CMP-200

Indeks: WMXXCMP200
Digital Clamp-on AC leakage current
meter

Description
The CMP-200 digital clamp meter has been designed for clamp
measurements of AC leakage current.
AC current measurement up to 200 A.
high resolution (0,1 mA),
three measuring ranges: 200 mA, 2 A, 200 A.
The most important features of CMP-200 are:
display LCD 3½ digits (max 1999),
white LED backlight,
internal diameter clamp approx. 30 mm (1,2"),
DATA HOLD function, for holding measured values.
MAX function,
AUTO-OFF function,
double molded casing.

Technical Specification
The CMP-200 digital clamp meter has been designed for clamp
measurements of AC leakage current.
AC current measurement up to 200 A.

high resolution (0,1 mA),


three measuring ranges: 200 mA, 2 A, 200 A.

The most important features of CMP-200 are:

display LCD 3½ digits (max 1999),


white LED backlight,
internal diameter clamp approx. 30 mm (1,2”),
„DATA HOLD” function, for holding measured values.
„MAX” function,
„AUTO-OFF” function,
double molded casing.

AC current measurement

Range 199,9 mA

Resolution 0,1 mA

Accuracy ±(5% m.v + 8 dgt)

Range 1,999 A

Resolution 0,001 A

Accuracy ±(5% m.v. + 10 dgt)

Range 199,9 A

Resolution 0,1 A

Accuracy ±(2,5% m.v. + 10 dgt)

„m.v.”- measured value

Electric security:

type of insulation: double, according to EN 61010 - 1 And IEC


61557
measurement category: CAT II 600 V acc. to EN 61010 - 1:2004
protection class acc. to EN 60529: IP40

Other technical data:

power supply: 1,5 V AAA battery (2 pcs.)


over range indication: 0L displayed
sampling rate: 2 times per second
display: 1999 counts LCD, 3½ digits
dimensions: 182 x 61 x 34 mm
weight (including batteries): 225 g
auto power OFF: 15 min.
accordance with following standards: EN 61010 - 1:2004, EN
61010 - 2 - 032
quality standard: ISO 9001

Rated operational conditions:

operating temperature and humidity: 0...+30°C (max 90%),


30...40°C (max 75%), 40...50°C (max 45%)
storage temperature: -25...+60°C max <90%
operating altitude: max 3000 m