31/1/22 17:16 Results
731 - RCS LEVEL 2
JORDAN RAUL GALA TAIPE
Date / Time Student Score Passing Score Result
January 31, 2022
84 80 Pass
5:15 pm
731 - RCS LEVEL 2
Correct Student Points
# Question Result
Answer Answer Awarded
The vents The vents
What should be recorded before starting a test or current current
1 Correct 10
calibration on the new RCS? configuration configuration
file number file number
If a parameter is in outlined text, which of the Options B & (a) It can be
2 Incorrect 0
following is true: C adjusted.
What testing must be done when the
3 Hipot Hipot Correct 10
CPU/UIM/SPO2 stack is replaced?
Should tubing, gaskets and O-rings be automatically
4 No No Correct 10
replaced during a 1-year PM?
No – Inspect No – Inspect
Should tubing, gaskets and O-rings be automatically
5 and replace and replace Correct 10
replaced during a 4-year PM?
as necessary. as necessary.
Smart Smart
6 What is SPM an abbreviation for? Pneumatic Pneumatic Correct 10
Module Module
What is the anti-vibration compound applied to each
7 Vibratite Vibratite Correct 10
screw called:
Clean and re- Clean and re-
What must be done to screws before they can be apply anti- apply anti-
8 Correct 10
reused in a service process? vibration vibration
compound compound
What is the recommended Service Kit to replace in
9 712-0731-14 712-0731-14 Correct 10
case of a ventilator alarm category: CPU Failure?
What is the recommended Service Kit to replace in
10 case of a ventilator alarm category: Exhalation 712-0731-02 712-0731-02 Correct 10
System Fault/Failure?
What is the recommended Service Kit to replace in
11 712-0731-02 712-0731-02 Correct 10
case of a Service Code 2011?
What is the recommended Service Kit to replace in
12 712-0731-08 712-0731-08 Correct 10
case of a Service Code 1475?
Voltage = Voltage =
5.00kV, 5.00kV,
Current = Current =
13 What settings should used for the HiPot test? Correct 10
50uA, 50uA,
Duration = Duration =
0.5 sec 0.5 sec
What torque settings should the Oxygen Inlet fitting
14 19 In-Lbs 19 In-Lbs Correct 10
be tightened down to?
All of the All of the
15 Where can a high pressure O2 leak originate from? Correct 10
above. above.
16 What does the ventilator use to trigger Assisted Patient Patient Correct 10
breaths? Airway Airway
https://elearning.zoll.com/Files/Private/Courses/f7ebfa2f-ea6f-456f-b789-f3c353babb34/sx2zv31g/quiz_content/report.html 1/2
31/1/22 17:16 Results
Pressure Pressure
YES, but the
older RCS
Can Version 4.16 vents be tested/calibrated with the
17 will no longer NO Incorrect 0
new RCS?
be able to
read the vent.
What special compound to control liquid ingress
18 should be used for kits 712-0731-07, 712-0731- and RTV Sealant RTV Sealant Correct 10
712-0731-14?
Yes but Yes but
needs to be needs to be
19 Can screws with Vibratite be reused? cleaned and cleaned and Correct 10
Vibratite re- Vibratite re-
applied. applied.
20 What is the 712-0731-30 kit? O2 Valve Kit O2 Valve Kit Correct 10
Technical
What document besides the Service manual may Operators
21 Service Incorrect 0
include additional service kits? Manual
Bulletins
Can service kits on a Membrane Panel vent be
22 No Yes Incorrect 0
directly replaced on a Buttonboard vent?
How many USB Serial Converters must be present
23 in Device manager for the ventilator to properly 2 2 Correct 10
communicate with the RCS?
If 1 or 0(Zero) USB Serial converters are present,
24 CPU Board CPU Board Correct 10
what should be replaced?
What torque setting is used to assemble the CPU
25 4.5 in-lbs 4.5 in-lbs Correct 10
board to the UIM Bracket?