This document contains 27 multiple choice questions about DC generators. The questions cover topics such as calculating generator output voltage and current given machine specifications, armature winding configurations, efficiency calculations, and more.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
146 views4 pages
Drill Problems On DC Generators
This document contains 27 multiple choice questions about DC generators. The questions cover topics such as calculating generator output voltage and current given machine specifications, armature winding configurations, efficiency calculations, and more.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4
Drill Problems on DC Generators
1. A DC generator has no-load output voltage of 120 volts. Its armature
circuit resistance is 0.95 ohm and its field coils are separately energized. If the load is rated at 2 kW at 115 V. Neglecting the effect of armature reactions, what will be the actual load current? A. 15.90 A B. 6.6 A C. 16.67 A D. 10.89 A 2. (EE/Oct’96). If the armature of an eight-pole machine were wound with a simplex wave winding, how many parallel paths would there be? A. 16 paths B. 8 paths C. 2 paths D. 4 paths 3. (EE/Mar’98). A four pole,DC generator with lap winding has 48 slots and 4 elements per slot. How many coils does it have? A. 48 B. 384 C. 192 D. 96 4. A six-pole dc generator has an armature winding with 504 conductors connected in six parallel paths. Calculate the generated voltage if each pole produces 1.65 x 106 maxwells and armature speed is 1800 rpm. A. 230 V B. 240 V C. 250 V D. NOTA 5. (EE/Oct’98). A 4-pole DC generator with duplex lap winding has 48 slots and four elements per slot. The flux per pole is 2.5 x 106 maxwells and it runs at 1500 rpm. What is the output voltage? A. 60 V B. 360 V C. 225 V D. 120 V 6. A four-pole generator having a wave wound armature winding has 51 slots, each slot containing 20 conductors. What will be the generated voltage of the machine when driven by 1500 rpm, assuming that the flux per pole to be 7.0 mWb? A. 237 V B. 227 V C. 220 V D. 357 V 7. Calculate the voltage generated by a four pole dc machine given the following particulars; number of slot in armature = 55, number of conductor per slot = 4, flux per pole = 2.62 x 106 maxwells, speed = 1200 rpm, and number of parallel paths in armature = 2. A. 230 V B. 240 V C. 250 V D. NOTA 8. A four-pole machine generates 250 V when operated at 1500 rpm. The flux per pole is 1.85x106 maxwells, the number of armature slots is 45 and the armature winding has two parallel paths. If the speed is decreased to 1350 rpm, what flux should the excitation be adjusted if the generated voltage is to remain the same. A. 1.056x106 maxwells B.2.056x106 maxwells C. 3.056x106 maxwells D. NOTA Drill Problems on DC Generators / /GMSJr / Page 1 9. An 8-pole dc shunt generator with 778 wave connected armature conductor and running at 500 rpm supplies a load of 12.5 resistance at terminal voltage of 250 V. The armature resistance is 0.24 and the field resistance is 250 . Find the flux per pole develop. A. 3.98 mWb B. 9.83 mWb C. 8.93 mWb D. NOTA 10. (EE/Oct’86). The no-load voltage of a 50-kW, 220 volts, and shunt generator in the FEU laboratory is 232 volts and rated load voltage is 220 volts. The armature resistance including brushes, is 0.026 ohm and the resistance of the shunt field resistance is 52 ohms. What is the induced electromagnetic force at rated load? A. 221.36 V B. 226.02 V C. 224.56 V D. 227.05 V 11. A shunt generator has a no load terminal voltage of 270 and a voltage of 240 when it delivers 180 ampere. Assume a straight line external characteristics and determine the load resistance when the current is 120 ampere. A. 2.08 B. 3.08 C. 4.08 D. NOTA 12. A short shunt compound generator has a shunt field resistance of 77, a series field resistance of 0.008, a commutating pole winding resistance of 0.005 and an armature resistance including brushes of 0.02 . When the armature current is 128 ampere, the generated emf is 234.2 V, what is the power delivered to the load?. A. 28.75 kW B. 31.2 kW C. 35.0 kW D. NOTA 13. A 10 kW, 250 V, 6 pole dc shunt generator runs at 1000 rpm when delivering full load. The armature has 534 lap connected conductors. Full load copper loss is 0.64 kW. The brush drop is 1 V. Determine the flux per pole. A. 10 mWb B. 20 mWb C. 30 mWb D. NOTA 14. (EE/Apr’92). A compound dynamo supplies a load of 20 kW at 400 V through a feeder having a resistance equal to 0.1 ohm. The shunt and series field resistance are 85 ohms and 0.06 ohm respectively. Determine the total electromotive force when the generator is connected long shunt. Assume a brush contact drop of 1 V per brush and an armature resistance of 0.1 ohm. A. 418.34 V B. 412.50 V C. 415.76 V D. 421.44 V
Drill Problems on DC Generators / /GMSJr / Page 2
15. (EE/Oct’96,Apr’97). A DC generator has no-load output voltage of 120 volts. Its armature circuit resistance is 0.95 ohm and its field coils are separately energized. If the load is rated at 2 kW at 115 V. Neglecting the effect of armature reaction, what power could be delivered to the load? A. 1,518 W B. 2,180 W C. 1,670 W D. 2,000 W 16. A long shunt compound generator has a shunt field resistance with 1200 turn per pole and a series field with 4.5 turns per pole. If the shunt field and series field ampere-turns are respectively 1200 and 196. What is the power delivered to the load when the terminal voltage is 230 V. A. 8976 W B. 9786 W C. 9868 W D. NOTA 17. A short shunt compound generator has a full load current of 60 ampere. If the series-field resistance is 0.04 and a diverter carries 24 ampere. What is the diverter resistance? A. 0.6 B. 0.06 C. 0.006 D. NOTA 18. The regulation of A 250 V shunt generator is 6 %. What is the no load voltage. A. 265 V B. 255 V C. 245 V D. NOTA 19. The rotational loss in a generator has found to be 780 W when the generated emf was 132 V. What is the rotational loss for the generated voltage of 126V. A. 473.4 W B. 744.5 W C. 843.4 W D. NOTA 20. A 10 kW, 220 V short shunt compound generator is operated at no load at the proper armature voltage and speed, from which the stray power loss calculation are determined to be 705 W. The shunt field resistance is 110 , the armature resistance is 0.265 , and the series field resistance is 0.035 . Assume a 2V brush drop and calculate the full load efficiency. A. 83.94 % B. 89.37% C. 87.93% D. NOTA 21. A 250 V shunt generator has a rated armature current of 40 A and the following losses at full load; friction and windage loss = 200 W, core loss = 260 W, shunt field loss = 100 W, brush contact loss = 80 W, armature copper loss = 400 W. Assuming the maximum efficiency occurs when the approximated constant losses are equal to those losses that vary as the square of the load. What is the armature current for the condition of maximum efficiency. A. 47.33 A B. 473.3 A C. 4.733 A D. NOTA
Drill Problems on DC Generators / /GMSJr / Page 3
22. A 250 V shunt generator has a full load armature current of 40 ampere, under which condition the losses are; friction and windage = 200 W, shunt field = 100 W, core loss = 260 W, brush contact loss = 120 W, armature copper loss = 400 W. For operation at maximum efficiency when the constant and losses are equal to those losses that vary as the square of the load. What is the maximum efficiency? A. 90.29 % B. 92.09% C. 91.02% D. NOTA 23. A 25 kW series generator has an efficiency of 85 % when operating at rated at rated load. If the stray power loss is 20 % of the full load loss, calculate the efficiency of the generator when delivering a load of 15 kW. Assuming that the stray power loss is substantially constant and the other losses vary as the square of the load. A. 88.47% B. 87.84% C. 84.87 % D. NOTA 24. EE/Oct’80). The field current of a 100 kW, 250-volt shunt generator is 5 amperes when delivering power at rated terminal voltage and rated load current. The combined armature and brush resistance is 0.01 ohm. Determine the efficiency of the generator. A. 97.2% B. 94.3% C. 98.2% D. 94.7% 25. (EE/Apr’87, Oct’89). The field current of a 180 kW, 250 volts DC shunt generator is a 6 A when running full load at rated terminal voltage. If the combined armature and brush resistance is 0.02 ohm, solve for the electrical efficiency of the generator. A. 92.13% B. 94.05 % C. 93.73% D. 91.87 % 26. (EE/June’90). The field circuit of a 200,000 watts, 230-V shunt generator is a 8 A when running full load at rated terminal voltage. If the combined brush and armature resistance is 0.03 ohm, solve for the electrical efficiency of the generator. A. 85.34 % B. 89.14 % C. 88.91 % D. 87.82 % 27. (EE/Apr’97). The armature of a shunt generator has 0.05 ohm effective resistance. Each brush has an effective resistance of 0.01 ohm. The terminal voltage is 100 volts while the current is 40 amperes. What is the efficiency? A. 95.15% B. 97.65% C. 97.30% D. 96.52%