AC/DC Chassis Module: Single, Dual and Triple Output Series
AC/DC Chassis Module: Single, Dual and Triple Output Series
Pin Connections
(NC) Not Connected
Pin Single Dual Dual Triple Triple
(D12, D15) (D512A) (T5312, T3512)
1 AC(N) - AC Neutral
2 AC(L) - AC Line
3 +Vout +Vout +Vout2 +Vout2 +Vout2
4 NC NC +Vout1 +Vout1 +Vout1
5 -Vout Common -Vout2 Common 2/3 Common 2/3
6 NC NC -Vout1 -Vout1 -Vout1
7 NC -Vout NC -Vout3 +Vout3
www.ConTech-us.com Email: [email protected] Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520
17:2010/5/04
See Model Selection Table for Model Specific Parameters
Input Parameters Min Typ Max Units Notes:
85 265 VAC 1. Specifications typical at Ta=+25ºC, 115VAC, 60Hz input voltage,
Input Voltage Range rated output current unless otherwise noted.
120 370 VDC 2. ConTech power converters require a minimum output loading to
Input Frequency 47 440 Hz maintain specified regulation. Operation under no-load conditions
will not damage these modules; however, they may not meet all
Switching Frequency 100 kHz specifications listed.
InrushCurrent 115VAC 20 A 3. The series has a limitation of a maximum connected capacitance at
(Cold Start at 25ºC) the output. The power module may be operated in current limiting
230VAC 40 A
mode during start-up, affecting the ramp-up and the startup time.
Output Parameters Min Typ Max Units 4. Ripple & Noise measurement bandwidth is 0-20MHz.
5. Cross Regulation - Measured output Io = 20% to 100% of rated
Output Voltage Accuracy
load. Other outputs are set at 50% of rated load.
Single / Dual Output ±1.0 ±2.0 % 6. Peak current can not be drawn from all outputs at the same time.
7. Floating (or isolated) output of a power supply that is not connected
Dual Positive / Vo1 ±1.0 ±2.0 % to any other output.
Triple Output Vo2 & Vo3 ±3.0 % 8. Long term short circuit operation may cause damage to the unit.
9. Water washability - ConTech AC/DC converters are designed to
Load Regulation lout = Min. to Max. withstand most solder/wash processes. Careful attention should be
used when assessing the applicability in your specific manufacturing
Single Output Models ±0.5 ±1.0 process. Converters are not hermetically sealed.
Dual Output Models ±2.5 ±5.0 10. See ConTech website for Definition of Terms, Application Notes,
and Test Setups and Parameters. www.ConTech-us.com/appnotes.
Vo1 ±2.5 ±5.0 html
Triple Output Models 11. Specifications subject to change without notice.
Vo2 & Vo3 ±4.0
12. See ConTech website www.ConTech-us.com/pdf/rohs.pdf for
Line Regulation Vin=Min. to Max. ±0.2 ±1.0 % RoHS Statement.
Cross Regulation - Vo1 %
Dual Positives /
Vo2 %
Triple Output (Note 5)
Vo3 %
Ripple & Noise (20MHz)
3.3 and 5.0VDC Output Models 1.5 1.8 %Vpp
Other Output Models 1.0 1.3 of Vo
Over Voltage Protection % of
120
Zener diode clamp Vo
Temperature Coefficient ±0.02 % / ºC
Overshoot 5 %
Current Limitation
105 %
85VAC Hiccup Technique, auto recovery
Short Circuit Protection Hiccup mode, indefinite
(automatic recovery)
Derating Curve
General Specifications Min Typ Max Units
To avoid exceeding the maximum temperature rating of the
Isolation Voltage, components inside the power module, the case temperature
3000 VAC
60 seconds must be kept below 90ºC.
Isolation Resistance
100 Mohms
500VDC
Hold-up Time (115VAC, 60Hz) 20 ms
Operating Temperature (Ambient) -10 +71 ºC Input Fuse Selection Table
Storage Temperature -40 +85 ºC Built In Fuse 6A - 250VAC
Humidity 95 % External Fuse 1.5A Slow-Blow Type
(Recommended)
MTBF MIL-HDBK-217F @25ºC, Ground K
250 External fusing should be used for system protection
Benign Hours
due to a catastrophic failure. See ConTech website
Cooling Free-Air Convection for Fusing Application Notes to determine the correct
Case Size 4.41 x 2.51 x 1.01 inches fuse.
112.0 x 63.8 x 25.6 mm
Case Material Plastic Resin + Fiberglass
(UL94V-0)
Weight 191g
Agency Approvals UL60950 Approved
www.ConTech-us.com Email: [email protected] Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520
Block Diagrams
Single Output
Dual Output
(D12, D15)
Dual Output
(D512)
Triple Output
Triple Output
(T3512, T5312)
www.ConTech-us.com Email: [email protected] Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520
Block Diagrams for UL508
Single Output
Dual Output
(D12, D15)
www.ConTech-us.com Email: [email protected] Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520