Steel Notes: Typical Detail of Stiffener Column & Beam For Masonry

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

REPUBLIC OF THE PHILIPPINES

DPWH
OFFICE OF THE BUILDING OFFICIAL

RECOMMENDING ISSUANCE:

HEAD STRUCTURAL SECTION DATE


ISSUED BY:

BUILDING OFFICIAL DATE

STEEL NOTES

if more than 3000 mm. span provide stiffener column


3000 3000 3000
THICKNESS OF WALL
2 - 16 mm Ø MAIN
BARS

3000 PSI

250
10 mm Ø STIRRUP
SPACE @ 300

STIFFENER COLUMN PLAN VIEW

MAIN BEAM N.T.S.


if more than 3000 mm. height

STIFFENER COLUMN @

STIFFENER COLUMN @
3000
provide stiffener beam

EVERY 3000 mm ±

EVERY 3000 mm ±
CHB CHB CHB
MAIN COLUMN

MAIN COLUMN
STIFFENER BEAM @ EVERY 3000 mm HEIGHT± STIFFENER BEAM @ EVERY 3000 mm HEIGHT± STIFFENER BEAM @ EVERY 3000 mm HEIGHT±

THICKNESS OF WALL

STIFFENER COLUMN @

STIFFENER COLUMN @
3000

2 - 16 mm Ø MAIN

EVERY 3000 mm ±

EVERY 3000 mm ±
BARS
CHB CHB CHB 3000 PSI

250
10 mm Ø STIRRUP
SPACE @ 300

STIFFENER BEAM SECTION VIEW


N.T.S.

MAIN BEAM

TYPICAL DETAIL OF STIFFENER


COLUMN & BEAM FOR MASONRY
N.T.S.

DESIGNED BY: THIS DRAWING IS ISSUED FOR :


R.A.9266 Section 33
SEAL PROJECT TITLE SHEET CONTENT SHEET NO.
DRAFTED BY: AS BUILT ESTIMATE
Drawing and specifications and other
AS SHOWN MAV
contract documents signed, stamped or sealed, as BIDDING FABRICATION
instruments of service, are the intellectual property
CIVIL / STRUCTURAL DESIGN ENGINEER BUILDING PERMIT OWNER'S APPROVAL

REG. NO.: DATE :


and documents of the architect, whether the object
for which they are made is executed or not, if shall
be unlawful for any person to duplicate or to make
copies of said documents for use in the repetition
CONSTRUCTION PRESENTATION
S1
PTR NO. : DATE : of and for other projects of building, whether
executed partly in whole, without the written
TIN : consent of architect or author of said documents.