Liebert NXR Series: 15kva To 90kva (208V/220V)
Liebert NXR Series: 15kva To 90kva (208V/220V)
Liebert NXR Series: 15kva To 90kva (208V/220V)
Business-Critical Continuity™
Today, you need a power infrastructure How the Liebert NXr Enables Adaptive
that can work across your enterprise
and respond to constant change: an Architecture?
infrastructure that allows you to deploy Lowest Cost of Ownership
blade servers and other high-density Liebert NXr was designed to minimize capital equipment expenses and
equipment safely and cost-effectively. You optimum efficiency. Its low footprint saves costly floor space while effectively
need an infrastructure that can meet the managing data center facilities with high densities. It provides 100% usable
strict power quality requirements of real power with high generator compatibility because of low input THDi, high
VoIP switches. input power factor, low input cable and switch gear rating.
An infrastructure that allows you to add Enhanced Operational Flexibility
capacity without compromising availability In response to the demands of new technologies, the Liebert NXr achieves
or serviceability. higher tiers of availability and support even with increased densities with
Scalability alone can’t get you there. You minimal disruption to operations. It has configurable battery and standard
need an infrastructure that takes it one top cable entry. Liebert NXr allows easy configuration of different system
step further. An infrastructure that can architectures like dual bus and parallel ability.
adapt to your needs.
Higher System Availability
Liebert NXr provides a mission-critical technology that minimizes single points
of failure in your network. A UPS that promises the highest possible availability
of your IT systems; the Liebert NXr highlights reliability with low mean time
to repair (MTTR).
Extreme Performance
Up to 94% efficiency
Greater than 99% Input Power Factor
Less than 3% input THDi
Space Savings
90KVA UPS at 208v with a floorprint of 0,51m2.
2
Liebert NXr
Efficient and Adaptive Power
For Your Critical Applications
The Liebert NXr from Emerson Network Power presents an efficient, space saving and flexible solution for your network. With
an above industry standard efficiency rate of up to 94% in a compact, low footprint UPS, Liebert NXr keeps your network
protected while saving on cost and data center space.
With best in class true online double conversion technology, redundancy options and flexible battery configurations, trust the
Liebert NXr to provide the same level of reliability you have come to expect from the Liebert NX UPS series.
Efficiency Savings
Ratings (kVA) Traditional UPS (92%) Liebert NXr (94%) Annual Saving Saving @10 Years
3
The best investment you can make in a UPS system:
Efficiency, Reliability and Value in a compact package.
How can I get the most out of my investment? Liebert NXr has built in Parallel and Load Bus Synchronization
Liebert NXr, with its unity power factor (kVA=kW), (LBS) boards. No extra hardware is needed; it may be easily
offers more real power to support customer’s mission connected just with control cables.
critical loads.
How can I save floor space with Liebert NXr?
With up to 94% online double conversion efficiency, Liebert
Liebert NXr is a compact UPS with low footprint.
NXr saves you operating costs compared to most traditional
UPS’s in the market. A 90kVA a 208V Liebert NXr UPS can be installed in less than
0.51m2 space.
How can I get optimum protection for my network
with Liebert NXr? How can I satisfy the requirements of the latest servers?
The double conversion technology of Liebert NXr allows it Liebert NXr is capable of driving wide ranges of loads, from
to have an above average industry standard of up to 94% 0.5 lagging to 0.9 leading. This makes the UPS follow the
efficiency , giving your network and data center equipment latest IT industry trends, with more active power available
full protection at the most efficient rate. for all kinds of loads.
How can I get the highest levels of Protection and Availability? How can I also protect also my upstream-connected devices?
Liebert NXr gives you built-in reliability with its stratified The Liebert NXr provides the cleanest level of upstream
cooling technology allowing cooling of critical components power with the lowest level of input current THDi in
and a redundant cooling fan option. the industry.
Wider input voltage and frequency tolerances contribute to This ensures that clean power flows upstream, avoiding
high power availability. damage to other loads connected to the upstream power
Digital controls provide the fastest possible power distribution bus.
management to enhance reliability, accuracy and efficiency How can I extend the system when I need more power?
while reducing component count.
Liebert NXr features easy and simple scalability and
Dual bus compatibility and system redundancy further
redundancy. In fact, up to four Liebert NXr modules may be
enhance the availability of a power. paralleled in a redundant configuration for added reliability
High overload protection handles 110% overload for 60 and serviceability.
minutes, 125% for 10 minutes, and 150% for 1 minute. The Liebert NXr is compatible with Liebert‘s unique LBS.
How can I save on my electricity bill and investment costs?
The improved input power factor of the Liebert NXr can
actually reduce your electricity usage.
It delivers the highest possible input power factor - greater
than 0.99 at rated linear and non-linear loads - for
maximum efficiency.
The unique ability of the Liebert NXr to adjust power walk-in
from 5 seconds to 30 seconds, along with reduced input
current distortion and power factor correction, also
enables you to save money by reducing back-up generator
sizing requirement.
The unit’s compact footprint requires less floor space,
leaving you with more room for other equipment.
4
How can I ensure the UPS will work under the most severe conditions? Configurations:
The wide input voltage window of 165-253V and a frequency tolerance of A Full Range of Features
40Hz to 70Hz provide high quality power, even when input parameters are To meet all your power availability needs
below standard. This helps minimize transfers to the battery, reducing the for single or dual input operation, your
charging and discharging cycles. Liebert NXr power system can be utilized
Back-feed protection sensing ensures system integrity. with either single or dual power inputs.
Short-circuit-proof, DSP controlled inverter provides highest output The dual power feature allows you to take
power quality. advantage of a secondary power source.
Liebert NXr
To meet a variety of needs, the Liebert NXr offers communications
through web or management systems through MODbus and SNMP
communication protocol.
The Liebert NXr features easy access for service. Thanks to front accessibility of
critical components, self-diagnostics and various monitoring options. 1+N Configuration
Liebert NXr
Liebert NXr
Liebert NXr
Liebert NXr
different languages.
Liebert NXr
Liebert NXr
Liebert NXr
Liebert NXr
Liebert NXr
Liebert NXr
Liebert NXr
power monitoring communications alternatives and user friendly control are
all handled through the menu-driven LCD control panel with detailed
data reporting.
Emerson Network Power is recognized to be a great solution provider. Please
contact your local Emerson Network Power office or Liebert representative to Paralleling Dual Bus
Signal Cable Signal Cable
receive special solution consultancy.
Liebert STS
How can I protect and extend the life of my batteries?
Critical Load#1
Liebert NXr minimizes transfers to batteries with its wide input voltage
Liebert STS
tolerance down to 165V.
Temperature-compensated battery charging extends battery life. Critical Load#2
5
Addressing a Variety of Needs
Today’s advanced systems require power protection that is just as innovative. Information Technology
These systems, however, face many of the traditional threats to their Data Centers.
availability - foremost among them is a lack of high quality power required to
operate sensitive electronics. Servers (LAN, WAN, MAN, ERP, e-mail,
web and others).
The goal of Emerson Network Power is solving these challenges with a power Networking
solution that combines high performance, operating efficiency, compact size,
reliability and total cost of ownership. Telecommunication
Mobile (2G, 2.5G, 3G).
Emerson Network Power Liebert NXr is the Next Generation of true-online,
double conversion digital UPS. Designed to meet the high availability power Paging.
needs of a wide variety of applications (IT, non-IT, industrial & medical), Fixed (including WLL)
the Liebert NXr combines innovation and simplicity and low total cost of
ownership. The result is a power system that delivers both reliability and a Industrial Automation
return on investment beyond what has been traditionally offered. Process (including instrumentation)
Advanced Monitoring and Motion (digital drives and robotics)
Communications Capabilities Keep You in Control Transport Automation
Power Communication Options Airport automation and flight booking
Others including railways and road
When choosing the best system to protect your mission critical applications,
an important consideration would be the software and communication transport automation and ticket
options. As part of our commitment to provide the best solution for you, booking
we offer a wide range of sophisticated software and communication options
Banking, Insurance and Financial
for Liebert NXr.
Services
The most extensive list of optional communication solutions Software Development Houses /
for Liebert NXr UPS Systems Software Technology Parks (STP)
Control through Building Management Systems via Modbus and Jbus Building Automation
protocols Access Control.
Security System.
Web-enabled Monitoring and Management through SNMP protocols.
Network Management Systems ready. Fire Alarm System.
6
Technical Specifications
Model NXr
Power 15 kVA1 30KVA 45KVA 60KVA 75KVA 90KVA
1 30KW 45KW 60KW 75KW 90KW
15KW
System efficiency
AC-AC online double conversion up to 94%
Input Parameters
Rated input voltage 208/220VAC, three-phase four-wire
Rated operating frequency 50/60 Hz
Input voltage range 166V -253V at full load-25% to -40% with linear load derating
Input frequency range 40Hz - 70Hz
Input power factor >0.99 at full load, >0.98 at half load
Input THDI <3%
Input walk-in function Available, 5 - 30s (settable)
DC Parameter
Battery Type VRLA
Battery Compensation Yes
Charger output voltage regulation accuracy 1%
DC ripple low voltage ≤1%
Output Parameter
Inverter output voltage 208/220VAC, three-phase four-wire
Inverter output frequency 50/60 Hz
Output frequency stability 50Hz/60Hz±+/- 0.1%
Load power factor handling capability
0.9 leading - 0.9 lagging
(without capacity derating)
Voltage stability
Steady state < ±1%, typical
Transient state ±5%, typical
Transient state response time <16,6ms
Inverter overload capacity 1 hour for 110%, 10mins for 125%, 1min for 150%, 200ms for >150%
Phase Shift
With 100% balanced load <1° el
With 100% unbalanced load <1° el
THDv
100% linear load <1%
100% non-linear load <4%
Bypass Parameter
Bypass input voltage 208/220 VAC, three-phase four-wire
Bypass voltage range Default: -20% to +15%, other values, such as -40%, -30%, -10% to +10%, +15% settable
through software
Bypass overload capacity 110% long term 170% 10 minutes 1000% for 100ms
Environmental Conditions
Operating temperature range 0 - 40°C
Storage temperature -25 - 70°C
Maximum operating altitude ≤1000m, When operating at 1000>2000m, derated by 1% for every 100m increase of
altitude
Relative Humidity ≤95%
Noise (1m) 56-66dB, adjusted according to load rate
IP Class IP20
Standards Safety: IEC60950-1; IEC62040-1-1/AS62040-1-1
EMC: IEC62v040-2/AS62040-2/EN50091-2 CLASS A
Design and test: IEC62040-3/AS62040-3
Physical Parameters
Dimension, w x h x d (mm) 600 x 1400 x 843 600 x 1600
x 843
Weight (kg) 200 234 268 302 336 380
1. with internal battery compartment
Emerson Network Power, a business of Emerson (NYSE:EMR), delivers software, hardware and Emerson Network Power
Liebert Corporation World Headquarters
services that maximize availability, capacity and efficiency for data centers, healthcare and 1050 Dearborn Drive
P.O. Box 29186
industrial facilities. A trusted industry leader in smart infrastructure technologies, Emerson Columbus, Ohio 43229
United States Of America
Network Power provides innovative data center infrastructure management solutions that 800 877 9222 Phone (U.S. & Canada Only)
614 888 0246 Phone (Outside U.S.)
bridge the gap between IT and facility management and deliver efficiency and uncompromised 614 841 6022 FAX
[email protected]
availability regardless of capacity demands. Our solutions are supported globally by local
Emerson Network Power
Emerson Network Power service technicians. Learn more about Emerson Network Power Caribbean and Latin America
Office – United States of America
products and services at www.EmersonNetworkPower.com +1-954-984-3452 Phone
[email protected]
Emerson Network Power
European Headquarters
Office – Italy
+39 049 9719 111 Phone
+39 049 5841 257 FAX
[email protected]
Emerson Network Power
Asia Pacific
Office – Phillipines
+63 2 687 6615
+63 2 730 9572 FAX
[email protected]
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)
While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.
©2012 Emerson Electric Co.