Derate Tables: 2800 Series 2806C-E18

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Derate Tables

2800 Series 2806C-E18


Diesel Engines TAG1A, TAG3
emissions compliant
2806C-E18 TAG1A @ 1500 rev/min
Derate for high intake temperature and/or elevated altitude from ISO 3046 standard conditions.

Derate Chart 2806-E18 650 kVA Low E


45%

40%

35%

30%
Derate (%)

25%

20%

15%

10%

5%

0%
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Atitude (MASL)

Derate 25C Derate 30C Derate 37C Derate 43C Derate 50C

Note: Ambient temperature at air cleaner inlet.


2800 Series 2806C-E18

2806C-E18 TAG3 @ 1800 rev/min


Derate for high intake temperature and/or elevated altitude from ISO 3046 standard conditions.

Derate Chart 2806-E18 600 EKw Low E


40%

35%

30%

25%
Derate (%)

20%

15%

10%

5%

0%
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Atitude (MASL)

Derate 25C Derate 30C Derate 37C Derate 43C Derate 50C

Note: Ambient temperature at air cleaner inlet.

Publication No. TPD1707E, issue 1. Printed in England. ©Perkins Engines Company Limited

Distributed by

Perkins Engines Company Limited


Peterborough PE1 5NA United Kingdom
Telephone +44 (0) 1733 583000
Fax +44 (0) 1733 582240
www.perkins.com

All information in the document is substantially correct at the time


of printing but may be subsequently altered by the company.