Abb GC
Abb GC
Abb GC
ABB Totalflow
Edwin Teo
17 and 19, October , 2007
Slide 1
© Totalflow
Agenda
Overview
Overview of
of ABB
ABB Totalflow
Totalflow
Overview
Overview of
of New
New Field
Field Mounted
Mounted Analyzer
Analyzer
NGC
NGC Product
Product demonstration
demonstration
Overview
Overview Flow
Flow Computers
Computers and
and RTU
RTU
Questions
Questions
ABB Totalflow
Who Are We?
•Host Software
Who is ABB Totalflow?
Product Group in ABB’s Automation
Headquarters: Zurich, Switzerland Technology Division
Transmission
Distribution
© Totalflow Slide 4
© Totalflow Slide 5 Product Overview
Markets Served – ABB Totalflow
Gas Production Gas Transportation Gas Distribution
City Gate
Gas Wells
Pipeline
Gas Wells
City Gate
Gas Wells
GAS
PLANT
Industrial
Liquids User
Associated Gas
3rdGeneration
Original Model 8000
NGC
Launched 1996
Air
Methane Neo Pentane
Carbon Dioxide Isopentane
Ethane Normal Pentane
Propane Hexane +
Isobutane
Normal Butane
© Totalflow Slide 10
Typical Natural Gas Composition
Below is a “typical*” composition of a natural gas
calibration blend in Mole Percent (1153.8 Btu):
N2 = 0.24 %
CO2 = 1.31 %
C1 = 86.39 %
C2 = 6.16 %
C3 = 3.46 %
IC4 = 1.08 %
NC4 = 0.80 %
IC5 = 0.27 %
NC5 = 0.15 %
C6+ = 0.14 %
© Totalflow Slide 11
C1
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
Why On – Line Measurement ?
Seldom Agree.
Hardware
Hardwareand
andsoftware
softwareinfrastructure
infrastructure
32
32bit
bitdigital
digitalcontroller
controllerand
and32
32bit
bitanalog
analogsignal
signal
processor
processor
24
24bit
bitA/D
A/Dfor
foreach
eachdetector
detectorbead
bead
Optimized
Optimizeddetector
detectorbead
beadoperation
operation
Digital
Digitalpressure
pressureand
andtemperature
temperaturecontrol
control
Triple
Triplelevel
leveltemperature
temperaturecontrol
control
- Beads - Heater plate - -Feed
- Beads - Heater plate Feedthru
thru
Pressure
Pressuresensors
sensorsininoven
oven(no
(notemperature
temperature
compensation
compensationrequired)
required)
© Totalflow Slide 16
Enhanced
Enhancedinsensitivity
insensitivitytotopower
powersupply
supplyvariation
variation
Compact Modular Design
Built in Stream
selector Switching
Strong Arm 32
bit processor Field
running Terminations
Windows CE
EX Man-Machine
Port
Graphical Display
with Magnetic
Navigation Keys
© Totalflow Slide 17
Easy
EasyConnections
Connections
Versatile
VersatileSerial,
Serial,USB
USBand
andEthernet
Ethernetwith
with
aavariety
varietyofofModbus
ModbusProtocols
Protocols
Four
FourStreams
Streams
Any
Anycombination
combinationofofprocess
processand
and
calibration streams – examples:
calibration streams – examples:
4 process streams
4 process streams
3 process, 1 calibration
3 process, 1 calibration
2 process, 2 calibration
2 process, 2 calibration
Ex
ExMMI
MMIPort
Port
© Totalflow Slide 18
Mounts
MountsAtop
Atop2”
2”Pipe
Pipe
© Totalflow Slide 19
© Totalflow Slide 20
© Totalflow Slide 21
© Totalflow Slide 22
© Totalflow Slide 23
Analysis
Analysisinfrastructure
infrastructure
Individual
Individualpeak
peakgating
gatingand
andintegration
integration
Pressure
Pressureprogramming
programmingon onsample
sampleinject
inject
Optimized
Optimizedcycle
cycletime
time
Results
Results
Precision
Precision
+/- 0.125 Btu ambient
+/- 0.125 Btu ambient
+/- 0.25 Btu from 00 0F – 1310 0F (-18 to +55C)
+/- 0.25 Btu from 0 F – 131 F (-18 to +55C)
Reliable operation -20oF – 131oF (-29C to +55C)
Reliable operation -20oF – 131oF (-29C to +55C)
55ppm
ppmminimum
minimumdetection
detectionon
onNC
NC55and
andCO
CO22
© Totalflow Slide 29
Flexibility
Ways to connect
using PCCU32:
RS 232 Local
Device Connection
using PC Comm
port
USB Connection to
Local Device
Internet connection
using Fixed IP
address
Internet connection
© Totalflow Slide 30
Type 4 also
available (Type 3
with water shut-off)
Type 3
© Totalflow Slide 35 SAMPLE SYSTEM INSTALLATION
© Totalflow Slide 36 SAMPLE STREAM CONNECTION
© Totalflow Slide 37 NGC INSTALLATION
NGC MOUNTING METHODS
Pipe Stand
Wall
Shelf
Cold Weather Enclosure
Technical Conference
2006 Totalflow
2006 Totalflow
Technical Conference
PIPE STAND
Technical Conference
2006 Totalflow Wall mount with enclosure – Location Texas
Conroe
Technical Conference
2006 Totalflow Stealth Enclosure
Landfill
Landfill
CC6++ 7+
CC7+
6
Pipelines
Pipelines&& Gas
Power Gas
PowerPlant
Plant Distribution
Distribution
Integral
Integral
CC9+
9+ Flow
Flow
© Totalflow Slide 45
Dewpoint
Dewpoint Computer
Computer
High
Highend
end
Samplers
Samplers
NGC APPLICATIONS
Custody Transfer Measurement
Multi Tube Custody Transfer Measurement
Gas Sampler Replacement
City Gate Measurement and Control
Feed Forward Plant Balance
Ultrasonic Gas Metering
Plant Process Analysis and Control
LNG Re-gasification
© Copyright year ABB - -
Blending Applications
Custody Transfer Measurement
Continuous update of Btu, composition and density numbers for energy
calculations in the flow computer
“Real time” gas quality prevents end of the month energy / volume
recalculations
Identify gas composition that is not in specification
More accurate energy numbers for billing
Multi Tube Custody Transfer Measurement
Provide gas quality information from 1 to 3 flow meters (tubes).
Provide information for tube switching between multiple suppliers
Provide all measurement calculations for energy station
Gas Sampler Replacement
NGC 8206 size is almost the same size as a continuous gas sampler
“Real time” gas quality information eliminates end of month volume / energy
recalculation
Eliminates safety issues with sample bottle handling and transportation
Eliminates transportation fees and lab charges for bottle analysis
City Gate Measurement and Control
Provide gas utility with quality information from two different suppliers
“Real time” data allows best choice of gas supplier for utility customers
Interfaces with flow computer to automatically select supplier
“Real time” gas quality data for accurate accounting / daily nomination
Feed Forward Plant Balance
Provide compositional and heating value information for both sides of the plant
balance equation.
Provide data for fine tuning plant operations
Monitor quality of input gas from supplier
Ultrasonic Gas Metering
Monitor Btu, gas composition, WOBBE, and density of gas from re-gasification
plants
Good check of efficiency of plant processes
C9+ version (future) used to calculate hydrocarbon dew point of gas
Blending Applications
Provide continuous Btu and energy monitoring for blending or peak shaving
applications
Can monitor all gas streams, before and after blending interface
Provide control output to blend for desired energy level
Reduce maintenance by efficiently automating blending process
BTU Installation in Thailand,Australia & NZ
Bakersfield
Installations In Petronas Gas Malaysia
Gas Metering Skid – Therms Measurement Station
Solar Panel
Remote Comm../
Modbus
Radio, Modem, Satelite, etc.
A
L
123456 7 SCF
A
R
M
TOTALFLOW
BTU-8000
Modbus Link
TOTALFLOW
ABB
Modbus/PI
Sample Line
Process Gas
P DO/AO
Pressure RTD Probe Valve Control
Sample Probe UFM Gas Meter Sensor T
P
UFM Gas Meter Pressure
T
Sample Probe Sensor
RTD Probe
ABB Natural Gas Energy Metering System
Primary Meter BTU8000
(non-Totalflow) ABB Totalflow manufactures several
USM measurement devices which establish a
Orifice basis from which we can supply complete
energy packages.
Turbine Each metering system is designed around
using the BTU 8000, RTU or Low Powered
+
Flow Computer
Preconfigured systems allow simple, efficient
field installation and commissioning
Complete system can be solar powered
Each metering system easily integrates into
host systems supporting both fiscal metering
audit trail and SCADA requirements.
XFC or XRC
Flowcomputer or
Remote Controller
WinCCU,SCADAVision &
TF.Net Host Systems
Pakistan 4”Energy Metering Skid – BTU8000 & XRC
Pakistan 6”Energy Metering Skid – BTU8000 & XRC
Malaysia
The engineers' interface, the PCCU Setup Mode, give the user
almost unlimited versatility.
© Totalflow Slide 65
Service and Support
User Documentation
Training classes
User Manual
NGC 8200 Series Family
NGC with
NGC 8206 Flow computer NGC 8209
© Totalflow Slide 67
Mobile Unit
2006 Totalflow
Technical Conference
THANK YOU! QUESTIONS?
How to contact us:
Transmission
© Totalflow Slide 71
Distribution
Gas Orifice Chart System Replacement
Chart
Measurement System
Gas Accounting
ABB Totalflow Offerings
Remote battery powered flow
computers (FCU)
Remote battery powered RTU’s
Gas Chromatograph
Windows PC and Networked
Host Systems
Windows Configuration Software
Gas Industry Application Software
System Integration / Project Management
Specialized Customer Services
© Totalflow Slide 73
Training
Totalflow Flow Computer Metering Products
XFC
microFLO XRC + Modbus MV
- DIV2 XSeries Flow Computer
- DIV2 uFLO Flow Computer - DIV2 XSeries Remote Controller
- Integral Multivariable
- Integral Multivariable - External DIV1 Modbus Multivariable
- Battery, Charger
- Battery - Battery, Charger
- 2AI, 2DI/PI, 2DO
- Charger - 5AI, 4DI/2PI, 4DO
- 3 Comm Ports
- 2 Comm Ports - 3 Comm Ports
- Integral Comm Device
- Integral Comm Device - Integral Comm Device
- Extendable IO / Software
- Extendable IO / Software
- Gen Purpose Monitor/Control
- Gen Purpose Monitor/Control
XFC FP
PT TT
- DIV1 XSeries Flow Computer
© Totalflow Slide 74
- Integral Multivariable
- External Battery, Charger
- 1AI, 1DI/PI, 1DO XRC + Analog Transmitters
- 3 Comm Ports Same as any XRC
- Extendable IO / Software
- Gen Purpose Monitor/Control
X Series FCU / RTU Family
Multiple Wellhead Measurement / Controller Choices
XFC 6210 EX
With IMV multivariable
XRC Series RTU
With XMV Multivariable
And optional keypad
XFC 6400/6700 Series Flow Computer
Integrated multivariable transducer
(DP, P, T using RTD Temp element)
Low-cost single run or multi-tube design
Aluminum powder coated enclosure
CSA DIV 2 / ATEX ZONE 2
Gas Flow Calculations per AGA / ISO
Meets or exceeds API 21.1
Differential and Linear Meters Supported
3 Com Ports on Base Board (1 Local, 2 Remote)
Low cost communications kits
On-board I/O:
2 AI, 2 DI/PI, 2 DO
Battery & Charger Voltage
Extendable I/O and Communications TFIO Modules
3 TFIO DIN modules (6400 series) (8) AI
(4) AO
6 TFIO DIN modules (6700 series) (8) DI DO PI
Software capability (2) DO, (6) DI DO PI, (1) AO
IEC 61131 Languages for application specific math, (1) RS 232 or RS 485
alarming and logic (4) TC
(4) RTD
© Totalflow Slide 76
XRC 6400 / 6700 Series RTU
Designed for use with linear meters and remote multivariable
transmitters (XMV: DP, P, T)
Low-cost single run or multi-tube design
Aluminum powder coated enclosure
CSA DIV 2 / ATEX ZONE 2
Gas Flow Calculations per AGA / ISO
Meets or exceeds API 21.1
3 Com Ports on Base Board (1 Local, 2 Remote)
Low cost communications kits
On-board I/O:
5 AI, 4 DI/PI, 4 DO
Battery & Charger Voltage
Extendable I/O and Communications
3 TFIO DIN modules (6400 series)
6 TFIO DIN modules (6700 series)
Software capability Optional Keypad available on XFC or XRC
IEC 61131 Languages for application specific math, alarming
and logic
© Totalflow Slide 77
Protocol convertor
Control Rm
IS Barrier
RS485 MODBUS
PT
RTD
Pulse, PT, TT
Pulse, PT, TT
XRC.
© Totalflow Slide 80
PT
RTD
Safe Area
Totalflow Flow Computer -- XFC & XRC Products
6210EX FCU
© Totalflow Slide 83
Solar Panel
Remote Comm../
Modbus
Radio, Modem, Satelite, etc.
A
L
123456 7 SCF
A
R
M
TOTALFLOW
BTU-8000
Modbus Link
TOTALFLOW
ABB
Modbus/PI
Sample Line
Process Gas
P DO/AO
Pressure RTD Probe Valve Control
Sample Probe UFM Gas Meter Sensor T
© Totalflow Slide 91
P
UFM Gas Meter Pressure
T
Sample Probe Sensor
RTD Probe
ABB Natural Gas Energy Metering System
Primary Meter BTU8000
(non-Totalflow) ABB Totalflow manufactures several
USM measurement devices which establish a
Orifice basis from which we can supply complete
energy packages.
Turbine Each metering system is designed around
using the BTU 8000, RTU or Low Powered
+
Flow Computer
Preconfigured systems allow simple, efficient
field installation and commissioning
Complete system can be solar powered
Each metering system easily integrates into
host systems supporting both fiscal metering
audit trail and SCADA requirements.
© Totalflow Slide 92
XFC or XRC
Flowcomputer or
Remote Controller
WinCCU,SCADAVision &
TF.Net Host Systems
© Totalflow Slide 93 Pakistan 4”Energy Metering Skid – BTU8000 & XRC
© Totalflow Slide 94 Pakistan 6”Energy Metering Skid – BTU8000 & XRC
© Totalflow Slide 95
© Copyright year ABB - - LevelMaster Monitoring Tank Battery
TF.NET / Web Data Services – Browser Interface to ABB and other databases
Totalflow acquires data into data base, then provides it via Web Pages acessible by
Standard Browsers, provided as a Totalflow Service or can be installed on Customer
Intra / Internet facilities. Part of Leased Data Services.
Totalflow (WinCCU)
Central Collection Unit
Primarily for management of
Custody Transfer Data
Windows NT/2000
Network Capable
Functions
Communications - direct, radio,
modem, etc
Dual Database Archive
Long Term Audit Feature
Compliant with API 21.1
Reports - 14 Standard
Edit - Volume Adjustments compliant
with API 21.1
Alarm - Polled or Exception
Export - To Other Systems
Interactive User Interfaces to
Remote Equipment Data
Scheduler
Standard Applications
Application (slot)
number assigned to
the selected
application (object)
List of supplied objects
(applications)
TOTALFLOW Trend System
Line Graph and Tabular Screen Views
Trend any variable,totally flexible