Chilled Water Fan Coil Unit: Model:HFWA CFM 300 1400
Chilled Water Fan Coil Unit: Model:HFWA CFM 300 1400
Chilled Water Fan Coil Unit: Model:HFWA CFM 300 1400
Model:HFWA
CFM 300~1400
The Best Choice for Comfort
=Reliability
Trane’s history of innovation and
technology leadership led to quality
products making Trane a leader in the
air conditioning markets worldwide.
Trane’s commitment to customer’s
needs for quality, efficiency and
reliability is evident from the largest
chiller to smallest fan coil.
H F W A 03 A N H 1 N A F B
1 2 3 4 5,6 7 8 9 10 11 12 13 14
DIGIT 1 - Position DIGIT 9 - Motor Type F = Long Galvanized Steel / 6mm Non-Flammable
H = Horizontal N = Normal Duty Without Temperature Cutout- BS476, PART7 Insulation
standard G = STD. SUS / 6mm Non-Flammable BS476, PART7
DIGIT 2 - Unit Type M = Normal Duty With Temperature Cutout Insulation
F = Fan Coil H = High Static Without Temperature Cutout H = Long SUS / 6mm Non-Flammable BS476, PART7
G = High Static With Temperature Cutout Insulation
DIGIT 3 - Casing I = Normal Duty Without Temperature Cutout/With Ball I = STD. Galvanized Steel / 10mm PE Insulation
W = Exposed (with powder casing) Bearing J = Long Galvanized Steel / 10mm PE Insulation
J = Normal Duty With Temperature Cutout/With Ball K = STD. SUS / 10mm PE Insulation
DIGIT 4 - Development Sequence Bearing L = Long SUS / 10mm PE Insulation
A = First E = High Static Without Temperature Cutout/With Ball M = STD. Galvanized Steel / 15mm PE Insulation
Bearing O = Long Galvanized Steel / 15mm PE Insulation
DIGIT 5.6 - Size / Nominal CFM F = High Static With Temperature Cutout/With Ball P = STD. Galvanized Steel / 9mm Non-Flammable
03 = 300 CFM Bearing BS476, Part7 Insulation
04 = 400 CFM S = Special Q = Long Galvanized Steel / 9mm Non-Flammable
06 = 600 CFM BS476, Part7 Insulation
08 = 800 CFM DIGIT 10 - Voltage/Hertz/Phase R = STD. SUS / 15mm PE Insulation
10 = 1000 CFM 1 = 220-240 / 50 / 1 T = Long SUS / 15mm PE Insulation
12 = 1200 CFM 2 = 220-240 / 60 / 1 U = STD. Galvanized Steel / 15mm Non-Flammable
14 = 1400 CFM 5 = 115 / 60 / 1 BS476, Part7 Insulation
S = Special V = Long Galvanized Steel / 15mm Non-Flammable
DIGIT 7 - Coil Row, Connection Side BS476, Part7 Insulation
A = 2 Row Cooling, Right Hand DIGIT 11 - Control Valve Package S = Special
B = 2 Row Cooling, Left Hand N = Standard Piping / Without Valve Package
C = 3 Row Cooling, Right Hand B = 2 Pipe System / With Single 2-Way 2 Position DIGIT 13 - Plenum / Filters
D = 3 Row Cooling, Left Hand Valve / Without Thermostat A = With Return Plenum / 4mm P.P Nylon Filter
E = 4 Row Cooling, Right Hand C = 2 Pipe System / With Single 2-Way 2 Position B = With Return Plenum / 12mm Aluminum Media
F = 4 Row Cooling, Left Hand Valve / With Cool Thermostat C = With Return Plenum / 12mm Foam Media
G = 2 Row Cooling, 1 Row Heating, Right Hand D = 2 Pipe System / With Single 2-Way 2 Position D = With Return Plenum / 20mm Aluminum Media
H = 2 Row Cooling, 1 Row Heating, Left Hand Valve / With Cool/Heat Thermostat E = With Return Plenum / 20mm Foam Media
J = 3 Row Cooling, 1 Row Heating, Right Hand E = 2 Pipe System / With Single 3-Way 2 Position F = With Return Plenum / No Filter
K = 3 Row Cooling, 1 Row Heating, Left Hand Valve / Without Thermostat G = With Return Plenum / 25mm Aluminum Media
S = Special F = 2 Pipe System / With Single 3-Way 2 Position I = With Return Plenum / 20mm P.P. Nylon Filter
Valve / With Cool Thermostat K = With Return Plenum / 12mm Non-Woven
DIGIT 8 - Electric Heat 115V / 220V (240V) G = 2 Pipe System / With Single 3-Way 2 Position L = With Return Plenum / 20mm Non-Woven
N = None Valve / With Cool/Heat Thermostat P = With Return Plenum / 25mm Foam Media
A = 1.0 kW(1.2 kW) Heater (Size 03~14) H = 4 Pipe System / With 2 Sets 2-Way 2 Position S = Special
B = 1.5 kW(1.8 kW) Heater (Size 04~14) Valve / Without Thermostat
C = 2.0 kW(2.4 kW) Heater (Size 06~14) I = 4 Pipe System / With 2 Sets 2-Way 2 Position DIGIT 14 - Design Sequence
D = 2.5 kW(3.0 kW) Heater (Size 08~14) Valve / With Cool/Heat Thermostat B = Second Change (Export)
E = 3.0 kW(3.6 kW) Heater (Size 08~14)
F = 3.5 kW(4.2 kW) Heater (Size 10~14) DIGIT 12 - Drain Pan Note:
G = 4.0 kW(4.8 kW) Heater (Size 12~14) A = STD. Galvanized Steel / 5mm PE Insulation 1. HFWA will not support sweat connection for
S = Special B = Long Galvanized Steel / 5mm PE Insulation standard piping.
C = STD. SUS/5mm PE Insulation 2. None-flammable PU insulation meet the regulation
D = Long SUS/5mm PE Insulation of BS476 part7 class1, Heater option meet BS476
E = STD. Galvanized Steel / 6mm Non-Flammable part6 class O.
BS476, PART7 Insulation
3 HFWA-PRC001-EN
Performance Data
Note :
1. Dimensions in mm.
2. Right hand coil connection shown.
3. Wiring connection same side as coil and drain connections.
4. Wiring controls and junction box not supplied by Trane.
5 HFWA-PRC001-EN
Sound Power Level Connection / Piping
Wiring Diagram
Note:
1.Dimension in mm
2. 25.4 mm=1 in.
7 HFWA-PRC001-EN
The Trane Fan Coil...
...Invented by Trane
...Perfected by Trane
Since 1885, Trane has been at the Over 60 years ago Trane produced the first
technological forefront of air conditioning. fan coil unit and in so doing created a
The company's pioneering spirit, product which is now built worldwide. The
commitment to research and pursuit of universal acceptance of this product has
quality have made it a world leader in the prompted Trane to focus the same
manufacture of water chillers. engineering experience to the fan coil as
given to the refrigeration products.
FM38631
ISO 9001 Qualified factory - Trane Taiwan
Since The Trane Company has a policy of continuous product improvement, it reserves the right to change design and
An American-Standard Company specifications without notice.