING DEVICES
HYCOCON CONTROL VALVES
Hycocon ETZ with external thread PN 16, DN 15…20, without union nuts
Flat sealing, without union nut and sealing ring.
2.3
Hycocon HTZ with external thread PN 16, DN 15…20, without union nuts
Flat sealing, without union nut and sealing ring.
PU 10
PU 10
PU 10
316
2.4 Differential pressure measurement and
verification of water quantities
317
2.4 Differential pressure measurement and verification
of water quantities
319
DIFFERENTIAL PRESSURE MEASUREMENT AND VERIFICATION OF WATER QUANTITIES
OV MEASURING SYSTEM
System for flow measurement at valves and After entering the valve data and the desired
for regulation of heating and cooling systems. flow rate, a calculation of the presetting for
For use with all Oventrop products equipped Oventrop double regulating and commission-
with Classic or Eco measuring valves or Hy- ing valves is possible. The permanent record-
droPort auxiliary valves: HydroControl, Hydro- ing of differential pressure and flow rate is also
Com, Cocon, Hycocon and measuring orifices. possible. The optional connection of two tem-
With interfaces for communication with com- perature sensors, for example for supply and
mercially available smartphones and tablets return, enables direct performance calculation.
using the Oventrop app for convenient meas- The OV-DMC 3 is supplied in a sturdy case
uring and logging. The data determined with all necessary adapters for connection to
with the OVplan and OVselect calculation pro- Oventrop valves. Smartphone or tablet are not
grammes can be accessed. included in the scope of delivery.
Item No.
1069278
320
DIFFERENTIAL PRESSURE MEASUREMENT AND VERIFICATION OF WATER QUANTITIES
OV MEASURING SYSTEM
PU 5
2.4
Item No.
1069180
321
DIFFERENTIAL PRESSURE MEASUREMENT AND VERIFICATION OF WATER QUANTITIES
OV MEASURING SYSTEM
2.4
PU 50
Measuring adapter with quick-coupling technique for drain and fill tool 1060297 °
1 measuring valve+ 1 fill and drain ball valve with quick-coupling technique 1060391
2.4
2.4
324
DIFFERENTIAL PRESSURE MEASUREMENT AND VERIFICATION OF WATER QUANTITIES
MEASURING ORIFICES
Measuring orifices
Measuring orifices PN 16 / PN 25 with threads can be read directly independently of the pre-
or for installation between flanges. Supplied set values of the upstream or downstream
with Classic measuring valves. For flow deter- valve by means of the OV-DMC 3 measuring
mination in central heating and cooling sys- system.
tems. The flow rate is determined by measur- The measuring orifices for installation be-
ing the differential pressure across the meas- tween flanges can be combined with all valves
uring orifice. Modification of the flow values with flanges according to EN 1092.
2.4
325
DIFFERENTIAL PRESSURE MEASUREMENT AND VERIFICATION OF WATER QUANTITIES
MEASURING ORIFICES
Measuring orifices for flanges according to EN 1092 PN 16, DN 65…1.000, made of stainless steel
DN 65 102.00 1060751
DN 80 120.00 1060752
DN 100 234.00 1060753
DN 125 335.00 1060754
DN 150 522.00 1060755
DN 200 780.00 1060756
DN 250 1,197.00 1060757
DN 300 1,810.00 1060758
DN 350 2,050.00 1060759
DN 400 2,650.00 1060760
2.4
DN 450 3,400.00 1060761 °
DN 500 4,200.00 1060762
DN 600 6,250.00 1060763
DN 700 10,690.00 1060764
DN 800 14,000.00 1060765
DN 900 17,577.00 1060766 °
DN 1000 22,540.00 1060767 °
Measuring orifices for flanges according to EN 1092 PN 25, DN 100…600, made of stainless steel
Measuring orifices for flanges according to EN 1092 PN 16, DN 65…300, made of cast iron
DN 65 93.00 1060771
DN 80 126.00 1060772
DN 100 244.00 1060773
DN 125 415.00 1060774
DN 150 540.00 1060775
DN 200 1,010.00 1060776
DN 250 1,450.00 1060777
DN 300 2,400.00 1060778
2.4
327
2.5 Shutoff valves and other pipeline valves,
connection technology
328
2.5 Shutoff valves and other pipeline valves, connection
technology
329
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
Ball surface hard chrome plated. Anthracite ex- red replaceable cover plug for riser identifica-
tended plastic handle for easy insulation. With tion.
330
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
Optibal with internal thread PN 16, DN 15…32, with drain ball valve
2.5
DN 15 15 mm 22.00 10 1077162
DN 15 18 mm 22.00 10 1077163
DN 20 22 mm 43.00 10 1077164
DN 25 28 mm 67.00 10 1077165
DN 32 35 mm 99.00 5 1077166
331
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
PU 10
2.5
332
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
DN 8 G¼ 5.60 10 1076002
DN 10 G 3/8 8.80 10 1076003
DN 15 G 1/2 22.00 10 1076004
DN 20 G 3/4 43.00 10 1076006
DN 25 G1 67.00 10 1076008
DN 32 G1¼ 99.00 8 1076010
DN 40 G 1 1/2 143.00 6 1076012
DN 50 G2 254.00 4 1076016
DN 65 G 2 1/2 470.00 2 1076020
DN 80 G3 720.00 50 1076024
DN 100 G4 1,120.00 1076032
333
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
334
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
Ball surface hard chrome plated. Anthracite ex- red replaceable cover plug for riser identifica-
tended plastic handle for easy insulation. With tion.
Optibal P with internal thread and pump flange PN 10, with check valve
2.5
To prevent gravity circulation in various heating systems when the pump is switched off.
For direct connection to the circulation pump. Opening pressure 20 mbar.
PU 10
Optibal P with internal thread and pump flange, without check valve
PU 10
335
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
DN 20 22 mm 9.50 10 1078760 °
DN 25 28 mm 17.00 10 1078761 °
DN 32 35 mm 35.00 5 1078762 °
Optibal with weldable tailpipe and external thread with cap, DN 15…32, extended handle made of plastic
2.5
Operating temperature 2 up to 120 °C PU 5
Optibal with weldable tailpipe and external thread with cap, DN 15…32, lever made of aluminium
DN 15 20.5 mm 1065604
DN 20 26 mm 1065606
DN 25 33 mm 1065608
DN 32 42.5 mm 1065610
337
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
DN 15 20.5 mm 1065504
DN 20 26 mm 1065506
DN 25 33 mm 1065508
DN 32 42.5 mm 1065510
2.5
338
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
Ball valve DZR with internal thread PN 30, DN 15…50, lever made of galvanised steel with plastic coating
2.5
Ball valve DZR with internal thread PN 30, DN 15…20, T-handle made of aluminium
Ball valve DZR with internal thread PN 30, DN 15…50, extended handle made of plastic
339
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
DN 20 G1 1351705
340
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
Optibal Accessories
DN 10 and DN 15 1078092
DN 20 1078093
DN 25 1078094
DN 32 250 1078095
DN 40 250 1078096
2.5
DN 50 1078097
DN 25 1078194
DN 32 250 1078195
Up to DN 15 1076071
For DN 20 and DN 25 1076072
For DN 32 to DN 50 1076073
341
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
Spindle extension
Made of brass, with rotatable plastic sleeve. For retrofitting of Optibal brass ball valves, except for item no. 10787..
By sealing the rotatable plastic sleeve against the insulation in cooling systems, moisture cannot reach the pipework
via the spindle extension. Only one extension can be used at a time.
To avoid condensation on the handle, the handle of ball valves with T-handle or lever must also be insulated, e.g. by
covering the shaft and handle with elastic pipe insulation.
PU 10
342
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OPTIBAL BALL VALVES
For DN 15 1079254
For DN 20 and DN 25 1079255
For DN 32 to DN 50 1079256
DN 15 G 3/4 1066904
DN 20 G1 1066906 2.5
DN 25 G1¼ 1066908
DN 32 G 1 3/4 1066910
343
2.5 Shutoff valves and other pipeline valves, connection
technology
2.5
344
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
FILL AND DRAIN COCKS
For filling and draining of heating and cooling With cap. Handle with stop. Hose connections,
systems, boilers, radiators and pipework. if included, with soft seal.
Shutoff Yes
2.5
Optiflex with external thread PN 16 and plastic hose connection, without individual packaging
Self sealing with counter nut.
Body material Brass Installation location Supply or return
Operating temperature 0 up to 120 °C PU 50
Medium Water
Water-glycol mixture
345
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
FILL AND DRAIN COCKS
DN 25 G1 10 1033308
DN 20 G 3/4 25 1033316
DN 15 G 1/2 50 1034315
DN 10 G 3/8 1033413
DN 15 G 1/2 1033414
DN 15 Rp 1/2 1033914 °
DN 10 G 3/8 1032403
DN 15 G 1/2 1032404
DN 15 G 1/2 1033152
347
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
FILL AND DRAIN COCKS
Fill and drain cock with external thread PN 16, DN 10...25, heavy model
2.5
Based on DIN 3848. For liquids, steam and treated heating water, e.g. district heating. Can be used up to 180 °C for
short periods.
Readjustment of the fill and drain ball valves to maintain tightness during operation may be necessary, e.g. during
operation in the low-temperature range, extreme temperature changes or use of penetrating additives in heat
transfer liquids.
Body material Bronze Operating temperature 0 up to 150 °C
Shutoff Yes Medium Water
Draining Yes Water-glycol mixture
Measuring connection No Installation location Supply or return
DN 10 R 3/8 50 1032003
DN 15 R 1/2 50 1032004
DN 20 R 3/4 25 1032006
DN 25 R1 10 1032008
Drain and vent valve with external thread PN 16, PN 16, DN 8…10, with metal seal
DN 8 G¼ 1038002 °
DN 10 G 3/8 1038003 °
Hose connection for fill and drain ball valve, heavy model
Cap with sealing washer and fixing loop for fill and drain cock, heavy model
Item no. 1034052 also suitable for Optiflex DN 10.
DN 10 G 1/2 50 1034003
DN 15 G 3/4 50 1034052
DN 20 G1 25 1034053
DN 25 G1¼ 1034054
Square spanner for fill and drain ball valve, heavy pattern
Handle for fill and drain ball valve, item no. 103240.
PU 10
Anthracite 1033091 °
2.5
351
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
SHUTOFF VALVES
DN 40 107.00 1045049
DN 50 250.00 1045050
DN 65 430.00 40 1045051
DN 80 790.00 21 1045052
DN 100 1,250.00 21 1045053
DN 125 1,960.00 15 1045054
2.5
DN 150 2,790.00 10 1045055
DN 200 2,880.00 6 1045056
DN 250 4,306.00 4 1045057
DN 300 6,380.00 2 1045058
DN 40 120.00 1045149 °
DN 50 270.00 1045150 °
DN 65 470.00 1045151 °
DN 80 900.00 1045152 °
DN 100 1,600.00 1045153 °
DN 125 2,150.00 1045154 °
DN 150 3,680.00 3 1045155 °
DN 200 - 1045156 °
DN 250 - 1045157 °
DN 300 - 1045158 °
Shutoff valves
Y-pattern valve with internal thread PN 25, DN 10...50, with drain valve
DN 8 Rp ¼ 1.45 10 1052102 °
DN 10 Rp 3/8 2.10 10 1052103 °
DN 15 Rp 1/2 3.70 10 1052104 °
DN 20 Rp 3/4 6.40 10 1052106 °
DN 25 Rp 1 9.80 10 1052108 °
DN 32 Rp 1 ¼ 15.80 5 1052110 °
DN 40 Rp 1 1/2 22.50 5 1052112 °
DN 50 Rp 2 32.60 5 1052116 °
DN 15 20.5 mm 1065004
DN 20 26 mm 1065006
DN 25 33 mm 1065008
DN 32 42.5 mm 1065010
Drain valve with weldable tailpipe and external thread with cap PN 25, DN 15...32
DN 15 PN 10 1110104
DN 15 PN 25 1110174
DN 15 PN 25 1110204
DN 15 PN 25 1110504
356
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
SHUTOFF VALVES
Pressure gauge shutoff valve with clamping sleeve and spigot, PN 250
For connecting pressure measuring devices and pressure gauges to systems. Application: Liquids, gases and vapours
to which the materials of the valves are resistant.
Body, clamping sleeve, union nut and, if applicable, test spigot or flange made of brass. Spindle and vent screw made
of stainless steel, seal packing made of PTFE, handwheel made of plastic.
DIN 16270-A-20 Ms, brass / stainless steel, without test connection 1115004
DIN 16271-A-20 Ms, brass / stainless steel, with test spigot M 20 x 1,5 1115104
Similar to DIN 16271-A-20 Ms, brass / stainless steel, with test flange 25 x 60 mm 1115204 °
Pressure gauge shutoff valve with clamping sleeve and spigot, PN 250
For connecting pressure measuring devices and pressure gauges to systems. Application: Liquids, gases and vapours
2.5
to which the materials of the valves are resistant.
Body, clamping sleeve, union nut and, if applicable, test spigot or flange made of steel. Spindle and vent screw made
of stainless steel, seal packing made of graphite, handwheel made of plastic.
DIN 16270-A-10 St, steel / stainless steel, without test connection 1116004
Similar to DIN 16271-A-10 St, steel / stainless steel, with test flange 25 x 60 mm 1116204 °
Vent valve PN 25
PU 25
DN 15 1067004
2.5
PU 10
Steel welding nipple with union nut for pressure gauge shutoff valves 50 1117204 °
Cu sealing ring DIN 16528 for pressure gauge shutoff valves 1905552
PU 100
DN 10 and DN 15 1900051
DN 20 and DN 25 1900052
DN 32 and DN 40 1900053
DN 50 1900054
DN 65 1900055
DN 80 and DN 100 1900056
DN 15 1065904 °
DN 20 1065906 °
DN 25 1065908 °
DN 32 1065910 °
DN 15 G 3/4 1066904
DN 20 G1 1066906
DN 25 G1¼ 1066908
DN 32 G 1 3/4 1066910
360
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Butterfly valves
The lugged and wafer butterfly valves are de- closed circuits. For operation with non-aggres-
signed for installation between two flanges ac- sive, harmless media , e.g. water or water-gly-
cording to EN 1092-2. The neck is extended for col mixtures according to VDI 2035 / ÖNORM
insulation purposes. Higher nominal sizes are 5195.
available on request. Body made of nodular cast iron, spindle and
For central heating and cooling systems with disc made of stainless steel.
DN 50 147.00 1048450
DN 65 290.00 1048451
DN 80 450.00 160 1048452
DN 100 730.00 1048453
DN 125 1,260.00 1048454
DN 150 1,990.00 50 1048455
DN 200 4,390.00 1048456
361
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
DN 50 147.00 1046450
DN 65 290.00 1046451
DN 80 450.00 1046452
DN 100 730.00 1046453
DN 125 1,260.00 1046454
DN 150 1,990.00 1046455
DN 200 4,390.00 1046456
362
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Lever
For item no. 10484.. and 10464..
For DN 50 to DN 80 1048491
For DN 100 to DN 150 1048492
For DN 200 1048493
363
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Backflow preventers for horizontal and vertical no. 10271.. For central heating and cooling sys-
installation. Valve plug spring-loaded. Opening tems with closed circuits. For operation with
pressure 40 mbar. The piston type spring as- non-aggressive, harmless media, e.g. water or
sisted check valves DN 10 and DN 20 are suit- water-glycol mixtures according to VDI 2035 /
able for Oventrop compression fittings item ÖNORM 5195.
2.5
Piston type spring assisted check valve with internal thread PN 25, DN 10…50, FKM seal
Piston type spring assisted check valve with internal thread PN 25, DN 10…50, EPDM seal
Also for systems with open circuits that are operated with water. Materials suitable for potable water.
Operating temperature -10 up to 150 °C Certification WRAS
364
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Backflow preventers for horizontal and vertical sive, harmless media, e.g. water or water-gly-
installation in risers, flap opening upwards. col mixtures according to VDI 2035 / ÖNORM
For central heating and cooling systems with 5195.
closed circuits. For operation with non-aggres-
Medium Water
Water-glycol mixture
DN 40 85.00 1073049
DN 50 132.00 20 1073050
DN 65 326.00 50 1073051
DN 80 490.00 20 1073052
DN 100 770.00 1073053
DN 125 1,020.00 1073054
DN 150 1,700.00 1073055
DN 200 2,410.00 1073056
DN 250 3,870.00 4 1073057
DN 300 5,670.00 2 1073058
365
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
DN 40 22.20 1072549
DN 50 54.00 1072550
DN 65 75.00 1072551
DN 80 112.00 1072552
DN 100 172.00 1072553
DN 125 342.00 1072554
DN 150 490.00 1072555
DN 200 1,128.00 1072556
DN 250 1,500.00 1072557
DN 300 1,850.00 1072558
DN 350 2,700.00 1072559
DN 400 3,500.00 1072560
DN 500 5,200.00 1072561
2.5
DN 50 55.00 1072650
DN 65 82.00 1072651
DN 80 115.00 1072652
DN 100 236.00 1072653
DN 125 500.00 1072654
DN 150 700.00 1072655
DN 200 1,100.00 1072656
DN 250 2,000.00 1072657
DN 300 3,300.00 1072658
DN 350 3,950.00 1072659
DN 400 5,000.00 1072660
DN 450 6,550.00 1072661
DN 500 8,250.00 1072662
DN 600 12,600.00 1072663
366
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Strainer
For central heating and cooling systems with col mixtures according to VDI 2035 / ÖNORM
closed circuits. For operation with non-aggres- 5195.
sive, harmless media , e.g. water or water-gly-
Medium Water
Water-glycol mixture
2.5
367
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
DN 15 20.5 mm 1068004
DN 20 26 mm 1068006
DN 25 33 mm 1068008
DN 32 42.5 mm 1068010
2.5
Strainer with internal thread PN 25, DN 8…80, mesh size 250 µm
Wire basket made of stainless chromium nickel steel.
DN 8 - DN 50: Body made of bronze, cover made of brass
DN 65 and DN 80: Body and cover made of brass
Operating -10 up to 150 °C
temperature
Material re- Mineral, heating and hydraulic oils
sistance Fuels
Water vapour
Air
Harmless, non-aggressive gases
Not suitable for gaseous fluids group
1 according to directive 2014/68/EU
DN 8 G¼ 1.40 10 1121002
DN 10 Rp 3/8 1.60 10 1121003
DN 15 Rp 1/2 3.40 10 1121004
DN 20 Rp 3/4 6.90 10 1121006
DN 25 G1 10.90 10 1121008
DN 32 G1¼ 20.70 5 1121010
DN 40 G 1 1/2 27.40 5 1121012
DN 50 G2 47.30 5 1121016
DN 65 G 1 1/2 82.10 1121020
DN 80 G3 102.00 1121024
368
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Strainer with flanges according to EN 1092-2 PN 16, DN 15…600, mesh size 1…3 mm
Body: DN 15 to DN 300 made of cast iron, DN 350 to 600 made of nodular cast iron. Wire basket made of stainless
steel, asbestos free seal.
Screen aperture width:
– DN 15 to DN 32: 1.0 mm
– DN 40 to DN 150: 1.5 mm
– DN 200 to DN 300: 2.0 mm
– DN 350 to DN 600: 3.0 mm
Operating temperature 0 up to 120 °C
DN 15 7.00 1122045
DN 20 10.00 1122046
DN 25 15.00 1122047
DN 32 21.00 1122048
DN 40 39.00 1122049
DN 50 60.00 1122050
DN 65 105.00 50 1122051
DN 80 140.00 20 1122052
2.5
DN 100 225.00 20 1122053
DN 125 340.00 1122054
DN 150 405.00 1122055
DN 200 715.00 5 1122056
DN 250 1,355.00 4 1122057
DN 300 1,890.00 2 1122058
DN 350 2,970.00 1122059
DN 400 4,150.00 1122060
DN 450 5,540.00 1122061
DN 500 6,850.00 1122062
DN 600 9,280.00 1122063
369
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Wire basket, mesh size 600 µm, for item no. 11200..
Mesh size 0.6 mm, 100 meshes / cm².
DN 8 and DN 10 1123003
DN 15 1123004
DN 20 1123006
DN 25 1123008
DN 32 1123010
DN 40 1123012
DN 50 100 1123016
DN 65 1123020
DN 80 1123024
2.5
Wire basket, mesh size 600 µm, for item no. 10680..
Mesh size 0.6 mm, 100 meshes/ cm².
PU 10
DN 15 1068804
DN 20 1068806
DN 25 1068808
DN 32 1068810
DN 8 and DN 10 1123103
DN 15 1123104
DN 20 1123106
DN 25 1123108
DN 32 1123110
DN 40 1123112
DN 50 1123116
DN 65 1123120
DN 80 1123124
370
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
– DN 15 to DN 32: 1.0 mm
– DN 40 to DN 150: 1.5mm
– DN 200 to DN 300: 2.0 mm
– DN 350 to DN 600: 3.0 mm
DN 15 and DN 20 1122085
DN 25 1122087
DN 32 1122088
DN 40 1122089
DN 50 1122090
DN 65 1122091
DN 80 1122092
DN 100 1122093
DN 125 1122094
DN 150 1122095
DN 200 1122096
DN 250 1122097 2.5
DN 300 1122098
DN 350 1122159
DN 400 1122160
DN 450 1122161
DN 500 1122162
DN 600 1122163
371
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Dirt separators
Sludge separators continuously remove small- closed circuits. For operation with non-aggres-
est dirt particles without significantly increas- sive, harmless fuids, e.g. water or water-gly-
ing the flow resistance. A strong magnet re- col mixtures according to VDI 2035 / ÖNORM
tains magnetite. When the magnet is pulled 5195.
out, the magnetic particles fall into the sump Body of the models with internal thread made
and can be rinsed out via a ball valve without of brass, body of the models with flanges
interrupting operation. made of steel.
For central heating and cooling systems with
Sludge separator with internal thread PN 16, DN 20...40, for horizontal installation
2.5
Body material Brass
Sludge separator with internal thread PN 16, DN 20...25, for vertical installation
372
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
DN 50 72.00 1124550
DN 65 121.00 1124551
DN 80 158.00 1124552
DN 100 244.00 1124553
DN 125 351.00 1124554
DN 150 487.00 1124555
DN 200 780.00 1124556
DN 250 1,185.00 1124557
DN 300 1,696.00 1124558
Sludge separator with flanges PN 16 with hole circles according to ANSI class 150, 2...12 inch (DN 50...300)
DN 50 - 2 72.00 1124650
DN 65 - 2 1/2 121.00 1124651
DN 80 - 3 158.00 1124652
DN 100 - 4 244.00 1124653
DN 125 - 5 351.00 1124654
DN 150 - 6 487.00 1124655
DN 200 - 8 780.00 1124656
DN 250 - 10 1,185.00 1124657
DN 300 - 12 1,696.00 1124658
373
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
OTHER PIPELINE VALVES
Air vents
DN 10 G 3/8 1088303
DN 15 G 1/2 1088304
DN 20 G 3/4 1088306
2.5
Air vent with angle connection PN 10, nickel plated, without automatic shutoff device
DN 15 1088404
DN 10 1088203
374
2.5 Shutoff valves and other pipeline valves, connection
technology
375
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
CONNECTION TECHNOLOGY
Suitable for:
2.5
Nominal size Connection size Item No.
DN 10 G 3/8 x 10 mm 1027151
DN 10 G 3/8 x 12 mm 1027152
DN 15 G 1/2 x 12 mm 1027153 °
DN 15 G 1/2 x 15 mm 1027155 °
DN 20 G 3/4 x 18 mm 1027157
DN 20 G 3/4 x 22 mm 1027158
– HydroControl V, D and A,
– Hycoflow VTB, Cocon QTZ PN 16,
– Cocon QTZ PN 25 (max. operating pressure 16 bar),
– Optibal W6,
– Strainers PN 25 (11410..) (max. operating pressure 16 bar)
DN 10 R 3/8 10 1140791 °
DN 15 R 1/2 10 1140792 °
DN 20 R 3/4 10 1140793 °
DN 25 R1 10 1140794 ° 2.5
DN 32 R1¼ 5 1140795 °
DN 40 R 1 1/2 5 1140796 °
DN 50 R2 5 1140797 °
DN 15 18 mm 10 1140691 °
DN 15 15 mm 10 1140692 °
DN 20 18 mm 10 1140693 °
DN 20 22 mm 10 1140694 °
DN 25 28 mm 10 1140695 °
DN 32 35 mm 5 1140696 °
DN 40 42 mm 5 1140697 °
DN 50 54 mm 5 1140698 °
DN 10 10 1140591 °
DN 15 10 1140592 °
DN 20 10 1140593 °
DN 25 10 1140594 °
DN 32 5 1140595 °
DN 40 5 1140596 °
DN 50 5 1140597 °
DN 15 Rp 1/2 10 1140892
DN 20 Rp 3/4 10 1140893
DN 25 Rp 1 10 1140894
DN 32 Rp 1 ¼ 5 1140895
2.5
378
SHUTOFF VALVES AND OTHER PIPELINE VALVES, CONNECTION TECHNOLOGY
CONNECTION TECHNOLOGY
DN 10 R 3/8 10 1140281
DN 15 R 1/2 10 1140282
DN 20 R 3/4 10 1140284
DN 25 R1 10 1140285
DN 32 R1¼ 5 1140286
DN 15 12 mm 1140181 °
DN 15 15 mm 1140182 °
DN 20 18 mm 1140183 °
DN 20 22 mm 1140184 °
DN 15 10 mm 1140380 °
DN 15 12 mm 1140381 °
DN 15 15 mm 1140382 °
DN 20 18 mm 1140383 °
DN 20 22 mm 1140384 °
DN 15 Rp 1/2 10 1141292
DN 20 Rp 3/4 10 1141293
DN 25 Rp 1 10 1141294
DN 32 Rp 1 ¼ 5 1141295
DN 10 R 3/8 10 1061491
DN 15 R 1/2 10 1061492
DN 20 R 3/4 10 1061493
DN 25 R1 10 1061494
DN 32 R1¼ 5 1061495
2.5
DN 40 R 1 1/2 5 1061496
DN 50 R2 5 1061497
DN 15 18 mm 10 1061091 °
DN 15 15 mm 10 1061092 °
DN 20 18 mm 10 1061093 °
DN 20 22 mm 10 1061094 °
DN 25 28 mm 10 1061095 °
DN 32 35 mm 5 1061096 °
DN 40 42 mm 5 1061097 °
DN 50 54 mm 5 1061098 °
DN 10 10 1060591 °
DN 15 10 1060592
DN 20 10 1060593
DN 25 10 1060594
DN 32 5 1060595
DN 40 5 1060596
DN 50 5 1060597
DN 15 Rp 1/2 10 1061392 °
DN 20 Rp 3/4 10 1061393 °
DN 25 Rp 1 10 1061394 °
DN 32 Rp 1 ¼ 5 1061395 °
2.5
Individual parts
Inserts
Inserts allow for the use of flat sealing tailpipes or connection sets with conically sealing valves.
Adapter
One side external thread (valve connection), one side flat sealing external thread. For connecting valves with internal
2.5 thread to the Flypass 4TZ. For this purpose, the adapter must be screwed into the internally threaded connection of
the valve.
PU 10
DN 15 1149075 °
DN 20 1149076 °
Double nipple
Both sides flat sealing external thread. For connecting flat sealing pipes or valves with union nut directly to the
Flypass 4TZ.
PU 10
DN 15 1149070
DN 20 1149071
3
3.1 Stations for heating circuit and cooling circuit
connection
386
3.1 Stations for heating circuit and cooling circuit
connection
387
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Regumat S-130 DN 20
With universal thermal insulation of modular construction.
Nominal size DN 20 Centre distance 100 mm
Connection heating circuit G 1 external thread, Universal thermal insulation Yes
flat sealing Wall bracket Yes
Connection heat generator G 1 external thread flat Pump ball valve No
sealing
Pump ball valve with drain/flush No
Pump length 130 mm valve
Length 190 mm Insert for pressure relief device No
Width 230 mm kvs 5.80
Height 360 mm Max. operating temperature 95 °C
Length product assembly 315 mm
388
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Regumat S-130 DN 25
With thermal insulation.
Nominal size DN 25 Centre distance 125 mm
Connection heating circuit G 1 1/2 external thread, Universal thermal insulation No
flat sealing Wall bracket No
Connection heat generator G 1 1/2 external thread Pump ball valve No
flat sealing
Pump ball valve with drain/flush No
Pump length 130 mm valve
Length 197 mm Insert for pressure relief device Extendable
Width 248 mm kvs 7.40
Height 364 mm Max. operating temperature 85 °C
Length product assembly 311 mm
390
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
391
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Regumat S-220 DN 40
With universal thermal insulation of modular construction.
Nominal size DN 40 Universal thermal insulation Yes
Connection heating circuit G 2 internal thread Wall bracket No
Connection heat generator G 2 external thread Pump ball valve Yes
flat sealing Pump ball valve with drain/flush Yes
Pump length 220 mm valve
Length 340 mm Insert for pressure relief device No
Width 428 mm kvs 29.30
Height 850 mm Max. operating temperature 95 °C
Length product assembly 797 mm PU 2
Centre distance 180 mm
Regumat S-280 DN 50
With universal thermal insulation of modular construction.
Nominal size DN 50 Universal thermal insulation Yes
3.1
Connection heating circuit G 2 internal thread Wall bracket No
Connection heat generator G 2 external thread Pump ball valve Yes
flat sealing Pump ball valve with drain/flush Yes
Pump length 280 mm valve
Length 340 mm Insert for pressure relief device No
Width 428 mm kvs 29.30
Height 850 mm Max. operating temperature 95 °C
Length product assembly 797 mm PU 2
Centre distance 180 mm
392
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Regumat M3-130 DN 20
With universal thermal insulation of modular construction.
Nominal size DN 20 Centre distance 100 mm
Connection heating circuit G 1 external thread, Universal thermal insulation Yes
flat sealing Wall bracket Yes
Connection heat generator G 1 external thread flat Pump ball valve No
sealing
Pump ball valve with drain/flush No
Pump length 130 mm valve
Length 190 mm Insert for pressure relief device No
Width 230 mm kvs 5.10
Height 360 mm Max. operating temperature 95 °C
Length product assembly 315 mm
393
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Regumat M3-130 DN 25
With thermal insulation.
Nominal size DN 25 Centre distance 125 mm
Connection heating circuit G 1 1/2 external thread, Universal thermal insulation No
flat sealing Wall bracket No
Connection heat generator G 1 1/2 external thread Pump ball valve No
flat sealing
Pump ball valve with drain/flush No
Pump length 130 mm valve
Length 197 mm Insert for pressure relief device Extendable
Width 248 mm kvs 4.30
Height 364 mm Max. operating temperature 85 °C
Length product assembly 311 mm
395
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
396
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Regumat M3-220 DN 40
With universal thermal insulation of modular construction.
Nominal size DN 40 Universal thermal insulation Yes
Connection heating circuit G 2 internal thread Wall bracket No
Connection heat generator G 2 external thread Pump ball valve Yes
flat sealing Pump ball valve with drain/flush Yes
Pump length 220 mm valve
Length 340 mm Insert for pressure relief device No
Width 428 mm kvs 24.80
Height 850 mm Max. operating temperature 95 °C
Length product assembly 797 mm PU 2
Centre distance 180 mm
Regumat M3-280 DN 50
With universal thermal insulation of modular construction.
Nominal size DN 50 Universal thermal insulation Yes
3.1
Connection heating circuit G 2 internal thread Wall bracket No
Connection heat generator G 2 external thread Pump ball valve Yes
flat sealing Pump ball valve with drain/flush Yes
Pump length 280 mm valve
Length 340 mm Insert for pressure relief device No
Width 428 mm kvs 24.80
Height 850 mm Max. operating temperature 95 °C
Length product assembly 797 mm PU 2
Centre distance 180 mm
397
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Wall bracket
For Regumat S-180 DN 25 with pump ball valve (manufactured until 2015) 1350443
For Regumat M3/M4-180 DN 25 with pump ball valve (manufactured until 2015) 1350444
For Regumat S/M3-180 DN 25 with pump ball valve (manufactured from 2015) 1352250
3.1
Plug
For heat meter installation set (manufactured until 2015), M 10 x 1.0 1350490
Adapter
For heat meter installation set, M 10 x 1 external thread x M 10 x 1 internal thread x Ø 5.6 1352258
For heat meter installation set, M 10 x 1 external thread x M 12 x 1.5 external thread x Ø 6.2 1352259
398
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Spacer
Check valve
For Regumat S (manufactured from 2015), with union nuts and seals 1357087
Installation relay
3.1
For Regumat-180 DN 25 (manufactured from 2015), with Regtronic RH and controller bracket 1357290
399
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
For Regumat-180 DN 25 with pump ball valve (manufactured until 2015) 1356097
For Regumat-180 DN 25 without pump ball valve (manufactured until 2015) 1356098
For Regumat-180 DN 25 (manufactured from 2015), with expanded metal 1357096
400
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Replacement thermometer
3.1
For Regumat DN 25 with pump ball valve (manufactured from 2015) 1357089
For Regumat M3 DN 25 (manufactured until 2015), without manually adustable bypass 1350271
For Regumat M3 DN 25 (manufactured until 2015), with manually adustable bypass 1350281
For Regumat M3 DN 20 1351704
For Regumat M3 DN 32 (manufactured from 2013) 1355299
For Regumat M3 DN 25 (manufactured from 2015) 1357092
For manual adjustment of the three- and four-way mixing valve 1651500
Replacement plug
3.1
For three-way mixing valve with manually adjustable bypass, for closing the bypass channel 1350292
For three-way mixing valve DN 25 (manufactured until 2015), with seal set 1350285
For four-way mixing valve DN 25, for Lineg actuators (without adapter), with seal set 30 1350294
For four-way mixing valve DN 25, for ESBE actuators (without adapter), with seal set 30 1350295
For three-way mixing valve DN 25 (manufactured from 2015) 1357095
402
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Replacement adapter
Replacement actuator
For Regumat M3 DN 20/25/32, 24 V (0-10 V), operating time 140 s, torque 5 Nm 1350951
For Regumat M3 DN 20/25/32, 24 V (three point), operating time 140 s, torque 5 Nm 1350952
For Regumat M3 DN 20/25/32, 230 V (three point), operating time 140 s, torque 5 Nm 1350953
For Regumat M3 DN 32 plus/40/50, 230 V (three point), operating time 140 s, torque 15 Nm 1350956
For Regumat M3 DN 32 plus/40/50, 24 V (0-10 V), operating time 140 s, torque 10 Nm 1350958
For Regumat M3 DN 20/25/32, 230 V, operating time 140 s, torque 5 Nm, with fixed flow tempera-
1351055
ture value control
For Regumat M3 DN 25 (manufactured from 2015), 230 V (three point), operating time 140 s,
1357093
torque 5 Nm, with mounting plate and adapter
For Regumat M3 DN 20/25/32, 230 V (three point), operating time 35 s, torque 5 Nm 1361098 3.1
403
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
For the connection of a thermally controlled two thermometers integrated in the handles
heating circuit. The stations are used for flow to display the flow and return temperatures, a
temperature control and limitation in com- check valve to prevent incorrect circulation, a
bined radiator/surface heating systems. They three-way mixing valve with temperature con-
include all components which are necessary troller and a thermal insulation.
for the connection of heat generators, pumps
and pipework. The stations enable the heating The Regumat stations are characterised by a
circuit to be shut off on the supply and return time and space saving installation of the boil-
sides. The check valve in the return pipe pre- ers to the pipework systems. A high degree
vents incorrect circulation. of functional reliability is ensured by mainte-
nance-free components and high-quality ma-
The stations consist of a shutoff device with terials. The stations can be modularly exten-
two ball valves to shut off the heating circuit, ded with various accessories.
Regumat F-130 DN 25
With thermal insulation.
Pump length 130 mm Wall bracket No
Optional supply pipe change No Pump ball valve No
Length 197 mm Temperature control Thermostatic
Height 364 mm Control range 20 up to 50 °C
Length product assembly 312 mm kvs 2.20
Actuator No Max. operating temperature 85 °C
Universal thermal insulation No
Regumat F-180 DN 25 with pump ball valve and without temperature controller
With universal thermal insulation of modular construction.
Pump length 180 mm Wall bracket No
Optional supply pipe change No Pump ball valve Yes
Length 200 mm Temperature control Thermostatic
Height 512 mm Control range 20 up to 50 °C 3.1
Length product assembly 460 mm kvs 2.20
Actuator No Max. operating temperature 95 °C
Universal thermal insulation Yes
Regumat F-180 DN 25
With universal thermal insulation of modular construction.
Pump length 180 mm Wall bracket No
Optional supply pipe change No Pump ball valve No
Length 200 mm Temperature control Thermostatic
Height 512 mm Control range 20 up to 50 °C
Length product assembly 361 mm kvs 2.20
Actuator No Max. operating temperature 95 °C
Universal thermal insulation Yes
405
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Regumat FR-180 DN 25
With universal thermal insulation of modular construction. Suitable for open vented surface heating systems.
Pump length 180 mm Wall bracket No
Optional supply pipe change No Pump ball valve No
Length 200 mm Temperature control Thermostatic
Height 414 mm Control range 20 up to 50 °C
Length product assembly 361 mm kvs 2.20
Actuator No Max. operating temperature 95 °C
Universal thermal insulation Yes
Regumat MF-180 DN 25 with pump ball valve and integrated fixed flow temperature value control
With universal thermal insulation of modular construction.
Pump length 180 mm Wall bracket Yes
Optional supply pipe change Yes Pump ball valve Yes
Length 213 mm Temperature control Electronic
Height 465 mm Control range 0 up to 95 °C
3.1 Length product assembly 411 mm kvs 5.50
Actuator Yes Max. operating temperature 95 °C
Universal thermal insulation Yes PU 30
406
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
Wall bracket
3.1
For Regumat-180 DN 25 with pump ball valve (manufactured until 2015) 1356097
For Regumat-180 DN 25 without pump ball valve (manufactured until 2015) 1356098
407
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR HEATING CIRCUITS
3.1
409
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR SOLID FUEL BOILERS
410
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR SOLID FUEL BOILERS
Regumat RTA-180 DN 25
With thermal insulation.
Nominal size DN 25 Length 211 mm
Connection heating circuit G 1 1/2 external thread, flat Height 513 mm
sealing Length product assembly 460 mm
Connection heat generator G 1 1/2 external thread flat Universal thermal insulation No
sealing
kvs 3.90
Pump length 180 mm
Max. operating temperature 85 °C
Supply pipe Right
411
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT STATIONS FOR SOLID FUEL BOILERS
Regumat RTA-180 DN 25
With universal thermal insulation of modular construction.
Nominal size DN 25 Length 200 mm
Connection heating circuit G 1 1/2 external thread, flat Height 414 mm
sealing Length product assembly 371 mm
Connection heat generator G 1 1/2 external thread flat Universal thermal insulation Yes
sealing
kvs 3.90
Pump length 180 mm
Max. operating temperature 95 °C
Supply pipe Right
Regumat RTA-180 DN 32
With thermal insulation.
Nominal size DN 32 Length 207 mm
Connection heating circuit G 2 external thread, flat seal- Height 471 mm
ing Length product assembly 419 mm
Connection heat generator G 2 external thread flat seal- Universal thermal insulation No
3.1 ing
kvs 5.30
Pump length 180 mm
Max. operating temperature 85 °C
Supply pipe Right
Wall bracket
3.1
Replacement thermometer
413
3.1 Stations for heating circuit and cooling circuit
connection
414
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Regumat Distributors
Connection heating circuit G 1 union nut, flat seal- Wall bracket Yes
ing Material wall bracket Steel, galvanised
Connection heat generator G 1 external thread flat Max. flow rate 2.5 m³/h
sealing
Recommended range of applica- 60 kW
Centre distance 100 mm tion (∆T = 20 K)
Body material Steel Max. operating temperature 110 °C
Thermal insulation Yes Max. operating pressure 4 bar
Material thermal insulation Expanded polypropy-
lene (EPP)
2 1351482
3 1351483
2 1351571
415
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Connection heating circuit G 1 1/2 union nut, flat Wall bracket Yes
sealing Material wall bracket Steel, galvanised
Connection heat generator G 1 1/2 external thread Max. flow rate 4 m³/h
flat sealing
Recommended range of applica- 95 kW
Centre distance 125 mm tion (∆T = 20 K)
Body material Steel Max. operating temperature 110 °C
Thermal insulation Yes Max. operating pressure 4 bar
Material thermal insulation Expanded polypropy-
lene (EPP)
2 1351582
3 25 1351583
4 15 1351584
5 1351585
6 1351586
7 1351587
8 1351588
3 1351783
5 1351785
416
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
1 1351470
2 1351471
3 1351472
Connection heating circuit G 2 union nut, flat sealing Wall bracket Yes
Connection heat generator G 2 external thread flat seal- Material wall bracket Steel, galvanised
ing Max. operating temperature 110 °C
Centre distance 125 mm 3.1
Max. operating pressure 4 bar
Body material Steel
Thermal insulation Yes
Heating cir- Material thermal insulation Max. flow rate Recommended range of ap- PU Item No.
cuits (m³/h) plication (∆T = 20 K)
(kW)
Connection heating circuit G 2 union nut, flat sealing Material thermal insulation PU rigid foam
Connection heat generator G 2 external thread flat seal- Wall bracket No
ing Max. operating temperature 110 °C
Centre distance 125 mm Max. operating pressure 4 bar
Body material Steel
Thermal insulation Yes
Heating circuits Max. flow rate Recommended range of application (∆T = 20 K) Item No.
(m³/h) (kW)
2 12 280 1351662
3 12 280 1351663
4 26 600 1351664
5 26 600 1351665
417
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
2 1351692
3 1351693
4 1351694
3.1
418
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
2 1351568
3 1351569
2 25 1351698
3 10 1351699
Connection heating circuit G 1 1/2 union nut, flat Wall bracket Yes
sealing Material wall bracket Steel, galvanised
Connection heat generator G 1 1/2 external thread Max. flow rate 4 m³/h
flat sealing
Recommended range of applica- 95 kW
Centre distance 125 mm tion (∆T = 20 K)
Body material Steel Max. operating temperature 110 °C
Thermal insulation Yes Max. operating pressure 4 bar
Material thermal insulation Expanded polypropy-
lene (EPP)
1 1351589
419
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Hydraulic separator DN 25
1 1351590
2 1351758
3 1351759
Connection heating circuit G 2 union nut, flat sealing Material thermal insulation PU rigid foam
Connection heat generator G 2 external thread flat seal- Wall bracket No
ing Max. operating temperature 110 °C
Centre distance 125 mm Max. operating pressure 4 bar
Body material Steel
Thermal insulation Yes
Heating circuits Max. flow rate Recommended range of application (∆T = 20 K) Item No.
(m³/h) (kW)
2 12 280 1351678
3 26 600 1351679
420
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Hydraulic separator DN 32
1 1351591
2 1351778
3 1351779
421
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Stand bracket
3.1
Wall bracket
Plug set
422
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Connection fitting
For Regumat RTA below the distributor, 2 x G 1½ internal thread, 2-fold 1351655
Connection piece
3.1
423
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
For Regumat heat exchanger, for the protection of pressurised systems 1351598
3.1
For Regumat heat exchanger, for connecting a Regumat station to the primary side 1351597
424
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Thermal insulation
For Regumat heat exchanger item no. 1351790/1351791, made of expanded polypropylene 1359591
For Regumat heat exchanger item no. 1351792/1351793, made of expanded polypropylene 1359592
A A Regumat S-180 DN 25
E
B High-efficiency pump with
stainless steel / bronze housing Please note:
G 180 mm Wilo-Stratos PICO 25/1-6 When swapping the supply,
RG 1357160 both pumps must always be
F changed.
F Regumat M3-180 DN 25
Delivered with supply on the
with pump Wilo-Stratos right hand side.
PICO 25/1-6 RG 1357229
Installation dimensions:
G Connection piece set 1351597 H = 960 mm, W = 250 mm
425
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Coupling R 2 external thread x G 2 union nut (1 x), for connection to Regumat DN 40 / 50 1352089
3.1
427
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
For Regumat-180 DN 25 with pump ball valve (manufactured until 2015) 1356097
3.1
For Regumat-180 DN 25 without pump ball valve (manufactured until 2015) 1356098
3.1
Installation relay
Grounding clamp
3.1
For electrical connection of metallic pipework to the equipotential bonding.
DN 20 - DN 32 1359995
DN 40 - DN 50 1359996
430
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Regtronic RH weather-compensated heating circuit controller for variable/constant temperature heating circuit
Compatible with Datalog CS-BS-6, CS-BS-1 and Regtronic KM-TCP. Extendable by a maximum of 5 extension mod-
ules.
Application Heating circuit control Solid-state relays 3
Heat generator activation Electromechanical relays 2
Solid fuel boiler
Service water heating Potential-free relays 1
Boiler control
Item Modulating
no. Controller Required accessories (0-10 V) On/Off ErP % Class
Adapter cable
1152083 2.0 II
1152086
Regtronic RH
1152083 1.5 III
Adapter cable
1152080 4.0 VI
1152086
Adapter cable
For Regumat-180 DN 25 (manufactured from 2015), with Regtronic RH and controller bracket 1357290
Regtronic EM Extension module for the control of further variable/constant temperature heating circuits
For extening the Regtronic controller by 6 sensor inputs and 5 relay outputs.
Operating voltage 230 V Product compatible to Regtronic RH
Sensor inputs 6 Regtronic RM
Regtronic RS
Solid-state relays 4
Potential-free relays 1
3.1
432
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Weather-compensated control of 2 variable and 2 constant temperature heating circuits with heat demand (e.g. via a
conventional boiler, solid fuel boiler or heat pump) consisting of the Regtronic RH heating circuit controller with outdoor
sensor and Regtronic EM extension module.
Extension
oventrop
Outdoor A B
sensor Regtronic RH
S-bus
Heat demand
Pump heating circuit 1
T supply T supply
Pump heating circuit 4 3.1
D E
Pump heating circuit 2 D E
Mixing valve heating Mixing valve heating
circuit OPEN circuit OPEN
Boiler sensor
G C C
Boiler
F
Extension
433
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Boiler control
Modulating
Item no. Controller Required accessories (0-10 V) On/Off ErP % Class
For room temperature measurement, sensor element PT 1000, surface mounting 1152095
Room thermostat
3.1
With nominal value setting device. For the connection of electrothermal actuators (two point “normally closed”).
Room controller
Temperature sensor
Suitable for all Oventrop controllers.
3.1
436
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Connection elbow
Reducer
Double fitting
Check valve
3.1
T-piece
Connecting piece
Double nipple
3.1
Six-way block
Extension
DN 20, Rp ¾ internal thread, PN 10, brass, with lead sealing device 25 1089006
DN 20, Rp 1 internal thread, PN 10, brass, with lead sealing device 25 1089008
DN 32, Rp 1¼ internal thread, PN 10, brass, with lead sealing device 10 1089010
DN 40, Rp 1½ internal thread, PN 10, brass, with lead sealing device 10 1089012
DN 25, Rp 1 internal thread, PN 10, brass, with lead sealing device 10 1089052
3.1
441
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
Check valves
DN 25, G 1 external thread, G 1½ internal thread union nut, PN 10, brass 1070108
DN 32, G 1¼ external thread, G 2 internal thread union nut, PN 10, brass 1070110
DN 25, G 1 internal thread, G 1½ internal thread union nut, PN 10, brass 1070208
DN 32, G 1¼ internal thread, G 2 internal thread union nut, PN 10, brass 1070210
442
STATIONS FOR HEATING CIRCUIT AND COOLING CIRCUIT CONNECTION
REGUMAT ACCESSORIES
3.1
443
3.2 Stations for local and district heating
3.2
444
3.2 Stations for local and district heating
3.2
445
STATIONS FOR LOCAL AND DISTRICT HEATING
REGUDIS H TRANSMISSION STATIONS FOR LOCAL AND DISTRICT HEATING NETWORKS
Regudis H transmission stations with plate ent control valve with actuator, strainers with
heat exchanger for direct and indirect heat fill and drain ball valve, spacers for heat me-
transmission from a local or district heating ters, a safety group with pressure gauge, ball
network to the potable water and heating valves and a thermal insulation.
system of detached and semi-detached hous-
es. The stations are equipped with an elec- The compact stations are available in two
tronic controller for the weather-compensated performance classes and different connection
control of the flow temperature of the heating configurations. They are characterised by a
system and simultaneous limitation of the re- simple hydronic connection to the local and
turn temperature to the heat network. district heating network. The station is deliv-
ered with factory-mounted function modules,
The stations consist of a plate heat exchanger, completely parameterized and tested.
an electronic controller, a pressure independ-
Regudis H DN 20
With Regudis H transmission station and ball valve connection set.
Length 295 mm Connection heating network G 1 external thread
Width 545 mm Max. primary volume flow 1,300 l/h
Height 775 mm Max. primary differential pressure 4 bar
Connection heating circuit G 3/4 external thread PU 2
DN 20 1391026
Regudis H DN 25
With Regudis H transmission station and ball valve connection set.
Length 330 mm Connection heating network G 1 1/2 external thread
Width 630 mm Max. primary volume flow 4,800 l/h
Height 940 mm Max. primary differential pressure 6 bar
Connection heating circuit G 1 1/4 external thread PU 2
DN 25 1391036
446
STATIONS FOR LOCAL AND DISTRICT HEATING
REGUDIS H TRANSMISSION STATIONS FOR LOCAL AND DISTRICT HEATING NETWORKS
Regudis H-HT DN 20
For the connection of a constant temperature heating circuit and a potable water storage cylinder.
With Regudis H transmission station, ball valve connection set and HT switching module.
Length 295 mm Connection heating network G 1 external thread
Width 545 mm Max. primary volume flow 1,300 l/h
Height 1074 mm Max. primary differential pressure 4 bar
Connection heating circuit G 3/4 external thread
Connection heating circuit HT G 1 1/2 external thread
switching module
DN 20 1391027
Regudis H-HT DN 25
For the connection of a constant temperature heating circuit and a potable water storage cylinder.
With Regudis H transmission station, ball valve connection set and HT switching module.
Length 330 mm Connection heating network G 1 1/2 external thread
Width 630 mm Max. primary volume flow 4,800 l/h
Height 1182 mm Max. primary differential pressure 6 bar
Connection heating circuit G 1 1/4 external thread
Connection heating circuit HT G 1 1/2 external thread
switching module
Regudis H-MT DN 20
For the connection of a variable temperature heating circuit and a potable water storage cylinder.
With Regudis H transmission station, ball valve connection set, HT switching module and electric pipe contact safety
switch.
Length 295 mm Connection heating network G 1 external thread
Width 545 mm Max. primary volume flow 1,300 l/h
Height 1074 mm Max. primary differential pressure 4 bar
Connection heating circuit G 3/4 external thread
Connection heating circuit HT G 1 1/2 external thread
switching module
DN 20 1392027
447
STATIONS FOR LOCAL AND DISTRICT HEATING
REGUDIS H TRANSMISSION STATIONS FOR LOCAL AND DISTRICT HEATING NETWORKS
Regudis H-MT DN 25
For the connection of a variable temperature heating circuit and a potable water storage cylinder.
With Regudis H transmission station, ball valve connection set, HT switching module and electric pipe contact safety
switch.
Length 330 mm Connection heating network G 1 1/2 external thread
Width 630 mm Max. primary volume flow 4,800 l/h
Height 1182 mm Max. primary differential pressure 6 bar
Connection heating circuit G 1 1/4 external thread
Connection heating circuit HT G 1 1/2 external thread
switching module
DN 25 1392037
Regudis H-MHT DN 20
For the connection of a variable and a constant temperature heating circuit and a potable water storage cylinder.
With Regudis H transmission station, ball valve connection set, HT switching module, Regumat M3, electric pipe
contact safety switch and connection set.
Length 295 mm Connection heating network G 1 external thread
Width 545 mm Max. primary volume flow 1,300 l/h
Height 1550 mm Max. primary differential pressure 4 bar
Connection heating circuit G 3/4 external thread
Connection heating circuit HT G 1 1/2 external thread
switching module
3.2
Nominal size Item No.
DN 20 1393027
Regudis H-MHT DN 25
For the connection of a variable and a constant temperature heating circuit and a potable water storage cylinder.
With Regudis H transmission station, ball valve connection set, HT switching module, Regumat M3, electric pipe
contact safety switch and connection set.
Length 330 mm Connection heating network G 1 1/2 external thread
Width 630 mm Max. primary volume flow 4,800 l/h
Height 1706 mm Max. primary differential pressure 6 bar
Connection heating circuit G 1 1/4 external thread
Connection heating circuit HT G 1 1/2 external thread
switching module
DN 25 1393037
448
STATIONS FOR LOCAL AND DISTRICT HEATING
REGUDIS H TRANSMISSION STATIONS FOR LOCAL AND DISTRICT HEATING NETWORKS
Regudis H-H DN 20
For the connection of a constant temperature heating circuit.
With Regudis H transmission station, ball valve connection set, Regumat S and connection set.
Length 295 mm Connection heating network G 1 external thread
Width 545 mm Max. primary volume flow 1,300 l/h
Height 1220 mm Max. primary differential pressure 4 bar
Connection heating circuit G 3/4 external thread
DN 20 1391021
Regudis H-H DN 25
For the connection of a constant temperature heating circuit.
With Regudis H transmission station, ball valve connection set, Regumat S and connection set.
Length 330 mm Connection heating network G 1 1/2 external thread
Width 630 mm Max. primary volume flow 4,800 l/h
Height 1365 mm Max. primary differential pressure 6 bar
Connection heating circuit G 1 1/4 external thread
DN 25 1391031
3.2
Regudis H-M DN 20
For the connection of a variable temperature heating circuit.
With Regudis H transmission station, ball valve connection set, Regumat S, electric pipe contact safety switch and
connection set.
Length 295 mm Connection heating network G 1 external thread
Width 545 mm Max. primary volume flow 1,300 l/h
Height 1220 mm Max. primary differential pressure 4 bar
Connection heating circuit G 3/4 external thread
DN 20 1392021
Regudis H-M DN 25
For the connection of a variable temperature heating circuit.
With Regudis H transmission station, ball valve connection set, Regumat S, electric pipe contact safety switch and
connection set.
Length 330 mm Connection heating network G 1 1/2 external thread
Width 630 mm Max. primary volume flow 4,800 l/h
Height 1365 mm Max. primary differential pressure 6 bar
Connection heating circuit G 1 1/4 external thread
DN 25 1392031
449
STATIONS FOR LOCAL AND DISTRICT HEATING
REGUDIS H TRANSMISSION STATIONS FOR LOCAL AND DISTRICT HEATING NETWORKS
Type Connection Total height Ø (with ti)* Thickness TI* Item No.
(mm) (mm) (mm)
3.2
Regtronic EM Extension module for the control of further variable/constant temperature heating circuits
For extening the Regtronic controller by 6 sensor inputs and 5 relay outputs.
Operating voltage 230 V Product compatible to Regtronic RH
Sensor inputs 6 Regtronic RM
Regtronic RS
Solid-state relays 4
Potential-free relays 1
Replacement controller
Replacement actuator
3.2
451
3.3 Stations for hot potable water preparation
452
3.3 Stations for hot potable water preparation
3.3
453
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUMAQ X FRESH WATER STATIONS FOR CENTRAL HOT POTABLE WATER PREPARATION
The Regumaq X-25 fresh water station is The stations consist of a plate heat exchang-
an electronically controlled product assembly er, a controller box, a circulation pump, a back-
with heat exchanger for the hygienic heating flow preventer, a volume flow sensor, a safety
of potable water according to the continuous valve, temperature sensors, fill and drain ball
flow principle for connection to a buffer stor- valves and ball valves.
age cylinder. Depending on the temperature
and the volume flow on the potable water The compact stations are characterised by
side, the circulation pump on the heating side high draw off capacities at low excess temper-
is speed controlled. When selecting the fresh atures. The control technology is particularly
water station, it is necessary to consider the fast and precise due to turbine sensor technol-
water quality of the application area. ogy and LIN pump technology.
Regumaq X-25
454 Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/60 °C with ∆T 15 K (according to SFP test
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUMAQ X FRESH WATER STATIONS FOR CENTRAL HOT POTABLE WATER PREPARATION
The Regumaq X-45 fresh water station is a controller with touch control panel, a circu-
an electronically controlled product assembly lation pump, a backflow preventer, a volume
with heat exchanger for the hygienic heating flow sensor, a safety valve, temperature sen-
of potable water according to the continuous sors, fill and drain ball valves and ball valves.
flow principle for connection to a buffer stor-
age cylinder. Depending on the temperature The compact stations are characterised by
and the volume flow on the potable water high draw off capacities at low excess temper-
side, the circulation pump on the heating side atures. The control technology is particularly
is speed controlled. When selecting the fresh fast and precise due to turbine sensor technol-
water station, it is necessary to consider the ogy and LIN pump technology. With intuitive
water quality of the application area. touch control panel for setting extensive func-
tions such as circulation, return temperature
The stations consist of a plate heat exchanger, stratification or heat demand.
Regumaq X-45
Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/60 °C with ∆T 15 K (according to SFP test 455
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUMAQ X FRESH WATER STATIONS FOR CENTRAL HOT POTABLE WATER PREPARATION
For Regumaq X-45, with actuator, 230 V, operating time 20 s, kvs value 11.3, DN 25 1381190
Installation relay
3.3
Grounding clamp
For electrical connection of metallic pipework to the equipotential bonding.
DN 20 - DN 32 1359995
456
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUMAQ X FRESH WATER STATIONS FOR CENTRAL HOT POTABLE WATER PREPARATION
Strainer
Both sides flat sealing external thread, with double wire basket 250 µm, PN 25, DN 20 1141006
Connection fitting
3.3
Aquastrom R Backflow preventer
DN 25, 1 ¼ union nut x G 1 ¼ external thread, straight, bronze DVGW, SVGW 4208608
DN 32, 1 ½ union nut x G 1 ½ external thread, straight, bronze DVGW, SVGW 4208610
DN 25, G 1 ¼ external thread x G 1 ¼ external thread, straight, bronze DVGW, SVGW 4208708
DN 32, G 1 ½ external thread x G 1 ½ external thread, straight, bronze DVGW, SVGW 4208710
3.3
458
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUMAQ X FRESH WATER STATIONS FOR CENTRAL HOT POTABLE WATER PREPARATION
Replacement pump
For Regumaq X-25/X-45 and Regudis W-HTE, 5-fold, for junction G 3/4 1344497
For Regumaq X-25/X-45 and Regudis W-HTE, 5-fold, for junction G 1 1344498
Replacement controller
3.3
459
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUMAQ X FRESH WATER STATIONS FOR CENTRAL HOT POTABLE WATER PREPARATION
The Regumaq X-80 fresh water station is valve with actuator, a backflow preventer, a
an electronically controlled product assembly volume flow sensor, a safety valve, tempera-
with heat exchanger for the hygienic heating ture sensors, fill and drain ball valves and ball
of potable water according to the continuous valves.
flow principle for connection to a buffer stor-
age cylinder. Depending on the temperature The particularly powerful stations are charac-
and the volume flow on the potable water terised by high draw off capacities at low ex-
side, the circulation pump on the heating side cess temperatures. Remote access as well as
is speed controlled. When selecting the fresh networking and visualization are possible via
water station, it is necessary to consider the the Datalog CS-BS data logger. The controller
water quality of the application area. data can be set and read out via a web inter-
face or be passed on to the building manage-
The stations consist of a plate heat exchanger, ment system (BMS).
a controller, a circulation pump, a throttling
Regumaq X-80
460 Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/60 °C with ∆T 15 K (according to SFP test
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUMAQ X FRESH WATER STATIONS FOR CENTRAL HOT POTABLE WATER PREPARATION
For Regumaq X-80 potable water circulation set, with Wilo-Yonos PARA Z 15/7.0 RKC 130 1381591
For Regumaq X-80 potable water circulation set, with Wilo-Stratos PARA Z 25/1-12 RK 180 1381592
Shutoff unit
3.3
To prevent gravity circulation in the primary circuit.
Actuator
3.3
Installation relay
Grounding clamp
For electrical connection of metallic pipework to the equipotential bonding.
DN 20 - DN 32 1359995
DN 40 - DN 50 1359996
Connection fitting
One connection fitting item no. 1381585 is required to integrate a G 1 circulation pump installed on site into the
potable water circulation set item no. 1381590. One connection fitting item no. 1381587 and one connection fitting
item no. 1359091 are required for a G 1 1/2 circulation pump.
DN 40, 1 ¾ union nut x G 1 ¾ external thread, straight, bronze DVGW, SVGW 4208612
DN 40, G 1 ¾ external thread x G 1 ¾ external thread, straight, bronze DVGW, SVGW 4208712
3.3
For Regumaq X-80, 46 plates, copper brazed, Sealix® protective layer 1381584
For Regumaq X-80, 46 plates, copper brazed 1381595
For Regumaq X-80, 46 plates, nickel brazed 1381596 °
For Regumaq X-80 primary circuit, Grundfos UPML 25-105 180 PWM-C 1381599
3.3
Replacement controller
For Regumaq XZ-30, with three-way valve, actuator and storage cylinder sensor 1381066
Actuator
Exchange set
Spacer
3.3
Tailpipe set DN 20
For connection to Regumaq X-30/XZ-30 and Regusol X.
For Regumaq X-30/XZ-30 mit Regtronic PQ, pulse water meter 40 pulses/litre 1381093
For Regumaq X-30/XZ-30 with Regtronic RQ, VFD sensor 2-40 l/min 1389901
For Regumaq X-30/XZ-30 with Regtronic RQ, VFD sensor 2-40 l/min, sensor head, without hous-
1389902
ing
3.3
For Regumaq X-30/XZ-30 with Regtronic PQ, potable water hot, screw-in sensor PT 1000 1389050
For Regumaq X-30/XZ-30 with Regtronic PQ, potable water cold, sensor attached to the pipe PT
1389051
1000
For Regumaq X-30/XZ-30 with Regtronic RQ, potable water hot, screw-in sensor PT 1000 1389052
Replacement controller
3.3
468
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUMAQ X FRESH WATER STATIONS FOR CENTRAL HOT POTABLE WATER PREPARATION
For Regumaq XH, mesh size 0.5 mm, stainless steel 1381044 °
For Regumaq XH and Regucor WH/WHS, Wilo-Yonos ST 15/7 130 PWM2 for the primary circuit 1383582
3.3
3.3
471
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
undWSolareinbindung
Regudis with conventional heat generator, buffer storage cylinder and solar support
Regudis W-HTE
Regudis
with flow W-HTE
mit Vorlauf-
temperature
temperatur-
control module for
surface heatingfür
Regelmodul
Flächenheizung
Regudis
Regudis W-HTE
W-HTE
Regudis W-HTF
variable
Regudis W-HTF
3.3
temperature
gemischter
heating circuit
Heizkreis
Regudis
Regudis W-HTU
W-HTU
Regtronic
Regtronic RD-W
RD-W
Regumat M3-220
Regumat M3-220
RegusolL-130
Regusol L-130
Heat
Wärme-
generator
erzeuger
A control engineered integration of the Regudis W dwelling stations into the heating system can be carried out using
the Regtronic RD-W system controller.
472
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
For the supply of individual dwellings or com- control, a volume flow sensor, a temperature
mercial units with heating water, as well as sensor, a filter insert, spacers for heat and wa-
with hot and cold potable water. The required ter meter, vent valves and drain valves.
heat is provided by a central heat supply. Hot
potable water is prepared decentrally via a The Regudis W-HTE stations are designed for
plate heat exchanger according to the contin- constant temperature heating circuits and can
uous flow principle. When selecting the dwell- also be used for variable temperature heating
ing station, it is necessary to consider the wa- circuits with an optional flow temperature con-
ter quality of the application area. trol module. The range of functions can also
be extended in a modular way using extension
The stations consist of a plate heat exchang- modules. The stations are characterised by
er, a control valve with integrated differential high draw-off capacities at low excess temper-
pressure and volume flow control, an actua- atures, are optimised in terms of pressure loss
tor with integrated potable water temperature and offer a conclusive insulation concept.
Regudis W-HTE
Performance range Nominal draw off ca- Heat exchanger Certification Item No.
pacity*
(l/min)
Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test 473
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
B Cabinet 1344598
K
B
C Potable water circulation module 1344555
with time switch
J
C E Ball valve connection set for 1344484
circulation module
3.3
474
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
For Regudis W-HTE instantaneous water heater module, for fixing and piping in the cabinet. 1344561 +
3.3
For Regudis W-HTE, for shutting off all connections 142 1344480
For Regudis W-HTE potable water circulation module, for shutting off the circulation pipe 1344484
For Regudis W-HTE, for shutting off all connections, with flushing function of the supply
1344485
pipe
For Regudis W-HTE flushing and mounting bridge 1344489
For Regudis W-HTE, for shutting off all connections and for flexible hydronic connection
1344570 +
from above and/or below
Grounding clamp
For Regudis W, for equipotential bonding of dwelling stations without cabinet 1341092
Plug set
Accessory for installation in a four pipe system.
3.3
477
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Flush-mounted cabinet
For Regudis W-HTE, standard version, for flush wall mounting 1344098
Surface-mounted cabinet
3.3
Cylinder lock
With key for flush-mounted cabinets (item no. 1401151-54) and all Regudis W cabinets 1401191
478
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Room thermostat for two pipe applications, with display, flush mounting
Electronic control component for the constant temperature heating circuit.
3.3
Regtronic RH weather-compensated heating circuit controller for variable/constant temperature heating circuit
Compatible with Datalog CS-BS-6, CS-BS-1 and Regtronic KM-TCP. Extendable by a maximum of 5 extension mod-
ules.
Application Heating circuit control Solid-state relays 3
Heat generator activation Electromechanical relays 2
Solid fuel boiler
Service water heating Potential-free relays 1
3.3
Regtronic RD-W System controller for the integration of the Regudis W dwelling stations into the heat supply
For connecting differential pressure and temperature sensors to the pipework 1357291
For connecting temperature sensors to the pipework 1357292
3.3
Temperature sensor
Accessories for Regtronic RD-W System controller.
481
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
482
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
For Regudis W-HTE, with integrated differential pressure and volume flow control 1344492
Replacement actuator
For Regudis W-HTE, with integrated potable water temperature control 1344491
For Regumaq X-25/X-45 and Regudis W-HTE, 5-fold, for junction G 3/4 1344497
For Regumaq X-25/X-45 and Regudis W-HTE, 5-fold, for junction G 1 1344498
3.3
For Regudis W-HTE flow temperature control module, with contact sensor, 25 °C - 50 °C 1344582
483
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
For Regudis W-HTE potable water circulation module, Wilo Star-Z NOVA 1344580
For Regudis W-HTE flow temperature control module, Wilo Para 15-130/6-43/ SC-12 1344581
For Regudis W ball valve connection sets, ball valve for the supply pipe with red handle 1341980
For Regudis W ball valve connections sets, ball valve for the return pipe with blue handle 1341981
3.3
484
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
For the supply of individual dwellings or com- mostatic temperature controller, a filter insert,
mercial units with heating water, as well as spacers for heat and water meter, a zone valve
with hot and cold potable water. The required for heating circuit control, a differential pres-
heat is provided by a central heat supply. Hot sure regulator, vent valves and drain valves.
potable water is prepared decentrally via a
plate heat exchanger according to the contin- The Regudis W-HTU dwelling stations are
uous flow principle. When selecting the dwell- designed for variable temperature heating
ing station, it is necessary to consider the wa- circuits and are ideal for replacing existing
ter quality of the application area. gas boilers in building refurbishment projects.
They are characterised by high-quality mate-
The stations consist of a plate heat exchanger, rials and are completely mounted on a base
a proportional flow controller for hydronic con- plate. The stations are tested for tightness and
trol of hot potable water preparation, a ther- function.
Regudis W-HTU
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test 485
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
3.3
486
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Regudis W-HTU without cold water outlet and spacer for water meter
Performance range Nominal draw off capacity* Heat exchanger Certification Item No.
(l/min)
Regudis W-HTU without cold water outlet and spacer for water meter
With double-walled heat exchanger.
Heating circuit Constant tem- Spacer for heat meter Yes
perature Spacer for water meter No
Heat exchanger, double-walled Yes Safety valve No
Length 150 mm Zone valve Yes
Width 476 mm Max. operating pressure 10 bar
Supply connections Bottom Min. differential pressure supply 300 mbar
Heating circuit separation system No PU 10
High temperature outlet Yes Certification SVGW
Integrated differential pressure regula- Yes 3.3
tor
Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test 487
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Regudis W-HTO without cold water outlet and spacer for water meter
Supply connctions from the top.
With strainer in the potable water inlet.
Without cold water outlet dwelling and spacer for water meter.
With six ball valves.
Heating circuit Constant tem- Spacer for heat meter Yes
perature Spacer for water meter No
Heat exchanger, double-walled No Safety valve No
Length 150 mm Zone valve Yes
Width 476 mm Max. operating pressure 10 bar
Supply connections Top Min. differential pressure supply 300 mbar
Heating circuit separation system No PU 10
High temperature outlet Yes
Integrated differential pressure regula- Yes
tor
Performance range Nominal draw off capacity* Heat exchanger Certification Item No.
(l/min)
Regudis W-TU
For hot potable water preparation.
Without heating circuit, cold water outlet dwelling and spacers for water and heat meter.
Derivative temperature control set pre-assembled. With four ball valves.
Heat exchanger, double-walled No Spacer for water meter No
Length 150 mm Safety valve No
Width 476 mm Zone valve No
Supply connections Bottom Max. operating pressure 10 bar
3.3
Heating circuit separation system No Min. differential pressure supply 300 mbar
High temperature outlet No PU 10
Integrated differential pressure regulator Yes Certification SVGW, ACS
Spacer for heat meter No
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
488 Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Regudis W-TU
For hot potable water preparation.
Without heating circuit.
Derivative temperature control set pre-assembled.
Heat exchanger, double-walled No Spacer for heat meter Yes
Length 150 mm Spacer for water meter Yes
Width 476 mm Safety valve No
Supply connections Bottom Zone valve No
Heating circuit separation system No Max. operating pressure 10 bar
High temperature outlet No Min. differential pressure supply 300 mbar
Integrated differential pressure regulator Yes PU 10
Performance range Nominal draw off capacity* Heat exchanger Certification Item No.
(l/min)
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test 489
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
490 Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test ° Production will be discontinued
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
3.3
Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test 491
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
For the supply of individual dwellings or com- for heating circuit control, a differential pres-
mercial units with heating water, as well as sure regulator, vent valves and drain valves.
with hot and cold potable water. The required The version with variable temperature heating
heat is provided by a central heat supply. Hot circuit also features a thermostatic flow tem-
potable water is prepared decentrally via a perature control with integrated high-efficien-
plate heat exchanger according to the contin- cy pump for the low temperature range.
uous flow principle. When selecting the dwell-
ing station, it is necessary to consider the wa- The Regudis W-HTF dwelling stations are op-
ter quality of the application area. tionally available for constant or variable tem-
perature heating circuits and are ideally suited
The stations consist of a plate heat exchanger, for installation in lightweight partition walls
a proportional flow controller for hydronic con- due to their low installation depth. They are
trol of hot potable water preparation, a ther- characterised by high-quality materials and are
mostatic temperature controller, a filter insert, completely mounted on a base plate. The sta-
spacers for heat and water meter, a zone valve tions are tested for tightness and function.
Proportional flow controller Yes Min. differential pressure sup- 300 mbar
ply
Integrated differential pressure Yes
regulator Leak tested Yes
3.3
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
492 Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
3.3
493
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
Regudis W-HTF with variable temperature heating circuit and high temperature outlet
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
Regudis W-HTF with constant temperature heating circuit and circulation pipe
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
494 Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Regudis W-HTF with variable temperature heating circuit and circulation pipe
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
Regudis W-HTF with variable temperature heating circuit, high temperature outlet and circulation pipe
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
Performance range Nominal draw off capacity* Heat exchanger Item No.
(l/min)
Nominal draw off capacity = Nominal draw off capacity heating of potable water 10 °C/50 °C with ∆T 15 K (according to SFP test 495
procedure)
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
3.3
496
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
For Regudis W-HTF, for connecting Multidis SF heating circuit distributors/collectors 1341187
T-piece
497
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Plug
For Regudis W-HTF, for temperature sensor, G ½ external thread x M 10 x 1.0 internal thread, Ø 5.6 1349051
For Regudis W-HTF, for temperature sensor, G ½ x M 12 x 1.5 1349053
For Regudis W-HTF with high temperature outlet, for temperature sensor, G ¼ external thread x M
1349054
10 x 1,0 internal thread, Ø 5.6
498
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Drain set
For Regudis W, for easy draining of the heating circuit when installing a heat meter 1341094 °
Flow limiter
Conversion set
For Regudis W-TU/W-HTU/W-HTU-Duo, for retrofitting a cold water meter to the dwelling 1341093 °
3.3
Connection set
For Regudis W, with 7 flexible corrugated pipes which can be shortened individually 1341081 °
Bonnet
1340920
1340930/31/32
1340950/51/52
1341030/31/32
1341050/51/52
1341121
1341130/31/32
1341140/41/42
1341150/51/52
1341160/61/62
1341220
1341231/51
3.3 1341252/62
1341257/67
1341271/74
1341332
1341340/41/42
1341360/61/62
1341372
1341442/62
1341542/62
1341642/62
500
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Cabinets
Regubox
1341070 1341170 1341175 1341177 1341071 1341198 1341193 1341074 1341098
1 1
1 1
1 1
1 1
1 1
1 1
3.3
1 1
1 1
501
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
Flush-mounted cabinet
Surface-mounted cabinet
Surface-mounted bonnet
For Regudis W, wall-hung, pipe lead-through from above and below 7 1341072
For Regudis W, standard model 8 1341095
For Regudis W, standard model, stainless steel design 1341097 °
For Regudis W, standard model, with door 10 1341195
3.3
For Regudis W, wide model 10 1341197
For Regudis W, long model, pipe lead-through from above and below 7 1341295
For Regudis W-HTU with double-walled heat exchanger, standard model 8 1341296
Refurbishment frame
For Regubox exclusive cabinet (item no. 1341098), floor-standing installation, adjustable height 1341099 °
For Regubox exclusive cabinet (item no. 1341098), wall mounting 1341199 °
Cylinder lock
With key for flush-mounted cabinets (item no. 1401151-54) and all Regudis W cabinets 1401191
3.3
For Regudis W, for potable water temperature control, with spiral sensor made of stainless steel 1343092
3.3
504
STATIONS FOR HOT POTABLE WATER PREPARATION
REGUDIS W DWELLING STATIONS FOR DECENTRALISED HOT POTABLE WATER PREPARATION
For Regudis W-HTF with potable water circulation, Wilo-Star-Z NOVA 1349096
For Regudis W-HTF with variable temperature heating circuit, Wilo-Yonos PARA RS 15/6 RK 1349097 °
For Regudis W ball valve connection sets, ball valve for the supply pipe with red handle 1341980
For Regudis W ball valve connections sets, ball valve for the return pipe with blue handle 1341981
3.3
3.4
506
3.4 Storage cylinders
3.4
507
STORAGE CYLINDERS
HYDROCOR STORAGE CYLINDERS
Buffer storage cylinders for the storage of for withdrawal in the upper standby volume.
heating water. Various heat generators, such Additionally there is a connection for an elec-
as conventional boilers, heat pumps, solid fuel tric immersion heater and an air vent connec-
boilers or solar thermal systems can be con- tion at the torispherical head. Temperature
nected. sensors can be positioned at lateral sensor
clamps.
The buffer storage cylinders have a separating
sheet in the upper third of the cylinder for The storage cylinders are particularly energy
better separation of the standby volume. The efficient due to a fibre fleece insulation (ener-
loading and unloading connections are equip- gy efficiency class C) or a composite insulation
ped with baffle plates, one unloading connec- (energy efficiency class A).
tion has an internally raised connection pipe
Hydrocor HP
Without thermal insulation. Thermal insulation available as accessory.
Total height 1,720 mm Max. operating pressure 3 bar
Ø (without ti)* 650 mm
500 1387505 °
3.4 Hydrocor HP
With thermal insulation (energy efficiency class C).
Thickness TI* 160 mm
Type Total height Ø (without ti)* Ø (with ti)* Max. operating pressure Item No.
(mm) (mm) (mm) (bar)
508 Ø (without ti) = Diameter (without thermal insulation) ° Production will be discontinued
Ø (with ti) = Diameter (with thermal insulation)
Thickness TI = Thickness thermal insulation (fibre fleece)
STORAGE CYLINDERS
HYDROCOR STORAGE CYLINDERS
Solar buffer storage cylinders for the storage connection has an internally raised connection
of heating water with additional internal tube pipe for withdrawal in the upper standby vol-
heat exchanger for the connection to a solar ume. Additionally there is a connection for an
thermal system. Additional heat generators, electric immersion heater and an air vent con-
such as conventional boilers, heat pumps, sol- nection at the torispherical head. Temperature
id fuel boilers or solar thermal systems can be sensors can be positioned at lateral sensor
connected. clamps.
The solar buffer storage cylinders have a sep- The storage cylinders are particularly energy
arating sheet in the upper third of the cylin- efficient due to a fibre fleece insulation (ener-
der for better separation of the standby vol- gy efficiency class C) or a composite insulation
ume. The loading and unloading connections (energy efficiency class A).
are equipped with baffle plates, one unloading
Hydrocor HS
Without thermal insulation. Thermal insulation available as accessory.
Total height 1,720 mm Ø (without ti)* 650 mm
500 1385105 °
3.4
Hydrocor HS
With thermal insulation (energy efficiency class C).
Ø (without ti)* 790 mm Thickness TI* 160 mm
Ø (with ti)* 1,090 mm
Ø (without ti) = Diameter (without thermal insulation) ° Production will be discontinued 509
Ø (with ti) = Diameter (with thermal insulation)
Thickness TI = Thickness thermal insulation (fibre fleece)
STORAGE CYLINDERS
HYDROCOR STORAGE CYLINDERS
Thermal insulation
3.4
Extension
For passing the electrical immersion heater through the thermal insulation 1383592 °
Hydrocor WM
Type Connection Total height Ø (with ti)* Thickness TI* Item No.
(mm) (mm) (mm)
3.4
Hydrocor WB
300 1387303 °
3.4
512 Ø (with ti) = Diameter (with thermal insulation) ° Production will be discontinued
Thickness TI = Thickness thermal insulation (PUR rigid foam)
3.4 Storage cylinders
3.4
513
STORAGE CYLINDERS
REGUCOR ENERGY STORAGE CENTRES
B
B
F
F
C
C
Boiler
Kessel
A
A
E D
D
3.4
514
STORAGE CYLINDERS
REGUCOR ENERGY STORAGE CENTRES
Modular system for the solar-supported sup- tem storage cylinder, a Regusol LH-130 DN
ply of detached and semi-detached houses 20 solar station, a Regumaq XH DN 20 fresh
with heat and hot water. The storage cylinder water station, a Regumat M3-130 DN 20 heat-
and the add-on groups are functionally and ing circuit station and a multifunctional system
thermodynamically coordinated. With integra- controller.
ted pipework and cabling ready for plug-in.
For combination with conventional (e.g. gas/ The energy storage centre is characterised by
oil) and regenerative heat generators (e.g. heat low installation and piping costs due to inter-
pump/solid fuel) in existing and new buildings. nal pipework, pre-assembled add-on groups
and only one connection level to the building
The energy storage centre consists of a sys- installation.
Regucor WHS
Without thermal insulation. Thermal insulation available as accessory.
Regucor WHS
With thermal insulation (energy efficiency class C).
Boiler control
Modulating
Controller Required accessories (0-10 V) On/Off ErP % Class
2.0 II
Regucor contoller
Regtronic RS O 1.5 III
incl. remote control
with room temperature sensor
2 x Room temperature sensor
4.0 VI
1152095
Modular system for the supply of detached tem storage cylinder, a Regumaq XH DN 20
and semi-detached houses with heat and hot fresh water station and a Regumat M3-130 DN
water. The storage cylinder and the add-on 20 heating circuit station.
groups are functionally and thermodynamical-
ly coordinated. With integrated pipework and The energy storage centre is characterised by
cabling ready for plug-in. For combination with low installation and piping costs due to inter-
conventional (e.g. gas/oil) and regenerative nal pipework, pre-assembled add-on groups
heat generators (e.g. heat pump/solid fuel) in and only one connection level to the building
existing and new buildings. installation.
The energy storage centre consists of a sys-
Regucor WH
With thermal insulation (energy efficiency class C).
3.4
Thermal insulation
For Regucor WH/WHS, with three-way valves, electromotive actuators and angle adapter 1383583 °
Connection set
For Regucor WH/WHS, for connection of the heating circuit station and the fresh water station 1383580 °
For Regucor WH/WHS, for connection of an additional heating circuit station 1383581 °
For Regucor WH/WHS, for connection of the extension set potable water circulation 1383584 °
3.4
Solar diaphragm expansion tank
For wall mounting
PU 80
PU 25
Extension
For passing the electrical immersion heater through the thermal insulation 1383592 °
For passing the connection pipe for storage cylinder loading through the thermal insulation 1383593 °
3.4
Sensor LW TH
Suitable for all Oventrop controllers.
3.4
520
Potable water
4
4.1 Products for the preservation of potable water
hygiene
4.1
524
4.1 Products for the preservation of potable water
hygiene
Potable water
525
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
Hygiene with the Aquanova-system – for our most important food: Potable water
Potable water can spoil like any other food. pure and safe for consumption, in accordance Our Aquanova system includes systems,
The potable water installation has a great with the German Potable Water Ordinance products, software and other services related
influence on this. It is the “packaging” that (TrinkwV). Therefore, neither the operation to potable water.
carries the water from the house connection nor the materials used in the potable water
to the individual tapping points - hygienically installation may impair the water quality. Another advantage: we are not only the
partner for clean potable water, but also for
efficient heating and cooling.
C
E H
D
I
4.1
526
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
DN 15 G 3/4 4206704
DN 20 G1 4206706
527
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
DN 15 15 mm 4205752
DN 15 18 mm 4205753
DN 20 22 mm 4205754
4.1
528
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
Thermal circulation valve with adjustable tem- perature sensor can be retrofitted.
perature control range for hydronic balancing
in circulation pipes according to DVGW work Valve made of bronze, all parts coming into
sheet W551/W553. contact with the medium free from brass. A
thermal insulation shell made of expanded
Below the set temperature, the valve opens polystyrene according to the German Energy
and automatically increases the hot water vol- Saving Ordinance (EnEV) and building material
ume flow. The valve has a fixed residual vol- class B1 according to DIN 4102 is included in
ume flow, automatically detects thermal disin- the scope of delivery or is available as accesso-
fection and allows the maximum volume flow ry.
to be limited and shut off via an integrated The temperature and volume flow settings can
regulating unit with reproducible presetting. be lead sealed to prevent unintentional adjust-
The valve is equipped with a drain valve with ment.
hose connection and a thermometer. A tem-
529
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
DN 15 G 3/4 4206504
DN 20 G1 4206506
DN 25 G1¼ 4206508
DN 15 15 mm 4205552
DN 15 18 mm 4205553
DN 20 22 mm 4205554
DN 25 28 mm 4205555
DN 15 G 3/4 4206604
DN 20 G1 4206606
DN 25 G1¼ 4206608
530
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
Aquastrom T plus with internal thread, without accessories and without shutoff facility and presetting
DN 15 Rp 1/2 4205404
DN 20 Rp 3/4 4205406
4.1
531
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
DN 15 6 up to 18 WRAS 4205904
DN 15 12 up to 24 4206304
4.1
532
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
Operating point = Fixed value setting for the operating point 533
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
534 Operating point = Fixed value setting for the operating point
Ø = Diameter
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
4.1
Dial thermometer
For installation in the drain valve for hose connection item no. 4205593.
For remote monitoring for Aquastrom VT, T plus, C, F, KFR and M, PT 1000, G 1/4 4205592
Handwheel set for Aquastrom UP-Therm flush-mounted circulation valves without flush-mounted sleeve
Suitable for flush-mounted valves without flush-mounted sleeve and water meter installation sets, consisting of
chrome plated operating handle, chrome plated cover rosette, sleeve as well as three coloured marking plates.
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 0-35 mm 4223192
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 35-135 mm, lock-
4223193
shield configuration
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 35-90 mm 4223195
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 0-40 mm, lockshield
4223196
configuration
Handwheel set for Aquastrom UP-Therm flush-mounted circulation valves with flush-mounted sleeve
Suitable for flush-mounted valves with flush-mounted sleeve consisting of top part assembly with clamping unit,
rack, chrome plated operating handle, chrome plated cover rosette as well as three coloured marking plates.
Extension set for Aquastrom UP-Therm flush-mounted circulation valves with flush-mounted sleeve
4.1
Description Item No.
Mounting set for Aquastrom UP-Therm flush-mounted circulation valves with flush-mounted sleeve
For front wall installation.
536
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM THERMAL CIRCULATION VALVES
Replacement handwheel
537
4.1 Products for the preservation of potable water
hygiene
4.1
538
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM STATIC CONTROL VALVES
Static circulation valve for hydronic balancing contact with the medium free from brass. A
in circulation pipes according to DVGW work thermal insulation shell made of expanded
sheet W551/W553. polystyrene according to the German Energy
Saving Ordinance (EnEV) and building material
The valve allows the maximum volume flow class B1 according to DIN 4102 is included in
to be limited and shut off via an integrated the scope of delivery or is available as accesso-
regulating unit with reproducible presetting. ry.
The valve is equipped with a drain valve with
hose connection and a thermometer. A tem- The temperature and volume flow settings can
perature sensor can be retrofitted. be lead sealed to prevent unintentional adjust-
ment.
Valve made of bronze, all parts coming into
4.1
Nominal size Connection size PU Item No.
DN 20 G1 160 4207106
DN 15 Rp 1/2 4208104
DN 20 Rp 3/4 4208106
DN 25 Rp 1 4208108
DN 32 Rp 1 ¼ 4208110
539
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM STATIC CONTROL VALVES
DN 15 Rp 1/2 4208504
DN 20 Rp 3/4 4208506
DN 25 Rp 1 4208508
DN 32 Rp 1 ¼ 4208510
DN 15 Rp 1/2 10 4208152
DN 20 Rp 3/4 10 4208154
DN 25 Rp 1 10 4208156
DN 32 Rp 1 ¼ 5 4208158
DN 15 G 3/4 4207104
DN 15 G 3/4 4207504
DN 20 G1 4207506
DN 25 G1¼ 4207508
DN 32 G 1 1/2 4207510
540
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM STATIC CONTROL VALVES
Aquastrom M Measuring and draining device with flat sealing external thread
With outlet nipples G 1/4 internal thread and G 3/8 internal thread.
Measuring valve
4.1
541
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
AQUASTROM STATIC CONTROL VALVES
Dial thermometer
For installation in the drain valve for hose connection item no. 4205593.
For remote monitoring for Aquastrom VT, T plus, C, F, KFR and M, PT 1000, G 1/4 4205592
Blocking set
Identification ring
Can be clipped onto the handwheel for riser identification.
Replacement insert
4.1
543
4.1 Products for the preservation of potable water
hygiene
4.1
544
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
CIRCULATION AND FLUSHING STATIONS
Hygiene flushing station for protecting cold unit. Flushing riser with solenoid valve and vol-
and hot water risers and for maintaining the ume flow sensor, with shutoff facility.
intended operation in potable water installa- Regtronic HS electronic control for controlling
tions, e.g. in the event of interruptions in use. the valves, individually programmable, with
For installation at the end of the riser or in ring web access via LAN or WLAN and log func-
installations. tion.
Free outlet type AB according to EN 1717 for
Completely pre-assembled and leak tested connection to the sewage network.
Regudrain with Regtronic HS controller, individually programmable, with web access, with log function
Connections:
Potable water circuit: flat sealing G 3/4 external thread
Sewage network: DN 40
Certification DVGW, SVGW
G 3/4 union nut x G 3/4 external thread x G 3/4 external thread 4207095
Sensor LW TQ
4.1
Humidity sensor
To indicate leaks or blocked drains.
2m 4207099
546
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
CIRCULATION AND FLUSHING STATIONS
Temperature sensor
Sensor cable
For connecting the sensors item no. 1150090, 1369095 and 4207099 to the Regudrain flushing stations.
For Regudrain, from 200 mm x 350 mm to 520 mm x 620 mm, with fixing material 4207090
With volume flow sensor, flow controller and jet regulator, 24 V DC 4207092
547
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
CIRCULATION AND FLUSHING STATIONS
Replacement siphon
For Regudrain flush valve, set with versions 5 l/min, 7 l/min and 11 l/min 4207096
4.1
548
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
CIRCULATION AND FLUSHING STATIONS
Circulation pump assembly for potable water backflow preventer and Aquastrom VT ther-
circulation systems with storage cylinder in mal circulation valve as well as control ther-
detached and semi-detached houses. mometer for direct connection to the return
pipe of a circulation pipe according to DVGW
With energy-saving high-efficiency pump, work sheet W551/W553.
Regucirc B with pump, integrated service water mixing valve and thermometer ball valves
Pre-installed pump: Biral AX20-4 120BLUE
4.1
Dial thermometer
Sensor LW TH
Strainer
4.1
550
PRODUCTS FOR THE PRESERVATION OF POTABLE WATER HYGIENE
CIRCULATION AND FLUSHING STATIONS
DN 20 4206790
4.1
551
4.2 Shutoff valves and other products for potable
water
552
4.2 Shutoff valves and other products for potable water
4.2
553
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
Extremely low-noise free-flow valve for pota- Can be converted to a KFR valve by changing
ble water installations. the insert. Draining facility within same plane
as handwheel, therefore allowing pipes to be
Y-pattern valve made of bronze, all parts com- at close centres. The valves with drain bores
ing into contact with the medium free from can be retrofitted with a drain ball valve which
brass, with plastic handwheel, design accord- is available as accessory.
ing to DIN 3502. All functions accessible from
the top. Maintenance-free spindle sealing by Sound insulation according to DIN EN ISO
double O-ring. 3822: Product group I
Aquastrom F with internal thread and drain bores G ¼ closed with plugs
554
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
DN 15 15 mm SVGW 10 4201252
DN 15 18 mm SVGW 10 4201253
DN 20 22 mm SVGW 10 4201254
DN 25 28 mm SVGW 10 4201255
DN 32 35 mm SVGW 5 4201256
DN 40 42 mm SVGW 5 4201257
DN 50 54 mm SVGW 5 4201258
Aquastrom F with flat sealing external thread and drain ball valve G ¼
Aquastrom F with flat sealing external thread and drain bores G ¼ closed with plugs
4.2
555
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
Aquastrom F with flat sealing external thread and drain bores G 3/8 closed with plugs
DN 65 G3 DVGW 4202220
DN 80 G 3 1/2 DVGW 4202224
DN 65 G3 DVGW 4201820 °
DN 80 G 3 1/2 DVGW 4201824 °
Aquastrom F with flanges and drain bores G 3/8 closed with plugs
4.2
Aquastrom F with flat sealing external thread and drain bores G ¼ closed with plugs
With enlarged sealing surfaces for thick-walled plastic pipes.
Aquastrom F with internal thread / flat sealing external thread and drain bores G ¼ closed with plugs
Aquastrom F with solder connection / union nut and drain bores G ¼ closed with plugs
DN 15 15 mm DVGW 10 4203852 °
DN 15 18 mm DVGW 10 4203853 °
DN 20 22 mm DVGW 10 4203854 °
DN 25 28 mm DVGW 10 4203855 °
DN 32 35 mm DVGW 5 4203856 °
DN 40 42 mm DVGW 5 4203857 °
DN 50 54 mm DVGW 5 4203858 °
4.2
Aquastrom KFR with internal thread and drain bores G ¼ closed with plugs
558
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
Aquastrom KFR with flat sealing external thread and drain ball valve G ¼
Aquastrom KFR with flat sealing external thread and drain bores G ¼ closed with plugs
Aquastrom KFR with flat sealing external thread and drain bores G 3/8 closed with plugs
Aquastrom KFR with flat sealing external thread, without drain bores
Aquastrom KFR with flanges and drain bores G 3/8 closed with plugs
Aquastrom KFR with internal thread / flat sealing external thread and drain bores G ¼ closed with plugs
Aquastrom KFR with flat sealing external thread and drain bores G ¼ closed with plugs
With enlarged sealing surfaces for thick-walled plastic pipes.
4.2
Aquastrom FR with flat sealing external thread, backflow preventer and drain bores G ¼ closed with plugs
DN 15 G 3/4 10 4202704 °
DN 20 G1 10 4202706 °
DN 25 G1¼ 10 4202708 °
DN 32 G 1 1/2 5 4202710 °
4.2
4.2
562 Ø = Diameter
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
Ø = Diameter 563
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
For Hydrocontrol VTR, ATR, Hydromat DTR and Aquastrom F/KFR, DN 15 350 1060081
For Hydrocontrol VTR, ATR, Hydromat DTR and Aquastrom F/KFR, DN 20 260 1060082
For Hydrocontrol VTR, ATR, Hydromat DTR and Aquastrom F/KFR, DN 25 1060083
For Hydrocontrol VTR, ATR, Hydromat DTR and Aquastrom F/KFR, DN 32 130 1060084
For Hydrocontrol VTR, ATR, Hydromat DTR and Aquastrom F/KFR, DN 40 1060085
For Hydrocontrol VTR, ATR, Hydromat DTR and Aquastrom F/KFR, DN 60 80 1060086
DN 15, ¾ union nut x G ¾ external thread, straight, bronze DVGW, SVGW 4208604
DN 20, 1 union nut x G 1 external thread, straight, bronze DVGW, SVGW 4208606
DN 25, 1 ¼ union nut x G 1 ¼ external thread, straight, bronze DVGW, SVGW 4208608
DN 32, 1 ½ union nut x G 1 ½ external thread, straight, bronze DVGW, SVGW 4208610
DN 40, 1 ¾ union nut x G 1 ¾ external thread, straight, bronze DVGW, SVGW 4208612
DN 50, 2 ⅜ union nut x G 2 ⅜ external thread, straight, bronze DVGW, SVGW 4208616
DN 15, G ¾ external thread x G ¾ external thread, straight, bronze DVGW, SVGW 4208704
DN 20, G 1 external thread x G 1 external thread, straight, bronze DVGW, SVGW 4208706
DN 25, G 1 ¼ external thread x G 1 ¼ external thread, straight, bronze DVGW, SVGW 4208708
DN 32, G 1 ½ external thread x G 1 ½ external thread, straight, bronze DVGW, SVGW 4208710
DN 40, G 1 ¾ external thread x G 1 ¾ external thread, straight, bronze DVGW, SVGW 4208712
DN 50, G 2 ⅜ external thread x G 2 ⅜ external thread, straight, bronze DVGW, SVGW 4208716
564
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
Dial thermometer
For installation in the drain valve for hose connection item no. 4205593.
For remote monitoring for Aquastrom VT, T plus, C, F, KFR and M, PT 1000, G 1/4 4205592
Replacement insert
565
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 0-35 mm 4223192
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 35-135 mm, lock-
4223193
shield configuration
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 35-90 mm 4223195
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 0-40 mm, lockshield
4223196
configuration
Handwheel set for Aquastrom UP flush-mounted free-flow valves with flush-mounted sleeve
Suitable for flush-mounted valves with flush-mounted sleeve consisting of top part assembly with clamping unit,
rack, chrome plated operating handle, chrome plated cover rosette as well as three coloured marking plates.
Extension set for Aquastrom UP flush-mounted free-flow valves with flush-mounted sleeve
4.2
566
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
AQUASTROM FREE-FLOW AND KFR VALVES
Replacement handwheel
4.2
4.2
568
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
OPTIBAL BALL VALVES FOR POTABLE WATER
Ball valve for potable water without dead zone ring made of EPDM, all parts coming into con-
and with full flow according to DIN EN 13828. tact with the medium are free from brass. Up
The ball is always surrounded by water. to size DN 50 with extended plastic handle,
from size DN 65 with lever made of galvanised
Body made of bronze, ball chrome plated, steel.
maintenance-free spindle sealing by double O-
Optibal TW with internal thread and drain bore G ¼ closed with a plug
DN 15 Rp 1/2 10 4208804
DN 20 Rp 3/4 10 4208806
DN 25 Rp 1 10 4208808
DN 32 Rp 1 ¼ 10 4208810
DN 40 Rp 1 1/2 5 4208812
DN 50 Rp 2 5 4208816
4.2
DN 65 Rp 2 1/2 4208820
DN 80 Rp 3 4208824
569
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
OPTIBAL BALL VALVES FOR POTABLE WATER
Optibal TW with press connection and drain bore G ¼ closed with a plug
For direct connection of copper pipe according to DIN EN 1057 / DVGW GW 392 and stainless steel pipe according to
DIN EN 10088 / DVGW GW 451.
Pressing must be carried out to tighten the connection. Only use press jaws with original contours SANHA (SA),
Geberit-Mapress (MM) or Viega (Profipress) in the appropriate size for pressing.
Certification DVGW, ACS
DN 15 15 mm 10 4208852
DN 15 18 mm 10 4208853
DN 20 22 mm 10 4208854
DN 25 28 mm 10 4208855
DN 32 35 mm 10 4208856
DN 40 42 mm 5 4208857
DN 50 54 mm 5 4208858
Optibal TW with external thread and drain bore G ¼ closed with a plug
4.2
570
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
OPTIBAL BALL VALVES FOR POTABLE WATER
Electromotive actuator
4.2
571
4.2 Shutoff valves and other products for potable water
4.2
572
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
SYSTEM COMPONENTS FOR THE POTABLE WATER INSTALLATION
DN 20 G1 35 up to 65 1300306
DN 25 G1¼ 35 up to 65 1300308
DN 32 G 1 1/2 35 up to 65 1300310
DN 20 G1 30 up to 70 25 1300200
DN 20 G1 30 up to 70 20 1300251
4.2
DN 20 G1 35 up to 50 1300351
DN 20 G1 35 up to 50 1300352
573
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
SYSTEM COMPONENTS FOR THE POTABLE WATER INSTALLATION
Inline thermometer
For Brawa-Mix DN 20, G 1 union nut x G 1 external thread, bronze, length 74 mm 1300952
For Brawa-Mix DN 25, G 1¼ union nut x G 1¼ external thread, bronze, length 70 mm 1300953
For Brawa-Mix DN 32 , G 1½ union nut x G 1½ external thread, bronze, length 81 mm 1300954
4.2
Strainer
WRAS 10 1120006
WRAS 10 1120008
WRAS 5 1120010
574
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
SYSTEM COMPONENTS FOR THE POTABLE WATER INSTALLATION
Medium temperature (continuous operation) up to 30 °C on the inlet side, up to 65 °C on the outlet side.
Outlet pressure 1-5 bar adjustable.
According to DIN EN 1717, all installations must be intrinsically safe and designed as permanent connections.
This means that the heating system must be filled via a system separator type BA or BC!
4.2
575
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
SYSTEM COMPONENTS FOR THE POTABLE WATER INSTALLATION
4.2
576
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
SYSTEM COMPONENTS FOR THE POTABLE WATER INSTALLATION
Aquastrom UP-MS
Fixing set
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 0-35 mm 4223192
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 35-135 mm, lock-
4223193
shield configuration
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 35-90 mm 4223195
For Aquastrom UP, DN 15 / DN 20 and Aquastrom UP-MS, wall construction 0-40 mm, lockshield
4223196
configuration
4.2
Frost-proof outdoor tap for potable water in- Handwheel chrome-plated, in various designs.
stallations. Simple shutoff through patented ceramic car-
tridge.
Wall plate design for passing through mason- Automatic internal venting, draining to the
ry, all parts coming into contact with the medi- outside.
um made of ceramic, lead-free brass or stain- Maintenance-free spindle seal, all functional
less steel. parts can be replaced from the outside.
4.2
578
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
SYSTEM COMPONENTS FOR THE POTABLE WATER INSTALLATION
G ¾ Eurocone
metal to metal sealing
Item no. 102747.
Copper pipe
Screw connection
EN 1057
G ¾ Eurocone
metal to metal sealing
Item no. 102747.
Other pipes
e.g. stainless steel
Other pipes can be connected with the fittings of the respective system suppliers
pipe, thick-walled
plastic pipe
1) Pipes with a wall thickness ≤ 1mm will need support sleeves, item no. 2083951/52 or 1029651-57, unless the soft sealing fitting item no. 102744.!
579
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
SYSTEM COMPONENTS FOR THE POTABLE WATER INSTALLATION
4.2
581
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
POTABLE WATER DISTRIBUTION
Potable water distribution system made of as optional water treatment devices and distri-
bronze. The system enables the quick creation butions. The components are screwed togeth-
of domestic water distributions with shutoff er with flat seals. The connection dimension is
devices, water meters and water filters as well 140 mm.
Aquamodul T-distributor
Inlet G 1¼ union nut, outlet G 1¼ flat sealing external thread, 140 mm, bronze
Aquamodul Elbow
Inlet G 1¼ union nut, outlet G ¾ flat sealing external thread, 70 mm, bronze
Bypass device
For connection to the EAS one pipe connection piece, bronze.
Item No.
4200308 °
For closing the EAS one pipe connection piece, without connection thread 4200211 °
For closing the EAS one pipe connection piece, with connection thread Rp ¾ 4200212 °
4.2
Bracket
Clamping range ø 31-35 mm, with pipe clamps, hanger bolts and dowels 4200295 °
DN 8 G¼ 4200191
Double fitting
4.2
Nipple
Cap
Plug
Drain valve
DN 8, G ¼ external thread, self sealing, with rotatable outlet for ⅜ hose 4209602
DN 10, G ⅜ external thread, self sealing, with rotatable outlet for ⅜ hose 4209603
DN 15, G ½ external thread, self sealing, with rotatable outlet for ⅜ hose 4209604
4.2
Sanitary distributor made of bronze, without With rotatable identification plate for marking
dead zone. Completely pre-assembled and the outlet connections.
leak tested unit.
4.2
586
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
POTABLE WATER DISTRIBUTION
Bracket
Cap
Cabinet
Flush-mounted model, steel, galvanised, frame and door white lacquered.
4.2
Replacement insert
587
4.2 Shutoff valves and other products for potable water
4.2
588
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
PRODUCTS FOR POTABLE WATER TREATMENT
Potable water filters for horizontal installation optimised in terms of pressure loss for larger
in potable water systems. flow rates as Aquanova Magnum. Filter mesh
Without dead zone, in compact design for sizes from 95 µm to 140 µm.
smaller flow rates as Aquanova Compact or
DN 20, R 3/4, PN 16, with transparent plastic cup DVGW, ACS 6122006
DN 25, R 1, PN 16, with transparent plastic cup DVGW, ACS 6122008
DN 25, Rp 1, PN 16, with transparent plastic cup DVGW, ACS 6122010
DN 20, R 3/4, PN 16, with transparent plastic cup DVGW, ACS 6122506
DN 25, R 1, PN 16, with transparent plastic cup DVGW, ACS 6122508
DN 32, Rp 1 1/4, PN 16, with transparent plastic cup DVGW, ACS 6122510
Filter insert
For Aquanova Compact, mesh size 100 - 120 µm, one-piece, DIN DVGW tested 10 6120591
For Aquanova Magnum, mesh size 80 - 120 µm, with support body, multi-piece, for
10 6125100
industrial applications
For Aquanova Magnum, mesh size 95 - 140 µm, one-piece, DIN DVGW tested 6125101
For Aquanova Magnum, mesh size 250 - 280 µm, with support body, multi-piece, for
10 6125161
industrial applications
For Aquanova Magnum, mesh size 800 - 1000 µm, with support body, multi-piece, for
10 6125163
industrial applications
Filter stocking
Filter stockings can only be used with multi-piece filter inserts. If required, order support body and collar separately.
4.2
591
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
PRODUCTS FOR POTABLE WATER TREATMENT
For Aquanova water filters, DN 6, G 1/8 external thread, set = 2 pieces 6127000
4.2
592
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
PRODUCTS FOR POTABLE WATER TREATMENT
Bypass mixing valves and bypass valves for Inlet and outlet of the softener can be shut off
potable water softening installations in indus- for service work.
try, trade and household.
DN 32 , G 1 ¼, PN 10 ACS 6102010
4.2
Bypass mixing valve with internal thread
Body made of bronze, bonnet made of brass, for large systems.
DN 50 , G 2, PN 10 6102016
593
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
PRODUCTS FOR POTABLE WATER TREATMENT
Bypass valve with internal thread, shutoff valves and draining facilities G 1/4 and G 1/2
For systems with integrated mixing device.
Brass body.
4.2
594
SHUTOFF VALVES AND OTHER PRODUCTS FOR POTABLE WATER
PRODUCTS FOR POTABLE WATER TREATMENT
Hose line
Replacement insert
For Bypass mixing valve DN 25, for setting large flow rates 50 6101053
For bypass mixing valve DN 25 / DN 32, for setting small flow rates 100 6102051
For bypass mixing valve DN 32, for setting large flow rates 10 6102053
For bypass valve and bypass mixing valve DN 25 with flat sealing bonnet, until 07.2004 25 6109551 °
For bypass valve and bypass mixing valve DN 25, with bonnet with O-ring, from 07.2004 25 6109552
4.2
Replacement regulating insert
For bypass mixing valve DN 50, with diaphragm and spring 6109152
Replacement bonnet
For bypass mixing valve DN 50, for setting small flow rates 6109851
4.2
596
Oil
Solar
5
5.1 Products for heating oil installations
Sets 637
Heating oil kits for export............................................................... 638
5.1
600
5.1 Products for heating oil installations
Oil, Solar
601
PRODUCTS FOR HEATING OIL INSTALLATIONS
DEAERATORS AND FILTERS FOR OIL HEATING TECHNOLOGY
C
F
A
D E
602
PRODUCTS FOR HEATING OIL INSTALLATIONS
DEAERATORS AND FILTERS FOR OIL HEATING TECHNOLOGY
Recommendations regarding the conversion of an existing two Recommendation when switching to “bio heating oil” (low-sulphur
pipe system to a one pipe system: heating oil with organic content):
– The suction pipe should be re-routed in the appropriate, smaller – The one pipe system is highly recommended for oil installations.
dimension, as the oil flow rate is usually considerably lower.
Disturbances as a result of occasional air accumulations are thus – Check remaining old construction components to see if they are
avoided. According to DIN 4755, the flow velocity should be suitable for the planned bio proportion and replace if necessary.
approx. 0.2 to 0.5 m/s. – Before filling, the heating oil in the tank should be used up.
Observe the notes on this in the installation instructions and data
sheets. – Tank cleaning with disposal of the residual oil is recommended.
– The installation of a heating oil deaerator, e.g. a Toc-Duo-3 heating – Filter inserts with a large filter surface area should be used, e.g.:
oil filter and heating oil deaerator combination. “opticlean”. This applies especially if no tank cleaning has been
Note: A two pipe filter cannot be used as one pipe filter with return carried out.
flow feed! Reasons:
– Old oil pipes should be removed – Bio proportions (FAME) can dissolve existing deposits, these can
block filter inserts.
Note regarding liquid fuels:
Heating oil is a liquid fuel that is produced from fossil mineral oil. In – Back flowing oil in two pipe systems can adversely affect the shelf
order to conserve fossil deposits, liquid fuels, e.g. from renewable life of the stored product.
raw materials, can be added to the heating oil. – The mixture of used and fresh low-sulphur heating oil may cause
This admixture - “alternative proportions” or “bio oils” - is, for corrosion of the burner’s flame tubes (“metal dusting”).
example: Bio diesel (= FAME = fatty acid methyl ester).
The fatty acids contained in bio oils can damage the seals and hoses
that were common in the past.
New oil fittings are generally designed for a bio proportion of 20 %
and more. Observe the notes.
5.1
603
PRODUCTS FOR HEATING OIL INSTALLATIONS
DEAERATORS AND FILTERS FOR OIL HEATING TECHNOLOGY
The installation is permitted below and above The tank side connection G 3/8 internal thread
the oil level. is suitable for OV compression fittings 6, 8, 10
and 12 mm.
604 Cap = Material deaerator cap System = Pipe system ° Production will be discontinued
Cup = Material filter cup Pressure gauge = Vacuum pressure gauge
Filter = Material filter element
Mesh size = Mesh size filter element
PRODUCTS FOR HEATING OIL INSTALLATIONS
DEAERATORS AND FILTERS FOR OIL HEATING TECHNOLOGY
5.1
Oilpur heating oil filters are used in oil firing tives” or a bio proportion of up to 20 % accord-
systems, which are operated as one pipe sys- ing to DIN SPEC 51603-6. The models with
tem with or without return flow feed or as metal filter cup are also suitable for heating oil
two pipe system. Filters with plastic cups with up to 100 % FAME as well as for various
are generally only approved for suction opera- low-viscosity vegetable oils. All Oilpur heat-
tion, metal filter cups and filter cartridges are ing oil filters with shutoff are supplied with a
also approved for pressurised systems and are bracket.
available optionally or as accessories.
The tank side connection G 3/8 internal thread
All Oilpur heating oil filters are suitable for is suitable for OV compression fittings 6, 8, 10
fuels and combustibles with “alternative addi- and 12 mm.
Oventrop
DIN EN
12514-2
Nominal Connection tank Connection burner Cup* Filter* Mesh size* Item No.
size side side (µm)
Plastic trans- Stainless
DN 10 G 3/8 internal G 3/8 internal 100-150 2123103
parent steel
Plastic trans- Stainless
DN 15 G 1/2 internal G 1/2 internal 100-150 2123104
parent steel
Plastic trans- Sintered
DN 10 G 3/8 internal G 3/8 internal 50-75 2123261
parent plastic
Plastic trans-
DN 10 G 3/8 internal G 3/8 external Felt 50-75 2123503 °
parent
Plastic trans- Sintered
DN 10 G 3/8 internal G 3/8 external 50-75 2123561
parent plastic
Plastic trans- Sintered
DN 10 G 3/8 internal G 3/8 external 25-40 2123871 °
parent plastic
DN 10 G 3/8 internal G 3/8 external Metal PN 16 Paper 5-20 2153554 °
5.1
Oilpur E A R with shutoff for one pipe systems with return flow feed
The heating oil filters with G 3/8 internal thread on the tank side can be connected with Oventrop compression
fittings 6, 8, 10 or 12 mm. The compression fittings must be ordered separately.
Item no. 2121871: long model Magnum
Venting Yes Certification DIN, Ü sign
PU 10
Nominal Connection tank Connection burner Cup* Filter* Mesh size* Item No.
size side side (µm)
Plastic trans- Sintered plas-
DN 10 G 3/8 internal G 3/8 external 25-40 2121871 °
parent tic
Plastic trans- Stainless
DN 10 G 3/8 internal G 3/8 internal 100-150 2122103
parent steel
Plastic trans- Sintered plas-
DN 10 G 3/8 internal G 3/8 external 50-75 2122261
parent tic
Plastic trans- Sintered plas-
DN 15 G 1/2 internal G 1/2 internal 50-75 2122262
parent tic
Plastic trans- Stainless
DN 10 G 3/8 internal G 3/8 external 100-150 2122403
parent steel
Plastic trans-
DN 10 G 3/8 internal G 3/8 external Felt 50-75 2122503 °
parent
Plastic trans- Sintered plas-
DN 10 G 3/8 internal G 3/8 external 50-75 2122561
parent tic
DN 10 G 3/8 internal G 3/8 external Metal Paper 5-20 2152554 °
Nominal size Connection tank side Connection burner side Filter* Mesh size* Item No.
(µm)
5.1
Nominal size Connection tank side Connection burner side Filter* Mesh size* Item No.
(µm)
Oilpur Small heating oil filter with shutoff for one pipe systems
Nominal size Connection tank side Connection burner side Item No.
5.1
The finer Siku filter inserts (25-40 µm) can be recognized by the red bayonet.
Filter cup
Transparent cups made of plastic are only to be used for suction operation.
Filter cup Magnum with filter insert made of sintered plastic 50-75 µm and O-ring 2120891
Adapter
5.1
Union nut
For Oilpur heating oil filters and Toc-Duo-3 heating oil filter and heating oil deaerator combinations 2126600
Tool
Vent hose, 10 m
With hose nozzle for Toc-Duo-3 and Toc-Uno for the removal of outgassings 2142990
Replacement bracket
Replacement handwheel
5.1
611
5.1 Products for heating oil installations
5.1
612
PRODUCTS FOR HEATING OIL INSTALLATIONS
TANK EQUIPMENT FOR OIL HEATING TECHNOLOGY
Fittings for safe filling and venting, as well as with screw connection provide a secure hold
for level detection. for adapter pieces.
Tank caps ensure a secure closure and connec-
tion of the filling hose to the filling pipe of Metal vent caps are particularly durable.
the tank. Tank caps with bayonet according
to EN 14420 part 6 (or part 8 for France) are Fuel gauge locks as well as mechanical and
recommended for a direct connection of the pneumatic tank level indicators are available
filling hose from the tank vehicle. Tank caps for determining the fill level.
Nominal size Connection tank side Connection filling spout Material PU Item No.
Nominal size Connection tank Connection Material Types (according to EN PU Item No.
side filling spout 14420-6)
5.1
Nominal size Connection tank side Connection filling spout Material Item No.
DN 50 Brass 2010716 °
5.1
Vent cap
Variants with dirt strainer for export only (according to DIN 4755, cross-section reductions such as strainers in vent
pipes are not permitted).
The dirt strainers of the variants DN 20 - DN 50 are made of plastic, those of the variants DN 65 and DN 80 are made
of brass.
Nominal size Connection tank side Material Dirt strainer PU Item No.
5.1
Condensate collector
The switching amplifier of the tank truck in EN 12285-1, EN 12285-2, DIN 6624, DIN 6619,
conjunction with the tank filling limiter pre- DIN 6623, and DIN 4119.
vents overfilling of the tank. The tank filling
limiter is a “sensor for tanks with current inter- Type 21301 with fitting for wall mounting
face as part of an overfill protection system of (905), cable length approx. 5 m, preferred
type B and design B1 according to EN 13616”. for above ground tanks according to e.g. DIN
All tank filling limiters are TÜV tested and are 6620, DIN 6625, EN 12573 parts 1-3, EN 13341
marked with CE sign. parts 1-3, EN 13121 parts 1-3 and battery tanks
with general type approval up to 25 single
The 2 types differ in the connection fitting: tanks.
Type 21300 with fitting for pipe mounting
(904), preferred for underground tanks ac- A tank filling limiter of type 21301 is also inclu-
cording to e.g. DIN 6608, DIN 6616, DIN 6617, ded in the Flexo-Bloc item no. 2052351.
Connection tank side Tank height up to Type Probe length Item No.
(mm) (mm)
5.1
Tank filling limiter probe (type 21301), probe length 385 mm, cable length approx. 5 m 2130150 °
Fitting for pipe mounting (904) 2133000 °
Fitting for wall mounting (905) 2133100 °
5.1
Lower connection G ⅜ internal thread and G ½ external thread, upper connection M 18 x 1.5 mm 2073051
With condensate collector and bracket for mounting on the dome cover, hose connections 4 and 6
2073161
mm
Bracket
Made of steel, for mounting the liquid safety device on the dome cover 2076100 °
With outer hose connections 4 and 6 mm, hose connection in the tank 6 mm 2074061
As above, but extended with copper pipe, outer hose connections 4 and 6 mm, hose connection in
2074261
the tank 6 mm
Spacer plate
Is required if the hose line is not routed to the bottom of the tank.
Condensate collector
For systems with PVC inner jackets in which petrol containing ethanol is stored, the brass cup (item no. 2129152) on
the condensate collector is recommended. Ethanol can diffuse through the inner jacket and damage the material of
the transparent cup in the long term.
Hose nozzle
M 18 x 1.5 internal thread, with internal cone x tailpipe for hose with clear width 10 mm 50 2075053 °
M 18 x 1.5 internal thread with internal cone x tailpipe for hose with clear width 4 and 6
100 2075061 °
mm
G 3/8 external thread x tailpipe for hose with clear width 10 mm 50 2075153 °
G 3/8 external thread x tailpipe for hose with clear width 4 and 6 mm 50 2075161 °
G 1/8 external thread x tailpipe for hose with clear width 4 and 6 mm 100 2075261 °
Locknut
5.1
Oventrop
DIN EN
12514-2
Flexo-Bloc
Export models 2053051-2053354:
The export versions comply with German regulations when brass compression fittings are used.
Floating suction No PU 10
Connection tank side Tank height Plastic compres- Return Compression fit- Certifica- Item No.
up to sion fitt.* connec- ting tion
(mm) tion
10 and 12 mm
G 1 external 2,000 - Yes Ü sign 2052151
(brass)
10 and 12 mm
G 1 external 3,000 - Yes Ü sign 2052152
(brass)
10 and 12 mm
G 1 1/2 external 2,000 - Yes Ü sign 2052153
(brass)
10 and 12 mm
G 1 1/2 external 3,000 - Yes Ü sign 2052154
(brass)
G 2 external 2,000 8, 10 and 12 mm Yes - 2053051
G 2 external 3,000 8, 10 and 12 mm Yes - 2053052
G 2 external 2,000 6 and 8 mm No - 2053351
G 2 external 3,000 6 and 8 mm No - 2053352 °
G 1 external 2,000 6 and 8 mm No - 2053353
G 1 external 3,000 6 and 8 mm No - 2053354
5.1
620 Plastic compression fitt. = Compression fitting made of plastic ° Production will be discontinued
PRODUCTS FOR HEATING OIL INSTALLATIONS
TANK EQUIPMENT FOR OIL HEATING TECHNOLOGY
Connection tank side Tank height up Plastic compres- Return con- Floating suc- Certification Item No.
to sion fitt.* nection tion
(mm)
5.1
Plastic compression fitt. = Compression fitting made of plastic ° Production will be discontinued 621
PRODUCTS FOR HEATING OIL INSTALLATIONS
TANK EQUIPMENT FOR OIL HEATING TECHNOLOGY
Tank extraction
Nominal size Pipe connection Material Non-return check valve Certification PU Item No.
Nominal size Pipe connection Material Non-return check valve Certification Item No.
Pipe connection Connection tank side Material Return connection Item No.
Reducer
Made of anthracite plastic.
10 mm 1,250 2050051 °
10 mm 1,500 2050052 °
10 mm 1,600 2050053 °
10 mm 1,750 2050054 °
10 mm 2,000 2050055 °
10 mm 2,500 2050056 ° 5.1
Ripcord
For remote operation of quick-acting shutoff valves, with screws, dowels and seal 2052080 °
Conversion set
5.1
5.1
625
PRODUCTS FOR HEATING OIL INSTALLATIONS
PIPELINE VALVES AND COMPONENTS FOR OIL HEATING TECHNOLOGY
Oilstop siphon protection valves or anti-si- the suction line above the maximum permissi-
phon valves are used as safety devices in oil ble tank level before it reaches a lower level.
pipes according to DIN 4755 to prevent the Both valves have a general type approval
contents of the tank from leaking. (AbZ) and are pressure balanced in the direc-
tion of the tank.
Siphon protection valves must be installed in
5.1
626
PRODUCTS FOR HEATING OIL INSTALLATIONS
PIPELINE VALVES AND COMPONENTS FOR OIL HEATING TECHNOLOGY
Pipeline valves
Both sides G 3/8 internal thread for Oventrop compression fittings 6, 8, 10 and 12 mm Ü sign 2107003 °
Insulating fitting
For protection against harmful effects of galvanic currents, cutting ring compression fitting on both sides (steel,
galvanised). Cutting rings made of brass. For suction operation. TÜV-tested, according to TRbF 521/6.51-2.
6 x 6 mm 2080851 °
8 x 8 mm 2080852 °
10 x 10 mm 2080853 °
12 x 12 mm 2080854 °
15 x 15 mm 2080855 °
18 x 18 mm 2080856 °
Shutoff valve
Straight needle valve made of brass, for pipework PN 16. For use with mineral, heating and hydraulic oils as well as air
PN 6.
G 1/4 DN 8 2091002
6 x 6 mm 2100051 °
8 x 8 mm 2100052 °
10 x 10 mm 2100053 °
12 x 12 mm 2100054 °
15 x 15 mm 2100055 °
Change-over valve
Made of brass (quick acting version), according to DIN EN 12514-2, PN 6, with cutting ring compressing fitting
according to DIN 2353 made of galvanised steel, cutting ring made of brass.
6 x 6 x 6 mm 2102051 °
8 x 8 x 8 mm 2102052 °
10 x 10 x 10 mm 2102053 °
12 x 12 x 12 mm 2102054 °
Temperature range: 0 °C up to 60 °C
Pressure range: -0.6 bar up to 10 bar
5.1
Item No.
Item No.
Item No.
PU Item No.
PU Item No.
Item No.
PU Item No.
Item No.
PU Item No.
Ofix-Oil T-fitting
Made of steel, galvanised with brass cutting ring. DIN 2353 series L.
Support sleeves must be used for copper pipes.
Item No.
Cutting ring connection 6 mm Cutting ring connection 6 mm Cutting ring connection 6 mm 2083551 °
Cutting ring connection 8 mm Cutting ring connection 8 mm Cutting ring connection 8 mm 2083552 °
Cutting ring connection 10 Cutting ring connection 10 Cutting ring connection 10
2083553 °
mm mm mm
Cutting ring connection 12 Cutting ring connection 12 Cutting ring connection 12
2083554 °
mm mm mm
PU Item No.
PU Item No.
10 mm 100 1029651
12 mm 100 1029652
15 mm 50 1029654
18 mm 50 1029656
6 mm 100 2083951
8 mm 100 2083952
5.1
Item No.
Item No.
Item No.
5.1
Up to a max. of 70 °C, the hose lines are also inner layer should be used, for example.
suitable for fuels and combustibles with “alter-
native additives” or a bio proportion of up to Hose lines with galvanised wire braiding PN
20 % according to DIN SPEC 51603-6. 10. Flexible hose lines as connection between
a solid pipeline (e.g. from the filter) and the
For higher bio proportions or temperatures up burner or feeder unit.
to 100 °C, burner hoses with a diffusion tight
8 500 2110051 °
8 750 2110052 °
8 1,000 2110053
8 1,250 2110054 °
8 1,500 2110055
Hose line, both sides G ⅜ union nut and sealing cone, one side straight, other side with 90° elbow
5.1
NI* Hose length Item No.
(mm)
8 500 2110071 °
8 750 2110072 °
8 1,000 2110073 °
Hose line, one side G ⅜ external thread, one side G ⅜ union nut
With sealing cone.
8 500 2110151 °
8 750 2110152 °
8 1,000 2110153 °
8 1,250 2110154 °
8 1,500 2110155 °
Hose line, one side ¼ NPT external thread, one side G ⅜ union nut
With sealing cone.
8 500 2110251 °
8 750 2110252 °
8 1,000 2110253 °
8 1,250 2110254 °
8 1,500 2110255 °
Hose line, one side G ¼ external thread, one side G ⅜ union nut
With sealing cone.
8 300 2110350 °
8 500 2110351 °
8 750 2110352 °
8 1,000 2110353 °
8 1,250 2110354 °
8 1,500 2110355 °
Hose line, both sides steel pipe socket for cutting ring connection
8 8 x 8 mm 300 2110551 °
8 8 x 8 mm 500 2110552 °
8 8 x 8 mm 750 2110553 °
5.1
8 8 x 8 mm 1,000 2110554 °
10 10 x 10 mm 300 2110555 °
10 10 x 10 mm 500 2110556 °
10 10 x 10 mm 750 2110557 °
10 10 x 10 mm 1,000 2110558 °
10 12 x 12 mm 300 2110559 °
10 12 x 12 mm 500 2110560 °
10 12 x 12 mm 750 2110561 °
10 12 x 12 mm 1,000 2110562 °
Hose line, one side G ¼ external thread, one side G ⅜ union nut
With sealing ring.
Hose line for connecting a heating oil deaerator to a pre-installed heating oil filter.
8 300 2162993 °
Hoses with an additional diffusion tight inner layer are resistant to EL heating oil and bio heating oils up to 100 °C.
5.1
Sets 637
Heating oil kits for export............................................................... 638
5.1
637
PRODUCTS FOR HEATING OIL INSTALLATIONS
SETS
Oilpur Heating oil filter, both sides internal thread G 3/8, with stainless steel filter insert
Item no. 2120103
Ofix-Oil Compression fittings 8, 10 and 12 mm, for connection of the heating oil filter to the tank side
Item no. 2127500
Cap DN 50 (in accordance with French standard NF E 29-572, system Guillemin, see also EN 14420-8)
Item no. 2010716
Double nipple G 2
Item no. 2080360
Oil tank installation kit for installation of a two pipe system with plastic tank
Consisting of:
Flexo-Bloc Tank extraction device G 2 x 2000 mm with compression fittings 8, 10 and 12 mm
Item no. 2053051
Oilpur Heating oil filter, both sides internal thread G 3/8, with stainless steel filter insert
Item no. 2120103
Ofix-Oil Compression fittings 8, 10 and 12 mm, for connection of the heating oil filter to the tank side
Art.-Nr. 2127500
Heating oil filter kit for one pipe systems with return flow feed
Consisting of:
Oilpur Heating oil filter, both sides internal thread G 3/8, with stainless steel filter insert
Item no. 2122103
Heating oil filter kit for one pipe systems (without return flow feed)
Consisting of:
Oilpur Heating oil filter, both sides internal thread G 3/8, with stainless steel filter insert
Art.-Nr. 2123103
5.1
639
5.2 Solar thermal energy
640
5.2 Solar thermal energy
5.2
641
SOLAR THERMAL ENERGY
REGUSOL STATIONS
For the connection of a solar circuit. The pump pansion tank, a flow measuring and regulating
circuits enable the solar circuit to be shut off device with shutoff and fill and drain ball valve,
on the return side and prevent self-circulation a wall mounting device and a thermal insula-
via an integrated check valve when the pump tion.
is switched off.
The Regusol pump circuits are characterised
The pump circuits consist of a high-efficiency by a time and space saving installation. A high
pump, a ball valve with integrated check valve degree of functional reliability is ensured by
and thermometer in the return, a safety group maintenance-free components and high-quali-
with safety valve, pressure gauge, fill and drain ty materials.
ball valve and connection possibility of an ex-
Regusol PH-130 DN 25
Regusol PH-180 DN 25
642 Measuring range = Measuring range of the flow measuring and regulating device
SOLAR THERMAL ENERGY
REGUSOL STATIONS
Regusol SH Stations
For the connection of a solar circuit. The sta- bility of an expansion tank, a flow measuring
tions enable the solar circuit to be shut off on and regulating device with shutoff and fill and
the supply and return side and prevent self-cir- drain ball valve, a wall mounting device and a
culation via integrated check valves when the thermal insulation.
pump is switched off.
The Regusol pump circuits are characterised
The stations consist of a high-efficiency pump, by a time and space saving installation. A high
ball valves with integrated check valves and degree of functional reliability is ensured by
thermometers in the supply and return, a safe- maintenance-free components and high-quali-
ty group with safety valve, pressure gauge, ty materials.
fill and drain ball valve and connection possi-
Regusol SH-130 DN 20
5.2
Measuring range = Measuring range of the flow measuring and regulating device 643
SOLAR THERMAL ENERGY
REGUSOL STATIONS
Regusol SH-130 DN 25
Regusol SH-180 DN 25
Regusol SH-180 DN 32
5.2
644 Measuring range = Measuring range of the flow measuring and regulating device
SOLAR THERMAL ENERGY
REGUSOL STATIONS
For the connection of a solar circuit. The sta- fill and drain ball valve and connection possi-
tions enable the solar circuit to be shut off on bility of an expansion tank, a flow measuring
the supply and return side and prevent self-cir- and regulating device with shutoff and fill and
culation via integrated check valves when the drain ball valve, a vent pot, a wall mounting
pump is switched off. A vent pot enables the device and a thermal insulation.
degassing of the heat transfer medium in the
supply pipe. The Regusol pump circuits are characterised
by a time and space saving installation. A high
The stations consist of a high-efficiency pump, degree of functional reliability is ensured by
ball valves with integrated check valves and maintenance-free components and high-quali-
thermometers in the supply and return, a safe- ty materials.
ty group with safety valve, pressure gauge,
Regusol LH-130 DN 20
5.2
Measuring range = Measuring range of the flow measuring and regulating device 645
SOLAR THERMAL ENERGY
REGUSOL STATIONS
Regusol LH-130 DN 25
Regusol LH-180 DN 25
5.2
646 Measuring range = Measuring range of the flow measuring and regulating device
SOLAR THERMAL ENERGY
REGUSOL STATIONS
Regusol ELH-130-RC DN 25
With Regtronic RC electronic controller.
Pump length 130 mm Measuring range* 2 up to 15 l/min
Length 375 mm Max. operating pressure 6 bar
Volume flow sensor No PU 30
Flow rate indicator Yes
Regusol ELH-130-RC-P DN 25
With Regtronic RC-P electronic controller. 5.2
Pump length 130 mm Flow rate indicator No
Length 375 mm Measuring range* 2 up to 40 l/min
Volume flow sensor Vortex Max. operating pressure 6 bar
Measuring range = Measuring range of the flow measuring and regulating device 647
SOLAR THERMAL ENERGY
REGUSOL STATIONS
Regusol ELH-180-RC DN 25
With Regronic RC electronic controller.
Pump length 180 mm Flow rate indicator Yes
Length 425 mm Measuring range* 2 up to 15 l/min
Volume flow sensor No
5.2
648 Measuring range = Measuring range of the flow measuring and regulating device
SOLAR THERMAL ENERGY
REGUSOL STATIONS
The Regusol X stations with heat exchanger tronic volume flow sensor. The secondary side
enable a controlled transfer of thermal ener- consists of a high-efficiency pump, ball valves
gy from a solar circuit (primary circuit) to a with integrated thermometers in the supply
storage cylinder circuit (secondary circuit). The and return, a check valve, a safety valve, a vent
stations enable the solar circuit to be shut off valve and a connection for filling, flushing and
on the supply and return side and prevent self- draining. The circuits are separated by a plate
circulation via integrated check valves when heat exchanger. The station has an integrated
the pump is switched off. The integrated elec- electronic controller, a wall mounting device
tronic controller takes over the control and and a thermal insulation.
monitoring of the solar thermal system.
The Regusol X stations are ideal for buffer
The primary circuit consists of a high-efficien- storage cylinders without direct solar con-
cy pump, ball valves with integrated check nection. They are characterised by a time
valves and thermometers in the supply and re- and space saving installation. A high degree
turn, a safety group with safety valve, pressure of functional reliability is ensured by mainte-
gauge, fill and drain ball valve and connection nance-free components and high-quality ma-
possibility of an expansion tank, connections terials.
for filling, flushing and draining and an elec-
5.2
649
SOLAR THERMAL ENERGY
REGUSOL STATIONS
PU 3
5.2
650
SOLAR THERMAL ENERGY
REGUSOL STATIONS
For copper and precision steel pipe, DN 20, G ¾ union nut, 12 mm, 4-fold 1367393
For copper and precision steel pipe, DN 20, G ¾ union nut, 15 mm, 4-fold 1367395
For copper and precision steel pipe, DN 20, G ¾ union nut, 16 mm, 4-fold 1367396
For copper and precision steel pipe, DN 20, G ¾ union nut, 18 mm, 4-fold 1367397
For copper and precision steel pipe, DN 25, G 1 union nut, 12 mm, 2-fold 1367583
For copper and precision steel pipe, DN 25, G 1 union nut, 15 mm, 2-fold 1367585
For copper and precision steel pipe, DN 25, G 1 union nut, 16 mm, 2-fold 1367586
5.2
For copper and precision steel pipe, DN 25, G 1 union nut, 18 mm, 2-fold 1367587
For copper and precision steel pipe, DN 25, G 1 union nut, 22 mm, 2-fold 1367589
651
SOLAR THERMAL ENERGY
REGUSOL STATIONS
12 mm 100 1029652
15 mm 50 1029654
16 mm 50 1029655
18 mm 50 1029656
22 mm 50 1029657
Tailpipe set DN 20
For connection to Regumaq X-30/XZ-30 and Regusol X.
Tailpipe set DN 32
For connection to Regusol SH-180 DN 32.
Locking shackle
5.2
Check valve
To prevent gravity circulation when the pump is switched off.
Opening pressure 20 mbar, continuous operating temperature 120 °C, short-term starting temperature 160 °C.
With lateral connection for filling and flushing pipes G ¾, G 1 external thread x G 1 external thread 1363051
With hose connection and ball valves on the suction and pressure side 1364250
5.2
For Regusol stations (manufactured from 2015), with safety valve 6 bar 1364192
For Regusol stations (manufactured until 2015), with safety valve 10 bar 1364247
For Regusol stations, 2-15 l/min, G 1 ½ union nut x G 1 for Regusol compression fittings 1364161
For Regusol stations, 7-30 l/min, G 1 ½ union nut x G 1 for Regusol compression fittings 1364162
For Regusol stations, 2-14 l/min, G 1 union nut x G ¾ for Regusol compression fittings 1364163
For Regusol X with Regtronic RX, with connecting cable, 2-40 l/min 1369092
655
SOLAR THERMAL ENERGY
REGUSOL STATIONS
Replacement thermometer
656
SOLAR THERMAL ENERGY
REGUSOL STATIONS
For Regusol-130 DN 25, Grundfos UPM 3 Solar 25-75 PWM C 130 1360589
For Regusol-130 DN 25, Wilo PARA ST 25-130/7-50/iPWM2-9 1360590
For Regusol-180 DN 25, Grundfos UPM 3 Solar 25-75 PWM C 180 1367259
For Regusol-180 DN 25, Wilo PARA ST 25-180/7-50/iPWM2-9 1367260
5.2
657
5.2 Solar thermal energy
5.2
658
SOLAR THERMAL ENERGY
REGTRONIC ELECTRONIC CONTROLLERS
Oventrop electronic controllers ensure an effi- to an intelligent system. The controllers can
cient use of energy in the heating and cooling coordinate different heat generators (including
supply. They enable the control, combination gas boilers, solid fuel boilers or solar thermal
and monitoring of different functions from the systems) to ensure economical operation.
areas of generation, distribution and transfer
Regtronic RC Simple solar controller for controlling a solar thermal system with one collector
Compatible with Datalog CS-BS-6 and CS-BS-1.
Application Solar Potential-free relays 1
Operating voltage 230 V PWM* 2
Sensor inputs 4 Further inputs Pulse inputs V40
Solid-state relays 2
Regtronic RC-P Flexible solar controller for more complex solar thermal systems, heating of potable water and
additional functions
Compatible with Datalog CS-BS-1.
Application Solar Potential-free relays 1
Storage cylinder management PWM* 2
Service water heating
Further inputs Pulse inputs V40
Operating voltage 230 V FlowRotor
Sensor inputs 4 Grundfos Direct Sensor
Solid-state relays 3 Heat meter 2
5.2
Boiler control
Modulating
Item no. Controller Required accessories (0-10 V) On/Off ErP % Class
5.2
Controller location
Regtronic S-bus
Regtronic PSW
5.2
661
SOLAR THERMAL ENERGY
REGTRONIC ELECTRONIC CONTROLLERS
For room temperature measurement, sensor element PT 1000, surface mounting 1152095
Room controller
Temperature sensor
Suitable for all Oventrop controllers.
662
5.2 Solar thermal energy
5.2
663
SOLAR THERMAL ENERGY
SOLAR DIAPHRAGM EXPANSION TANKS
Solar diaphragm expansion tanks are pres- heating, solar and cooling water systems.
sure devices and are used for pressure main- A membrane divides the tank into a water sec-
tenance and volume compensation in closed tion and a gas section with a pressure cushion.
5.2
Solar in-line tanks are pressure devices and are e.g. for roof heating systems with short pipe
installed in closed heating, solar and cooling runs.
water systems in the expansion pipe in front of
diaphragm expansion tanks to protect the dia- They consist of a pressure chamber which is
phragm from inadmissible temperature loads. filled with 100 % heat transfer medium during
This is necessary for solar thermal systems, operation.
5.2
5.2
666
5.2 Solar thermal energy
5.2
667
SOLAR THERMAL ENERGY
OV-FLEX ST PIPES AND CONNECTORS
OV-Flex ST Pipes
OV-Flex ST pipes are quick installation pipes ble for connecting a temperature sensor (e.g.
for flexible roof lead-through and connection PT 1000). Flat seals, union nuts and fixing
of the collector field to the pipe system. rings are included in the scope of delivery. The
stainless steel corrugated pipes can be cut to
The pipes consist of a two-part high-tempera- length individually.
ture resistant insulating jacket with UV-resist-
ant foil coating in the supply and return. Inside The OV-Flex ST pipes are characterised by sim-
the insulating jacket is a two-core sensor ca- ple and time-saving installation.
5.2
For wall or ceiling mounting of the corrugated stainless steel pipe, with fixing material, 4-fold 1361655 °
Connection piece
Double nipple
For lengthening or shortening of corrugated stainless steel pipe, G ¾ union nut, DN 16 1369083 °
For lengthening or shortening of corrugated stainless steel pipe, G 1 union nut, DN 20 1369084 °
5.2
5.2
670
SOLAR THERMAL ENERGY
OKP TUBE COLLECTORS
The OKP tube collectors can be used for hot to evaporate and the vapour to rise into the
potable water preparation, solar backup heat- condenser. The double pipe heat exchanger in
ing, swimming pool heating and also for the the header, in which the condenser is located,
generation of process heat. They can be used transfers the heat to the heat transfer medium
in portrait format with an axis inclination of flowing past. As a result, the vapour conden-
15°- 75° for on-roof installation, free-standing ses and runs back down the heat pipe and the
installation (flat roof installation) or façade in- process is repeated.
stallation.
Due to the high-quality, corrosion-resistant
The tube collectors consist of the vacuum materials used and the high-quality thermal
tubes, a header, a pre-assembled side rail set insulation (“thermos flask” principle) the tube
for quick and easy mounting and a tube holder collectors achieve a particularly high degree of
(foot rail). The tube collector is a heat pipe efficiency. In addition, they are characterised
tube collector. The heat is transferred from the by a modular design that allows for easy one-
absorber via an aluminium fin to the heat pipe. man installation.
This causes the liquid inside the heat pipe
Width collector Gross surface Collector aperture surface area Weight Item No.
(mm) (m²) (m²) (kg)
Width collector Gross surface Collector aperture surface area Weight Item No.
(mm) (m²) (m²) (kg)
5.2
OKP Cover
For covering the junction between two tube collectors.
5.2
For coupling OKP tube collectors, 100 mm, DN 20, 2-fold 1361622 °
OKP U-bend
For OKP tube collectors, for connecting the supply and return 1361295 °
Solar EPDM insulation layer 2 x 0.5 m, with tear-resistant foil and adhesive roll 1361623 °
Braiding set
Tissue made of polyamide 6.6 as additional bird pecking protection in the open. 5.2
OKP
OKPAnschlussmöglichkeiten
Connection options
Edelstahlwellrohr
Stainless steel corrugated pipe
DN20
DN 201361653/54
1361653/54 1361622
1361622 1361295
1361295
OKP-10
OKP-10 OKP-10
OKP-10
Connection of corrugated
Anschluss von Well- Double nipple
Doppelnippel Roof lead-through
Dachdurchführung
pipe rohr
with mit
G 1Gunion
1 ÜMnut 1369098
1369098 DN
DN20201361672
1361672 1361622
1361622 1361295
1361295
OKP-10
OKP-10 OKP-10
OKP-10
Connection of corrugated
Anschluss von Well- Double nipple
Doppelnippel Roof lead-through
Dachdurchführung
pipe rohr
with mit
G ¾Gunion
¾ ÜMnut 1369096
1369096 DN
DN16
161361671
1361671
OKP-10
OKP-10 OKP-10
OKP-10
Smooth
Glattrohr Compression Compression
Klemmring- Klemmring Roof lead-through
Dachdurchführung
pipe fitting
verschraubung fitting 1369078
1369078 DN 16
DN 16 1361671
1361671
Connection of corrugated
Anschluss von Well- Connection piece
Übergangsstück
pipe with
rohrGmit
1 union nut
G 1 ÜM DN 20
DN 20 1361681
1361681 1361622
1361622 1361295
1361295
OKP-10 OKP-10
OKP-10
Connection of corrugated
Anschluss von Well- Connection piece
Übergangsstück
pipe with
rohrGmit
¾G union
¾ ÜMnut DN 16
DN 16 1361680
1361680
5.2
5.2
675
SOLAR THERMAL ENERGY
OKF FLAT-PLATE COLLECTORS
The OKF-CK22 flat-plate collectors can be optimal energy yield and low pressure loss, a
used for hot potable water preparation, solar rear wall insulation and a circumferential frame
backup heating and swimming pool heating. insulation made of mineral wool and a UV-re-
They can be used in landscape or portrait for- sistant EPDM glass seal.
mat for on-roof installation or free-standing in-
stallation (flat roof installation). In-roof instal- Due to the high-quality materials used, the
lation in portrait format is also possible. flat-plate collectors achieve a high degree of
efficiency. In addition, they feature plug-in
The flat-plate collectors have a collector cover connections and pre-assembled rail systems
with matt anti-reflective glass for 96 % light and are therefore characterised by simple
transmission, a laser welded aluminium dou- “plug and play” installation.
ble harp absorber with copper pipe register for
Item No.
1361340 °
5.2
The OKF-CS22 flat-plate collectors can be rear wall insulation and a circumferential frame
used for hot potable water preparation, solar insulation made of mineral wool and a UV-re-
backup heating and swimming pool heating. sistant EPDM glass seal.
They can be used in landscape or portrait for-
mat for on-roof installation or free-standing in- Due to the high-quality materials used, the
stallation (flat roof installation). flat-plate collectors achieve a high degree of
efficiency. In addition, they feature plug-in
The flat-plate collectors have transparent solar connections and pre-assembled rail systems
safety glass, a laser welded aluminium double and are therefore characterised by simple
harp absorber with copper pipe register for “plug and play” installation.
optimal energy yield and low pressure loss, a
Item No.
1361345 °
5.2
The OKF-MQ25 flat-plate collectors can be sure loss, a rear wall insulation and a circum-
used for hot potable water preparation, solar ferential frame insulation made of mineral
backup heating and swimming pool heating. wool and a UV-resistant EPDM glass seal.
They can be used in landscape format for on-
roof installation or free-standing installation Due to the high-quality materials used, the
(flat roof installation). flat-plate collectors achieve a high degree of
efficiency. In addition, they feature plug-in
The flat-plate collectors have a highly trans- connections and pre-assembled rail systems
parent solar safety glass, a laser welded alu- and are therefore characterised by simple
minium serpentine absorber with copper pipe “plug and play” installation.
register for optimal energy yield and low pres-
Item No.
1361440 °
5.2
For OKF-CK22, for pan tiled roofs, basic set (for two collectors) 1361391 °
For OKF-CK22, for pan tiled roofs, extension set 1361392 °
For OKF-CK22, for plain tiled and slate roofs, basic set (for two collectors) 1361393 °
For OKF-CK22, for plain tiled and slate roofs, extension set 1361394 °
For OKF-CK22/CS22, mounting set with 8 clamping brackets, screws and dowels 1361289 °
For OKF-CK22/CS22, basic set portrait format (for one collector) 1361387 °
5.2
For OKF-CK22/CS22, extension set portrait format 1361388 °
For OKF-CK22/CS22, single set, landscape format (for one collector) 1361389 °
Mounting set for portrait format, with 10 clamping brackets and 14 rivets 1361228 °
Mounting set for landscape format, with 16 clamping brackets and 24 rivets 1361229 °
Trapezoidal metal sheet for portrait format (1300 x 1035 x 0,75) 1361283 °
Trapezoidal metal sheet for landscape format (1035 x 1000 x 0,75) 1361284 °
Item no. 1 2 3 4 5 6
Trapezoidal metal sheet for portrait format (1300 x 1035 x 0,75) 1361283 2 4 6 8 10 12
Mounting set for portrait format (10 x clamping bracket, 14 x rivet) 1361228 2 3 4 5 6 7
Freestanding installation in portrait format (basic set) 1361387 1 1 1 1 1 1
Freestanding installation in portrait format (extension set) 1361388 – 1 2 3 4 5
Item no. 1 2 3 4 5 6
Trapezoidal metal sheet for landscape format (1035 x 1000 x 0,75) 1361284 4 8 12 16 20 24
Mounting set for landscape format (16 x clamping bracket, 24 x rivet) 1361229 1 2 3 4 5 6
Item no. 1 2 3 4 5 6 7 8 9 10
Trapezoidal metal sheet for landscape format
1361284 2 3 4 5 6 7 8 9 10 11
(1035 x 1000 x 0,75)
Mounting set for landscape format
1361229 1 2 3 4 5 6 7 8 9 10
(16 x clamping bracket, 24 x rivet)
Freestanding installation in landscape format (basic set) 1361486 1 1 1 1 1 1 1 1 1 1
Freestanding installation in landscape format (extension set) 1361487 – 1 2 3 4 5 6 7 8 9
5.2
5.2
For OKF-MQ25, for collector fields with more than 6 collectors 1361448 °
5.2
5.2
683
SOLAR THERMAL ENERGY
SOLCOS SOLAR PACKAGES
5.2
6
6.1 System solutions for monitoring and automation
6.1
690
6.1 System solutions for monitoring and automation
Smart Home,
Smart Building
691
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
The various DynaTemp systems enable the automation of residential buildings. In addition to the Oventrop control
control and regulation processes in the areas of heat units (DDC), components such as room thermostats,
generation, heat distribution and transfer as well as potable actuators, control valves and stations can be integrated.
water hygiene and circulation of larger residential and non-
Operation
Interfaces: TCP / IP, BACnet IP, Modbus TCP
Communication
DDC (Oventrop, Siemens, Honeywell, Kieback & Peter, Sauter, ...)
centres
Sensors /
Actuators
Valves,
controllers,
regulators
Areas of
application
Room Stations & Storage Potable water
climate cylinders
6.1
692
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
For the connection of 31 C-bus field modules, operating/bus voltage 24 V, 50 Hz, surface mounting 1153350
For the connection of 62 C-bus field modules, operating/bus voltage 24 V, 50 Hz, surface mounting 1153351 °
Transformer
For power supply of the DDC, field modules, relay modules and circulation valves.
6.1
DDC CW-BS
DDC CW-BSfür forden
automatic thermal
automatischen balancing Abgleich
thermischen
and für
und thermal disinfection
die thermische in potableinwater
Desinfektion circulation systems
Trinkwasser-Zirkulationsanlagen
ww
ww
W-LAN
WLAN
ww
BMS*
GLT
Internet
Internet
**
TCP/
TCP/IP
IP
BACnet
BACnetIP
IP
Management level/
Managementebene/
Automation level
Automationsebene
A DDC CW-BS
DDC CW-BS A DDC CW-BS
CW-BS
C-bus/
C-Bus/ C-bus/
C-Bus/
24V
24VAC
AC 24VAC
24V AC
Room level
Raumebene
B
F
F
PWH-C
TWZ
max. 31/62
max. 31/62
D E
TWW
PWH field modules
Feldmodule
H FM
230V ~~
230V
G D E
E Plus
C
II max. 31/62
max. 31/62
0-10V
field module
0-10V
Feldmodule
230V ~
230V
* Integration into a building management system from other suppliers (e.g. Honeywell, Kieback & Peter, Sauter, Siemens, etc.) is possible via the standardised BACnet IP interface
** Für den Zugriff auf die DDC sind Routerkonfiguartionen erforderlich, z. B. Portforwarding
** Router configurations are required for access to the DDC, e.g. port forwarding
A DDC CW-BS Control unit F Aquastrom KFR Free-flow valve with backflow preventer
6.1
B Aquastrom DT Regulating valve including field module G Optibal TW Ball valve for potable water
with actuator 24 V, 0 - 10 V and temperature sensor H Circulation pump
C FM-CW Plus Field module for connecting sensors and pumps I PT 1000 Storage cylinder temperature sensor
D Aquastrom F Free-flow valve
E Temperature sensor G 1/4
694
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
Aquastrom DT Electronic circulation regualting valve with internal thread and FM-CW K field module
For potable water systems PN 10, max. water temperature 90 °C.
DN 15, Rp ½ x Rp ½ 1150004
DN 20, Rp ¾ x Rp ¾ 1150006
DN 25, Rp 1 x Rp 1 1150008
Aquastrom DT Electronic circulation regulating valve with flat sealing external thread and FM-CW K field module
For potable water systems PN 10, max. water temperature 90 °C.
DN 15, G ¾ x G ¾ 1150104
DN 20 , G 1 x G 1 1150106
DN 25, G 1 ¼ x G 1 ¼ 1150108
6.1
695
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
Transformer
For power supply of the DDC, room modules, thermostats and actuators.
6.1
696
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
DDC CR-BSX Control unit for temperature control with transmission of control signals by radio
(EnOcean) and by cable
WLAN
w
w
w
BMS
Internet
TCP/ IP
BACnet IP
Management level/
Automation level A DDC CR-BSX
C-bus/ C-bus/
24V AC 24V AC
O J K
J
C M
B
Room level I
Decentralised control RM RM H L L
and temperature D D
setback of F G
conventional
thermostats 8-fold 8-fold
RM RM
K
N N
C C
N N I
RM RM
E E E E
B H
O J
C R
Q Q I M
I
H RM
Room level S S
R
Central control via the G
DDC with the help of E
sensors and actuators 8-fold
Supply Distributor/ RM
Return collector
J K
C Q Q C
I Distributor/ Supply R
collector
Return
H RM
S S
R
* Integration into a building management system from other suppliers (e.g. Honeywell, Kieback & Peter, Sauter, Siemens, etc.) is possible via the standardised BACnet IP interface
A DDC CR-BSX Control module H RM-C F Wireless room module, flush O Wired motion detector (on site)
B RM-C K Room module, flush mounting, mounting, 1-fold P FM-C WS Outside temperature sensor
wired, 1-fold I FK-C F Solar powered wireless window Q RBG-C K Room controller, surface mounting,
C Wired window contact (on site) contact wired
J BWM-C F Wireless motion detector 6.1
D Uni LHZ Thermostat R RBG-C F Solar powered wireless room
E Aktor T 2P Electrothermal actuator, K SecuSignal Window handle of the company controller
24 V, two point Hoppe (on site) S Electrothermal actuator, 0 - 10 V or two
F RM-C K8 Room module, surface mounting, L Uni FHZ Thermostat with remote control point
wired, 8-fold M RP-C F Wireless repeater, flush mounting,
G RM-C F 8 Wireless room module, flush 230 V
mounting, 8-fold N Room thermostat with setback input, 24 V
697
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
698
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
Room thermostat
With nominal value setting device. For connecting electrothermal actuators (two point “normally closed”).
PU 25
6.1
Solar powered, white (similar to RAL 9003), EnOcean Equipment Profile D5-00-01 1153070
6.1
6.1
701
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
Datalog CS-BS-1
For collecting and reading out of the data of a controller. System visualisation of various controllers and components
possible via the Oventrop Portal (web browser).
Datalog CS-BS-6
For data collection and parameterisation of up to six controllers and for integration into a building automation
system via BACnet IP.
6.1
*reading only
6.1
703
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
B WLAN
W-LAN
D
www.portal.oventrop.com
www.portal.oventrop.com
Internet
TCP / IP
IP
IP
TCP / IP
m
pp..ccoo
t o
rro WLAN
W-LAN
nn t
vvee
D
D
a l.lo.o
a
rtrt
ppoo F
ww. .
ww
ww
A
A
Remote accessüber
Fernzugriff via the
dasOventrop
Oventrop portal on Internet
Portal im the internet
Cold water
Kaltwasser
S-bus
S-Bus
Heat generator
Wärmeerzeuger
E
6.1
704
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART BUILDING SYSTEM SOLUTIONS
Sensor LW TH
Suitable for all Oventrop controllers.
For wireless room modules item no. 1153101 / 21, 55 x 55 mm, white (RAL 9010) 1153170 °
6.1
Reinforcing cap
For DynaTemp CR-BSX. For the protection against vandalism.
For Uni LH, LHZ and LA thermostats, not lockable, white (RAL 9010) 10 1011865
For Uni LH, LHZ and LA thermostats, lockable, white (RAL 9010) 10 1011866
For electrothermal actuators, including special valve adapter with connection thread M 30
1012450
x 1.5 for installation
6.1
706
6.1 System solutions for monitoring and automation
6.1
707
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART HOME SYSTEM SOLUTIONS
wibutler gateway
R-Con
Wireless receiver
mote 420
Wireless actuator Strong partners for a smart home:
6.1
www.wibutler.com/alliance
R-Tronic (EnOcean)
Wireless thermostat
708
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART HOME SYSTEM SOLUTIONS
R-Con Multichannel wireless receiver for surface heating (proprietary radio communication)
Time programme adjustable with R-Tronic wireless thermostats. Item no. 1150770 / 72 additionally with pump and
burner logic. To be installed in a cabinet, the protective housing item no. 1150776 (see “R-Con Accessories”) can be
used alternatively.
Tension 230 V Communication Proprietary radio
Control Two point / PWM Installation Carrier rail (DIN EN 60715 TH35)
With input for dew point monitoring, cooling mode is interrupted if the dew point is exceeded 1150774
6.1
Solar powered, white (similar to RAL 9003), EnOcean Equipment Profile D5-00-01 1153070
6.1
ADVANTAGES
+ Automatic calculation of the required volume flows for + Presetting of the valves in the riser is no longer
each radiator and automatic presetting of the Q-Tech necessary
valves via the mote 420 + Hydraulically balanced heating system at full and
+ Manual setting of the thermostatic valves at the partial load
radiator is no longer necessary + Long battery life, as control commands from the mote
+ No need for pipe network calculation and balancing of 420 are only carried out for the room temperature
the risers control
6.1
712
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART HOME SYSTEM SOLUTIONS
6.1
R-Con Multichannel wireless receiver for surface heating (proprietary radio communication)
Time programme adjustable with R-Tronic wireless thermostats. Item no. 1150770 / 72 additionally with pump and
burner logic. To be installed in a cabinet, the protective housing item no. 1150776 (see “R-Con Accessories”) can be
used alternatively.
Tension 230 V Communication Proprietary radio
Control Two point / PWM Installation Carrier rail (DIN EN 60715 TH35)
Dew point monitoring, cooling mode is interrupted if the dew point is exceeded 1150774
6.1
714
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART HOME SYSTEM SOLUTIONS
Solar powered, white (similar to RAL 9003), EnOcean Equipment Profile D5-00-01 1153070
6.1
Cover frame
For R-Tronic wireless thermostats.
PU 50
PU 50
6.1
716
SYSTEM SOLUTIONS FOR MONITORING AND AUTOMATION
SMART HOME SYSTEM SOLUTIONS
Antenna extension
For R-Con multichannel wireless receiver.
With SMA screw terminal, antenna length 1 m, surface mounting, white glossy (RAL 9003) 1150777
6.1
717
6.2 Components for control, regulation and the
building management system (BMS)
Actuators 730
Aktor T Electrothermal actuators................................................... 731
Aktor T Accessories........................................................................ 733
Aktor M Electromotive actuators................................................... 734
Aktor M Accessories....................................................................... 737
Actuators with radio interface........................................................ 738
Controllers 739
Regtronic Electronic controllers..................................................... 740
Regtronic Accessories.................................................................... 744
6.2
718
6.2 Components for control, regulation and the building
management system (BMS)
6.2
719
COMPONENTS FOR CONTROL, REGULATION AND THE BUILDING MANAGEMENT SYSTEM (BMS)
ROOM THERMOSTATS
ClimaCon F 90 for two pipe applications, heating only/ cooling only, slave
ClimaCon F 210 for two pipe applications, heating only / cooling only, master
Switching between time programme and manual mode possible.
Control Two point / PWM Operation At the room thermostat
Installation Surface mounting With smartphone app
Setback* Via time programme (adjustable in the Communication Bluetooth
app)
Via Eco button at the room thermostat
6.2
6.2
Room thermostats are used in conjunction ing applications by using a different actuator
with actuators for individual room tempera- (e.g. “normally closed” instead of “normally
ture control in heating systems. The temper- open”).
ature is set at the room thermostat. Depend-
ing on the room thermostat used, the temper- Oventrop offers room thermostats for surface-
ature is reduced via an adjustable time pro- and flush-mounted installation, with or with-
gramme or an external time switch. out display.
Room thermostats can also be used for cool-
Room thermostat for two pipe applications, with concealed temperature setting, surface mounting
Room thermostat for two pipe applications, with clock, surface mounting
6.2
Room thermostat for two pipe applications, with display, flush mounting
6.2
Room thermostats are used in conjunction mostat can also be used in three or four pipe
with electromotive or electrothermal actuators systems and has an adjustable neutral zone
for individual room temperature control in between heating and cooling stage. The tem-
heating and cooling systems. This room ther- perature is set at the room thermostat.
6.2
724
COMPONENTS FOR CONTROL, REGULATION AND THE BUILDING MANAGEMENT SYSTEM (BMS)
ROOM THERMOSTATS
6.2
FloorCon Electrical connecting block with automatic hydronic balancing for surface heating
FloorCon F 200, without room allocation, connection of 6 room thermostats / 8 actuators, 230 V 1400984 +
FloorCon F 300, with room allocation, connection of 10 room thermostats / 12 actuators, 230 V 1400985 +
6.2
Aktor T 2P Electrothermal actuator, two point control for FloorCon connecting block
With pre-mounted plug for direct connection to the FloorCon connecting block.
Installation position Any
Installation Plug-in connection with valve adapt-
er
Sensor LW TH Electric pipe contact safety switch with concealed temperature setting
6.2
R-Tronic (EnOcean)
6.2
R-Tronic Accessories
Cover frame
PU 50
6.2
729
6.2 Components for control, regulation and the building
management system (BMS)
Actuators 730
Aktor T Electrothermal actuators................................................... 731
Aktor T Accessories........................................................................ 733
Aktor M Electromotive actuators................................................... 734
Aktor M Accessories....................................................................... 737
Actuators with radio interface........................................................ 738
6.2
730
COMPONENTS FOR CONTROL, REGULATION AND THE BUILDING MANAGEMENT SYSTEM (BMS)
ACTUATORS
6.2
6.2
Aktor T Accessories
Valve adapter
PU 5
Reinforcing cap
6.2
733
COMPONENTS FOR CONTROL, REGULATION AND THE BUILDING MANAGEMENT SYSTEM (BMS)
ACTUATORS
Electromotive actuators are used for heating, tors/collectors (except for item no. 1012710 /
ventilation and air conditioning. Amongst oth- 11), radiant heating ceilings, cooling ceilings
ers, the actuators can be used for room tem- and induction units.
perature control. They can be used, for exam-
ple, with conventional radiators, radiators with Oventrop offers electromotive actuators with
integrated valve sets, heating circuit distribu- and without communication interfaces.
Tension Electrical emergency control function Additional two point / three point Position feedback Item No.
control
Aktor M two point and three point control, connection thread M 30 x 1.5
Cable* 1.5 m
Description Without valve anti-blocking function
Mode of operation not adjustable
Zero point detection
230 V 1012729
Aktor M two point control, with short operating time (3 s), connection thread M 30 x 1.5
Cable* 1.5 m
Description Without valve anti-blocking function
Mode of operation adjustable
Aktor M steady control with 0 - 10 V or two point / three point control, squeeze connection
For two-way valve item no. 11308.. and 16708.. DN 15 to DN 50.
Cable* 1.2 m
Descrip- Automatic valve anti-blocking function
tion With position feedback signal 0 - 10 V
Characteristic line adjustable (linear, equal
percentage)
24 V 1158011
Aktor M steady control with 0(2) - 10 V or three point control, squeeze connection
For Cocon QTR / QFC DN 40 to DN 100.
Description Characteristic line linear
20 mm stroke with adapter
With position feedback signal 0 - 10 V
24 V 1158020
Aktor M steady control with 0(2) - 10 V resp. 0(4) - 20 mA or two point / three point control, squeeze connection
For Cocon QTR / QFC DN 40 to DN 100.
Description 20 mm stroke, spring return and adapter
With position feedback signal 0 - 10 V
Characteristic line linear
6.2
Aktor M steady control with 0 - 10 V, 4 - 20 mA or two point / three point control, squeeze connection
For Cocon QFC DN 125 to DN 200 and for two-way valves DN 65 to DN 150.
Descrip- Characteristic line adjustable (linear, square-
tion law, equal percentage)
With position feedback signal 0 - 10 V
6.2
Aktor M Accessories
For connection to the supply voltage (230 V), pluggable module 1158033
Resistor 0 / 4 mA
For Aktor M 0 - 10 V (item no. 1158020).
6.2
Electronic battery operated actuator for room actuator is configured in the Smart Home sys-
temperature control with interface to mobile tem.
devices.
The mote 420 wireless actuator with EnOcean The mote 200 wireless actuator offers a stand-
interface can be used in combination with R- alone solution. The actuator with Bluetooth in-
Tronic wireless thermostats or be integrated terface is configured via a mobile terminal or
into Smart Home systems (e.g. wibutler). The directly at the actuator.
6.2
Controllers 739
Regtronic Electronic controllers..................................................... 740
Regtronic Accessories.................................................................... 744
6.2
739
COMPONENTS FOR CONTROL, REGULATION AND THE BUILDING MANAGEMENT SYSTEM (BMS)
CONTROLLERS
Electronic controllers from Oventrop ensure telligent system. The controllers can take over
efficient use of energy for heating and cool- the coordination of different heat generators
ing. They enable the control, combination and (amongst others gas boilers, solid fuel boilers
monitoring of various functions in the areas of or solar thermal systems) to ensure economi-
generation, distribution and transfer to an in- cal operation.
Regtronic RH weather-compensated heating circuit controller for variable/constant temperature heating circuit
Compatible with Datalog CS-BS-6, CS-BS-1 and Regtronic KM-TCP. Extendable by a maximum of 5 extension mod-
ules.
Application Heating circuit control Solid-state relays 3
Heat generator activation Electromechanical relays 2
Solid fuel boiler
Service water heating Potential-free relays 1
Boiler control
Item Modulating
no. Controller Required accessories (0-10 V) On/Off ErP % Class
Adapter cable
1152083 2.0 II
1152086
Regtronic RH
1152083 1.5 III
Adapter cable
1152080 4.0 VI
1152086
Regtronic EM Extension module for the control of additional variable/constant temperature heating circuits
For extening the Regtronic controller by 6 sensor inputs and 5 relay outputs.
Operating voltage 230 V Product compatible to Regtronic RH
Sensor inputs 6 Regtronic RM
Regtronic RS
Solid-state relays 4
Potential-free relays 1
Weather-compensated control of 2 variable and 2 constant temperature heating circuits with heat demand (e.g. via a
conventional boiler, solid fuel boiler or heat pump) consisting of the Regtronic RH heating circuit controller with outdoor
sensor and Regtronic EM extension module.
Extension
oventrop
Outdoor A B
sensor Regtronic RH
S-bus
Heat demand
Pump heating circuit 1
T supply T supply
Pump heating circuit 4
D E
Pump heating circuit 2 D E
Mixing valve heating Mixing valve heating
circuit OPEN circuit OPEN
Boiler sensor
G C C
Boiler
F
Extension
741
COMPONENTS FOR CONTROL, REGULATION AND THE BUILDING MANAGEMENT SYSTEM (BMS)
CONTROLLERS
Regtronic RC-P Flexible solar controller for more complex solar thermal systems, heating of potable water and
additional functions
Compatible with Datalog CS-BS-1.
Application Solar Solid-state relays 3
Storage cylinder management Potential-free relays 1
Service water heating
PWM* 2
Operating voltage 230 V
Heat meter 2
Sensor inputs 4
Further inputs Pulse inputs V40
FlowRotor
Grundfos Direct Sensor
Regtronic RC Simple solar controller for controlling a solar thermal system with one collector
Compatible with Datalog CS-BS-6 and CS-BS-1.
Application Solar Solid-state relays 2
Operating voltage 230 V Potential-free relays 1
Sensor inputs 4 PWM* 2
Further inputs Pulse inputs V40
6.2
Regtronic RS extension module for the control of the Regucor WH energy storage centre and other system
components
Compatible with Datalog CS-BS-6 and CS-BS-1.
Application Heating circuit control Solid-state relays 13
Heat generator activation Potential-free relays 1
Solid fuel boiler, solar
Service water heating PWM* 4
Storage cylinder management PWM switchable 0 - 10 V* Yes
Operating voltage 230 V Heat meter 7
Sensor inputs 12 Product compatible to Regtronic EM
Further inputs Pulse inputs V40
FlowRotor
Grundfos Direct Sensor
Regtronic RD-W System controller for the integration of the Regudis W dwelling stations into the heat supply
Flow temperature and differential pressure control with demand recognition 1342093
6.2
Regtronic Accessories
Sensor LW TH
Suitable for all Oventrop controllers.
1 2 3 4 20
Example: Distribution of a temperature sensor (outside temperature sensor item no. 1152099)
to up to 20 Regtronic RH heating circuit controllers (item no. 1152080/1152083)
6.2
744
COMPONENTS FOR CONTROL, REGULATION AND THE BUILDING MANAGEMENT SYSTEM (BMS)
CONTROLLERS
Room controller
Suitable for Regtronic RH, RH-HT, EM, RM and RS. With operating mode switch, remote control and room tempera-
ture sensor.
For room temperature measurement, sensor element PT 1000, surface mounting 1152095
6.2
Controller location
For solar controller Regtronic RC / RC-P.
For connecting differential pressure and temperature sensors to the pipework 1357291
For connecting temperature sensors to the pipework 1357292
6.2
746
Service and data
7
7.1 Service
Services 756
Rental devices................................................................................. 757
Service............................................................................................ 758
7.1
750
7.1 Service
Service and
data
751
SERVICE
SYSTEM DESIGN
Basic
Basic plus
Premium
7.1
752
SERVICE
SYSTEM DESIGN
7.1
753
SERVICE
SYSTEM DESIGN
Basic
Premium
7.1
754
SERVICE
SYSTEM DESIGN
New construction
The heating load calculation is limited to residential buildings with a maximum of 10 dwelling units.
Refurbishment
The heating load calculation is limited to residential buildings with a maximum of 10 dwelling units.
7.1
755
7.1 Service
Services 756
Rental devices................................................................................. 757
Service............................................................................................ 758
7.1
756
SERVICE
SERVICES
Rental devices
Support by Oventrop service technicians for introduction and training, assistance and/or supervision for use and
handling of the measuring device.
Rental of a measuring device. A measuring device for the regulation of double regulating and commissioning valves
can be rented from Oventrop GmbH & Co. KG.
With interfaces for communication with commercially available smartphones, tablets and PCs 1069278
7.1
757
SERVICE
SERVICES
Service
1. SERVICE
Catalogue
Seminars
Slide rule
7.1
758
SERVICE
SERVICES
OVplan
Software for system calculation for heating, cooling, potable water, surface heating
and Regudis dwelling stations.
OVe.r.p.
Software for calculating the ErP energy efficiency class of compound systems.
OVsol
OVselect
Oventrop App
Application for
- iOS
- Android
7.1
759
SERVICE
SERVICES
BIM/CAD Data
- Revit
- DWG
- VDI 3805
ETIM Classifications
- Heating
- Potable water
- Surface heating
- Solar thermal energy
- Storage cylinders
Formats:
-Excel
- Datanorm
- 2ba
7.1
760
7.2 General information
Index 765
Alphabetical index.......................................................................... 766
Article number, EAN code.............................................................. 769
761
7.2
7.2 General information
763
7.2
GENERAL INFORMATION
GENERAL INFORMATION
IMPRINT
Print:
BasseDruck GmbH
Leimstr. 54-58
58135 Hagen, Deutschland
764
7.2
7.2 General information
Index 765
Alphabetical index.......................................................................... 766
Article number, EAN code.............................................................. 769
765
7.2
GENERAL INFORMATION
INDEX
Page Page
A Connection set for external thread - for products without union nut
Accessories and spare parts........................................................... 358 and sealing ring...............................................................................377
Accessories - OV Measuring system.............................................. 322 Connection sets for Cocon QTZ PN 25..........................................379
Actuators........................................................................................ 202 Connection technology Accessories and spare parts.................... 136
Actuators Accessories....................................................................204 Control sets for surface heating..................................................... 192
Actuators with radio interface..................................................56, 738 Copert and Copex Plastic pipes......................................................170
ADV 9 Thermostatic valves.............................................................. 83 Copipe HSC Multi-layer composite pipes....................................... 172
AF Thermostatic valves....................................................................88 CV 9 Thermostatic valves................................................................. 81
Air vents.......................................................................................... 374
Aktor M Accessories............................................................... 297, 737 D
Aktor M Electromotive actuators.....................................54, 294, 734
Design of Cofloor surface heating..................................................752
Aktor T Accessories.................................................................. 53, 733
Design of solar thermal Solcos.......................................................754
Aktor T Accessories and spare parts..............................................293
Differential pressure relief valves................................................... 277
Aktor T Electrothermal actuators......................................51, 292, 731
Dirt separators................................................................................ 372
AQH Thermostatic valves................................................................ 68
Distributors / Hydraulic separators Accessories and spare parts. 422
AQ Thermostatic valves................................................................... 66
Domestic water stations and heating system filling stations........575
Aquamodul Accessories and spare parts...................................... 584
Domestic water stations and heating system filling stations Spare
Aquamodul Distributor system for potable water.........................582
parts................................................................................................ 576
Aquanova Water filters...................................................................589
DyanTemp CR-BSX for decentralised and central individual room
Aquanova Water filters Accessories and spare parts.....................591
temperature control....................................................................... 696
Aquastrom C Accessories and spare parts.................................... 541
DynaTemp CS-BS for networking of stations for heat generator/
Aquastrom C Static control valves................................................. 539
heating circuit and solar thermal energy....................................... 702
Aquastrom F Free-flow valves........................................................554
DynaTemp CW-BS for automatic thermal balancing in potable water
Aquastrom FR Free-flow valves with backflow preventer............. 561
circulation systems......................................................................... 693
Aquastrom G Frost-proof outdoor tap...........................................578
Aquastrom KFR Combined free-flow valves with backflow prevent-
er..................................................................................................... 558 E
Aquastrom K Thermostatic cold water circulation valves............. 532 EQ Thermostatic valves....................................................................69
Aquastrom T plus Thermal circulation valves................................529 E Thermostatic valves...................................................................... 84
Aquastrom UP Flush-mounted free-flow valves............................562 Expa-Con Cap valves...................................................................... 441
Aquastrom UP-MS Water meter installation sets.......................... 577
Aquastrom UP-Therm Flush-mounted circulation valves..............533
Aquastrom VT Thermal circulation valves..................................... 527 F
A Thermostatic valves......................................................................86 Fill and drain cocks Accessories and spare parts...........................349
AV 9 Thermostatic valves.................................................................77 Filling and venting, filling level........................................................613
AZ V Thermostatic valves................................................................ 90 Flexo-Bloc Tank extraction systems...............................................620
Flush-mounted free-flow valves Accessories and spare parts...... 566
Flypass 4TZ Basic fitting................................................................ 305
B Flypass Accessories........................................................................308
Ball valves DZR............................................................................... 339 Flypass sets.....................................................................................306
Brawa-Mix Accessories and spare parts.........................................574 Free-flow and KFR valves Accessories and spare parts.................564
Brawa Mix Thermostatic service water mixing valves................... 573
Butterfly valves................................................................................361
Bypass mixing valves and bypass valves........................................593 H
Bypass mixing valves and bypass valves Accessories and spare H-blocks Accessories and spare parts............................................ 119
parts................................................................................................ 595 Heating load calculation................................................................. 755
Heating oil filters/Heating oil deaerators Accessories and spare
parts................................................................................................609
C Heating oil kits for export...............................................................638
Check valves...................................................................................442 Hose lines according to DIN EN ISO 6806.....................................634
ClimaCon F Room thermostats for surface heating........ 38, 194, 720 Hycocon Accessories and spare parts............................................272
Cocon Accessories and spare parts............................................... 287 Hycocon ATZ Shutoff valves..........................................................270
Cocon QDP Control valves with differential pressure regulator... 286 Hycocon DTZ Differential pressure regulators..............................268
Cocon QTR Valves DN 40 and DN 50............................................ 283 Hycocon ETZ and HTZ Accessories............................................... 316
Cocon QTZ Valves up to DN 32..................................................... 280 Hycocon ETZ Two-way valves........................................................ 314
Cocon Q Valves with flanges......................................................... 284 Hycocon HTZ Two-way valves with high flow rate........................ 315
Cofit S Compression fittings........................................................... 132 Hycocon Valve inserts.....................................................................271
Cofloor Accessories and spare parts.............................................. 183 Hycocon VTZ Double regulating and commissioning valves........267
Cofloor Base mat system................................................................ 176 Hycoflow VTB Balancing valves..................................................... 276
Cofloor Drywall construction system............................................. 181 HydroCom A Shutoff valves...........................................................266
Cofloor Tacker system.................................................................... 174 HydroCom V Double regulating and commissioning valves.........265
Cofloor Velcro system.....................................................................179 HydroControl Accessories and spare parts....................................256
Combi 2 Radiator lockshield valves..................................................98 HydroControl A Shutoff valves...................................................... 242
Combi 3 Radiator lockshield valves................................................100 HydroControl D Differential pressure regultators.........................240
Combi 4 Radiator lockshield valves................................................ 101 HydroControl Double regulating and commissionig valves with
Combi Accessories and spare parts............................................... 106 measuring orifice.............................................................................251
Combi C Radiator lockshield valves............................................... 104 HydroControl Double regulating and commissioning valves....... 243
Combi E Radiator lockshield valves................................................ 103 HydroControl Double regulating and commissioning valves for
Combi LR Radiator lockshield valves..............................................105 shipbuilding.................................................................................... 249
Compression fitting - for products with internal thread................ 376 HydroControl Double regulating and commissioning valves for so-
Connecting blocks..........................................................................200 lar.....................................................................................................253
Connection of the boiler and storage cylinder to the pipework....437
766
7.2
GENERAL INFORMATION
INDEX
Page Page
HydroControl M Double regulating and commissioning valves with Optibal TW Accessories and spare parts........................................571
measuring orifice............................................................................ 239 Optibal TW Ball valves for potable water.......................................569
HydroControl Shutoff valves..........................................................254 Optibal W6 Accessories and spare parts....................................... 302
HydroControl V Double regulating and commissoning valves..... 238 Optibal W6 Six-way ball valves....................................................... 301
Hydrocor HP/HS Accessories and spare parts...............................510 Optiflex Fill and drain ball valves....................................................345
Hydrocor HP Buffer storage cylinders........................................... 508 Other ball valves.............................................................................340
Hydrocor HS Solar buffer storage cylinders...................................509 Other fill and drain cocks............................................................... 348
Hydrocor WB Bivalent potable water storage cylinder.................. 512 OV-Connect Differential pressure sensor.......................................321
Hydrocor WM Monovalent potable water storage cylinders..........511 OV-DMC 3 Measuring device..........................................................320
HydroFixx Hydraulic separator / distributor combination.............419 OV-Flex ST Accessories and spare parts........................................669
Hydromat Accessories and spare parts......................................... 262 OV-Flex ST Pipes............................................................................ 668
Hydromat Differential pressure regulators....................................260
Hygate Gate valves......................................................................... 352
Hygate Gate valves with flanges.................................................... 353 P
pinox Thermostats........................................................................... 28
Pipeline valves................................................................................ 627
I Piston type spring assisted check valves.......................................364
Individual parts............................................................................... 382 Pressure gauge cocks..................................................................... 356
Inversion fittings..............................................................................118 Pressure gauge shutoff valves........................................................357
i-Tronic Climate meter...................................................................... 49 Products for vacuum tank monitoring........................................... 618
M Q
Manual regulating heads.................................................................. 33 Q-Tech Accessories and spare parts................................................ 73
Manual regulating valves.................................................................. 91
Measuring orifices...........................................................................325
mote 200 Electronic wireless thermostat (Bluetooth).....................32 R
Mounting and conversion aids........................................................129 R-Con Accessories.......................................................................... 210
MSM-Block Boiler safety devices...................................................440 R-Con Wireless receivers............................................................... 208
Multiblock T Connection fittings with thermostatic valve.............114 Regtronic Accessories.................................................................... 744
Multiblock TQ Connection fittings with thermostatic valve........... 70 Regtronic Accessories and spare parts.......................................... 661
Multiblock TQ-RTL Connection fitting with thermostatic valve and Regtronic Electronic controllers..................................... 431, 659, 740
return temperature limiter................................................................ 71 Regucirc Accessories and spare parts............................................550
Multiblock T-RTL Connection fittings with thermostatic valve and Regucirc Circulation station........................................................... 549
return temperature limiter.............................................................. 116 Regucor WH/WHS Accessories and spare parts........................... 517
Multidis Accessories and spare parts..............................................161 Regucor WH Energy storage centres............................................. 516
Multidis R Accessories and spare parts..........................................587 Regucor WHS Energy storage centres........................................... 515
Multidis R Sanitary distributors...................................................... 586 Regudis H Accessories and spare parts.........................................450
Multidis SF Heating circuit distributors/collectors for surface heat- Regudis H Transmission stations.................................................. 446
ing and surface cooling................................................................... 156 Regudis W-HTE Accessories and spare parts................................ 475
Multidis SFI Distributors/collectors for industrial surface heating / Regudis W-HTE Electronic dwelling stations.................................473
cooling and concrete core activation............................................. 160 Regudis W-HTF Hydronic dwelling stations.................................. 492
Multidis SFQ Heating circuit distributors/collectors with Q-Tech. 158 Regudis W-HTU/W-HTF Accessories and spare parts.................. 497
Multidis SH Accessories..................................................................126 Regudis W-HTU Hydronic dwelling stations................................. 485
Multidis SH Heating circuit distributors/collectors........................ 125 Regudrain Accessories and spare parts.........................................546
Multiflex F H-blocks......................................................................... 117 Regudrain Flushing stations...........................................................545
Multiflex FQ Connection fittings without thermostatic valve......... 72 Regufloor Accessories and spare parts.......................................... 189
Regufloor Control stations for surface heating..............................187
Regumaq X-25/X-45 Accessories and spare parts........................ 456
O Regumaq X-25 Fresh water stations..............................................454
Ofix Compression fittings............................................................... 133 Regumaq X-30/XZ-30 Accessories and spare parts......................465
Ofix Connection fittings................................................................. 580 Regumaq X-45 Fresh water stations..............................................455
Ofix-Oil Compression fittings........................................................ 629 Regumaq X-80 Accessories and spare parts..................................461
Ofix-Oil Cutting ring compression fittings.....................................630 Regumaq X-80 Fresh water stations............................................. 460
Ofix-Oil Double nipples.................................................................. 633 Regumaq XH Accessories and spare parts....................................469
Oilpur Heating oil filters................................................................. 606 Regumat Distributors..................................................................... 415
Oilstop Anti-siphon valves............................................................. 626 Regumat F Accessories and spare parts........................................407
OKF Accessories and spare parts...................................................679 Regumat F Stations for fixed value control................................... 404
OKF-CK22 Flat-plate collectors...................................................... 676 Regumat Heat exchanger.............................................................. 424
OKF-CS22 Flat-plate collectors.......................................................677 Regumat High-efficiency pumps................................................... 429
OKF-MQ25 Flat-plate collectors..................................................... 678 Regumat M3 Stations for variable temperature heating circuits...393
OKP Accessories and spare parts...................................................672 Regumat RTA Accessories and spare parts....................................413
OKP Tube collectors........................................................................671 Regumat RTA Stations for return temperature increase............... 410
One pipe valves Accessories and spare parts................................ 148 Regumat S/M3 Accessories and spare parts................................. 398
One pipe valves with shutoff..........................................................142 Regumat S Stations for constant temperature heating circuits.... 388
Optibal Accessories........................................................................ 341 Regumat Tailpipe sets.................................................................... 426
Optibal Ball valves with lever..........................................................333 Regumat Thermal insulations........................................................428
Optibal Ball valves with plastic handle...........................................330 Regusol Accessories and spare parts............................................. 651
Optibal Ball valves with T-handle................................................... 334 Regusol ELH Stations with electronic controller and vent pot......647
Optibal High pressure ball valves PN 40........................................337 Regusol LH Stations with vent pot................................................ 645
Optibal High temperature ball valves.............................................336 Regusol PH Pump circuits..............................................................642
Optibal P Pump ball valves............................................................. 335 Regusol SH Stations....................................................................... 643
767
7.2
GENERAL INFORMATION
INDEX
Page Page
Regusol X Stations with heat exchanger....................................... 649 Valves for return temperature limitation....................................... 226
Rental devices................................................................................. 757 vindo Thermostats........................................................................... 29
Replacement valve insert................................................................. 96
Return temperature limiters Accessories...................................... 228
Return temperature limiter sets..................................................... 227 W
RFV 9 Thermostatic valves...............................................................80 wibutler Smart Home system........................................................ 708
Room thermostats Accessories....................................... 44, 199, 726
Room thermostats heating.............................................. 40, 196, 722
Room thermostats heating/cooling.................................42, 198, 724
Room thermostats heating/cooling with fan control..............43, 725
R-Tronic Accessories........................................................ 48, 207, 729
R-Tronic system for individual room temperature control............. 713
R-Tronic Wireless thermostats.........................................46, 205, 728
S
Service.............................................................................................758
Sets with pinox thermostat...............................................................61
Sets with Uni LH thermostat............................................................ 58
Sets with Uni SH thermostat............................................................ 59
Sets with vindo TH thermostat........................................................ 62
Shutoff valves................................................................................. 354
Smart Building system solutions Accessories and spare parts..... 705
Smart Home system solutions Accessories................................... 716
Solar Diaphragm expansion tanks................................................. 664
Solar Diaphragm expansion tanks Accessories and spare parts...666
Solar In-line tanks........................................................................... 665
Solcos Solar packages with flat-plate collectors............................685
Solcos Solar packages with tube collectors...................................684
Spare parts for butterfly valves...................................................... 363
Spare parts for strainers................................................................. 370
Strainer............................................................................................367
Swing check valves......................................................................... 365
T
Tailpipe sets for external thread, for products with union nuts and
sealing rings....................................................................................380
Tank extraction............................................................................... 622
Tank filling limiter Accessories and spare parts............................. 617
Tank filling limiters.......................................................................... 616
Temperature controllers..................................................................311
Thermal circulation valves Accessories and spare parts............... 535
Thermostatic valves Accessories and spare parts........................... 93
Thermostats Accessories and spare parts.......................................34
Three-way conversion valves......................................................... 145
Toc Heating oil filter / deaerator combinations and heating oil dea-
erators............................................................................................ 604
Tri-CTR Three-way diverting and mixing valves............................ 310
Two-/three-way valves with flanges.............................................. 312
Two pipe valves with shutoff..........................................................150
U
Unibox Accessories and spare parts...............................................215
Unibox Return temperature control............................................... 212
Unibox Room temperature control and return temperature control
......................................................................................................... 213
Uni CH Thermostats.........................................................................30
Unidis Accessories and spare parts................................................223
Unidis Connection without distributor/collector for surface heating
........................................................................................................ 220
Uni F Thermostats.............................................................................31
Uni L Special thermostats.................................................................22
Uni L Thermostats............................................................................ 20
Uni SH Thermostats......................................................................... 27
Uni X Thermostats............................................................................25
Unofix Refurbishment of one pipe heating systems......................139
V
Valve inserts Accessories and spare parts...................................... 112
Valve inserts for radiators with integrated valve set...................... 110
768
7.2
GENERAL INFORMATION
INDEX
769
7.2
GENERAL INFORMATION
INDEX
770
7.2
GENERAL INFORMATION
INDEX
771
7.2
GENERAL INFORMATION
INDEX
772
7.2
GENERAL INFORMATION
INDEX
773
7.2
GENERAL INFORMATION
INDEX
774
7.2
GENERAL INFORMATION
INDEX
775
7.2
GENERAL INFORMATION
INDEX
776
7.2
GENERAL INFORMATION
INDEX
777
7.2
GENERAL INFORMATION
INDEX
778
7.2
GENERAL INFORMATION
INDEX
779
7.2
GENERAL INFORMATION
INDEX
780
7.2
GENERAL INFORMATION
INDEX
781
7.2
GENERAL INFORMATION
INDEX
782
7.2
GENERAL INFORMATION
INDEX
783
7.2
GENERAL INFORMATION
INDEX
784
7.2
GENERAL INFORMATION
INDEX
785
7.2
GENERAL INFORMATION
INDEX
786
7.2
GENERAL INFORMATION
INDEX
787
7.2
GENERAL INFORMATION
INDEX
788
7.2
GENERAL INFORMATION
INDEX
789
7.2
GENERAL INFORMATION
INDEX
790
7.2
GENERAL INFORMATION
INDEX
791
7.2
GENERAL INFORMATION
INDEX
792
7.2
GENERAL INFORMATION
INDEX
793
7.2
GENERAL INFORMATION
INDEX
794
7.2
GENERAL INFORMATION
INDEX
795
7.2
GENERAL INFORMATION
INDEX
796
7.2
GENERAL INFORMATION
INDEX
797
7.2
GENERAL INFORMATION
INDEX
798
7.2
GENERAL INFORMATION
INDEX
799
7.2
Room climate Hydronics
Oventrop is the partner for efficient heating, cooling and clean potable water.
The modular systems and services offer pioneering solutions which all HVAC experts
use to work with – easily and flexibly – from planning to installation, from industry to
trade. As a family business, Oventrop accompanies all its partners over many years –
competently and personally.