ROOM FUNCTION LIVE LOAD (25% REDUCIBLE) LIVE LOAD (50% REDUCIBLE) FLOOR FINISH NOTES (FLOOR FINISH)
BALCONY 4 1.2
BAR 3 2.2 1.0 EXTRA FOR BAR PROPS
BASEMENT PARKING 10 3.2 DOUBLE LAYER PARKING DOUBLED + JACKING PROP 1.5 KN/M2 ADDED+0.5 kn/m2 false ceiling
CHANGING ROOMS 2.5 1.7
FRONT GF LOAD 4 4.5 1 FLOOR FINISH +3 DEAD LOAD
GARDEN 3 5.2 1.2KN/M2+4KN/M2 FOR SOIL
GYM AND SAUNA 3 6.7 1.2KN/M2+5KN/M2 FOR EQIPMENTS
HALL 5 1.7
KITCHEN 3 2.2 1.2KN/M2+1.2KN/M2 FOR EQUIPS
LIFT MACHINE ROOM 1.5 10 10KN/M2 FOR MACHINE ROOM DEAD LOAD
LOBBY SPACE/PASSAGE 4 1.7
OFFICEROOMS 2.5 1.7
PANTRY /CAFETERIAS 4 2.2 1.2KN/M2+1.0KN/M2 FOR EQUIPS
RAMP 7 1
ROOMS 2 1.7
STORE ROOMS 5 1.7
STORE WITHOUT FC 5 1.2
SWIMMING POOL 4 21.7 1.2KN/M2 FF+1.0KN/M2 FOR EQUIPS AND WATER
TERRACE ACCESSIBLE 1.5 1.2 1.2KN/M2 FF+ DIFFERENT FOR TANKS AS PER DEAD LOAD CALCULATIONS
TOILETS 2 1.7
FALSE CEILING LOAD 0.49 KN/M2
ITEM DENSITY THICKNESSLOAD REQUIRED LOAD APPLIED
SCREEDING 20 0.05 1 1 KN/M2
TILE clay floor tiles as per is- 1478 1969 0.2 KN/M2