0% found this document useful (0 votes)
195 views4 pages

AC/DC Chassis Module: Single, Dual and Triple Output Series

- Efficiency up to 80% with universal input range of 85-265 VAC and short/over voltage protection - Single, dual, and triple output modules with 3000VAC isolation and MTBF >250,000 hours - Modules provide various DC voltage outputs from 5V to 48V with current output ranges from 63mA to 6000mA

Uploaded by

Fabio Martins
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
195 views4 pages

AC/DC Chassis Module: Single, Dual and Triple Output Series

- Efficiency up to 80% with universal input range of 85-265 VAC and short/over voltage protection - Single, dual, and triple output modules with 3000VAC isolation and MTBF >250,000 hours - Modules provide various DC voltage outputs from 5V to 48V with current output ranges from 63mA to 6000mA

Uploaded by

Fabio Martins
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

• Efficiency up to 80%

• Universal Input Range 85-265 VAC


• Single, Dual and Triple Output Modules
• 3000VAC Isolation

30 Watt AC/DC Chassis


• Short Circuit Protection
• Over Voltage Protection
• MTBF > 250,000 Hours
Module: Single, Dual • UL60950 Approved
and Triple Output Series • RoHS Compliant

Model Number Voltage Current


Capacitive
Input Efficiency
Output Output Load
115VAC, 60Hz

@ No Load @ Max Load Min Max Peak @ Max Load Max


(VDC) (mA) (mA) (mA) (mA) (mA) (%, Typ)

PC30J85S5 5 60 557 600 6000 ----- 78 8000 µF


PC30J85S12 12 60 543 250 2500 ----- 80 3900 µF
PC30J85S15 15 60 543 200 2000 ----- 80 3900 µF
PC30J85S24 24 60 543 125 1250 ----- 80 1500 µF
PC30J85S48 48 60 543 63 625 ----- 80 1000 µF
PC30J85D12 ±12 60 565 ±130 ±1300 ----- 80 1500 µF (each output)
PC30J85D15 ±15 60 543 ±100 ±1000 ----- 80 1500 µF (each output)
5 (Floating) 300 3000 4500 3900 µF
PC30J85D512 60 572 76
12 (Floating) 125 1250 1800 1500 µF
5 (Floating) 600 3000 4500 2200 µF
PC30J85T512 +12 60 572 120 600 900 76 1500 µF
-12 -120 -600 900 1500 µF
5 (Floating) 600 3000 4500 2200 µF
PC30J85T512A +12 60 572 200 1000 1500 76 1500 µF
-12 -50 -250 500 1500 µF
5 (Floating) 300 3000 4500 2200 µF
PC30J85T515 +15 60 572 50 500 750 76 1500 µF
-15 -50 -500 750 1500 µF
5 (Floating) 900 4500 6000 2200 µF
PC30J85T5312 +3.3 60 588 220 1000 1500 71 2200 µF
+12 50 250 500 1500 µF
3.3 (Floating) 800 4000 5300 2200 µF
PC30J85T3512 +5 60 483 300 1500 2000 71 2200 µF
+12 50 250 500 1500 µF

Dimensions are inches (mm) unless noted


Tolerance: Inches Millimeters
X.XX ±0.02 X.X ±0.5
X.XXX ±0.010 X.XX ±0.25
Pin ±0.004 ±0.1

Pin Connections
(NC) Not Connected
Pin Single Dual Dual Triple Triple
(D12, D15) (D512A) (T5312, T3512)
1 AC(N) - AC Neutral
2 AC(L) - AC Line
3 +Vout +Vout +Vout2 +Vout2 +Vout2
4 NC NC +Vout1 +Vout1 +Vout1
5 -Vout Common -Vout2 Common 2/3 Common 2/3
6 NC NC -Vout1 -Vout1 -Vout1
7 NC -Vout NC -Vout3 +Vout3

www.ConTech-us.com Email: [email protected] Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520
 17:2010/5/04
See Model Selection Table for Model Specific Parameters
Input Parameters Min Typ Max Units Notes:
85 265 VAC 1. Specifications typical at Ta=+25ºC, 115VAC, 60Hz input voltage,
Input Voltage Range rated output current unless otherwise noted.
120 370 VDC 2. ConTech power converters require a minimum output loading to
Input Frequency 47 440 Hz maintain specified regulation. Operation under no-load conditions
will not damage these modules; however, they may not meet all
Switching Frequency 100 kHz specifications listed.
InrushCurrent 115VAC 20 A 3. The series has a limitation of a maximum connected capacitance at
(Cold Start at 25ºC) the output. The power module may be operated in current limiting
230VAC 40 A
mode during start-up, affecting the ramp-up and the startup time.
Output Parameters Min Typ Max Units 4. Ripple & Noise measurement bandwidth is 0-20MHz.
5. Cross Regulation - Measured output Io = 20% to 100% of rated
Output Voltage Accuracy
load. Other outputs are set at 50% of rated load.
Single / Dual Output ±1.0 ±2.0 % 6. Peak current can not be drawn from all outputs at the same time.
7. Floating (or isolated) output of a power supply that is not connected
Dual Positive / Vo1 ±1.0 ±2.0 % to any other output.
Triple Output Vo2 & Vo3 ±3.0 % 8. Long term short circuit operation may cause damage to the unit.
9. Water washability - ConTech AC/DC converters are designed to
Load Regulation lout = Min. to Max. withstand most solder/wash processes. Careful attention should be
used when assessing the applicability in your specific manufacturing
Single Output Models ±0.5 ±1.0 process. Converters are not hermetically sealed.
Dual Output Models ±2.5 ±5.0 10. See ConTech website for Definition of Terms, Application Notes,
and Test Setups and Parameters. www.ConTech-us.com/appnotes.
Vo1 ±2.5 ±5.0 html
Triple Output Models 11. Specifications subject to change without notice.
Vo2 & Vo3 ±4.0
12. See ConTech website www.ConTech-us.com/pdf/rohs.pdf for
Line Regulation Vin=Min. to Max. ±0.2 ±1.0 % RoHS Statement.
Cross Regulation - Vo1 %
Dual Positives /
Vo2 %
Triple Output (Note 5)
Vo3 %
Ripple & Noise (20MHz)
3.3 and 5.0VDC Output Models 1.5 1.8 %Vpp
Other Output Models 1.0 1.3 of Vo
Over Voltage Protection % of
120
Zener diode clamp Vo
Temperature Coefficient ±0.02 % / ºC
Overshoot 5 %
Current Limitation
105 %
85VAC Hiccup Technique, auto recovery
Short Circuit Protection Hiccup mode, indefinite
(automatic recovery)
Derating Curve
General Specifications Min Typ Max Units
To avoid exceeding the maximum temperature rating of the
Isolation Voltage, components inside the power module, the case temperature
3000 VAC
60 seconds must be kept below 90ºC.
Isolation Resistance
100 Mohms
500VDC
Hold-up Time (115VAC, 60Hz) 20 ms
Operating Temperature (Ambient) -10 +71 ºC Input Fuse Selection Table
Storage Temperature -40 +85 ºC Built In Fuse 6A - 250VAC
Humidity 95 % External Fuse 1.5A Slow-Blow Type
(Recommended)
MTBF MIL-HDBK-217F @25ºC, Ground K
250 External fusing should be used for system protection
Benign Hours
due to a catastrophic failure. See ConTech website
Cooling Free-Air Convection for Fusing Application Notes to determine the correct
Case Size 4.41 x 2.51 x 1.01 inches fuse.
112.0 x 63.8 x 25.6 mm
Case Material Plastic Resin + Fiberglass
(UL94V-0)
Weight 191g
Agency Approvals UL60950 Approved

www.ConTech-us.com Email: [email protected] Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520

Block Diagrams

Single Output

Dual Output
(D12, D15)

Dual Output
(D512)

Triple Output

Triple Output
(T3512, T5312)

www.ConTech-us.com Email: [email protected] Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520

Block Diagrams for UL508

Single Output

Dual Output
(D12, D15)

www.ConTech-us.com Email: [email protected] Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520


You might also like