2-Propylheptanol: Decyl Alcohol (All Isomers)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

propylheptanol

HOME COMMODITIES CLEANING LIBRARY TOOLS ACCOUNT


 Log O

2-Propylheptanol MARPOL Annex II Chemical Cargo

Product Name: Decyl alcohol (all isomers) Updated: May 30, 2013 20:23
Specification: Trade Name     BASF    

  Summary    Specs/Handling    IBC Code    IBC Code Pre-2021    USCG/Reactivity    Coating    Cleaning    Safety/SDS    Synonyms    Notes & Docs  

Chemical Characteristics     

Prewash:     See Note Melting/Pour Point:     <-50 °C Surface Tension:     Low


Pollution Cat (c):     Y Heat Voyage:     Not Required Water Solubility:     Slight
Viscosity:     15.3 mPa.s @ 20 °C Heat Discharge:     Not Required Reactivity w/Water:     Not Available
Visc. ≤ 50 mPa.s @:     Not Pertinent Flash Point:     100 °C Flammable Range:     0.6-6.9 %
Vapor Detection (k):     No OEL/PEL/WEL/TLV-TWA:   Odor Threshold:  

Stainless Steel Epoxy Zinc View From/To Cleaning Recommendations

Cleaning Method
2-Propylheptanol is either not soluble or only partially soluble or miscible in water. However it should be able to be cleaned using water only. Water washing will displace the
product remaining in the tank, pump and pipelines.
Cleaning Steps

Description Time Temperature Notes

1:Machine Wash Sea Water 1.5 Hours Ambient Water temp at least 10°C above the melting point of the cargo.

2:Machine Wash Sea Water 1.5-2.0 Hours 40-60

3:Fresh Water Rinse 0.3-0.5 Hours Ensure all tank surfaces are rinsed.

4:Gasfree

5:Eject and Mop Dry

6:Inspect and check wallwash results to determine


if further cleaning is required
Note: The TIME indicated above is based on cleaning to a water white standard in a 1000 m3 tank with fixed tank cleaning machines with complete tank coverage.

Category Note Edit

 Cleaning-General  Generic Milbros After Discharge Check List

After_Discharge_Check_List.pdf

 Cleaning-General  INTERTANKO Cargo Tank Cleanliness Standards for Chemical Tankers - 2017
Document reproduced and available with permission from INTERTANKO.

INTERTANKO_Cargo_Tank_Cleanliness_Standards_for_Chemical_Tankers.pdf

 Cleaning-General  The recirculation or spraying of Low Flash (<60C) Solvents to clean tanks is not recommended and is not accepted by many