Daewoo FRS-2411 - FRS-2431
Daewoo FRS-2411 - FRS-2431
Daewoo FRS-2411 - FRS-2431
: FRS2411000
Service Manual
Side by Side Refrigerator
MODEL : FRS-2411
FRS-2431
✔ Caution :
In this Manual, some parts can be changed for improving, their
performance without notice in the parts list. So, if you need the
latest parts information,please refer to PPL(Parts Price List) in
Service Information Center (http://svc.dwe.co.kr).
1. EXTERNAL VIEWS...................................................................................................3
1-1. EXTERNAL SIZE ....................................................................................................................................................3
1-2. NAME OF PARTS...................................................................................................................................................4
2. SPECIFICATIONS.....................................................................................................6
2-1. OUTLINE................................................................................................................................................................6
2-2. ELECTRIC PARTS .................................................................................................................................................7
2-3. POWER CORD .....................................................................................................................................................10
2-4. DOOR COLOR .....................................................................................................................................................11
1
EXTERNAL VIEWS
1. EXTERNAL SIZE
FRS-2431
2
EXTERNAL VIEWS
FRS-2411
3
EXTERNAL VIEWS
FRS-2431
7
1
8
9
2
10
3
11
4
12
5
13
6 14
15
4
EXTERNAL VIEWS
FRS-2411
7
1
8
9
2
10
3
11
16
4
12
5
13
6 14
15
5
EXTERNAL VIEWS
2. SPECIFICATIONS
2-1. OUTLINE
DIVISION CONTENTS
FREEZER 231
TOTAL 656
WIDTH 925
EXTERNAL
DEPTH 896
DIMENSION (mm)
HEIGHT 1808
6
EXTERNAL VIEWS
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220 / 60 220 ~240/50 230 /50
(EUROP)
COMP MODEL X HBL27YG-3 X HCL27YG-2 HPL27YG-4A HPL30YG-5 MK183Q-L2U
2) RELAY
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220 / 60 220~240 / 50 230 / 50
3) STARTING CAPACITOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220 / 60 220~240 / 50 230 / 50
4) RUNNING CAPACITOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220 / 60 220~240 / 50 230 / 50
RATED CAPACITANCE X 10 § X X 5§ 5§ 5§
5) F-FAN MOTOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
6) R-FAN MOTOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
7
EXTERNAL VIEWS
7) C- FAN MOTOR
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
8) DEFROST HEATER
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
9) DRAIN HEATER
REFRIGERANT R134a
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
8
EXTERNAL VIEWS
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
OPERATING TEMPERATURE x 77
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
VOLTAGE ( V/HZ) 100 /50,60 110 / 60 115,120/60 127/60 220/60 220~240 / 50 230 / 50
9
EXTERNAL VIEWS
2- 3. POWER CORD
5 3011300801 BP-3PIN
Upper power cord's part code is only lead wire, without any kinds of terminal or houisng
10
EXTERNAL VIEWS
FRS-2411 (200V~240V)
Blowing Agent Cyclo Pentane
COLOR TYPE Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 Inox Looking Ellio 2
11
OPERATION AND FUCTIONS
1. DISPLAY
ON ON
SPEED bars OFF OFF OFF
(progressive) (progressive)
LOCK ON/OFF, SLEEP
DIAL DIAL DIAL DIAL DIAL
ON/OFF
Water / Cube Ice / Crushed Ice DIAL DIAL DIAL DIAL DIAL
12
OPERATION AND FUCTIONS
CONTENTS REMARK
6. "SLEEP" button
! Start by pushing the button ("ON" lights.)
@ Stop by pushing button again ("OFF" lights.)
# Automaticcally terminated after maximum 12 hours ("OFF" lights.)
7. Water/Ice button
! Select Water mode or Ice mode.
@ A rectangle Line around the icon lights up to indicate your selection is on.
Initial mode by power input: "Water"mode.
Progress: Water Cube Ice Crushed Ice Water
8. "LOCK" button
! Start by pushing the button ("LOCK" letters and icon light.)
* No other buttons and modes, buzzer sound are controllable.
@ Stop by pushing button again for a second ("OFF" and icon light.)
* Except "Lock"button, other buttonsare inactive during "Sleep"mode.
13
OPERATION AND FUCTIONS
CONTENTS REMARK
14
OPERATION AND FUCTIONS
CONTENTS REMARKS
-1 1. 0
-1 3. 0 ON poi nt
-1 5. 0
-2 0. 0
-2 1. 0
ON/ OFF DIFF
-1 6. 0
-1 8. 0
-2 0. 0 OFF poi nt
-2 2. 0
-2 6. 0
15
OPERATION AND FUCTIONS
CONTENTS REMARKS
14V
F Fan
12V
90min. 60min.
* STEP DIFF. :
fixed by MICOM
2. R-fan are controlled by ON / OFF point of each mode.
5. Prevention of weak/poor-refrigeration
1) When weak refrigeration is sensed, comp. is ON regardless of F-sensor.
2) When R-sensor reaches R-fan OFF point, comp. is controlled by F-sensor and
R-fan turns OFF.
3) Sensing point of weak refrigeration : R-sensor OFF point of each mode + 7 C
4) Termination point : Same as R-sensor OFF point of each mode
16
OPERATION AND FUCTIONS
CONTENTS REMARKS
9.3 C
8.3 C
7.3 C
Weak refrigeration point
6.3 C
5.3 C (Off point+7 )
2.65 C
1.65 C
0.65 C ON point
-0.35 C ON/OFF
2.3 -1.35 C
C
DIFF
1.3 C
0.3 C OFF point (0.35 deg)
-0.7 C
-1.7 C
17
OPERATION AND FUCTIONS
5. After Sleep mode stops all the electrical parts return to normal operation and Sleep
icon changes from "ON" to "OFF".
6. If Sleep mode starts during PRECOOL, it goes on again after the Sleep mode is
terminated.
7. If Sleep mode starts during Super FRZ., Super REF., it returns to previous set
modeafter the Sleep mode is terminated.
18
OPERATION AND FUCTIONS
2. Condition to start
1) The optical or light sensor in top middle of control panel senses surround light
and Silence mode starts if the amount of light sensed is below the standard value
for more than 1 minute.
(The mode does not start for initial 240 minutes to prevent down of cooling
performance.)
! Standard value to decide "night" : below 5 ~7 Lux (optical sensor surface)
@ Standard value to decide "daytime" : above 4~16 Lux
(optical sensor surface)
3. Control Method
Control Mode F-FAN R-FAN C-FAN
4. Termination Condition
The mode stops if lux value is above the standard for more than 1 minute.
1. CDS SENSOR
2. R SENSOR 1. F-FAN (14V, 12V, 10V)
3. F SENSOR
CONTENTS REMARKS
Control of Silence mode : operation mode when the optical sensor feels that it is
night
Normal control : daytime operation mode
(Refrigerator noise is relatively low at daytime.)
Load control : operation mode when inside temperature goes up due to an
increase of load (foods) or frequent door openings
19
OPERATION AND FUCTIONS
CONTENTS REMARKS
2) Display : "SPEED" lights until the mode and speed icons flicker.
5) Control Method
5-1) Control mode by F/R-door open time (over 30 seconds)
F/R-fan works by 14V respectively.
5-2) Control mode by [F-sensor On Point + 5 degree]
F-fan works by 14V.
5-3) Control mode by [R-sensor On Point + 5 degree]
R-fan works by 14V.
C-fan works by 10V as normal.
6) Conditions to stop
! The mode works for 20 minutes.
(If another condition happens at the end of the mode, it starts again.)
@ When it reaches to [F-sensor Off point], F-fan load control mode stops.
# When it reaches to [R-sensor Off point], R-fan load control mode stops.
20
OPERATION AND FUCTIONS
CONTENTS REMARKS
Door
On + 5deg
F/S
14V
F Fan 12V
20min.
On + 5deg
R/S
14V
12V
R Fan 20min.
Ref. Load
Door
On + 5deg
F/S
F Fan 12V
10V
20min.
On + 5deg
R/S
12V
R Fan 8V 20min.
Ref. Load
Frz. Stop Condition ;
Door Open Frz. Load Stop after 20min.
30sec. after open Frz. Load Start
Ref. Load Stop
Load Mode Start Frz. Overload Input
HTR
F /S
Com p
F Fan 12V
N o rm a l O p e ra ti o n
O n + 5deg
R /S
2 0 m in .
14V
R Fan 8V
D e f ro s tin g S ta rt C o n d itio n to s ta rt L o a d Re f . Lo a d St o p
M o d e , b u t avo id e d Re f . Lo a d M o d e
b u rin g d e f ro s tin g m o d e
21
OPERATION AND FUCTIONS
CONTENTS REMARKS
Sart
N 240 minutes ?
Normal Silence
Control Mode
Fan RPM
Fan RPM
Normal Overload
F Fan : 12V
F Fan : 10V 12V
R Fan : 12V
R Fan : 10V 12V
C Fan : 10V
C Fan : 10V 12V
N
Y F/S ON + 5deg?
Freezer
Compartment N
Overload Overload of both
Y R-sensor ON + 5deg? compartments
Refrigerator N
Compartment
Overload
Overload mode ? N
Y
Normal mode
Overload mode control
control
F load control ;
Y
over 20 min. ?
N
End
22
OPERATION AND FUCTIONS
Defrosting Cycle
INPUT Control Object
REMA
CONTENTS
RKS
23
OPERATION AND FUCTIONS
CONTENTS REMARKS
Start
Yes
No
No
No
Yes
No
No
No
No
24
OPERATION AND FUCTIONS
Defrosting Mode
INPUT Control Object
1. COMP
2. F-FAN
1. Defrosting Cycle
3. R-FAN
4. HEATER
CONTENTS REMARKS
1. Defrosting Mode
1) Time ; 50 minutes
2) Comp. / F-fan : ON
Pre-Cool R-fan : Control
Heater : OFF
3) If F-sensor≤ - 27 C, PRE-COOL becomes OFF.
1) Time : 5 minutes
Fan Delay Comp. : ON
F/R-fan, Heater : OFF
25
OPERATION AND FUCTIONS
CONTENTS REMARKS
1. How to start
1) Set "LOCK ON" first.
2) Push "Super Freezer" button 5 times while pushing "Freezer Set" button.
2. Display
Error code is displayed on Freezer temperature display part.
3. How to stop
1) Push "LOCK" button 1 time
2) It stops automatically 4 minutes after the start.
5. Error Code
26
OPERATION AND FUCTIONS
CONTENTS REMARKS
1) "F1" ERROR
Cause : F-sensor disconnection / short (pull-down)
Control : Comp. / F-fan ON for 25min., OFF for 25min.
if F-sensor is normal, the error is terminated automatically.
2) "r1" ERROR
Cause : R-sensor disconnection / short (pull-down)
Control : Condition of ambient temperature
RT/S In ERROR ~13 C 14 C ~19 C 20 C ~29 C 29 C ~
Work rate 8 / 12 7 / 13 8 / 12 8 / 12 9 / 11
ON/OFF
If R-sensor is normal, the error is terminated automatically.
3) "rt" ERROR
! Cause : RT-sensor disconnection / short (pull-down)
@ Control : Normal operation, deletion of control condition by RT-sensor
# If RT-sensor is normal, the error is terminated automatically.
4) "d1" ERROR
! Cause : D-sensor disconnection / short (pull-down)
@ Control : Time limit (30min.) of defrosting-return
# If D-sensor is normal, the error is terminated automatically.
6) "C1" ERROR
! Cause : in case comp. works for over 3 hours when D-sensor temp. is over -5 C
@ Control : Normal operation
# When D-sensor temp. is below -5 C in comp. OFF, it is terminated.
7) "F3" ERROR
! Cause : in case defrosting-return is done by time limit of 80min.
@ Control : Deletion of Pre-cool mode in defrosting mode
# If defrosting-return is done by D-sensor, it is terminated.
27
OPERATION AND FUCTIONS
CONTENTS REMARKS
9) "EI" ERROR
! Cause : I-SENSOR disconnection / short (pull-down)
@ Control : After water suppy, Ice drop every 4.8hour.
# Termination : When I-SENSOR is normal.
28
OPERATION AND FUCTIONS
Forced Defrosting
INPUT Control Object
2. How to proceed
1) Delete Pre-cool mode. (Others are same as normal defrosting.)
2) Heater is ON regardless of D-sensor temp. at first 30 seconds.
( Check of defrosting current)
D-sensor
Defrosting Mode
Initial or first power input (power plugin)
CONTENTS REMARKS
If D-sensor temp. ≤ 3.5 C , defrosting mode starts from Pre-cool at first Comp. is delayed for 6 min.
power input. at the initial defrosting.
F-PCB buttons
Door Switch BUZZER
Initial Power Input
CONTENTS REMARKS
29
OPERATION AND FUCTIONS
CONTENTS REMARKS
1. Conditions to turn on LCD Light
1) Power input (plugin)
2) When any button on the panel is pushed, first the back light turns on, then
button control is done.
3) When F/R door is open, the light turns on.
1. Start
Push "REFRIGERATOR SET." button for 3 seconds within 10 seconds just
after power input.
2. Control
1) Electrical components are OFF for 3 hours.
2) Display operates in normal way.
Back Up Function
INPUT Control Object
None
CONTENTS REMARKS
30
OPERATION AND FUCTIONS
1 min. 1 min.
ON
OF F
R F AN
0. 5s ec .
ON
F FA N
OF F
1. 0s ec .
ON
C F AN
OF F
1. 5s ec .
OP EN
DOOR
CLOSE
ON
R FAN
OF F
20.5 sec. (0.5sec.
for first 2 hrs.)
ON
F FAN
OF F
21sec. (1sec. for first 2 hrs.)
31
OPERATION AND FUCTIONS
Demonstration Function
INPUT Control Object
"LOCK" button COMP
"REFRIGERATOR SET." button F-FAN
"SLEEP" button R-FAN
CONTENTS REMARKS
1. Start
1) Set "LOCK ON" first.
2) Push "SLEEP" button 5 times while pushing "REF SET." button simultaneously.
2. Control
1) All other electrical components are OFF except for F-fan / R-fan.
2) Fan Control
DOOR OPEN FAN ON / DOOR CLOSE FAN OFF
3) Display : Normal mode (3.8sec.) SPEED(3sec.) Silent mode(3sec.)
Sleep mode (3sec.)
3. Stop or Termination
1) During Demo mode push "SLEEP" button 5 times while pushing "REF SET."
button simultaneously.
2) Power in again.
32
OPERATION AND FUCTIONS
R-SENSOR
R26
R70 OP 1-
1-1
R71
OP1-
1-2
Summary of Function
CONTENTS REMARKS
33
OPERATION AND FUCTIONS
R-SENSOR
R26
R70 OP 1-
1-1
R71
OP 1-2
Summary of Function
CONTENTS REMARKS
34
OPERATION AND FUCTIONS
START
ICE MAKER
ICE Making
Mode
STOP the water input mode
ICE DROP
Mode ICE Drop
RETURN
2) Ini tial Power inpu t => Ice Make r is horizontal => Proceed
from Ice maker Mode
35
OPERATION AND FUCTIONS
CONTENTS REMARKS
START
NO
NO I-S<-9.5 C
130 min passed?
YES YES
NO NO
I-S<-12.5 C 15 min passed?
YES YES
1) I-S is -12.5 C and below after 130 min.=> Ice maker complete
2) Although I-S isn't -12.5 C below for 130 min, I-S maintains -9.5 C below continuously
=> Ice maker comlpete
status
Ice tray Start ICE DROP
level 8-11 sec Max 1.1 sec 8.5-12.2 sec 0.2 sec
36
OPERATION AND FUCTIONS
CONTENTS REMARKS
3. Water-Input MODE
START
Inlet value ON
N
1 Sec passed after inlet
value on?
Y
N
Water input pulse >10
Y
Flow-Sensor Error mode
Y
Water input pulse >target pulse
N
time> target time
STOP
37
OPERATION AND FUCTIONS
3) Display
38
OPERATION AND FUCTIONS
Contents Remark
4-1)Crushed Ice
D.P SW (In)
D
D.P Lamp A
C
D.P S/V (Out) A
Crusher Motor
D.P SW (In)
D.P Lamp A D
Cube S/V A B
D.P S/V(Flap) A C
Gear Motor
4-3) Water
D.P SW (In)
D
D.P Lamp A
Water S/V
39
OPERATION AND FUCTIONS
MICOM Circuit
Power
Circuit
* DC output
15.7V
11.96V
40
OPERATION AND FUCTIONS
SMPS *Minimum
IC PIN standard
3,4 voltage at
OVP start :
23.2V
41
OPERATION AND FUCTIONS
SMPS
IC PIN
3,4
42
OPERATION AND FUCTIONS
Sensors
Circuit Diagram
2) How it works ;
Working Point Low ON Mid OFF High OFF
Working Temp. -11.0 C -20.0 C - 26.0 C
Resistance 14.74k 22.33k 30.92k
Sensing Voltage 3.50 V 3.00 V 2.14 V
[ D-sensor ]
It senses return point of defrosting heater.
Working Point Return point of defrosting heater
Working Temp. 10 C
Resistance 19.53k
Sensing Voltage 3.1 V
[ R-sensor ]
1) It senses the temperature of refrigerator compartment and controls R-fan ON / OFF.
2) How it works ;
Working Point Low ON Mid OFF High OFF
Working Temp. 2.65 C 0.3 C -1.7 C
Resistance 26.88k 29.34k 32.00k
Sensing Voltage 2.90V 2.81V 2.74V
43
OPERATION AND FUCTIONS
* In case refrigeration of refrigerator compartment is poor or insufficient though comp. and R-fan
operate in normal way ;
1) Cut J18 on M-PCB, then temp. is lowered -2 C than [Mid OFF point].
2) In addition to 1) action, cut J22 on M-PCB, then the temp. is lowered -1 C more.
Relay Function
Circuit Diagram
How it works ;
ON Condition OFF Condition
Control
Control MI COM IC 2 Output MICOM
Method IC03 Output PIN
POR T PIN POR T
COMP REPLAY #1 3.7V #10 0.7V #1 0V #10 12V
R-LAMP REPLAY #4 3.7V #11 0.7V #4 0V #11 12V
DIS-LAMP REPLAY #3 3.7V #12 0.7V #3 0V #12 12V
DISP-SOL REPLAY #5 3.7V #13 0.7V #5 0V #13 12V
WATER(ICE) REPLAY #1 3.7V #10 0.7V #1 0V #10 12V
WATER(DIS) REPLAY #4 3.7V #11 0.7V #4 0V #11 12V
GEAR-M REPLAY #3 3.7V #12 0.7V #3 0V #12 12V
D-HTR REPLAY #5 3.7V #13 0.7V #5 0V #13 12V
F-LAMP REPLAY #4 3.7V #11 0.7V #4 0V #11 12V
CUBE-SOL REPLAY #4 3.7V #11 0.7V #4 0V #11 12V
W /S HTR REPLAY #2 3.7V #14 0.7V #2 0V #14 12V
44
OPERATION AND FUCTIONS
Fan Function
How it works ;
ON Condition OFF Condition
Control Control
MICOM Port MICOM Port
Object Method IC Collector IC Collector
31 32 33 31 32 33
Low (10V)
5V 0V 0V 10.35V 0V
operation
Mid (12V)
F-FAN 0V 5V 0V 12.19V 5V 5V 5V 0V
operation
High (14V)
0V 0V 0V 14.38V 0V
operation
45
OPERATION AND FUCTIONS
46
DIAGRAM
WIRING DIAGRAM
47
DIAGRAM
48
DIAGRAM
49
DIAGRAM
Front PCB
50
INSTALLATION GUIDE
Installation Preparation
Installation Preparation
51
INSTALLATION GUIDE
If the refrigerator can not enter the door, follow these steps.
careful !)
52
INSTALLATION GUIDE
Installation Procedure
1. Join [Connector A], [Connector B] and [Water Valve] to the tap water lines.
1) Switch off the main water line(valve). Achtung
2) Connect [Water Valve] and [Connector A]. The water valve should be connected to
the cold water line, otherwise there can be
3) Join [Connector A], [Connector B] to the tap water lines a problem of cold water supply."
Use only [Connector A + Water Valve] in case there's only one tap
water line.
Apply the sealing tape to all the joints as the figure shows.
If the connectors(valves) do not fit the existing water line, call your
service agent for additional guideance and action.
53
INSTALLATION GUIDE
Achtung
Leave a sufficient distance when cutting the tubes.
Water Tube
54
INSTALLATION GUIDE
4 Turn
end.
the hinge fastener tightly to the
ground wire.
55
INSTALLATION GUIDE
Refrigerator
Refrigerator Leveling
Leveling & Door & If needed.)
Adjustment(
Door Adjustment ( If needed. )
Refrigerator must be level in order to maintain optimal performance and desirable front appearance.
(If the floor beneath the refrigerator is uneven, freezer and refrigerator doors look unbalanced.)
Hinge Bolt
The front of refrigerator needs to be higher just a little than the back for easy
Caution door closing, but if the wheel is raised too much for door balance, i.e. front of
refrigerator is too higher than the back, it can be difficult to open the door.
After installation and/or door leveling, fasten front cover Remove the back paper of the tape on the filter
with screws.(Remove the screws on the front bottom holder and attach the filter holder on a suitable
panel first. Click and screw the cover) place.
56
EXPLODED VIEW AND PARTS LIST
15
CABINET 14 20
19
13 18
8 1 11
10 12
9
7
6 4
21
2
23
25
31 24 29
32
22
26
30
27 28
33
34
MECH ROOM 54 55
56 47
48
49
52
46
53
45
50 41
51
43 44-1 44-2
42
39 38
40
36 37
57
EXPLODED VIEW AND PARTS LIST
FRS-2411
57
58
R ROOM 59
61
62 60
63
64
65
66
70 67
68
71 69
86 85 84
72
74 87
96
76 75 95
73
77 92
93
94
79 88
80 89
81 91 90
82
83
98 99
97
58
EXPLODED VIEW AND PARTS LIST
FRS-2411
F ROOM 119
118 116
117
122
121 115
120
114
101
102
103
104
110 105
106
111
112
126
107
132
74
133 75
100
109
134
59
EXPLODED VIEW AND PARTS LIST
FRS-2411
147
146
143
138 139
142
F DOOR
138-3 151
138-2
138-1 151-5 151-6
151-4
151-3
149
145
135 150
151-1 151-2
140
141
152
154
136
153
155
156
137
148
144
157
160
158 159
161
146 147
R DOOR 143
170-3 139
170-1
170-12 170-13
170-14
170-9
142
162
170-10
145
163 140
141
164 170-11
165
166 170-2 170-4 170-5
167
169
148
144
170
60
EXPLODED VIEW AND PARTS LIST
17
FRS-2431
16
15
CABINET 14 20
19
13 18
8 1 11
10 12
9
7
6 4 21
2
23
25
31 24 29
32
22
26
30
27 28
33
34
MECH ROOM 54 55
56 47
48
49
52
46
53
45
50 41
51
43 44-1 44-2
42
39 38
40
36 37
61
EXPLODED VIEW AND PARTS LIST
FRS-2431
57
58
R ROOM 59
61
62 60
63
64
65
66
70 67
68
71 69
86 85 84
72
74 87
96
76 75 95
73
77 92
93
94
79 88
80 89
81 91 90
82
83
98 99
97
62
EXPLODED VIEW AND PARTS LIST
FRS-2431
F ROOM 119
118 116
117
122
121 115
120
114
101
102
103
104
110 105
106
111
112
126
107
132
74
133 75
100
109
134
63
EXPLODED VIEW AND PARTS LIST
FRS-2431
147
146
143
138 139
142
F DOOR
138-3 151
138-2
138-1 151-5 151-6
151-4
151-3
149
145
135 150
151-1 151-2
140
141
152
154
136
153
155
156
137
148
144
157
160
158 159
161
147
168
R DOOR 146
143
168-2 139
168-1 142
162
145
140
163 141
164
165
166
167 148
144
64
EXPLODED VIEW AND PARTS LIST
Total Parts List ✔ CAUTION : In this Service Manual, some parts can be changed for
improving their performance without notice in the parts
✫ FRS-2411 list. So, if you need the latest parts information, please
refer to PPL(Parts Price List)in Service information
FRS -2411 £“£“£“Parts List Center(http://svc.dwe.co.kr)
NO PART CODE PART NAME Q ' TY REMARK
1 3000003600 ASSY CAB URT 1
2 3012917600 HINGE *T *R AS 1 PO T3.0
3 3012918500 HINGE *T *L AS 1 PO T3.0
4 3016031400 SCREW SPECIAL 2
65
EXPLODED VIEW AND PARTS LIST
66
EXPLODED VIEW AND PARTS LIST
67
EXPLODED VIEW AND PARTS LIST
68
EXPLODED VIEW AND PARTS LIST
69
EXPLODED VIEW AND PARTS LIST
70
EXPLODED VIEW AND PARTS LIST
71
EXPLODED VIEW AND PARTS LIST
72
EXPLODED VIEW AND PARTS LIST
73
EXPLODED VIEW AND PARTS LIST
74
EXPLODED VIEW AND PARTS LIST
75
EXPLODED VIEW AND PARTS LIST
76
DAEWOO ELECTRONICS Corp.
686, AHYEON-DONG MAPO-GU
SEOUL, KOREA
C.P.O. BOX 8003 SEOUL, KOREA