Rcbos Ex9Nl-N 3P+N, 6 Ka

The document describes residual current circuit breakers (RCBOs) with overload protection for 3-phase applications up to 6 kA. The RCBOs combine residual current protection and circuit breaker functions. They are available in AC and A types with 30mA and 300mA residual current ratings and B or C tripping characteristics. The RCBOs provide protection from direct and indirect contact with live parts for applications from -25°C to +40°C.

Uploaded by

Vlad Nistor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views6 pages

Rcbos Ex9Nl-N 3P+N, 6 Ka

The document describes residual current circuit breakers (RCBOs) with overload protection for 3-phase applications up to 6 kA. The RCBOs combine residual current protection and circuit breaker functions. They are available in AC and A types with 30mA and 300mA residual current ratings and B or C tripping characteristics. The RCBOs provide protection from direct and indirect contact with live parts for applications from -25°C to +40°C.

Uploaded by

Vlad Nistor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

RCBOs Ex9NL-N 3P+N, 6 kA

■ Residual Current circuit Breakers


with Overload protection according
to IEC / EN 61009-1

■ Rated breaking capacity Icn 6 kA

■ 3+N-pole version

■ Rated residual current 30, 300 mA

■ Rated currents up to 40 A

■ B and C tripping characteristics


of installed circuit breaker

■ AC and A type of RCD

■ 4-module width

■ Suitable for applications from -25 to +40°C

Ex9NL residual current circuit breakers are suitable for domestic as well as industrial applications. They are
based on combination of residual current device with permanent magnet principle and circuit breaker with
thermal overload release and magnetic short circuit current release. It brings the advantage of voltage inde-
pendent function of the residual current device. Adequate voltage is only necessary when testing the RCBO
with the T test button. Magnetic RCBOs should be tested regularly. Recommend is to test it every 6 months
in fair enviroment and every month in heavy condition.

Type Key

Ex9 NL -N 3PN C 40A A 30mA

Rated Tripping Sensitivity Rated


Product Rated
Product breaking Poles characteristic to type residual
family current
capacity of MCB of current current

B _: AC 30 mA
Ex9 NL: RCBO -N: 6 kA 3P+N 6 — 40 A
C A: A 300 mA

Certification marks

1
RCBOs Ex9NL-N 3P+N, 6 kA
AC type, characteristic B

• AC type of residual current circuit breaker sensitive on residual AC current


• B characteristic of installed circuit breaker
• Without time delay
• Suitable for protection of people in case of direct and indirect contact with live parts and exposed conductive part during a fault,
respectively

Rated Rated MCB Article Type Packing


current residual tripping No.
current char.
10A 30mA B 111496 Ex9NL-N 3P+N B10 30mA 1/45
13A 30mA B 111497 Ex9NL-N 3P+N B13 30mA 1/45
16A 30mA B 111498 Ex9NL-N 3P+N B16 30mA 1/45
20A 30mA B 111499 Ex9NL-N 3P+N B20 30mA 1/45
25A 30mA B 111500 Ex9NL-N 3P+N B25 30mA 1/45
32A 30mA B 111501 Ex9NL-N 3P+N B32 30mA 1/45
40A 30mA B 111502 Ex9NL-N 3P+N B40 30mA 1/45

10A 300mA B 111504 Ex9NL-N 3P+N B10 300mA 1/45
13A 300mA B 111505 Ex9NL-N 3P+N B13 300mA 1/45
16A 300mA B 111506 Ex9NL-N 3P+N B16 300mA 1/45
20A 300mA B 111507 Ex9NL-N 3P+N B20 300mA 1/45
25A 300mA B 111508 Ex9NL-N 3P+N B25 300mA 1/45
32A 300mA B 111509 Ex9NL-N 3P+N B32 300mA 1/45
40A 300mA B 111510 Ex9NL-N 3P+N B40 300mA 1/45

AC type, characteristic C

• AC type of residual current circuit breaker sensitive on residual AC current


• C characteristic of installed circuit breaker
• Without time delay
• Suitable for protection of people in case of direct and indirect contact with live parts and exposed conductive part during a fault,
respectively

Rated Rated MCB Article Type Packing


current residual tripping No.
current char.
6A 30mA C 111511 Ex9NL-N 3P+N C6 30mA 1/45
10A 30mA C 111512 Ex9NL-N 3P+N C10 30mA 1/45
13A 30mA C 111513 Ex9NL-N 3P+N C13 30mA 1/45
16A 30mA C 111514 Ex9NL-N 3P+N C16 30mA 1/45
20A 30mA C 111515 Ex9NL-N 3P+N C20 30mA 1/45
25A 30mA C 111516 Ex9NL-N 3P+N C25 30mA 1/45
32A 30mA C 111517 Ex9NL-N 3P+N C32 30mA 1/45
40A 30mA C 111518 Ex9NL-N 3P+N C40 30mA 1/45

6A 300mA C 111519 Ex9NL-N 3P+N C6 300mA 1/45
10A 300mA C 111520 Ex9NL-N 3P+N C10 300mA 1/45
13A 300mA C 111521 Ex9NL-N 3P+N C13 300mA 1/45
16A 300mA C 111522 Ex9NL-N 3P+N C16 300mA 1/45
20A 300mA C 111523 Ex9NL-N 3P+N C20 300mA 1/45
25A 300mA C 111524 Ex9NL-N 3P+N C25 300mA 1/45
32A 300mA C 111525 Ex9NL-N 3P+N C32 300mA 1/45
40A 300mA C 111526 Ex9NL-N 3P+N C40 300mA 1/45

2
RCBOs Ex9NL-N 3P+N, 6 kA
A type, characteristic B

• A type of residual current circuit breaker sensitive on residual AC and pulsating DC current
• B characteristic of installed circuit breaker
• Without time delay
• Suitable for protection of people in case of direct and indirect contact with live parts and exposed conductive part during a fault,
respectively

Rated Rated MCB Article Type Packing


current residual tripping No.
current char.
10A 30mA B 111528 Ex9NL-N 3P+N B10 A 30mA 1/45
13A 30mA B 111529 Ex9NL-N 3P+N B13 A 30mA 1/45
16A 30mA B 111530 Ex9NL-N 3P+N B16 A 30mA 1/45
20A 30mA B 111531 Ex9NL-N 3P+N B20 A 30mA 1/45
25A 30mA B 111532 Ex9NL-N 3P+N B25 A 30mA 1/45
32A 30mA B 111533 Ex9NL-N 3P+N B32 A 30mA 1/45
40A 30mA B 111534 Ex9NL-N 3P+N B40 A 30mA 1/45

10A 300mA B 111536 Ex9NL-N 3P+N B10 A 300mA 1/45
13A 300mA B 111537 Ex9NL-N 3P+N B13 A 300mA 1/45
16A 300mA B 111538 Ex9NL-N 3P+N B16 A 300mA 1/45
20A 300mA B 111539 Ex9NL-N 3P+N B20 A 300mA 1/45
25A 300mA B 111540 Ex9NL-N 3P+N B25 A 300mA 1/45
32A 300mA B 111541 Ex9NL-N 3P+N B32 A 300mA 1/45
40A 300mA B 111542 Ex9NL-N 3P+N B40 A 300mA 1/45

A type, characteristic C

• A type of residual current circuit breaker sensitive on residual AC and pulsating DC current
• C characteristic of installed circuit breaker
• Without time delay
• Suitable for protection of people in case of direct and indirect contact with live parts and exposed conductive part during a fault,
respectively

Rated Rated MCB Article Type Packing


current residual tripping No.
current char.
6A 30mA C 111543 Ex9NL-N 3P+N C6 A 30mA 1/45
10A 30mA C 111544 Ex9NL-N 3P+N C10 A 30mA 1/45
13A 30mA C 111545 Ex9NL-N 3P+N C13 A 30mA 1/45
16A 30mA C 111546 Ex9NL-N 3P+N C16 A 30mA 1/45
20A 30mA C 111547 Ex9NL-N 3P+N C20 A 30mA 1/45
25A 30mA C 111548 Ex9NL-N 3P+N C25 A 30mA 1/45
32A 30mA C 111549 Ex9NL-N 3P+N C32 A 30mA 1/45
40A 30mA C 111550 Ex9NL-N 3P+N C40 A 30mA 1/45

6A 300mA C 111551 Ex9NL-N 3P+N C6 A 300mA 1/45
10A 300mA C 111552 Ex9NL-N 3P+N C10 A 300mA 1/45
13A 300mA C 111553 Ex9NL-N 3P+N C13 A 300mA 1/45
16A 300mA C 111554 Ex9NL-N 3P+N C16 A 300mA 1/45
20A 300mA C 111555 Ex9NL-N 3P+N C20 A 300mA 1/45
25A 300mA C 111556 Ex9NL-N 3P+N C25 A 300mA 1/45
32A 300mA C 111557 Ex9NL-N 3P+N C32 A 300mA 1/45
40A 300mA C 111558 Ex9NL-N 3P+N C40 A 300mA 1/45

3
Technical Data Ex9NL-N 3P+N
Residual Current Breakers with Overload protection Ex9NL-N 3P+N, 6 kA

General parameters
Combination of MCB and RCCB in one case - saves 50 % space in comparison to combination of stand-alone MCB and RCCB
Tripping characteristics of installed circuit breaker B and C
AC and A type of residual current device
3+N-pole version
Suitable for household as well as industrial applications
Permanent magnet priciple of residual current device - Voltage independent tripping function
Recommend is to test device every 6 months in fair enviroment and every month in heavy condition.
Signaling of contacts status

Electrical parameters
Tested according to IEC/EN 61009-1
Rated op. voltage Ue 400 V AC
Min. voltage for RCD function voltage independent
Voltage range of the test button T 340 — 440 V AC
Rated frequency 50/60 Hz
Rated breaking capacity Icn 6 kA
Rated current 6 — 40 A
Rated residual current 30, 300 mA
Sensitivity to residual current AC type - AC residual current
A type - residual AC and pulsating DC current
Time characteristic of RCD undelayed type
Tripping characteristics of MCB B, C
Rated impulse withstand voltage Uimp 4 kV
Rated insulation voltage Ui 500 V
Surge current proof 3000 A
Mechanical service life 10 000 operation cycles
Electrical service life 2 000 operation cycles
Selectivity class 3
Back-up fuse/breaker max. 125 A gG
Line voltage connection arbitrary above or below

Mechanical parameters
Device width 72 mm
Device height 82 mm including rail clip
Frame size 45 mm
Mounting easy fastening onto 35 mm device rail (DIN)
Degree of protection IP20
Terminals combined lift + open mouthed
Terminal capacity 1 — 16 mm2
Fastening torque of terminals 2Nm
Busbar thickness 0.8 — 1.5 mm
Ambient temperature -25 — +40 °C
Altitude ≤ 2000 m
Relative humidity ≤ 95 %
Resistance to humidity and heat class 2
Pollution degree 2
Installation class III
Weight 0.432 kg

4
Technical Data Ex9NL-N 3P+N
Residual Current Breakers with Overload protection Ex9NL-N 3P+N, 6 kA
L-N Ex9NL-N
Dimensions
RCBO
Proudový chránič s nadpr. ochr.
Prúdový chránič s nadpr. ochr.
1 4
Wyłącznik nadprąd. z mod. różnicowoprąd.
Intrerupator diferential/automate

34.5

45
86
FI/LS-Schalter
Interrupteur differential
ДAB
Автоматичен прекьсвач с вградена ДТЗ
60.7
Kombinovana diferencijalna zaštitna sklopka 72
77.5

L-N Ex9NL-N UT


Wiring diagram 

I










6









Tripping characteristics of MCB 

              **O

Characteristic B Characteristic C
UT UT
L-N 

Ex9NL-N 

6

I I
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
              **O               **O

UT

Tripping characteristics of RCD


 UT
 
I 
 I
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 **O 
              
              **O

UT


I





 5





Technical Data Ex9NL-N 3P+N
Residual Current Breakers with Overload protection Ex9NL-N 3P+N, 6 kA

Dependence of Tripping Characteristics on Ambient Temperature


T In (T) [A]
[°C]
6A 10 A 13 A 16 A 20 A 25 A 32 A 40 A
-10 7.2 12 15.6 19.2 24 30 38.4 48
0 6.9 11.5 14.95 18.4 23 28.75 36.8 46
10 6.6 11 14.3 17.6 22 27.5 35.2 44
20 6.3 10.5 13.65 16.8 21 26.25 33.6 42
30 6 10 13 16 20 25 32 40
40 5.7 9.5 12.35 15.2 19 23.75 30.4 38
50 5.4 9 11.7 14.4 18 22.5 28.8 36
60 5.1 8.5 11.05 13.6 17 21.25 27.2 34

Power loss
In [A] 6A 10 A 13 A 16 A 20 A 25 A 32 A 40 A
P [W] 2.8 5.3 5.3 8.4 6.9 10.7 14.6 17.8