0% found this document useful (0 votes)
116 views2 pages

Deep Sea Electronics PLC M840 Installation Instructions: Typical Connections

This document provides installation instructions and specifications for the M840 device from Deep Sea Electronics PLC. It notes that ignition must be utilized correctly to enable/disable the application program and store logs/parameters. Cables/wires must be installed as indicated to prevent water entry and interference coupling must be avoided. Unused interfaces must have protection plugs installed to maintain an IP67 rating. Fuses should be selected appropriately based on loads connected to device outputs. Dimensions, connectors, and spare parts are also specified.

Uploaded by

Dadi Sucahyono
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
116 views2 pages

Deep Sea Electronics PLC M840 Installation Instructions: Typical Connections

This document provides installation instructions and specifications for the M840 device from Deep Sea Electronics PLC. It notes that ignition must be utilized correctly to enable/disable the application program and store logs/parameters. Cables/wires must be installed as indicated to prevent water entry and interference coupling must be avoided. Unused interfaces must have protection plugs installed to maintain an IP67 rating. Fuses should be selected appropriately based on loads connected to device outputs. Dimensions, connectors, and spare parts are also specified.

Uploaded by

Dadi Sucahyono
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TYPICAL CONNECTIONS

DEEP SEA ELECTRONICS PLC 053-188 ISSUE 1

M840 Installation Instructions


These instructions are intended as a quick guide only. For complete instructions
and specifications, refer to DSE publication 057-248 DSEM840 Operator
Manual available from www.deepseaplc.com.

NOTE: Ignition (Pin A13) must be utilised correctly to enable / disable the
application program. This ensures that logs and other changed parameters are
stored when the Ignition is switched off.

NOTE: Cables / wires must be installed as indicated by the


manufacturer to prevent water entering the device. Part number of suitable
connectors are detailed in DSE publication 057-248 DSEM840 Operator
Manual available from www.deepseaplc.com.

NOTE: Interference coupling must be avoided by correctly handling


unused cable cores.

NOTE: To ensure IP67 rating the supplied M12 protection plugs must
be installed in both the USB and Ethernet interfaces when not in use.

NOTE: Software and associated Device Descriptors are available from


www.deepseaplc.com.

FUSING
Select fuses appropriately to protect the circuits connected to the device’s outputs.

Description Specification
DC Supply (Pin A7) 3 A Max (to supply M840 along with no Deep Sea Electronics PLC Deep Sea Electronics Inc.
Supplies M840 and High Current output loads on Pins A2, A3, A4, A5).
Tel: +44 (0)1723 890099 Tel: +1 (815) 316-8706
Outputs 10 A Max (to supply M840 with outputs fully
Fuse as Required by Output Loads loaded on Pins A2, A3, A4, A5).
Fax: +44 (0)1723 893303 Fax: +1 (815) 316-8708
(Pins A2, A3, A4, A5) Email: [email protected] Email: [email protected]
Ignition (15) (Pin A13) 1 A Max Web: www.deepseaplc.com Web: www.deepseausa.com
DIMENSIONS DIMENSIONS DIAGRAM
Description Specification
Overall Dimensions (Height x Width x Depth) 208 mm x 131 mm x 56 mm
(8.18 ” x 5.14 ” x 2.19 ”)
Mounting Type 4 x mounting bolts or RAM
mount.
Overall Weight <1 kg
(2.2 lb)
Fascia Mounting Holes Suitable for M5 bolts
(0.3 “ holes)
Fascia Mounting Hole Centres See Diagram
Panel Cut-Out 163 mm x 98 mm
(6.42 ” x 3.86 ”)
Fascia Mounting Bolt Material Recommendation Steel or Stainless Steel
Fascia Mounting Bolt Tightening Torque to 1.2 Nm Maximum
prevent distortion of the sealing gasket and (0.9 ft. lb Maximum)
subsequent seal failure / mechanical damage to
the controller.
RAM Mounting Holes Suitable for M5 bolts
(0.3 “ holes)
RAM Mounting Hole Centres 30 mm x 38 mm
(1.19 “ x 1.50 “)
RAM Mounting Bolt Material Recommendation Steel or Stainless Steel
RAM Mounting Bolt Tightening Torque 4 Nm Maximum
(2.95 ft. lb Maximum)

CONNECTORS, HARNESSES AND SPARE PARTS


Description DSE Manufacturer Details
Part
M840 Connector 007-850 DT16-18SA-K004 TE /
Deutsch
Connector Pin Crimp N/A 0462-201-16 TE
(0.5 mm2 to 1.0 mm2)
Connector Pin Crimp 0462-209-16 TE
(2 mm2)
M840 Connector Harness Kit 016-168 N/A DSE
M12 to Ethernet Cable 016-160 VS-M12MS-IP20-93R-L1/2 Phoenix
M12 to USB Cable 016-161 N/A DSE
Belden 9841 (CAN Cable) 016-030 9841 Belden
Panel Mounting Sealing 020-602 N/A DSE
Gasket