Protechtps: Product Change Notification 06947
Protechtps: Product Change Notification 06947
Change Notification 06947
(1/2018)
ProTechTPS
Overview
On January 30, 2018, Woodward will be releasing new “preferred” ProTechTPS models and a
new Field Software Conversion kit. The new ProTechTPS models include the same functionality
as the older ProTechTPS models but include many product improvements and enhancements
requested by product line users throughout the past years. After January 30, 2018, Woodward
recommends that customers who are purchasing ProTechTPS units for use in new applications
order part numbers from the “preferred” part number list only.
This ProTechTPS software update provides enhanced math/computational functionality and adds
over 100 logic blocks for use when programming this safety logic solver for a specific application.
The new Field Software Conversion kit can be purchased and used to upgrade/convert older
ProTechTPS models in the field to the new “preferred” ProTechTPS models by simply
uploading/installing the latest software program. Refer to below description of changes for a list of
the improvements and enhancements available. Refer to product manuals 35059v1 & 35059v2
for detailed product information on these new “preferred” ProTechTPS models.
Description of Changes
The new ProTechTPS software program is based on the older ProTechTPS software program
and includes the below listed improvements/enhancements.
New features
The following new computational blocks were added:
1. MULTIPLY block. Provides the product of all configured inputs. Up to five inputs per block.
Quantity 5.
2. DIVIDE block. Performs a divide function on the two inputs. Quantity 5.
3. ADD block. Provides the sum of all configured inputs. Up to five inputs per block. Quantity 5.
4. NEGATE block. Supports subtraction functionality by providing the negative value of the input.
Quantity 10.
Added the following new support blocks:
1. CURVE block (polygon): A 2-dimensional lookup based on a single, configured analog input. Up
to six breakpoints (coordinate pairs) can be defined. Values between breakpoints are
interpolated. Values beyond table-defined min or max are limited - equal to first or last point,
respectively; Quantity 2.
2. SWITCH block: Outputs one of two analog input values based on the status of the control input.
Example usage: selecting a default value for a calculation if an analog input is failed; Quantity
10.
3. CONSTANT block: Allows definition of a fixed analog value to be used in conjunction with the
math/analog blocks; Quantity 40.
4. ANALOG UNIT DELAY block: Loop breaking block for analog signals, to define execution order.
Asserts a unit delay; Quantity 10.
5. COUNTER block: Provides a count indication as well as a comparison output which indicates
when a count threshold is exceeded; Quantity 10.
6. PEAK HOLD block: Captures and holds both maximum and minimum signal values; Quantity 10.
7. PULSE DETECT block: Monitors an analog signal and is used to detect a sudden rise in value
followed by a drop. The output indicates a pulse was detected; Quantity 5.
8. EVENT FILTER block: Provides an indication that an excessive number of events have occurred
within the defined window of time. Typically used in conjunction with the PULSE DETECT;
Quantity 5.
Product Change Notification 06947 p.2
Compatibility Notes and Table
Field Software Conversion kit 8929-037 is compatible with and can be used to convert most older
ProTechTPS models to the newer models listed below. See table below for compatibility
information.
Description Part Numbers that Can Be Converted
ProTechTPS – Bulkhead Mount, HV/LV, Ind. Relays 8237‐1248 Rev D or Newer or 8237-1602
ProTechTPS – Bulkhead Mount, HV/HV, Ind. Relays 8237‐1249 Rev D or Newer or 8237-1603
ProTechTPS – Bulkhead Mount, HV/LV, Voted Relays 8237‐1250 Rev D or Newer or 8237-1604
ProTechTPS – Bulkhead Mount, HV/HV, Voted Relays 8237‐1251 Rev D or Newer or 8237-1605
ProTechTPS – Panel Mount, HV/LV, Ind. Relays 8237‐1371 Rev D or Newer or 8237-1606
ProTechTPS – Panel Mount, HV/HV, Ind. Relays 8237‐1372 Rev D or Newer or 8237-1607
ProTechTPS – Panel Mount, HV/LV, Voted Relays 8237‐1373 Rev D or Newer or 8237-1608
ProTechTPS – Panel Mount, HV/HV, Voted Relays 8237‐1374 Rev D or Newer or 8237-1609
ProTechTPS – Field Software Conversion Kit 8929-037
Only ProTechTPS Service Tool (9927-1684 Rev. F or newer) is compatible with both new and old
ProTechTPS models. Note that the latest revision of this service tool can be obtained/ downloaded
from Woodward’s website
Configuration files from older ProTechTPS models can be loaded into new ProTechTPS models
using the ProTechTPS service tool. However, configuration files from new ProTechTPS models
cannot be loaded into older ProTechTPS models.
Product Change Notification 06947 p.4
Preferred Model Numbers
The following table shows the new/improved “preferred” ProTechTPS part numbers:
Customer Action
1. Customers who are currently using any ProTechTPS model and do not require any of the above listed
changes/improvements should take no action. Woodward is committed to supporting the listed “non-
preferred” models for a period of 20 years after inactivation. Refer to the related product support plan
for these models.
2. After January 30, 2018, Woodward recommends that customers who are purchasing ProTechTPS
units for use in new applications order part numbers from the “preferred” part number list only.
3. After January 30, 2018, customers who currently own an older ProTechTPS model and wish to
have/utilize one or more of the above listed changes/improvements can send their old ProTechTPS
model into Woodward Colorado, USA for a conversion to a new model. Optionally, they can purchase
Field Software Conversion Kit 8929-037 and schedule a field conversion by an authorized Woodward
field service engineer. Please contact your Woodward representative to schedule model conversions.
The following are trademarks of Woodward, Inc.:
MicroNet
ProTech
The following are trademarks of their respective companies:
Modbus (Schneider Automation Inc.)