0% found this document useful (0 votes)
178 views1 page

Marco

1. This welding inspection report documents a visual inspection of welds on an unspecified project. 2. The inspection checked for cracks, undercut, overlap, undersize, spatter, and porosity according to acceptance criteria in the AWS D1.1 structural welding code for steel. 3. The report lists no issues found and notes the inspection was performed, checked, and acknowledged according to proper roles and certification.

Uploaded by

bimbo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views1 page

Marco

1. This welding inspection report documents a visual inspection of welds on an unspecified project. 2. The inspection checked for cracks, undercut, overlap, undersize, spatter, and porosity according to acceptance criteria in the AWS D1.1 structural welding code for steel. 3. The report lists no issues found and notes the inspection was performed, checked, and acknowledged according to proper roles and certification.

Uploaded by

bimbo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

WELDING INSPECTION REPORT

Inspection Date : WIR No. :


Project : Shift : Day Night
Product Type : Type of Finished : Bare Galvanized

Visual Inspection
Item Joint Welding Voltage Ampere REMARKS
Description ID No. Arc Welder’s Name STATUS
No. No. Crack Undercut Overlap Undersize Spatter Porosity Process Range Range (J.O. No., etc.)
Strike

Visual Inspection Acceptance Criteria (AWS D1.1/D1.1M Structural Welding Code – Steel): LEGEND :
1. Any crack shall be unacceptable, regardless of size or location. V.I. - Visual Inspection
2. Thorough fusion shall exist between adjacent layer of weld metal and between ACC. - Accepted
weld metal and base metal.
3. All craters shall be filled to provide the specified weld size.
4. Undersize portion of the weld shall not exceed 10% of the weld length.
5. Undercut shall be no more than 1mm deep.
6. CJP groove weld in but joints transverse to the direction of computed tensile
stress shall have no piping porosity.

Inspected by : Marco Antonio Marasigan Checked by : Acknowledge by : Noted by :


Certified Welding Inspector Welding Inspector (PWS) Site Engr./Leadman/Foremen QA/QC Supervisor
Certification No. 2020-100334
QAS – FAB 0.06/01

You might also like