I3070software Installation
I3070software Installation
Software Installation
Guide
Notices
© Keysight Technologies 2021 Technology Licenses Safety Notices
No part of this manual may be The hardware and/or software
reproduced in any form or by any described in this document are
means (including electronic storage furnished under a license and may be
and retrieval or translation into a used or copied only in accordance with A WARNING notice denotes a hazard.
foreign language) without prior the terms of such license. It calls attention to an operating
agreement and written consent from procedure, practice, or the like that, if
Keysight Technologies as governed by U.S. Government Rights not correctly performed or adhered to,
United States and international could result in personal injury or death.
copyright laws. The Software is "commercial computer Do not proceed beyond a WARNING
software," as defined by Federal notice until the indicated conditions are
Manual Part Number Acquisition Regulation ("FAR") 2.101. fully understood and met.
Pursuant to FAR 12.212 and 27.405-3
E9901-96022 and Department of Defense FAR
Supplement ("DFARS") 227.7202, the
Edition U.S. government acquires commercial A CAUTION notice denotes a hazard.
Edition 1, August 2021 computer software under the same It calls attention to an operating
Printed in Malaysia terms by which the software is procedure, practice, or the like that, if
customarily provided to the public. not correctly performed or adhered to,
Published by: Accordingly, Keysight provides the could result in damage to the product
Keysight Technologies Software to U.S. government or loss of important data. Do not
1400 Fountaingrove Parkway customers under its standard proceed beyond a CAUTION notice until
Santa Rosa, CA 95403-1738 commercial license, which is embodied the indicated conditions are fully
United States in its End User License Agreement understood and met.
(EULA), a copy of which can be found at
Warranty http://www.keysight.com/find/sweula.
THE MATERIAL CONTAINED IN THIS The license set forth in the EULA
DOCUMENT IS PROVIDED "AS IS," represents the exclusive authority by
AND IS SUBJECT TO BEING which the U.S. government may use,
CHANGED, WITHOUT NOTICE, IN modify, distribute, or disclose the
FUTURE EDITIONS. FURTHER, TO THE Software. The EULA and the license set
MAXIMUM EXTENT PERMITTED BY forth therein, does not require or
APPLICABLE LAW, KEYSIGHT permit, among other things, that
DISCLAIMS ALL WARRANTIES, EITHER Keysight: (1) furnish technical
EXPRESS OR IMPLIED WITH REGARD information related to commercial
TO THIS MANUAL AND ANY computer software or commercial
INFORMATION CONTAINED HEREIN, computer software documentation that
INCLUDING BUT NOT LIMITED TO THE is not customarily provided to the
IMPLIED WARRANTIES OF public; or (2) relinquish to, or otherwise
MERCHANTABILITY AND FITNESS FOR provide, the government rights in
A PARTICULAR PURPOSE. KEYSIGHT excess of these rights customarily
SHALL NOT BE LIABLE FOR ERRORS provided to the public to use, modify,
OR FOR INCIDENTAL OR reproduce, release, perform, display, or
CONSEQUENTIAL DAMAGES IN disclose commercial computer software
CONNECTION WITH THE or commercial computer software
FURNISHING, USE, OR documentation. No additional
PERFORMANCE OF THIS DOCUMENT government requirements beyond
OR ANY INFORMATION CONTAINED those set forth in the EULA shall apply,
HEREIN. SHOULD KEYSIGHT AND THE except to the extent that those terms,
USER HAVE A SEPARATE WRITTEN rights, or licenses are explicitly required
AGREEMENT WITH WARRANTY from all providers of commercial
TERMS COVERING THE MATERIAL IN computer software pursuant to the FAR
THIS DOCUMENT THAT CONFLICT and the DFARS and are set forth
WITH THESE TERMS, THE WARRANTY specifically in writing elsewhere in the
TERMS IN THE SEPARATE EULA. Keysight shall be under no
AGREEMENT WILL CONTROL. obligation to update, revise or
otherwise modify the Software.
Keysight i3070 In-Circuit Test Software
Software Installation Guide
Preparation 4
Installing the i3070 Software 7
Installing Software Licenses 13
Other Tasks 19
Troubleshooting Software Installation 22
This guide explains how to install the Keysight i3070 In-Circuit Test software
release 10.20p. This software release can be used for:
• Upgrading i3070 systems with software release 10.xxp.
• Upgrading i3070 systems with software release 09.xxp.
• First-time installation on new testhead controllers or test development
workstations running Windows 10 (64-bit).
In case of difficulty...
To contact Keysight technical support, go to www.keysight.com/find/contactus.
Preparation
1 Ensure that the PC meets the System requirements on page 5.
2 Make a complete system backup before installing the software.
3 If you are upgrading a system:
a At least back up the critical files listed in Table 2 on page 6, if you are unable
to do a full backup.
b Remove the previous releases of the i3070 software as described in
Uninstalling the i3070 In-Circuit Test Software on page 23.
4 Redeem your software licenses following the instructions in your Software
Entitlement Certificate.
Then install the i3070 In-Circuit Test software as described in Installing the i3070
Software.
Specifications
Processor Recommended: Intel Core i5 (4th Generation or newer) or equivalent
Operating System Windows 10 Pro (64-bit)
Windows 10 Enterprise (64-bit) version 1903 or later
Ensure that all Windows updates are installed.
Memory Recommended: 8 GB of RAM (minimum 4 GB)
Available Disk Space Recommended: 10 GB (minimum 5 GB), must be on drive C
Display Properties • Screen resolution: at least 1280 x 1024 pixels
• Color quality: at least 16-bit
Language Setting Must be English (United States).
Folders/files Description
\windows\system32\drivers\etc\hosts Local hostname resolution and networking information
\windows\system32\drivers\etc\bootptab Hardware addresses for the testhead1
\<installation folder>\autofile Fixtures ID auto numbers
\<installation folder>\boards Board test programs. If your board files are in a different folder,
back up that folder.
\<installation folder>\diagnostics\th1\ASRU_Reference System Calibration file (system dependent)
\<installation folder>\diagnostics\th1\config Testhead hardware configuration1
\<installation folder>\home User’s home folder
\<installation folder>\standard\config Testhead resources configuration1
\<installation folder>\dev Back up any ps (DUT power supply) files that were customized.
Any other custom folders and files containing important Any other user data
data.
• All software must be installed to drive C, which must also be the drive where
the operating system is installed.
• Disable anti-virus software before starting the installation. Otherwise, some of
the components might not install properly. Remember to reactivate the
anti-virus software after the i3070 software is installed.
• Unless directed otherwise, always accept the default selections. Otherwise,
errors could occur when using the software.
Before installation
Task Steps
Turn on .NET Framework: a Use Search on the taskbar to find Control Panel and click Programs and Features >
Turn Windows features on or off.
b In the Windows Features dialog box, select .NET Framework 3.5 (includes .NET 2.0
and 3.0) and click OK.
Task Steps
1 Insert the Keysight installation a If the User Account Control dialog box appears, click Yes to allow the installation
disk into the drive. to continue.
It should auto-start. b In the installation window, click Install Keysight i3070 Software.
If the installation does not auto-start after several seconds:
a Open Windows Explorer and browse to the disc.
b Double-click setup.exe in the W10\Software folder.
c If the User Account Control dialog box appears, click Yes to allow the installation
to continue.
2 Install required components, if The installer checks that system requirements are met and that required
missing: components are installed.
• If system requirements are not met, the installer may exit. See Table 1 for the
requirements.
• If any component is missing, a dialog box will be displayed.
a Click Install if you see any of these dialog boxes.
NOTE: This can happen at any time during the installation process.
b When installation is complete, click Next to continue.
3 Accept license agreement: a Accept the license agreement and click Next to proceed.
4 In the Destination Folder a Accept the default folder for installing the software, unless you have a specific
window: need to change it.
NOTE: Spaces are not allowed in the path of the destination folder, which must
be on drive C.
b Click Next.
Task Steps
5 Check license files for Testhead a In the License Folder dialog box, click Change.
Controller (node-locked):
(Licenses will be installed on the
controller together with the
i3070 software.
If you are installing on a test
development workstation, go to
step 6.)
b Select the temporary folder where you saved your license files and click OK.
c The installer lists the licenses found in the selected folder. Click Next.
d Click Yes to confirm you are installing on a testhead controller.
e Skip to step 7.
Task Steps
6 Check license files for a In the License Folder dialog box, click Change.
Test Development Workstation
(node-locked)
(Licenses will be installed on the
workstation together with the
i3070 software.)
b Select the temporary folder where you saved your license files and click OK.
c The installer lists the licenses found in the selected folder. Click Next.
d Click Yes to confirm you are installing on a test development workstation.
7 Confirm installation: The installer displays the third party applications to be installed.
a Click Install to begin installation.
b If prompted, click Install or Next to continue installation.
8 Finish installation: a When installation is completed, click Finish.
b Then click OK to reboot the computer.
9 Perform XVision optimization: After Windows restarts, the XVision Optimizer window appears.
a Click Yes to start the optimization process. It will take a few minutes to complete.
b Repeat the optimization process for each user account. (The XVision Optimizer
window will appear when each user logs on.)
10 If errors or other messages • If Quick Log Converter prompts for a missing template, ignore it.
appear: • If prompted to install a new version of Keysight IO Libraries, do not do so. Select
Skip this version and Quit.
Task Steps
The installation wizard procedure is now completed. Continue with the following tasks.
1 If installing on a testhead controller, a Right-click on the Testhead LAN icon in the Taskbar and select Status.
set the recommended Speed & b In the Testhead LAN Status dialog box, click Properties.
Duplex on Testhead LAN to prevent c In the Testhead LAN Properties dialog box, click Configure.
lost heartbeat failure:
d In the network adapter’s Properties dialog box, click the Advanced tab.
e Select Speed & Duplex and change its value according to the Module
Control Card in use.
ControlXTPB – Auto Negotiation
ControlXTPA – 100 Mb, half duplex
2 Check startup type for BOOTP a Open Control Panel and click Administrative Tools > Services.
Turbo: b In the service list, look for BOOTP Turbo and ensure that the Startup Type is
Automatic.
3 Set power options to never turn off a Open Control Panel and click Power Options.
the hard disks and monitor: b Click Change plan settings for the power plan in use.
c Set all options to Never and click Save changes.
4 Check for software patches: Go to www.keysight.com/find/i3070patches to check for any software patches
and install them.
5 Copy needed files: a Open a KornShell window.
b Execute setupEnv.ksh. (This will copy four files to the $HOME folder.
This step creates the user account and home env.)
c Close the KornShell window.
Task Steps
6 Complete the license installation: • To install the node-locked licenses on a testhead controller or test
development workstation, see Installing node-locked licenses on page 13.
• To allow access to optional feature licenses (which are floating licenses), see
Setting up client machines to use floating licenses on page 16.
7 To run the i3070 software when To allow the i3070 software to run when Windows Firewall is enabled, run the
Windows Firewall is enabled: following script, which creates inbound rules for the required ports and TCP/IP
addresses.
• Default ports enabled: 1337, 3071, 9090, 5672, 31883, 40100, 40102,
50100, 50102, 7030.
• Default IP addresses enabled: 10.3.112.1 to 10.3.112.255, 0.0.0.0,
192.168.1.1, 255.255.255.255.
Go to the C:\I3070_ICT\util folder, right-click CreateFirewallRule.bat and select
Run as administrator.
For the number of floating licenses that are available or in use, see License usage.
2 Check that the registry value for ICT3070_LICENSE_FILE is the same in:
• HKEY_CURRENT_USER\Software\Keysight\EEsof License Configuration, and
• HKEY_LOCAL_MACHINE\Software\Wow6432Node\Keysight\EEsof License Configuration
3 Check that the registry value for ICT3070_LICENSE_FILE contains the default license path
C:\ProgramData\Keysight\Licensing\Licenses\Other;
C:\ProgramData\Keysight\Licensing\Licenses\Server;
and any added floating license server path, if applicable
Task Steps
1 Insert the Keysight installation disk into the drive. It Click Install Keysight i3070 Help to install the online help.
should auto-start.
If the installation does not auto-start after several a Open Windows Explorer and browse to the disc.
seconds: b Double-click setup.exe in the W10\Help folder.
2 Close any open windows and log out.
E9901-96022
www.keysight.com