AAD03061D Door Controller Quick Guide
AAD03061D Door Controller Quick Guide
AAD03061D Door Controller Quick Guide
Quick Guide
AAD03040 Door controller quick guide
1. Wiring
Before using this product, please confirm that the wiring for the power and motor and
the control terminals connected correctly.
Wiring diagram:
DOOR CONTROLLER
AAD03061D
CLOSE Signal
Power IN: OPEN Signal
1-Phase
220V AC COM
RY output COM
CLOSE arrival output signal
* Set the parameter P033/P034 to select the RY1/RY2 output function, and select the
NO/NC mode
P033=r10: RY1 Terminal A1\C1 NC Mode,P033=10: RY1 Terminal A1\C1 NO Mode;
P034=r11: RY2 Terminal A2\C2 NC Mode,P034=11: RY2 Terminal A2\C2 NO Mode;
-2-
AAD03040 Door controller quick guide
Basic
STEP 1
operation:
STEP 2
Power on,
STEP1 Select
STEP 3
the (PMSM)
motor type
Set the
STEP 4
parameter H001=2
(50W Motor)
(The parameter
STEP 5 H002~005,H0
10~016 will be
STEP 6 set
automatically,
please don't
STEP 7 change the
setting data value.)
parameter
Setting the motor direction of rotation (Parameter H007)
-3-
AAD03040 Door controller quick guide
When open the door, the motor rotates clockwise: Set H007=0
When open the door, the motor counter-clockwise rotation: Set H007=1
Setting synchronous starting-up parameter
Adjust the parameter H022(synchronous starting-up torque level)according
to the load.
Set the parameter H023=1
(H023=1,After synchronous starting-up,the controller will run according to
the OPEN/CLOSE command signal)
Power OFF, and connect the load to the motor.
* If the door can not be operated because the low torque level,
Please increase the setting value of the parameter H022.
Door width measurement mode, the door will operate according to the following step:
Current position →OPEN Arrival position →CLOSE Arrival position →OPEN Arrival position
-4-
AAD03040 Door controller quick guide
If there is no arrival area width, the door position data will not conform to arrival area
in normal operation. To secure the arrival area, the setting of OPEN/CLOSE arrival
position shall be changed.
b. Set the parameter P003=1
Press the ▲+RUN button(OPEN Operation) or ▼+RUN button(CLOSE Operation),
to check the OPEN/CLOSE operation。
-5-
AAD03040 Door controller quick guide
Door Region 0 1 2 3 4 7
d002 d003 d004 d005 d006
Open
Signal ON
Close
Signal ON
Open
Arrival Signal ON
Close
Arrival Signal ON
100%
Door
Position
0%
-6-
AAD03040 Door controller quick guide
CLOSE Operation
100%
Door
Position
0%
-7-
AAD03040 Door controller quick guide
(Door control normal mode is operated after the door width setting value of
parameter d001 is set correctly.)
-8-
AAD03040 Door controller quick guide
* Calculates the detection frequency with the encoder signal to get the frequency ration.
When the frequency ration is less than the setting value of the d050 and d051, overload
(sandwich of automatic door occurs) is judged.
* Frequency ratio can change between high speed and low speed
Changing frequency can be set with parameter d052.
-9-