SF - ELE - Lago de Guadalupe - Arrancador VE

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Manual Starters and Switches

Selection Guide

Catalog
2510CT9701R01/16
2016
Class 2510, 2511, 2512, 2601

CONTENTS
Fractional Horsepower Manual Starters—Type F . . . . . . . . . . . . . . . Page 3
Manual Switches—Type K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6
Integral Horsepower Starters—Types M and T . . . . . . . . . . . . . . . . Page 13
Accessories, Modifications, and Renewal Parts. . . . . . . . . . . . . . . . Page 17
Reversing Drum Switches—Class 2601 . . . . . . . . . . . . . . . . . . . . . Page 18
Manual Starters and Switches
Fractional Horsepower Manual Starters with Melting Alloy Thermal Overload Relay—Type F

Fractional Horsepower Manual Starters with Melting Alloy


Thermal Overload Relay—Type F

Application Data

Type F fractional horsepower starters provide overload protection as well as manual On-Off control for
small motors in a variety of industrial and commercial installations. Typical applications include fans,
conveyors, pumps, and small machine tools.
Both one-pole and two-pole versions are suitable for use with AC single-phase motors rated up to
1 hp. Two-pole starters can also be used with DC motors rated up to 0.75 hp.
Type FG2P Table 1: Electrical Ratings
277 Vac maximum (1 or 2 pole)
Voltage Rating 230 Vdc maximum (2 pole only)
Continuous Current Rating 16 A

Table 2: Horsepower Ratings


Maximum Horsepower
Volts AC Single Phase DC
1 Pole 2 Pole 2 Pole Only
115 1 1 0.75
230 1 2 0.75
277 1 1 —

Enclosures: NEMA 1 surface mounting enclosures are sheet steel with a thermoplastic wrap-around
cover for convenience in wiring. The NEMA 1 enclosure is also available in an oversized version that
allows more space for wiring. A zinc alloy die casting is used for NEMA 4 enclosures, and a cast
aluminum enclosure is offered for NEMA 3R, 7 & 9 applications.
Pilot Light: Red or green pilot light units are available factory installed in NEMA 1 surface- and flush-
mounting enclosures and in NEMA 4 enclosures. They are also available as a field modification kit for
NEMA 1 enclosures and gray flush plates.

Type FO2 For a red pilot light, use the order number as is. For a green pilot light, add a G to the number.
Handle Guard/Lock-Off: An optional handle guard on NEMA 1 enclosed starters prevents accidental
operation of the toggle operator and allows the toggle operator to be padlocked in either the On or Off
position.
The handle guard can be factory installed on NEMA 1 enclosed starters. It is also available in kit form
for field installation on NEMA 1 surface- and flush-mounting enclosures. Standard NEMA 4 and
NEMA 3R, 7 & 9 enclosures include provision for locking in the Off position.
Terminals: Binder head screw-type terminals are suitable for 10 AWG or smaller copper wire, and are
accessible from the front. All terminals are clearly marked.
Mounting: Open types without a pilot light fit standard single-gang switch boxes, and can be used with
any cover plate having a standard toggle cutout. Single-unit flush mounting types, including those with
a pilot light, are suitable for wall mounting in a standard switch box or for machine cavity mounting
without a box.
Operator: Available with toggle handle or with removable key-type operator to discourage
unauthorized operation.
Thermal Units: Starters will not operate without a properly installed thermal unit. Install the thermal
unit so that the markings face the front of the starter.
Emergency Off Actuator: A toggle operator extender is available for NEMA 1 surface-mounted units.
The extender has a red vinyl button that provides a fast and easy method for locating and switching the
device’s toggle operator into the Off position. The Emergency Off Actuator is available in kit form only
for field installation.

3
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Fractional Horsepower Manual Starters with Melting Alloy Thermal Overload Relay—Type F

Table 3: Approvals
Enclosed Unit Open Unit Explosion-Proof Unit

File E42243 File E58760



CCN NLRV CCN NPXZ

File LR25490 File LR25490 File LR26817


Class 3211 05 Class 3211 05 Class 3218 04

File E42243
— —
CCN NLRV2

Figure 1: Typical Wiring Diagrams


2-Pole with
1-Pole 2-Pole NOTE: The lamp is
Selector Switch polarity sensitive
T2 T2 T2 in DC applications.
L2 L2 A O H L2

2 1
L1 L1 A L1
O
Pilot light Pilot light H Pilot light
+ (if used) + (if used) 4 3 + (if used)
R R R
T1 T1 T1
– – –

T1 T2 T1 T2 2 4 4 T2

Motor Motor 2-Wire Control Device Motor


Must be rated for motor current

Table 4: Single-Unit Types (Class 2510)

NEMA 1 General Purpose Flush Mounting NEMA 3R, 7 & 9 [1]


NEMA
General Purpose Enclosure (Without Pull Box) Enclosure Number of
Type 4 [1]
Operator No.of Surface Mounting Class I Groups Open Thermal
Features Flush Plate Watertight
Style Poles B, C, and D Type Units
and Dusttight
Standard Jumbo Class II Groups Required
Standard Oversized Gray Enclosure
Stainless Steel Stainless Steel E, F and G
Basic Starter – Class 2510
Standard FG1 FGJ1 FF1 FS1 — — — FO1 1
1
With Red Pilot Light [2] FG1P FGJ1P FF1P FS1P FSJ1P — — FO1P 1
Toggle
Standard FG2 FGJ2 FF2 FS2 — — — FO2 1
2
With Red Pilot Light [2] FG2P FGJ2P FF2P FS2P FSJ2P — — FO2P 1
Standard FG3 FGJ3 FF3 FS3 — — — FO3 1
1
With Red Pilot Light [2] FG3P FGJ3P FF3P FS3P FSJ3P — — FO3P 1
Key
Standard FG4 FGJ4 FF4 FS4 — — — FO4 1
2
With Red Pilot Light [2] FG4P FGJ4P FF4P FS4P FSJ4P — — FO4P 1
Starter with Handle Guard / Lock-Off – Class 2510
Standard FG5 FGJ5 FW1 FR1 FO1 [3] 1
1
With Red Pilot Light [2] FG5P FGJ5P Order basic starter plus FW1P — FO1P [3] 1
Toggle
Standard FG6 FGJ6 separate handle guard kit. FW2 FR2 FO2 [3] 1
2
With Red Pilot Light [2] FG6P FGJ6P FW2P — FO2P [3] 1
[1] Furnished with one 3/4" pipe tap in the bottom (reversible for top feed). To obtain a 3/4" pipe tap top and bottom, add suffix letter H to the Type number.
[2] For a green pilot light, add the letter G to the catalog number(for example, 2510FGJ2PG).
[3] When replacing a starter equipped with a pilot light in a NEMA 4 enclosure, retain the pilot light mounting bracket from the original device.

4
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Fractional Horsepower Manual Starters with Melting Alloy Thermal Overload Relay—Type F

Table 5: Duplex Units (Class 2510)


General Purpose Flush Mounting
NEMA 1 (Without Pull Box) Number of
Operator No. of General Purpose
Features Thermal Units
Style Poles Enclosure Flush Plate for Wall or Cavity Mounting
Required
Surface Mounting
Gray Stainless Steel
One Starter in Duplex Enclosure—Class 2510
Standard FG02 — — 1
Toggle 2
With Red Pilot Light [1] FG02P — — 1
Key 2 With Red Pilot Light [1] FG04P — — 1
Two Starters in One Enclosure—Class 2510
Standard FG22 FF22 — 2
Toggle 2 per Starter
With Red Pilot Light on Each [1] FG22P FF22P FS22P 2
Key 2 per Starter With Red Pilot Light on Each [1] FG44P FF44P FS44P 2
Starter and Auto-Off-Hand SPDT Selector Switch (AC Only)—Class 2510
Standard FG71 FF71 — 1
1
With Red Pilot Light [1] FG71P FF71P FS71P 1
Toggle
Standard FG72 FF72 — 1
2
With Red Pilot Light [1] FG72P FF72P FS72P 1
Key 2 With Red Pilot Light [1] FG74P FF74P FS74P 1
[1] For a green pilot light, add the letter G to the catalog number (for example, 2510FG02PG).

Table 6: Two Speed Starters (Class 2512)


Type F two-speed manual starters are designed for the control of small single-phase AC motors that
have separate windings for high and low speed operation. Two toggle-operated starters are used, with
overload protection included for each motor winding. Surface mounting devices, and those with a gray
flush plate, utilize a mechanical interlock which allows direct control of the motor by means of the
toggle operators.

Two Speed Starters, Class 2512 Replacement Starter, Class 2510


General Purpose Flush Mounting
NEMA 1 (Without Pull Box) General Purpose Number of
Operator No. of General Purpose
Features on the Standard Device Flush Mounting Thermal Units
Style Poles Enclosure, Flush Plate for Wall or Cavity Mounting
(Without Pull Box) Required
Surface Mounting
Gray Stainless Steel
Mechanical interlock FG11 FF11 — FO1T 2

1 Mechanical interlock and two red pilot lights [1] FG11P FF11P — FO1PT 2

High-Off-Low selector switch and two red pilot lights [1] — — FS101P FO1PT 2
Toggle
Mechanical interlock FG22 FF22 — FO2T 2

2 Mechanical interlock and two red pilot lights [1] FG22P FF22P — FO2PT 2

High-Off-Low selector switch and two red pilot lights [1] — — FS202P FO2PT 2

[1] For a green pilot light, add the letter G to the catalog number (for example, 2510FG02PG).

5
© 1997–2016 Schneider Electric 12/2016
All Rights Reserved
Manual Starters and Switches
Manual Switches—Type K Reversing, Non-Reversing, Two Speed

Manual Switches—Type K
Reversing, Non-Reversing, Two Speed

Application Data

Type K motor starting switches provide manual On-Off control of single- or three-phase AC motors,
where overload protection is not required or is provided separately. These devices are suitable for use
with three-phase AC motors rated up to 20 hp. Compact construction and a 600 V rating make these
switches suitable for a wide range of industrial and commercial uses. Typical applications include small
machine tools, pumps, fans, conveyors, and many other types of electrical machinery. They can also
Type KG1A be used on non-motor loads such as resistance heaters.

Table 7: Electrical Ratings


600 Vac maximum
Voltage Rating 230 Vdc maximum
30 A at 600 Vac maximum (20 A at 600 Vac maximum for NEMA 3R and 7 & 9 enclosed)
Continuous Current Rating 30 A at 24 Vdc maximum

Table 8: Horsepower Ratings


Maximum Horsepower DC Rating
Class Type No. of Poles Motor Type
115 V 230V 460 V 575 V 90 V 115 V 230V
KO1, KO3 2 1-Phase 2 2 3 3 1 2 1.5
KO2, KO4 3 3-Phase 2 7.5 10 10 1 2 1.5
2510
KO5 2 1-Phase 2 3 7.5 10 1 2 1.5
KO6 3 3-Phase 2 7.5 15 20 1 2 1.5
2 1-Phase 2 2 3 3 1 2 1.5
2511 All
3 3-Phase 2 7.5 10 10 1 2 1.5
2 1-Phase 2 2 3 3 1 2 1.5
3-Phase
3 Constant or 2 7.5 10 10 1 2 1.5
2512 All Variable Torque
3-Phase
3 Constant 2 7.5 10 10 1 2 1.5
Horsepower

Enclosures: NEMA 1 surface-mounting enclosures are sheet steel with a thermoplastic wrap-around
cover for convenience in wiring. The NEMA 1 enclosure is also available in jumbo and oversized
versions that allow more space for wiring. A zinc alloy die casting is used for NEMA 4 enclosures, and
Type KO2 a cast aluminum enclosure is offered for NEMA 3R and 7 & 9 applications.
Mounting: Open types without a pilot light fit standard single-gang switch boxes, and can be used with
any cover plate having a standard toggle cutout. Single-unit flush-mounting types, including those with
pilot light, are suitable for wall mounting in a standard switch box or for machine cavity mounting
without a box. For difficult wall surfaces, such as concrete block or tile, a jumbo size flush plate is
recommended. See the dimensional drawings for additional details and mounting provisions of
enclosed types.
Pilot Light: Red or green pilot light units are available factory installed in NEMA 1 surface- and flush-
mounting enclosures and in NEMA 4 enclosures. They are also available as a field modification kit for
NEMA 1 enclosures and gray flush plates.
For a red pilot light, use the order number as is. For a green pilot light, add a G to the number.
Operator: Available with a toggle handle or with a removable key-type operator to discourage
unauthorized operation.
Emergency Off Actuator: A toggle operator extender is available for NEMA 1 surface-mounting units.
The extender has a red vinyl button that provides a fast and easy method for locating and switching the
device’s toggle operator into the Off position. The Emergency Off actuator is available in kit form only
for field installation.

6
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Manual Switches—Type K Reversing, Non-Reversing, Two Speed

Table 9: Approvals
Enclosed Unit Open Unit Explosion-Proof Unit

File E42243 File E58760



CCN NLRV CCN NPXZ

File LR25490 File LR25490 File LR26817


Class 3211 05 Class 3211 05 Class 3218 04

File E42243
— —
CCN NLRV2

Figure 2: Typical Wiring Diagrams


T1
2 Pole 3 Pole L1
1 Phase T1
3 Phase T2 NOTE: The lamp is
L1 L2
polarity sensitive
T3 T3 in DC applications.
L3 L3
– Pilot light – Pilot light
R R
+ (if used) + (if used)

T2
T1 T3 T1 T3

MOTOR MOTOR

Table 10: Non-Reversing (Class 2510)


NEMA 1 Enclosure
NEMA 3R, 7 & 9 [1]
General Purpose, General Purpose, Flush Mounting NEMA 4 [1] Enclosure
Operator No. of Surface Mounting (Without Pull Box) Enclosure Class I Open
Features
Style Poles Flush Plate Watertight and Groups B, C and D Type
Dusttight Class II
Standard Oversized Standard Jumbo
Gray Groups E, F, and G
Stainless Steel Stainless Steel
Standard KG1 KGJ1 KF1 KS1 — KW1 KR1 KO1

2 With Pilot Light [2]


115 Vac KG1A KGJ1A KF1A KS1A KSJ1A KW1A — KO1A [3]
230 Vac KG1B KGJ1B KF1B KS1B KSJ1B KW1B — KO1B [3]
Standard KG2 KGJ2 KF2 KS2 — KW2 KR2 KO2

3 With Pilot Light [2]


208–277 Vac KG2B KGJ2B KF2B KS2B KSJ2B KW2B — KO2B [3]
440–600 Vac KG2C KGJ2C KF2C KS2C KSJ2C KW2C — KO2C [3]
Toggle
Standard KG5 KGJ5 — — — KW5 — KO5

2 With Pilot Light [2]


115 Vac KG5A — — — — KW5A — KO5A
230 Vac KG5B — — — — KW5B — KO5B
Standard KG6 KGJ6 — — — KW6 — KO6

3 With Pilot Light [2]


208–277 Vac KG6B — — — — KW6B — KO6B
440–600 Vac KG6C — — — — KW6C — KO6C
Standard KG3 KGJ3 KF3 KS3 — — — KO3

2 With Pilot Light [2]


— —
115 Vac KG3A KGJ3A KF3A KS3A KSJ3A KO3A
— —
230 Vac KG3B KGJ3B KF3B KS3B KSJ3B KO3B
Key
Standard KG4 KGJ4 KF4 KS4 — — — KO4

3 With Pilot Light [2]


208–277 Vac KG4B KGJ4B KF4B KS4B KSJ4B — — KO4B
440–600 Vac KG4C KGJ4C KF4C KS4C KSJ4C — — KO4C
[1] Furnished with one 3/4" pipe tap in the bottom (reversible for top feed). For a 3/4" pipe tap on the top and bottom, add suffix H to the Type number.
[2] For a green pilot light, add the letter G to the catalog number (for example, 2510KG2BG).
[3] Do not use as replacement interiors for NEMA 4 devices. For a replacement unit, order Type KO1 or KO2 and a separate pilot light kit. (Be sure to retain the pilot light mounting bracket from
the original device.)

7
© 1997–2016 Schneider Electric 12/2016
All Rights Reserved
Manual Starters and Switches
Manual Switches—Type K Reversing, Non-Reversing, Two Speed

Table 11: Reversing (Class 2511)


Type K reversing manual switches provide a compact means of starting, stopping, and reversing AC
File E42243 motors where overload protection is not required or is provided separately. They are suitable for use
CCN NLRV2
with three-phase squirrel cage motors and for single-phase motors that can be reversed by reconnecting
motor leads. Two switches are used, one to connect the motor for forward rotation and one for reverse.
File LR25490
Class 3211 05 No. Features NEMA 1 With Flush Plate for Replacement
Operator Suitable
of (Includes General Purpose Enclosure Cavity Mounting Switch
Style Motor Types
Poles Mechanical Interlock) Surface Mounting (Without Pull Box) Class 2510
Standard KG11 KF11 KO1T
Single Phase, 3-Lead With Pilot Light [1]
2
Repulsion-Induction 115 Vac KG11A KF11A KO1AT
230 Vac KG11B KF11B KO1BT
Toggle Standard KG22 KF22 KO2T
Three Phase; also
Single Phase Capacitor, With Pilot Light [1]
3 110–120 Vac KG22A KF22A KO2AT
Split Phase, or
4-Lead Repulsion-Induction 208–220 Vac KG22B KF22B KO2BT
440–600 Vac KG22C KF22C KO2CT
[1] For a green pilot light, add the letter G to the catalog number (for example, 2511KF11AG).

Table 12: Two Speed (Class 2512)


Type K two-speed manual switches can be used with separate winding three-phase or single-phase
AC motors, where overload protection is not required or is provided separately. Two switches provide
On-Off control in each speed.

No. Features NEMA 1 With Flush Plate for Replacement


Operator Suitable
of (Includes General Purpose Enclosure Cavity Mounting Switch
Style Motor Types
Poles Mechanical Interlock) Surface Mounting (Without Pull Box) Class 2510
Standard KG11 KF11 KO1T
Single Phase,
2 Two Winding With 2 Pilot Lights [1]
(3-Lead) 115 Vac KG11A KF11A KO1AT
230 Vac KG11B KF11B KO1BT
Toggle
Standard KG22 KF22 KO2T
Three Phase,
3 Separate Winding With 2 Pilot Lights [1]
(Wye-Connected) 208-240 Vac KG22B KF22B KO2BT
440–600 Vac KG22C KF22C KO2CT
[1] For a green pilot light, add the letter G to the catalog number (for example, 2512KF11AG).

8
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Approximate Dimensions, Types F and K

Approximate Dimensions, Types F and K

Figure 3: Type F Fractional Horsepower, Open Type


Dimensions are typical for key operator devices.

Type FO2 Types FO1, 1P, 2 Mounting Holes for #6-32 Screws (2)
Fractional Hp Starter Pilot Light

1.69

OFF
43
.84
21

2.38
60
3.28
83
4.13
105

2.22
56
1.59
40

Figure 4: Type K Motor Starting Switch, Open Type


Dimensions are typical for key operator devices.

Mounting Holes For #6-32 Screws (2)


Pilot Light

1.69

OFF
43
.84
21
2.38
3.28 60
4.13 83
105

2.34
60
1.70
43

Figure 5: Dimensions for NEMA 1 General Purpose, Surface-Mounting Enclosures


Standard Size
Mounting Holes .25 dia. (2)
6

3.00 OFF 4.25


76 108

2.75 1.63
70 41 Pilot
2.44 Light
2.88
73 62
0.56
14
0.41
10

1.06
27
Type FG2P
0.5–0.75 in. Conduit Knockout, Both Ends

9
© 1997–2016 Schneider Electric 12/2016
All Rights Reserved
Manual Starters and Switches
Approximate Dimensions, Types F and K

Figure 6: Dimensions for NEMA 1 General Purpose Surface Mounting Enclosures—


Oversized
Mountig Holes .25 dia. (2)
6

3.00 OFF 4.25


76 108

2.75 1.63
70 41 Pilot
2.88 Light
2.88
73 73
0.56
14
0.69
17
1.06
27

1/2–3/4" Conduit Knockout, Both Ends

Figure 7: Dimensions for NEMA 1 General Purpose, Surface-Mounting Enclosures—


Jumbo Size

3.28
4.86 83
123 0.71
18

OFF 4.35 2.20


110 56

3.09
Pilot Light
78

Table 13: Dimensions for General Purpose, Flush-Mounting

Operator Dimensions (in.)


Device Class 2510 Type
Style A B C
FF1, 1P, 2, 2P
1.44 2.75 4.5
Toggle FS1, 1P, 2, 2P
FSJ1P, 2P 1.44 3.5 5.25 OFF C 2.56
Type F 65
FF3, 3P, 4, 4P
1.44 2.75 4.5
Key FS3, 3P, 4, 4P
FSJ3P, 4P 1.44 3.5 5.25
KF1, 1A, 1B .50
KF2, 2B, 2C 13 0.66
1.75 2.75 4.5 B
KS1, 1A, 1B
Toggle KS2, 2B, 2C 1.78 17
45
KSJ1A, 1B
1.75 3.5 5.25 Pilot
KSJ2B, 2C
Type K Light
KF3, 3A, 3B
KF4, 4B, 4C .75
1.75 2.75 4.5 A
KS3, 3A, 3B 1.69 .91 19
Key KS4, 4B, 4C 43 23
KSJ3A, 3B
1.75 3.5 5.25
KSJ4B, 4C

10
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Approximate Dimensions, Types F and K

Figure 8: Dimensions for NEMA 3R, 7, and 9 Cast Aluminum Enclosure for
Hazardous Locations
3.95 4.35
100 2x 0.30
1.37 8 110
35

6.36
161

ON Device Class Type


Type F 2510 FR1, 2
5.75
146
Type K 2510 KR1, 2
OFF

Class 2510 Type KR2H


0.28 Padlock Hole
NEMA 3R, 7 & 9 7
Weight: 3.5 lb Conduit Centerline
3/4-14 Pipe Tap,
0.31 Bottom Only 1.19
2x Mounting Holes 1.37 0.70
8 30
35 18

Figure 9: Dimensions for NEMA 4 Watertight Die Cast Zinc Enclosure


3
76 2.75 4.56
.25 1.13 70 116 4.25
6 29 108
(2) .22 Dia. Mounting Hole Device Class Type
6 Type F 2510 FW1, 1P, 2, 2P
Pilot Light KW1, 1A, 1B
KW2, 2B, 2C
ON Type K 2510
3.75 KW5, 5A, 5B
95 KW6, 6B, 6C
OFF 4.38
111

.28 Dia. Padlock Hole


7
NEMA 4 1.13 .31 3" 14 Pipe Tap .78
Weight: 3.0 lb 29 8 4 20
Conduit Center Line

Table 14: Two-Unit Devices—NEMA 1 General Purpose Enclosure


Device Operator Style Class Type
Toggle 2510 FGO2, FGO2P
One Starter
Key 2510 FGO4P
Toggle 2510 FG22, FG22P
Two Starters
Key 2510 FG44P

One Starter and One Toggle 2510 FG71, FG71P, FG72, FG72P
Selector Switch [1] Key 2510 FG74P
Reversing Switch [2] Toggle 2511 KG11, KG11A, KG11B, KG22A, KG22B, KG22C
Two-Speed Starter Toggle 2512 FG11, FG11P, FG22, FG22P
Two-Speed Switch Toggle 2512 KG11, KG11A, KG11B, KG22, KG22B, KG22C
[1] The selector switch is on the left. It increases the overall depth to 3.5 in.
[2] Only one pilot light (located on the right) is used on Class 2511 switches.

See the dimensional drawings in Figure 10 on page 12.

11
© 1997–2016 Schneider Electric 12/2016
All Rights Reserved
Manual Starters and Switches
Approximate Dimensions, Types F and K

Figure 10: Dimension Drawing for Two-Unit NEMA 1 General Purpose Enclosure
.25
(4) Dia. Mtg. Holes
6

Pilot
Light
3.00
OFF OFF 76

4.25
108

2.75 .38 1.88 1.88 2.56


10 48 48 0.56
70 65
2.88 4.50 14 2.63
73 114 67
3.81
97

Class 2511 Type KG22


Class 2511 Type KG22
(Cover Removed)
(Cover) 1.06
27

0.5–0.75 Conduit Knockout, Both Ends

Table 15: Two-Unit General Purpose Flush Mounting Plate

Operator Dimensions
Device Class Type
Style A B C D
FF22, FF22P 5.25 3.75 5.25 1.44
Toggle 2510
FS22P 4.56 3.5 4.5 1.44
Two Starters
FF44P 5.25 3.75 5.25 1.44
Key 2510
FS44P 4.56 3.5 4.5 1.44
FF71, FF71P, FF72, FF72P 5.25 3.75 5.25 2.0
Toggle 2510
One Starter and One FS71P, FS72P 4.56 3.5 4.5 2.0
Selector Switch [1] FF74P 5.25 3.75 5.25 2.0
Key 2510
FS74P 4.56 3.5 4.5 2.0
KF11, KF11A, KF11B
Reversing Switch [2] Toggle 2511 5.25 3.75 5.25 1.75
KF22, KF22A, KF22B, KF22C
Two-Speed Starter Toggle 2512 FF11, FF11P, FF22, FF22P 5.25 3.75 5.25 1.44
KF11, KF11A, KF11B
Two-Speed Switch Toggle 2512 5.25 3.75 5.25 1.75
KF22, KF22B, KF22C
Class 2512 Type KF22
[1] The selector switch is on the left and extends 1.63 in. from the mounting surface.
[2] Dimensions include factory-wired power connections.

Figure 11: Dimension Drawing for Two-Unit General Purpose Flush Mounting Plate

OFF OFF C

2.56
65

A Pilot
Light

.75
D
19
.91
23 B

12
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Class 2510, 2511, 2512 Integral Horsepower Starters—Types M and T

Class 2510, 2511, 2512 Integral Horsepower Starters—Types M and T

Application Data

Types M and T integral horsepower manual starters provide convenient On-Off operation of small
single-phase, polyphase, or DC motors. Typical applications include small machine tools, pumps, fans,
and conveyors. They feature push button or toggle operators and reliable overload protection. Pilot
lights and auxiliary contacts are available. For modifications, see page 17.
Class 2510 Size: Available in NEMA Sizes M-0, M-1, and M-1P
Type M and T
in General Purpose Poles:
Enclosure
AC: Two poles single-phase; three poles polyphase
DC: 2 poles (3 poles in series)
Voltage Rating: 600 Vac maximum, 250 Vdc maximum
Overload Relays: Melting alloy thermal overload relays have provisions for one Type B thermal unit
for single-phase starters, or three Type B thermal units for three-phase starters. All thermal units must
be installed, and the device reset, before the starter contacts will operate. After an overload relay trips,
wait one or two minutes before resetting to allow the alloy to solidify.
Operator: Open and NEMA 1 versions are available with a push button or toggle operator. NEMA 4
and 12 are available with a direct-acting push button only. NEMA 4X and 7 & 9 use an external toggle
to actuate a push button device inside.
Mechanism Lock Off: Open devices and starters in the following enclosures can be locked in the Off
or Stop position: NEMA 1 surface and flush mounting; and NEMA 4, 4X, 7 & 9, and 12 .
Devices in the following enclosures can also be locked closed to prevent unauthorized entry: NEMA 1
surface mounting; and NEMA 4, 4X, and 12 . NEMA 7 & 9 enclosures are bolted closed.
Size M-1, 3-Pole Table 16: Terminals
Push Button Operated
Power Terminals Auxiliary Interlock Terminals
NEMA Size Wire Range Wire Range
Type of Lug Type of Lug
Solid or stranded copper wire Solid or stranded copper wire

Approvals M-0 Pressure Wire 14–8 Pressure Wire 16–12


M-1 Pressure Wire 14–8 Pressure Wire 16–12
M-2 Box Lug 14–6 Pressure Wire 16–12
All Except
NEMA 7 & 9
Table 17: Maintenance of Equipment
File E42243 For proper performance, all equipment should be periodically inspected and maintained.
CCN NLRV
Replacement contacts and interlocks are available in kit form to facilitate servicing and stocking.
In addition, the instruction bulletin listed in the following table contains an exploded view of the device
File LR60905 with components clearly marked for easy identification by description and part number.
Class 3211 05
NOTE: Consult instruction bulletin 30072-013-19 (312AS).

NEMA 7 & 9 Only Replacement Contact Kit


NEMA Size Number of Poles
Class 9998, Type
File E78503
M-0 2 or 3 ML1
CCN NPXZ
M-1 2 or 3 ML2
M-1P 2 ML2
File LR60905
Class 3218 04

13
© 1997–2016 Schneider Electric 12/2016
All Rights Reserved
Manual Starters and Switches
Class 2510, 2511, 2512 Integral Horsepower Starters—Types M and T

Accessories and Modification Kits: One auxiliary contact, either N.O. or N.C., can be easily added
internally to any open or enclosed Type M or T manual starter. It occupies the space provided in either
the upper right or left corners of the device. These contacts are for AC loads only.
A unique red pilot light assembly that clips into place is available factory-installed on NEMA 1, 4, 4X,
12, and flush enclosures. The assembly is also available as a field modification kit for NEMA 1 surface
or flush mounting enclosures. The color cap assembly snaps into a knockout in the enclosure cover on
the NEMA 1 enclosures. Pilot light kits are available for use on various voltages, 110–600 V. (Pilot light
assemblies are not available for NEMA 7 & 9 enclosures.)
Class 2511 reversing manual starters consist of two mechanically interlocked Class 2510 Type M or
T manual starters. They are available in NEMA 1 surface-mounting enclosures or as open type.
Class 2512 two-speed manual starters are for wye-connected separate winding motors only. They
consist of two mechanically interlocked Class 2510 Type M or T manual starters.

NEMA 4/4X Starters will not operate unless the thermal units have been properly installed (with the markings
Watertight and Dusttight facing the front of the starter) and the device has been reset.
Stainless Steel
Table 18: Class 2510 Device Type Numbers—Non-Reversing,
Integral Horsepower Manual Starters, 600 Vac Maximum
Ratings NEMA Enclosure Open Style
NEMA 1 NEMA 4/4X Watertight, Dusttight, NEMA 7 & 9 [1] for NEMA 12 [2] Square
No. of NEMA Max. HP
Motor Surface Mounting and Corrosion-Resistant Hazardous Locations Dusttight Push Toggle
Poles Size
Voltage Poly- Single Square Push Button Toggle Brushed Class I : Grps C, D and Driptight Button Operator
Glass Polyester Class II : Grps E, F, G Industrial Use Operator
Phase Phase Operator Operator Stainless Steel
115 — 1
M-0 MBG1 TBG1 MBW11 [3] MBW1 [3] MBR1 [3] MBA1 [3] MBO1 TBO1
230 — 2
2 115 — 2
M-1 MCG1 TCG1 MCW11 MCW1 MCR1 MCA1 MCO1 TCO1
Pole 230 — 3
115 — 3
M-1P MCG2 TCG2 MCW12 MCW2 MCR2 MCA2 MCO2 TCO2
230 — 5
115 — —
M-0 200–230 3 — MBG2 TBG2 MBW12 [3] MBW2 [3] MBR2 [3] MBA2 [3] MBO2 TBO2
3 380–575 5 —
Pole 115 — —
M-1 200–230 7.5 — MCG3 TCG3 MCW13 MCW3 MCR3 MCA3 MCO3 TCO3
380–575 10 —
115 1 hp, DC
DC M-0 MBG4 TBG4 MBW14 MBW4 — MBA4 MBO4 TBO4
230 1.5 hp, DC
2
Pole 115 1.5 hp, DC
M-1 MCG5 TCG5 MCW15 MCW5 MCR5 MCA5 MCO5 TCO5
230 2 hp, DC
[1] For NEMA 7 & 9, these Type numbers are for cast-iron enclosures. For outdoor use, NEMA 4X and 7 & 9 cast-aluminum enclosures are available; to order these enclosures, replace the R in the
Type number with a T. For additional information, contact your local Square D™ field sales office.
[2] NEMA 12 enclosures can be field modified for outdoor applications.
[3] Approved for group motor installations in accordance with NEC 430-53(c).

Table 19: Class 2511 Device Type Numbers—Reversing Manual Starters


NEMA 1
Ratings Open Type
Number of NEMA Surface Mounting
Poles Size Motor Maximum Square Push Button Toggle Square Push Button Toggle
Voltage Horsepower Operator Operator Operator Operator
200–230 3
M-0 MBG1 TBG1 MBO1 TBO1
3 380–575 5
Pole 200–230 7.5
M-1 MCG1 TCG1 MCO1 TCO1
380–575 10

Table 20: Class 2512 Device Type Numbers—Two-Speed Manual Starters


Ratings NEMA 1 Surface Mounting Open Type
Number NEMA
of Poles Size Motor Constant Constant or Square Push Button Toggle Square Push Button Toggle
Voltage Horsepower Variable Torque Operator Operator Operator Operator
200-230 2 3
NEMA 12 M-0 MBG1 TBG1 MBO1 TBO1
3 380-575 3 5
Driptight and Dusttight
Industrial Use Pole 200-230 5 7.5
M-1 MCG1 TCG1 MCO1 TCO1
380-575 7.5 10

14
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Class 2510, 2511, 2512 Integral Horsepower Starters—Types M and T

Figure 12: Dimensions for Class 2510 Starters


2.13 .22 3.91
54 6 99
1.06 1.02
3.50 .28 27 26
1.75 89 7 4.03
102 1.14
44 29
1.25
32 8.63
START START
219 .50 - .75 K.O.
5.13 Each Side
STOP
130 0.22 Dia.
STOP
RESET 5.75
RESET
5.72 146
(4) Mounting
1.13 145
29 Holes

1.44
37
.69 Prov. for 0.44 Travel to
18 (3) #10 11 Reset 1.00 3.00 (2) .50–.75 K.O. 1.02
1.13 Mounting
25 76
Top and Bottom 26
29 3.97 5.00
Screws 101 127

NEMA 4/4X Class 2510 Type M, Open Style Class 2510 Types M and T, Sizes M-0 and M-1
Watertight, Dusttight, and Sizes M-0, M-1, M-1P NEMA 1 General Purpose Enclosure
Corrosion-Resistant Approximate Shipping Weight: 3 lb Approximate Shipping Weight: 5 lb
Glass Polyester
3.38 .22 5.00
86 .88 6 127
.94 1.69 22 1.06 5.78 .75 Conduit Hub 1.31
24 43 27 147 Top and Bottom 33
1.27 3.25 .38 NEMA 4/4X
1.00 32 83 10
25

.50 - .75 K.O. 10.00 .50 - .75 K.O. .31 Dia. .47
(2) Top Back START
254 (2) Each Side (2) Mounting 12
Holes 10.75
STOP
RESET 8.13 START 273
207 10.92
STOP
RESET 10.00 277
.22 Dia. 254
(3) Mounting
Holes
1.00 1.00
25 25
.94 4.13
24 105 (1) .50 - .75 K.O.
6.00 (2) .75 - 1.00 K.O. 1.06 2.89 5.76
152 Top and Bottom (2) .31 Wide Slots
27 73 146

Class 2510 Types M and T, Size M-1P Class 2510 Type M Sizes M-0, M-1, and M-1P
NEMA 1 General Purpose Enclosure NEMA 4/4X Watertight Stainless Steel Enclosure
Approximate Shipping Weight: 5 lb NEMA 12 Dusttight Industrial Use Enclosure
NEMA 7 & 9 Approximate Shipping Weight: 9 lb
Hazardous Location
Cast Iron
5.78 6.50 .75 6.41
147 165 19 163
.75 5.00
19 127 1.28
33
1.69
R
43
E ON
S
8.75
E 222
T R ON
E
S
OFF 7.31 10.34 E
T
186 263 OFF
8.75
(2) .31 Dia. 222
Mtg. Holes 12.13
308
(2) .31 Dia.
Mtg. Holes
1.69
.72 3.69 .75 Conduit Hub 43
18 94 .72 Top and Bottom
5.13 18 .81 1.41 .75 Conduit Hub
21 36 2.19 In Top and Bottom
130 56

Class 2510 Type M, Size M-0 (AC or DC) and M-1 (DC) Class 2510 Type M Sizes M-1 and M-1P (AC)
NEMA 4/4X Watertight, Corrosion-Resistant NEMA 4/4X Watertight, Corrosion-Resistant
Glass Polyester Enclosure Glass Polyester Enclosure
Approximate Shipping Weight: 6 lb Approximate Shipping Weight: 6 lb

15
© 1997–2016 Schneider Electric 12/2016
All Rights Reserved
Manual Starters and Switches
Class 2510, 2511, 2512 Integral Horsepower Starters—Types M and T

Figure 13: Dimensions for Class 2510, 2511, and 2512 Starters

6.00
152
.66 4.69 .34 6.13
17 119 9 156

R ON
E
S
E
10.50
T
267
OFF 9.94
252

(4) .13 Wide


Mtg. Slots

2.34 (1) .75 Conduit Top and Bottom (Std.)


59 (1) 1.50 Conduit Top and Bottom (Max.)

Class 2510 Type M, Sizes M-0, M-1, and M-1P


NEMA 7 & 9 Hazardous Location
Cast Iron Enclosure
Approximate Shipping Weight: 18 lb

.28 Dia.
(3) .5 -.75 K.O. .22
Top and Bottom 6
Mtg. Holes
START START

STOP STOP 9.34


RESET RESET
237
4.25
7.88 108
200

1.69
.75 43 1.28
7.25 19
3.38 33
184 86
8.94 .84
227 21

Class 2511 and 2512 Types M and T


Sizes M-0 and M-1
NEMA 1 General Purpose Enclosure
Approximate Shipping Weight: 9 lb

16
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Accessories, Modifications, and Renewal Parts

Accessories, Modifications, and Renewal Parts

Table 21: Accessories for Table 23: Replacement Nameplates for Class 2510 Types F and K
Class 2510 Types F and K
Nameplate Type Number—Class 2510
Description Class and Type For Type F Starter
Nameplate For Type K Switch (Includes Reset
Handle Guard Kit with Padlock Provision [1] 2510 FL1 Description Application
Marking Indication)
Emergency Off Actuator 2510 PB1 Pilot Light
Additional Key for Key Operated Devices 2510 FK1 Without With Without With
[1] Standard on Type K devices. 1-3/4" x 2-13/16" Standard commercial Blank FN1 — FN2 —
Nameplate with switch box cover or
Embossed Mounting flush plate, including Special marking
Table 22: Replacement Parts Holes for #6 Oval Square D™ stainless (specify the FN5 — FN6 —
Head Screws steel plates marking)
Description Class and Type
Blank FN10 FN20 FN30 FN40
Replacement Toggle Kits:
Type FW and KW (NEMA 4) 9998 HW1 High FN11 FN21 FN31 FN41
Type FR and KR (NEMA 7 & 9) 9998 HR2 1-29/32" x 3-27/32"
Square D NEMA 1 Low FN12 FN22 FN32 FN42
Replacement Handle Kits: Flat Nameplate with
surface mounted Forward FN13 — — —
Type MBA, MCA, MBW, MCW (NEMA 4 and12) 9998 HWA1 Mounting Holes for
enclosure or gray
Type MBR, MCR, MBW, MCW (NEMA 4X, 7 & 9) 9998 HR3 #6 Pan Head Reverse FN14 FN24 — —
flush plate
Screws
Internal Lever 9998 IL1 Special marking
(specify the FN15 FN25 FN35 FN45
marking)

Table 24: Pilot Light Kits for Table 25: Enclosures


Class 2510 Types F and K
For use with Class 2510 Type Enclosure Catalog No.
Class and Type F and K 9991EN1
Application Voltage Pilot Light M: Sizes M-0 and M-1 NEMA 1 Standard 9991MG1
Red Green M: Size M-1P 9991MG2
110–120 Vac 9999PL11 9999PL11G NEMA 1 Flush Mounting
9991MF1
Type KF, KG, KW with pull box and plaster adjustment
[1] 208–277 Vac 9999PL12 9999PL12G
NEMA 1 Flush Mounting
440–600 Vac 9999PL13 9999PL13G MBO and MCO 9991MF2
without pullbox but with mounting strap
Type FF or FG 115–240 Vac/Vdc 9999PL10 9999PL10G NEMA 4/4X (Polyester) 9991MW1
[1] The lens cannot be replaced. Kits for NEMA 4 replacement only. NEMA 4/4X (Stainless Steel) 9991MW11
FO1, FO1P, FO2, FO2P, FO3, FO3P, FO4, FO4P NEMA 1 Oversized 9991FE1
NEMA 1 Oversized 9991KE1
KO1, KO1A, KO1B, KO2, KO2B, KO2C, KO3,
KO3A, KO3B, KO4, KO4B, KO4C, KO5, KO5A, NEMA 1 Jumbo 9991KE2
KO5B, KO6, KO6B, KO6C
NEMA 3R 9991KE3

Table 26: P11 Pilot Light Voltage Codes Table 27: Modifications (Types M and T Only)
for Class 2510, 2511, and 2512, Type M and T
Factory Modifications: Field Modifications:
Description
Form Number Kit Class and Type
Voltage Code
9999MP1 (110–120 V )
120 V V02 Red Pilot Light [1] P11 [2] 9999MP2 (208–240 V )
200/208 V V08 9999MP3 (440–600 V )

230 V V03 X1 (1 N.O.) 9999SX11 (N.O.)


Auxiliary Contacts [3]
X2 (1 N.C.) 9999SX12 (N.C.)
460 V V06
Jumper Straps [4] N/A 9998SO31
575 V V07
Contactor Only Y76 (does not change starter dimensions) N/A
[1] Can only be field-added to NEMA 1 enclosures.
[2] P11 pilot lights require a voltage code.
[3] For proper operation, only one auxiliary contact kit per device is allowed to be added.
[4] For controlling a single-phase motor with a three-phase starter.

17
© 1997–2016 Schneider Electric 12/2016
All Rights Reserved
Manual Starters and Switches
Class 2601 Reversing Drum Switches

Class 2601 Reversing Drum Switches

Reversing drum switches are designed to start and reverse motors by connecting them directly across-
the-line. The devices can be used with squirrel cage motors; single-phase motors designed for
reversing service; and series, shunt, and compound DC motors. The applications should be such that
across-the-line starting of the motors is not objectionable, unless other means is provided for limiting
starting current and torque. Class 2601 drum switches are field convertible from maintained to
momentary operation.

Application Data
Type AG2
The reversing drum switches are particularly suited for use in manual reversing control applications
such as machine tools, woodworking machines, and similar types of equipment. Examples include
lathes, milling machines, planers, grinders, shapers, and boring mills. Other possible applications
include door operators, small hoists, and conveyor belts.
Overload and low-voltage protection are not incorporated into these reversing drum switches. Should
the power fail, the contacts will remain closed unless assembled for momentary operation, and the
handle will stay in the selected position. The motor will restart when the power returns.
.

Voltage 600 Vac Maximum


250 Vdc Maximum
Contact Mechanism Large movable contact segments are rigidly attached to the main
operating shaft. They are fully insulated from each other and from the
shaft. Stationary contact fingers are mounted in polymeric blocks.
Type AW2
Both movable and stationary contacts are plated for maximum life.
Easily accessible terminals are provided to simplify wiring. Type A is
provided with screw-type terminals and Type B is provided with
pressure-wire connector terminals. Contacts are not replaceable.
Operating Mechanism The operating mechanism is factory assembled for Maintained
Position operation. That is, when the handle is moved to the forward
or reverse position, it will remain there until moved. The mechanism
can easily be converted to provide Spring-Return-to-Off operation,
with no additional parts needed. This conversion is accomplished by
removing the handle screw and handle, turning the shaft 180 degrees,
and then replacing the handle and handle screw.
Handles Both the NEMA 1 and NEMA 4 devices come standard with a one-
piece molded handle.
Enclosures The polymeric NEMA 1 enclosure is suitable for indoor applications
when normal atmospheric conditions prevail. The NEMA 4 enclosure
is suitable for applications requiring watertight and dusttight
capabilities. Generous wiring space is provided in both types. Two
knockouts or openings for 1/2 in. conduit entries are located in the
bottom plate of Types AG and BG, while two 1/2 in. conduit entries
with hubs come standard on Types AW and BW.
A single captive screw holds the cover on NEMA 1 enclosures, while
three captive screws hold the cover on NEMA 4 enclosures.
Removing the cover allows free access to three sides of the switch
mechanism. Large, legible nameplates are securely attached to the
enclosures to clearly indicate switching positions and to provide
complete rating information. An instruction sheet showing typical
motor connections is also included.

18
12/2016 © 1997–2016 Schneider Electric
All Rights Reserved
Manual Starters and Switches
Class 2601 Reversing Drum Switches

Table 28: Class 2601 Device Types—NEMA 1, 4, and 13—without Overload Protection
Internal Switching
Ratings Device Type, 600 Vac Maximum Device Type, 360 Vdc Maximum
1 2 1 2 1 2
Maximum Horsepower Enclosure Enclosure
3 4 3 4 3 4
Volts NEMA 1 NEMA 4 NEMA 1 NEMA 13
AC AC
5 6 5 6 5 6 DC General Watertight and Maintained and Oiltight
1-Phase Polyphase
Purpose Dusttight Momentary [1] Flush Mounting
Reverse Off Forward
115 1.5 — 0.25
200/230 — 2 —
AG2 AW2 AG2S2 AF2
230 2 — 0.25
460/575 — 2 —
Three-Phase Wiring Diagram
115 1.5 — 2
T1 L1 200/230 — 5 —
L2 BG1 BW1 — —
230 3 — 2
T2 460/575 5 7.5 —
T3 L3
[1] Maintained–Forward; Momentary–Reverse. Not field convertible.

Figure 14: Approximate Dimensions

3.38 5.58 6.89


86 142 175
3.81
97

5.20 5.50 (2) 1/2" NPT


140 Pipe Thread
132 3.19 3.70 2.77
81 94 70
File E42243 1.82
CCN NLRV 46

2.38 .20 3.20


60 5 81
2.87 (4) .17 Mounting Holes .60
File LR25490 73 15
Class 3211 05 Class 2601 Type AF2 Class 2601 Types AW and BW
dimensions = in.
mm

5.38
4.00 6.62
5.18

2.68 2.91
3.26 3.53
4.61
4.86

(2) K.O. For 1/2" Conduits

dimensions (in.) = AG/AH


BG

Class 2601 Types AG, BG

19
© 1997–2016 Schneider Electric 12/2016
All Rights Reserved
Schneider Electric USA, Inc. Schneider Electric and Square D are trademarks and the property of Schneider Electric SE, its
subsidiaries, and affiliated companies. All other trademarks are the property of their respective
800 Federal Street owners.
Andover, MA 01810 USA
888-778-2733 2510CT9701R01/16 Replaces 2510CT9701, 12/1997
www.schneider-electric.us © 1997–2016 Schneider Electric All Rights Reserved

12/2016

You might also like