The document describes a remote tank level and pressure monitoring system called DataOnline. The system uses Remote Monitoring Units (RMU) that can replace or connect to existing DP gauges for monitoring tank levels and pressures digitally from anywhere via the internet. The RMU allows for continuous remote monitoring without calibration charts. It has options for 500 PSI pressure rating, digital readout of level and pressure, alarms, and outputs level and pressure signals. The system monitors various application areas like cryogenic storage tanks and transport tankers.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
388 views2 pages
Remote Tank Level: & Pressure Monitoring System
The document describes a remote tank level and pressure monitoring system called DataOnline. The system uses Remote Monitoring Units (RMU) that can replace or connect to existing DP gauges for monitoring tank levels and pressures digitally from anywhere via the internet. The RMU allows for continuous remote monitoring without calibration charts. It has options for 500 PSI pressure rating, digital readout of level and pressure, alarms, and outputs level and pressure signals. The system monitors various application areas like cryogenic storage tanks and transport tankers.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
REMOTE TANK LEVEL
& PRESSURE MONITORING SYSTEM
Now access your Tank level and pressure from
anywhere through DataOnline Remote Monitoring Units(RMU). The unit is designed to replace or tap online with existing DP gauges and is ideal for rugged outdoor application. DataOnline RMU allows digital Tank Monitoring solution eliminating hassels of calibration chart associated with traditional analog tank monitoring.
DataOnline end to end solution puts you in control with
power to continuously monitor access and manage your remote tank parameters via the internet. From logistics to maintainance and Environmental compliance to sales, DataOnline has the right monitoring solution.
Feature Comparision DP GAUGE
TELEMETRY 500psi pressure rating Oxygen cleaned ¾” FPT back mount Digital level readout Digital pressure readout No calibration charts required One guage for upto 20,000 gallons One guage for LOX / LIN / LAR / N20 / CO2 (8) level readout options (3) pressure readout options (3) adjustable pressure alerts User programmable Telemetry ready Digital & 4-20 mA output signals NEMA 4 water and weather tight Equalization wave included Integrates with other alarm systems Application areas Without Radio - Basic Units Cryogenic liquid level monitoring of stroage and Display Resolution (+/-) transport tanks. %Full= 5% liters (liquid)=10 In.WC*(low DP Air seperation units model) = 0.7 Non-vaccuum type large cryogenic storage tanks GAL=5 Nm3(gas)=10 psi=5 Monitoring pressure drop in air sucction filter in scf(x100 =100) kg=10 kPa=5 large air compressor lbs=10 In.WC*=3.3 bar=0.2 Measuring pressure drop across cryogenic fluid Operatiing temperature -30°C to +70°C on line filters
With Radio - for remote monitoring Programmable Features
Network of cryogenic storage tanks at distant Product type: Any Liquid gases for level measurement locations from centralized project/ production centre Unit of Measure - Level Percent Full (% Full), Liters, Gallons (gal) Fleet of transport tankers Kilograms (kg), Pounds (lbs), Inches H20 Hazardouslocation and fluids installation Normal Cubic Meters (Nm3) Difficult to access locations Standard Cubic Feet (scf) Unit of Measure - Pressure Physical Poundsoer Square inch (psi) Bar Kilopascals (kPa) Approximately 7”w x 11”h x 5”d (including SS shroud) ¾” FPT back mount (compantible with Alert Programmability existing DP mounts). (3) level alerts programmable from 0-100% in Gauage is housed in water resistant enclosure 5% increments (NEMA 4). (3) pressure alerts programmable from 0-Psi in Level Range : 0-750* WC* (0-160 WC* for low 5psi increments DP model) Alerts programmable as normally open or closed Pressure Rating : 500 psig Maximum Differential Pressure : 100 psig Maximum Tank Dimensions (Low DP model 30 psig) Diameter and length
Electrical Inputs Tank Orientation
Power options Vertical & Horizontal
Solar, 220VAC, 110VAC, 12VDC, 24VDC & 48VDC Options Outputs Industrial Alert, Hospital Alert, Sensor Telemetry (6) Programmable alerts (3- level and 3 pressure Accessories and Service for phone transmission or local alarm relay) (2) 4-20 mA singals (for level and pressure) (2) digital singals (for level and pressure) unit of measure indicator Level & Pressure display : Large, 5-character, 0.4” high LCD display Low battery indicator Sensor Accuracy +/-1% Operator Interface: Keypad ( no computer required)