Granada Consolidated Report
Granada Consolidated Report
COLLEGE OF ENGINEERING
DEPARTMENT OF CIVIL ENGINEERING
PCS 1
PROFESSIONAL COURSE SPECIALIZE 1
CONSOLIDATED
REPORT
GRANADA, JADE N.
BSCE - 4C
N
W E
T E
THIS SI
VICINITY MAP
SCALE: DRAWN NTS
E
N
LI
TY
R
PE
O
PR
N E
W S
29600
PERSPECTIVE
14600
SITE DEVELOPMENT PLAN
SCALE: DRAWN NTS
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
PERSPECTIVE,
JUAN PAULO BERSAMINA PROPOSED FOUR-STOREY
A-1
GRANADA, JADE N. VICINITY MAP AND
BSCE 4C COMMERCIAL BUILDING CHECKED
SITE DEVELOPMENT
APPROVED PLAN
TAGAYTAY CITY, CAVITE OWNER DATE
Y Y
1 2 3 4 5 6 1 2 3 4 5 6
A A
X X
B B
UP UP
X X
C C
UP UP
D D
Y Y
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
A-2
GRANADA, JADE N.
BSCE 4C COMMERCIAL BUILDING CHECKED AND SECOND FLOOR
PLAN
APPROVED
A A
X X
B B
UP
UP
DN DN
X X
C C
UP
D D
BALCONY BALCONY BALCONY BALCONY
E E
Y Y
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
A-3
GRANADA, JADE N.
BSCE 4C COMMERCIAL BUILDING CHECKED AND FOURTH FLOOR
PLAN
APPROVED
X
B
X
C
D
Y
ROOF DECK
SCALE 1:200
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
A-4
GRANADA, JADE N.
BSCE 4C COMMERCIAL BUILDING CHECKED ROOF DECK
APPROVED
2000
FOURTH FLR CEILING
ROOF DECK
200 FOURTH FLR CEILING
3000
TF CEILING
3000
TFL
SF CEILING
TFL
200
SF CEILING
3000
SFL
FF CEILING
SFL
200
FF CEILING
4000
FFL
NGL
FFL
200
NGL
ROOF DECK
FOURTH FLR CEILING ROOF DECK
FOURTH FLR CEILING
200 mm THK
16000
TFL
SF CEILING
200 mm THK TFL
FIREWALL FIREWALL SF CEILING
SFL
FF CEILING SFL
FF CEILING
FFL
NGL FFL
NGL
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
FRONT VIEW,
JUAN PAULO BERSAMINA PROPOSED FOUR-STOREY REAR VIEW,
A-5
GRANADA, JADE N.
BSCE 4C COMMERCIAL BUILDING CHECKED LEFT SIDE VIEW AND
RIGHT SIDE VIEW
APPROVED
ELEVATIONS
TAGAYTAY CITY, CAVITE OWNER DATE
600
2000
ROOF DECK
200
FOURTH FLR CEILING
3000
FOURTH FLR LINE
200
TF CEILING
3000
16600
TFL
SF CEILING
3000200
SFL
200
FF CEILING
4000
FFL
200
NGL
LONGITUDINAL SECTION
SCALE 1:200
DOOR 1 DOOR 2
TFL
DOOR SCHEDULE
SF CEILING
SCALE NTS
SFL
FF CEILING
FFL
NGL
CROSS SECTION
SCALE 1:200
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
LONGITUDINAL
JUAN PAULO BERSAMINA PROPOSED FOUR-STOREY
A-6
GRANADA, JADE N. SECTION, CROSS
BSCE 4C COMMERCIAL BUILDING CHECKED
SECTION AND DOOR
APPROVED SCHEDULE
TAGAYTAY CITY, CAVITE OWNER DATE
1 2
A B 1 2
SFFL
19 18 17 16 15 14 13 20 21 22 23 24 25 26 SFFL
SFFL
SFFL
12
11
13 12
10
14 11
9
15 10
8
16 9
7
17 8
6
18 7
5
19 6
4
10 5
3
20 4
2
21 3
1
22 2 FFFL
1
FFFL FFFL
FFFL UP
UP
1 2
A B
TFFL
TFFL
TFFL TFFL
14 13 12 11 10 9 8 15 16 17 18 19 20 21
8 7
9 6
10 5 7
11 4 6
12 3
5
13 2 4
14 1 3
2
SFFL SFFL
1
SFFL
SFFL
UP
UP
FIRE EXIT STAIR PLAN 2 IS APPLIED FROM MAIN STAIR PLAN 2 IS APPLIED FROM 2ND
2ND FLOOR TO FOURTH FLOOR FLOOR TO FOURTH FLOOR
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
A-7
GRANADA, JADE N. 1 & 2 AND
BSCE 4C COMMERCIAL BUILDING CHECKED
MAIN STAIR
APPROVED 1 & 2 PLANS
TAGAYTAY CITY, CAVITE OWNER DATE
GENERAL NOTES:
1.0 STANDARD AND REFERENCES
D. DESIGN STRESSES
THE FOLLOWING SHALL GOVERN THE DESIGN, FABRICATION AND CONSTRUCTION OF THE PROJECT.
CONCRETE FOR FOOTINGS, COLUMNS, BEAMS AND SLABS
1.1 NATIONAL STRUCTURAL CODE OF THE PHILIPPINES (N.S.C.P.) 2015. 7TH EDITION (ISSN 2094-5477)
COMPRESSIVE STRENGTH AT 28 DAYS fc’ = 21.0 MPa (3000 psi)
REINFORCING STEEL BARS
2.0 DESIGN CRITERIA
BARS IN BEAMS AND COLUMNS fy' = 420 MPa (60 000 psi)
2.1 LOADINGS
BARS IN FOOTINGS AND SLABS fy’ = 276 MPa (40 000 psi)
A. DEAD LOAD
SLAB
3.0 IN THE INTERPRETATION OF THE DRAWING, INDICATED DIMENSIONS SHALL GOVERN AND DISTANCES
CONCRETE (150mm x 23.6kN / cu.m Density of Unit) 3.54 kPa
AND SIZES SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES.
CERAMIC OR QUARRY TILE (20mm) ON 25mm MORTAR BED 1.10 kPa
CEMENT FINISH (25mm) ON STONE CONCRETE FILL 0.575 kPa
4.0 IN REFERENCE TO OTHER DRAWINGS, SEE ARCHITECTURAL DRAWINGS FOR DEPRESSIONS, OPENINGS,
INTERIOR PARTITION WALL 1.00 kPa
PARTITIONS, LOCATIONS AND ETC. OF DIFFERENT BUILDING ELEMENTS.
SUSPENDED METAL LATH AND GYPSUM PLASTER 0.48 kPa
ELECTROMECHANICAL 0.10 kPa
5.0 IN CASE OF DISCREPANCIES AS TO THE LAYOUT, DIMENSIONS, AND ELEVATIONS BETWEEN THE
BITUMINOUS SMOOTH SURFACE 0.07 kPa
STRUCTURAL PLANS AND ARCHITECTURAL DRAWINGS, THE CONTRACTOR SHALL NOTIFY BOTH THE
WALL
STRUCTURAL ENGINEER AND THE ARCHITECT.
EXTERIOR WALL (16.5-kN/m3 Density of Unit)
FULL GROUT (EACH FACE PLASTERED) 4.07 kPa
6.0 ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 95 BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE IN SO FAR AS THEY DO NOT CONFLICT WITH THE LOCAL
INTERIOR PARTITION WALL 1.00 kPa
BUILDING CODE.
GLASS WALLS, RAILINGS 0.38 kPa
B. LIVE LOAD
7.0 ACI REFERS TO AMERICAN CONCRETE INSTITUTE AND ASTM TO AMERICAN SOCIETY FOR TESTING
BUSINESS/OFFICE UNIT 2.90 kPa
MATERIALS.
LOBBIES/PATHWAY 4.80 kPa
RESTROOMS 2.40 kPa
8.0 CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN
EXIT FACILITIES 4.80 kPa
OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS.
ROOF DECK LIVE LOAD 2.40 kPa
C. SEISMIC LOAD
9.0 SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF GLASS FRAME WALLS AND
NEAREST ACTIVE FAULT VALLEY FAULT SYSTEM
MISCELLANEOUS IRON, ETC. SHALL BE SUBMITTED FOR ENGINEER’S APPROVAL BEFORE FABRICATION.
DISTANCE 12.2 km
SOURCE TYPE A
10.0 CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS, EQUIPMENT
CATEGORY TYPE IV
AND MECHANICAL BASES THAT ARE REQUIRED BY THE ARCHITECTURAL, ELECTRICAL AND
OCCUPANCY STANDARD
MECHANICAL DRAWINGS.
IMPORTANCE FACTOR 1.0
ZONE: 4 0.40
11.0 ALL RESULTS OF MATERIAL TESTING FOR CONCRETE, REINFORCING BARS, AND STRUCTURAL STEEL
SPECIAL REINFORCED CONCRETE SHEAR WALLS 0.85
MUST BE NOTED AND APPROVED BY THE STRUCTURAL DESIGNER.
SOIL TYPE SD
NEAR SOURCE FACTOR, Na 1.0
NEAR SOURCE FACTOR, Nv 1.112
COEFFICIENT, Ca 0.44
COEFFICIENT, Cv
BUILDING HEIGHT, hn
0.71168
16 m
GENERAL NOTES
SCALE:
GROUND FLOOR1 PLAN
SCALE: : 100 MTS SECOND FLOOR 1PLAN
SCALE: : 100 MTS THIRD FLOOR
1 : 100 MTS PLAN
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
S-1
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED GENERAL NOTES
APPROVED
29600 29600
6000 6000 5600 6000 6000 6000 6000 5600 6000 6000
4867
B C1F1 C1F1 C1F1 C1F1 C1F1 C1F4 B C1 C1 C1 C1 C1 C1
14600
14600
4867
4867
C C1F1 C1F1 C1F1 C1F1 C1F1 C1F4 C C1 C1 C1 C1 C1 C1
4867
4867
D C1F1 C1F1 C1F1 C1F1 C1 C1F4
D C1 C1 C1 C1 C1 C1
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
S-2
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED AND GROUND FLOOR
COLUMN LAYOUT
APPROVED
29600 29600
6000 6000 5600 6000 6000 6000 6000 5600 6000 6000
STAIR
2B-2
4867
WELL
2B-3
2B-3
2B-4
2B-5
2B-1
4867
2S-2 2S-3 2S-2 2S-2
2B-18
1267
2S-1
2B-16 2B-14 2B-17 2B-14 2B-14
B C1 C1 C1 C1 C1 C1 B C1 C1 C1
C1 C1 C1
14600
4867
14600
2B-6
2B-7
2B-8
2B-8
2B-7
2B-9
STAIR
4867
2S-4 2S-4 2S-4 2S-4
WELL
2B-11
2B-10
4867
2B-4
2B-4
2B-5
2S-2 2S-2 2S-2 2S-2
4867
2S-5
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
SECOND FLOOR
JUAN PAULO BERSAMINA PROPOSED FOUR-STOREY
S-3
GRANADA, JADE BEAM FRAMING PLAN
BSCE 4C COMMERCIAL BUILDING CHECKED
AND COLUMN
APPROVED LAYOUT
TAGAYTAY CITY, CAVITE OWNER DATE
1 2 3 4 5 6 1 2 3 4 5 6
29600 29600
6000 6000 5600 6000 6000 6000 6000 5600 6000 6000
STAIR
4867
3B-2
4867
WELL
3B-3
3B-3
3B-4
3B-5
3B-1
3B-21
1267
3S-1
3B-19 3B-17 3B-20 3B-17 3B-17
B C1 C1 C1 C1 C1 C1
B C1 C1 C1 C1 C1 C1
4867
3B-8
4867
3B-6
3B-7
3B-7
3B-9
3S-4 3S-4 STAIR 3S-4 3S-4
3B-8
WELL
16833
16833
3B-17 3B-17 3B-18 3B-17 3B-17
C C1 C1 C1 C1 C1 C1
C C1 C1 C1 C1 C1 C1
4867
3B-11
3B-11
3B-10
4867
3B-4
3B-4
3B-5
3S-2 3S-2 3S-5 3S-2 3S-2
3B-12
2233
2233
3B-13
3B-13
3B-12
3B-12
3B-12
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
THIRD FLOOR
JUAN PAULO BERSAMINA PROPOSED FOUR-STOREY
S-4
GRANADA, JADE BEAM FRAMING PLAN
BSCE 4C COMMERCIAL BUILDING CHECKED
AND COLUMN
APPROVED LAYOUT
TAGAYTAY CITY, CAVITE OWNER DATE
1 2 3 4 5 6 1 2 3 4 5 6
29600 29600
6000 6000 5600 6000 6000 6000 6000 5600 6000 6000
STAIR
4B-2
4867
WELL
4867
4B-3
4B-3
4B-4
4B-5
4B-1
4B-21
1267
4S-1
4B-19 4B-17 4B-20 4B-17 4B-17
B C1 C1 C1 C1 C1 C1 B C1 C1 C1 C1 C1 C1
4B-8
4867
4867
4B-6
4B-7
4B-7
4B-9
4S-4 4S-4 STAIR 4S-4 4S-4
4B-8
WELL
16833
16833
C C1 C1 C1 C1 C1 C1 C C1 C1 C1 C1 C1 C1
4B-11
4B-11
4B-10
4867
4867
4B-4
4B-4
4B-5
4S-2 4S-2 4S-5 4S-2 4S-2
4B-12
2233
4B-13
4B-13
4B-12
4B-12
2233
4B-12
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
FOURTH FLOOR
JUAN PAULO BERSAMINA PROPOSED FOUR-STOREY
S-5
GRANADA, JADE BEAM FRAMING PLAN
BSCE 4C COMMERCIAL BUILDING CHECKED
AND COLUMN
APPROVED LAYOUT
TAGAYTAY CITY, CAVITE OWNER DATE
1 2 3 4 5 6 1 2 3 4 5 6
29600 29600
6000 6000 5600 6000 6000 6000 6000 5600 6000 6000
STAIR
RDB-2
RDB-3
RDB-3
RDB-4
RDB-5
RDB-1
4867
4867
WELL RDS-3
RDS-2 RDS-2 RDS-2
RDB-17
1267
RDS-1
RDB-16 RDB-14 RDB-15 RDB-14 RDB-14
B C1 C1 C1 C1 C1 C1
B C1 C1 C1 C1 C1 C1
RDB-3
RDB-6
RDB-4
RDB-4
RDB-5
4867
RDB-3
4867
16833
RDB-14 RDB-14 RDB-15 RDB-14 RDB-14
C C1 C1 C1 C1 C1 C1
C C1 C1 C1 C1 C1 C1
RDB-6
RDB-4
RDB-3
RDB-3
RDB-4
4867
4867
RB-5
RDS-2 RDS-2 RDS-3 RDS-2 RDS-2
RDB-10
2233
RDB-8
RDB-8
RDB-7
RDB-9
2233
RDB-9
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
ROOF DECK
JUAN PAULO BERSAMINA PROPOSED FOUR-STOREY
S-6
GRANADA, JADE BEAM FRAMING PLAN
BSCE 4C COMMERCIAL BUILDING CHECKED
AND COLUMN
APPROVED LAYOUT
TAGAYTAY CITY, CAVITE OWNER DATE
SEE COLUMN C1 DETAIL SEE COLUMN C1 DETAIL SEE COLUMN C1 DETAIL SEE COLUMN C1 DETAIL
20mm @ 250 C/C 20mm @ 250 C/C 20mm @ 250 C/C 20mm @ 250 C/C
2000
2000
2000
2000
400
400
C1F1 C1F2 C1F3 C1F4
250mm @ REST
1 : 100 MTS
SCALE:
SCALE: 1 : 100 MTS SCALE: 1 : 100 MTS
1 : 100 MTS
1 : 100 MTS
SCALE:
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
DETAILS AND
JUAN PAULO BERSAMINA PROPOSED FOUR-STOREY SCHEDULE OF
S-7
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED COLUMN FOOTINGS
AND COLUMN
APPROVED
C1 DETAIL
TAGAYTAY CITY, CAVITE OWNER DATE
L3
W 3/4
W3
BEAM BEAM
BEAM
W 2/4
TOP BARS BOTTOM BARS
TEMPERATURE BARS
BOTTOM BARS @ MIDSPAN
BEAM
BOTTOM BARS TOP BARS
W 2/4
W2
@ MIDSPAN @ SUPPORT
W 1/4
BEAM
BEAM
TYPICAL DETAILS OF SLABS GROUND FLOOR PLAN SECOND FLOOR PLAN THIRD FLOOR PLAN
SCALE:
SCALE: 1 : 100 MTS SCALE: 1 : 100 MTS 1 : 100 MTS
SCALE: NTS
A B C D E
3S-2 3S-4 3-S2 3-S6
SECTION 1-1
A B C D
L1
L2 L3
1724.8311
1724.8311
1724.8311
1724.8311
19262.0509
19262.0509
19262.0509
4-#10 4-#20 4-#20 4-#20 4-#20 4-#20
2-#20 2-#20 2-#20 2-#20 2-#20 2-#20
4-#20 2-#20 2-#20 4-#20 4-#20 2-#20 2-#20 4-#20 4-#20 2-#20 2-#20 4-#20
9-2L #10
9-2L #10
5-2L #10
10-2L #10
9-2L #10
5-2L #10
10-2L #10
5-2L #10 10-2L #10
10-2L #10
5-2L #10
10-2L #10
5-2L #10
10-2L #10
5-2L #10
@50 C/C @100 C/C @250 C/C @100 C/C @50 C/C @50 C/C @100 C/C @250 C/C @100 C/C @50 C/C @50 C/C @100 C/C @250 C/C @100 C/C @50 C/C
DETAILS OF BEAM
SCALE:
GROUND FLOOR1 PLAN
SCALE: : 100 MTS SECOND FLOOR 1PLAN
SCALE: : 100 MTS THIRD FLOOR
1 : 100 MTS PLAN
SCALE: NTS
4-20mmØ TB 2-16mmØ TB
10mmØ STIRRUPS 1@50 mm
2B 300 500 4@100mm; REST@250mm
3-16mmØ TB 6-16mmØ TB
5-16mmØ TB 2-16mmØ TB
10mmØ STIRRUPS 1@50 mm
3B 300 500 4@100mm; REST@250mm
3-16mmØ TB 6-16mmØ TB
5-16mmØ TB 2-16mmØ TB
300 10mmØ STIRRUPS 1@50 mm
4B 500
4@100mm; REST@250mm
3-16mmØ TB 6-16mmØ TB
5-16mmØ TB 2-16mmØ TB
300 10mmØ STIRRUPS 1@50 mm
4B 500
4@100mm; REST@250mm
3-16mmØ TB 6-16mmØ TB
SCHEDULE OF BEAMS
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
S-9
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED AND SCHEDULE
OF BEAMS
APPROVED
10324.7915
250 mm = 250 mm 10 EQUAL THREADS
10324.7915
10324.7915
250 mm = 250 mm
10 EQUAL THREADS LANDING
250 mm = 250 mm 10 EQUAL THREADS FINISHED FLOOR LINE
250 mm = 250 mm
LANDING
FINISHED FLOOR LINE
12mmØ TRAVERSE BOTTOM BARS
@300mm O.C 12mmØ TRAVERSE BOTTOM BARS
@300mm O.C
12mmØ TRAVERSE BOTTOM BARS
12mmØ TRAVERSE BOTTOM BARS
@300mm O.C
@300mm O.C
13222.1846
10mmØ NOSING BAR 10mmØ BUILT-UP BARS
10 EQUAL THREADS
200 mm = 200 mm
@200mm O.C
13222.1846
10mmØ NOSING BAR 10mmØ BUILT-UP BARS
10 EQUAL THREADS
200 mm = 200 mm
13222.1846
@200mm O.C
10mmØ NOSING BAR 10mmØ BUILT-UP BARS
10 EQUAL THREADS
13222.1846
200 mm = 200 mm
10mmØ NOSING BAR 10mmØ BUILT-UP BARS
10 EQUAL THREADS
@200mm O.C
200 mm = 200 mm
@200mm O.C
8259.8332
8259.8332
12mmØ CUT-BOTTOM BARS
8259.8332
8259.8332
@300mm O.C
12mmØ CUT-BOTTOM BARS
12mmØ CUT-BOTTOM BARS
1032.4792
@300mm O.C
@300mm O.C
1032.4792
825.9833
1032.4792
1032.4792
825.9833
825.9833
825.9833
10mmØ BOT T-BARS
@200mm O.C 10mmØ BOT T-BARS
@200mm O.C
10mmØ BOT T-BARS
@200mm O.C 10mmØ BOT T-BARS FINISHED FLOOR LINE
@200mm O.C
LANDING
FINISHED FLOOR LINE
LANDING
GROUND FLOOR MAIN STAIR PLAN GROUND FLOOR FIRE EXIT STAIR PLAN
SCALE DRAWN NTS SCALE DRAWN NTS
7227.3541
7 EQUAL THREADS
7227.3541
250 mm = 175 mm 7 EQUAL THREADS
LANDING
7227.3541
250 mm = 175 mm
7 EQUAL THREADS 7227.3541
9255.5292
@300mm O.C 10mmØ NOSING BAR
@200mm O.C
9255.5292
10mmØ NOSING BAR 12mmØ CUT-BOTTOM BARS
7 EQUAL THREADS
200 mm = 140 mm
9255.5292
7 EQUAL THREADS
200 mm = 140 mm
9255.5292
@300mm O.C
12mmØ CUT-BOTTOM BARS
5781.8832
7 EQUAL THREADS
1032.4792
200 mm = 140 mm
5781.8832
7 EQUAL THREADS
1032.4792
200 mm = 140 mm
@300mm O.C
5781.8832
825.9833
1032.4792
5781.8832
825.9833
1032.4792
825.9833
825.9833
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
S-10
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED FIRE EXIT
STAIR PLAN
APPROVED
10M
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200
13M
400
400
400
400
400
400
400
400
#20 #20 #20 #20 #20 #20 #20 #20
400 400 400 400 400 400 400 400
7M
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200
10M
400
400
400
400
400
400
400
400
#25 #25 #32
#20 #20 #20 #20 #20 #20 #20 #25
400 400 400 400 400 400 400 400
8-#20 8-#20 8-#20 8-#20 4-#25 + 4-#20 8-#20 4-#25 + 4-#20 4-#32 + 4-#25
C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM
4M
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200
7M
400
400
400
400
400
400
#25 #32 #32 #32 #25 #32
#20 #25 #25 #25 #20 #25
400 400 400 400 400 400
4-#25 + 4-#20 4-#32 + 4-#25 4-#32 + 4-#25 4-#32 + 4-#25 4-#25 + 4-#20 4-#32 + 4-#25
COLUMN MARKED C1 C2 C3 C4 C5 C6 C7 C8
COLUMN SCHEDULE 1
(SCALE 1:25)
NOTES:
1. BE = BOUNDARY ELEMENT AS PER ACI 318. PROVIDE CONFINING REINFORCEMENT ACROSS ENTIRE HEIGHT OF WALL IN THE BOUNDARY ELEMENT
2. Z1 = SPECIAL CONFINING ZONE AS PER ACI 318, Z2 = REMAINING ZONES AS PER ACI 318
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
1
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED COLUMN DESIGN
APPROVED
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200
400
400
400
400
400
400
400
400
#20 #20 #20 #20 #20 #20 #20 #20
400 400 400 400 400 400 400 400
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200
400
400
400
400
400
400
400
400
#25 #32 #32 #32 #32 #32 #32 #25
#20 #25 #25 #25 #25 #25 #25 #20
400 400 400 400 400 400 400 400
4-#25 + 4-#20 4-#32 + 4-#25 4-#32 + 4-#25 4-#32 + 4-#25 4-#32 + 4-#25 4-#32 + 4-#25 4-#32 + 4-#25 4-#25 + 4-#20
COLUMN SCHEDULE 2
(SCALE 1:25)
NOTES:
1. BE = BOUNDARY ELEMENT AS PER ACI 318. PROVIDE CONFINING REINFORCEMENT ACROSS ENTIRE HEIGHT OF WALL IN THE BOUNDARY ELEMENT
2. Z1 = SPECIAL CONFINING ZONE AS PER ACI 318, Z2 = REMAINING ZONES AS PER ACI 318
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
2
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED COLUMN DESIGN
APPROVED
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200
400
400
400
400
400
400
400
400
#20 #20 #20 #20 #20 #20 #20 #20
400 400 400 400 400 400 400 400
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200
400
400
400
400
400
400
400
400
#32 #25 #25 #25 #25 #25
#25 #20 #20 #20 #20 #20 #20 #20
400 400 400 400 400 400 400 400
4-#32 + 4-#25 4-#25 + 4-#20 8-#20 4-#25 + 4-#20 4-#25 + 4-#20 4-#25 + 4-#20 4-#25 + 4-#20 8-#20
C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM C100 : Fy700 , COVER = 40MM
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200 2-T16@100c/c #10 @ 100 #10 @ 200
400
400
400
400
400
400
#32 #32 #32 #32
#25 #20 #25 #25 #25 #25
400 400 400 400 400 400
4-#32 + 4-#25 8-#20 4-#32 + 4-#25 4-#32 + 4-#25 4-#32 + 4-#25 8-#25
COLUMN SCHEDULE 2
(SCALE 1:25)
NOTES:
1. BE = BOUNDARY ELEMENT AS PER ACI 318. PROVIDE CONFINING REINFORCEMENT ACROSS ENTIRE HEIGHT OF WALL IN THE BOUNDARY ELEMENT
2. Z1 = SPECIAL CONFINING ZONE AS PER ACI 318, Z2 = REMAINING ZONES AS PER ACI 318
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
3100 3100
2450 2650 2650 2450
COLUMN LINKS
COLUMN LINKS
3100
2450
2650
2650
2450
3100
4
C1 C2 C3 C4 C5 C6
LD
LD
FC2 FC3 FC4 FC5
FC1 FC6
4867
2950 2950
2950
3
C7 C8 C9 C10 C11 C12
900
900
FC7 FC12
EL. 0.000 EL. 0.000
4867
BOF BOF
2950 2950
#16@125 C/C (T) 150 THK PCC #16@125 C/C (T) 150 THK PCC
2950
2950
2 #16@125 C/C (B) #16@125 C/C (B)
C13 C14 C15 C16 C17 C18
150 3350 150 3350
2
DETAIL OF FOOTING FC24
(SCALE 1:25)
4867
1 1
3100
2800
2650
2650
2750
3350
1
C19 C20 C21 C22 C23 C24
2
#16@125 C/C (T) #16@125 C/C (B)
FC2 C2 Pad - 2450 2450 2800 - #25@105 C/C #25@105 C/C #25@105 C/C #25@105 C/C 1 1
FC3 C3 Pad - 2650 2650 2350 - #25@125 C/C #25@125 C/C #25@125 C/C #25@125 C/C
3350
FC4 C4 Pad - 2650 2650 2350 - #25@125 C/C #25@125 C/C #25@125 C/C #25@125 C/C
FC5 C5 Pad - 2450 2450 2800 - #25@105 C/C #25@105 C/C #25@105 C/C #25@105 C/C
FC6 C6 Pad - 3100 3100 1050 - #16@110 C/C #16@110 C/C #16@110 C/C #16@110 C/C
FC7 C7 Pad - 2950 2950 1875 - #25@160 C/C #25@160 C/C #25@160 C/C #25@160 C/C
FC12 C12 Pad - 2950 2950 1875 - #25@160 C/C #25@160 C/C #25@160 C/C #25@160 C/C
FC13 C13 Pad - 2950 2950 1875 - #25@160 C/C #25@160 C/C #25@160 C/C #25@160 C/C
#16@125 C/C (T)
FC18 C18 Pad - 2950 2950 1875 - #25@160 C/C #25@160 C/C #25@160 C/C #25@160 C/C
FC19 C19 Pad - 3100 3100 1050 - #16@110 C/C #16@110 C/C #16@110 C/C #16@110 C/C
FC20 C20 Pad - 2800 2800 2150 - #25@135 C/C #25@135 C/C #25@135 C/C #25@135 C/C
FC21 C21 Pad - 2650 2650 2350 - #25@125 C/C #25@125 C/C #25@125 C/C #25@125 C/C
FC22 C22 Pad - 2650 2650 2350 - #25@125 C/C #25@125 C/C #25@125 C/C #25@125 C/C
3350
150 THK PCC
FC23 C23 Pad - 2750 2750 2225 - #25@135 C/C #25@135 C/C #25@135 C/C #25@135 C/C
FC24 C24 Pad - 3350 3350 900 - #16@125 C/C #16@125 C/C #16@125 C/C #16@125 C/C
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
4
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED FOOTING DESIGN
APPROVED
B1 B2 B3 B4 B5 B1 B2 B3 B4 B5
4 #10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
C1 C2 C3 C4 C5 C6
4
C1 C2 C3 C4 C5 C6
1130
1130
1130
1130
1130
#10@225 C/C #10@225 C/C #10@225 C/C #10@225 C/C #10@225 C/C
#10@175 C/C #10@160 C/C #10@170 C/C #10@160 C/C #10@175 C/C
1130 1130 1130 1130 1130 1130 1130 1130 1130 1130
(ALT.CURTAIL)
(ALT.CURTAIL)
#10@225 C/C
#13@155 C/C
#13@155 C/C
#13@155 C/C
#13@155 C/C
#10@225 C/C
#10@250 C/C
#10@195 C/C
#10@220 C/C
#10@195 C/C
#10@250 C/C
S1 S2 S3 S4 S5 S1 S2 S3 S4 S5
4867
4867
B23
B26
B29
B32
B35
B38
B23
B26
B29
B32
B35
B38
945 945 945 945
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C (200THK) (200THK) (200THK) (200THK) (200THK)
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@120 C/C #10@110 C/C #10@115 C/C #10@110 C/C #10@120 C/C
1130
1130
1130
1130
1130
B6 B7 B8 B9 B10 B6 B7 B8 B9 B10
3
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
C7 C8 C9 C10 C11 C12
3
C7 C8 C9 C10 C11 C12
1130
1130
1130
1130
1130
#10@270 C/C #10@250 C/C #10@265 C/C #10@250 C/C #10@270 C/C
1130 1130 1130 1130 1130 1130 1130 1130 1130 1130
(ALT.CURTAIL)
(ALT.CURTAIL)
#10@225 C/C
#13@145 C/C
#13@145 C/C
#13@145 C/C
#13@145 C/C
#10@225 C/C
#10@240 C/C
#10@180 C/C
#10@210 C/C
#10@180 C/C
#10@240 C/C
S6 S7 S8 S9 S10 S6 S7 S8 S9 S10
4867
4867
B22
B25
B28
B31
B34
B37
B22
B25
B28
B31
B34
B37
945 945 945 945
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C (200THK) (200THK) (200THK) (200THK) (200THK)
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@125 C/C #10@110 C/C #10@115 C/C #10@110 C/C #10@125 C/C
1130
1130
1130
1130
1130
B11 B12 B13 B14 B15 B11 B12 B13 B14 B15
2
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
C13 C14 C15 C16 C17 C18
2
C13 C14 C15 C16 C17 C18
1130
1130
1130
1130
1130
#10@175 C/C #10@160 C/C #10@170 C/C #10@160 C/C #10@175 C/C
1130 1130 1130 1130 1130 1130 1130 1130 1130 1130
(ALT.CURTAIL)
(ALT.CURTAIL)
#10@225 C/C
#13@155 C/C
#13@155 C/C
#13@155 C/C
#13@155 C/C
#10@225 C/C
#10@250 C/C
#10@195 C/C
#10@220 C/C
#10@195 C/C
#10@250 C/C
S11 S12 S13 S14 S15 S11 S12 S13 S14 S15
4867
4867
B21
B24
B27
B30
B33
B36
B21
B24
B27
B30
B33
B36
945 945 945 945
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C
#10@225 C/C (200THK) #10@225 C/C (200THK) (200THK) (200THK) (200THK) (200THK)
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C
#10@225 C/C #10@225 C/C #10@225 C/C #10@225 C/C #10@225 C/C
1130
1130
1130
1130
1130
B16 B17 B18 B19 B20 B16 B17 B18 B19 B20
1 1
C19 C20 C21 C22 C23 C24 C19 C20 C21 C22 C23 C24
SLAB SLAB ALONG SHORT SPAN ALONG LONG SPAN OVER LONG SUPPORT OVER SHORT SUPPORT
MARKED THICKNESS DISTRIBUTION
FULL LENGTH CURTAILED FULL LENGTH CURTAILED CONTINUOUS END CONTINUOUS END
SUPPORT SUPPORT SUPPORT SUPPORT
S1, S5 200 #10 @ 175 C/C --- #10 @ 250 C/C #10 @ 250 C/C #10 @ 120 C/C #10 @ 225 C/C #13 @ 155 C/C #10 @ 225 C/C #10 @ 225 C/C
S2, S4, S12 200 #10 @ 160 C/C --- #10 @ 195 C/C --- #10 @ 110 C/C #10 @ 225 C/C #13 @ 155 C/C #10 @ 225 C/C #10 @ 225 C/C
S14
S3, S13 200 #10 @ 170 C/C --- #10 @ 220 C/C --- #10 @ 115 C/C #10 @ 225 C/C #13 @ 175 C/C #10 @ 225 C/C #10 @ 225 C/C
S6, S10 200 #10 @ 270 C/C --- #10 @ 240 C/C #10 @ 240 C/C #10 @ 125 C/C --- #13 @ 145 C/C #10 @ 225 C/C #10 @ 225 C/C
S7, S9 200 #10 @ 250 C/C --- #10 @ 180 C/C --- #10 @ 110 C/C --- #13 @ 145 C/C --- #10 @ 225 C/C
S8 200 #10 @ 265 C/C --- #10 @ 210 C/C --- #10 @ 115 C/C --- #13 @ 165 C/C --- #10 @ 225 C/C
S11, S15 200 #10 @ 175 C/C --- #10 @ 250 C/C #10 @ 250 C/C #10 @ 125 C/C #10 @ 225 C/C #13 @ 160 C/C #10 @ 225 C/C #10 @ 225 C/C
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
B1 B2 B3 B4 B5
4
C1 C2 C3 C4 C5 C6
4867
B23
B26
B29
B32
B35
B38
BEAM SCHEDULE (C35:Fy420) (LEVEL: 10m)
B1 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 32-2L-#13@135 C/C 7-2L-#13@100 C/C
B2 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
4867
B3 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 29-2L-#13@135 C/C 7-2L-#13@100 C/C
B22
B25
B28
B31
B34
B37
B4 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B5 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 32-2L-#13@135 C/C 7-2L-#13@100 C/C
B11 B12 B13 B14 B15 B6 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#13@100 C/C 32-2L-#13@135 C/C 7-2L-#13@100 C/C
2
C13 C14 C15 C16 C17 C18 B7 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#13@100 C/C 32-2L-#13@135 C/C 7-2L-#13@100 C/C
B8 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#10@100 C/C 29-2L-#10@135 C/C 7-2L-#10@100 C/C
B9 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#13@100 C/C 32-2L-#13@135 C/C 7-2L-#13@100 C/C
4867
B21
B24
B27
B30
B33
B36
B10 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#13@100 C/C 32-2L-#13@135 C/C 7-2L-#13@100 C/C
B11 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B12 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B16 B17 B18 B19 B20 B13 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#10@100 C/C 29-2L-#10@135 C/C 7-2L-#10@100 C/C
1
C19 C20 C21 C22 C23 C24 B14 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B15 350 300 3-#16 3-#16 3-#16 4-#16 4-#16 4-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B16 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B17 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B18 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 29-2L-#10@135 C/C 7-2L-#10@100 C/C
B19 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B20 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 32-2L-#10@135 C/C 7-2L-#10@100 C/C
B21 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
B22 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
B23 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
350 350 350 B24 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
B25 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
3-#16 3-#16 3-#16
B26 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
300
300
300
STP 2L-#10 STP 2L-#10 STP 2L-#10
3-#16 3-#16 3-#16 B27 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
B36 B37 B38 B28 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 24-2L-#10@135 C/C 7-2L-#10@100 C/C
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
B29 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 24-2L-#10@135 C/C 7-2L-#10@100 C/C
B30 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
B31 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
B32 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#13@100 C/C 24-2L-#13@135 C/C 7-2L-#13@100 C/C
B33 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 24-2L-#10@135 C/C 7-2L-#10@100 C/C
B34 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 24-2L-#10@135 C/C 7-2L-#10@100 C/C
B35 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 24-2L-#10@135 C/C 7-2L-#10@100 C/C
B36 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 24-2L-#10@135 C/C 7-2L-#10@100 C/C
B37 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 24-2L-#10@135 C/C 7-2L-#10@100 C/C
B38 350 300 3-#16 3-#16 3-#16 3-#16 3-#16 3-#16 7-2L-#10@100 C/C 24-2L-#10@135 C/C 7-2L-#10@100 C/C
858.6(ANCHORAGE)
858.6(ANCHORAGE)
1 2 3 4
400 400 400 400
4867 4867 4867
3-#16
858.6(ANCHORAGE)
858.6(ANCHORAGE)
3-#16
C24
B36:350x300 C18
B37:350x300 C12
B38:350x300 C6
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
CIVIL ENGINEER PROJECT TITLE / LOCATION APPROVED BY: DESIGNED ENGRDC REVISION DATE SHEET CONTENT/S SHEET NUMBER
6
GRANADA, JADE
BSCE 4C COMMERCIAL BUILDING CHECKED BEAM DESIGN
APPROVED
MATERIAL PROPERTY
CONCRETE
𝑓𝑐′ = 21 𝑀𝑃𝑎
𝛾 = 23.6 𝑘𝑁/𝑚3
STEEL
𝐹𝑦 = 420 𝑀𝑃𝑎 FOR BEAM AND COLUMN DESIGN
𝐹𝑦 = 276 𝑀𝑃𝑎 FOR SLAB AND FOOTING DESIGN
DEAD LOAD
SLABS
CONCRETE (SELF WEIGHT) 23.6 kN/m3
INTERIOR PARTITION WALL 1.00 kPa
ACOUSTICAL FIBER BOARD 0.050 kPa
SUSPENDED STEEL CHANNEL SYSTEM 0.100 kPa
CERAMIC OR QUARRY TILE (20 mm)
ON 25 mm MORTAR BED 1.100 kPa
ELECTROMECHANICAL 0.100 kPa
BITUMINOUS SMOOTH SURFACE 0.070 kPa
BEAMS, COLUMNS AND MAIN STAIRS
CONCRETE (SELF WEIGHT) 23.6 kN/m3
BITUMINOUS SMOOTH SURFACE 0.070 kPa
WALLS
EXTERIOR WALL (16.5-kN/m3 Density of Unit)
FULL GROUT (EACH FACE PLASTERED) 4.07 kPa
INTERIOR PARTITION WALL 1.00 kPa
GLASS WALLS, RAILINGS 0.38 kPa
OTHER STAIRS
FIRE EXIT STEEL STAIRS 77.3 kN/m3
LIVE LOAD
BUSINESS/OFFICE UNIT 2.90 kPa
LOBBIES/PATHWAY 4.80 kPa
RESTROOMS 2.40 kPa
EXIT FACILITIES 4.80 kPa
ROOF DECK LIVE LOAD 2.40 kPa
Emilio Aguinaldo Highway, East, Silang Junction South, Tagaytay City, 4120 Cavite
Interpolation Method fo Nv
𝒙 −𝟐. 𝟐
= = 𝟎. 𝟎𝟖𝟖
𝟎. 𝟐 −𝟓
Nv @ 12.2 = 1.2 - x
= 1.2 - 0.088
Nv = 1.112
Computation of T:
Ct (under normal conditions) = 0.0731
hn (total bldg height) = 16 m
T = Ct(hn)¾
T = 0.0731 x 163/4
T = 0.5848
Structural Member Unit Weight length width height Qty Weight (kN)
BUILDING TOTAL
15017.803 kN
WEIGHT (WT):
Zone 4
hn = 16 m
Ct = 0.0731
Na = 1
Nv = 1.112
Ca = 0.44
Cv = 0.71168
I= 1
R= 8.5
T= 0.5848
3rd floor 4584.09938 3.2 14669.11801 0.32404 1943.48040 0.324 x 1943.480 = 629.77271
4th floor 4168.73938 3.2 13339.96601 0.29468 1943.48040 0.295 x 1943.480 = 572.70973
roof deck 2553.740 2.4 6128.97494 0.13539 1943.48040 0.135 x 1943.480 = 263.12837
PROPERTIES
MATERIALS
SUPPORTS
LOADING: REFERENCE LOAD COMBINATIONS
DL1:
SELFWEIGHT - FACTOR = - 1 (WEIGHT OF COLUMNS, BEAMS,
AND PLATES)
DL2:
SUPERIMPOSED DEAD LOAD
TWO-WAY SLAB
LOAD PRESSURE
INTERIOR PARTITION WALLS 1.00 kPa
TOTAL 3.325
LOAD PRESSURE
SUSPENDED METAL LATH 0.48 kPa
AND GYPSUM PLASTER
TOTAL 1.225
LOADING: LOAD CASES DETAILS
EX
EZ
LL1
LL2
BUSINESS/OFFICE UNIT (PB) 2.90 kPa
LOBBIES/PATHWAY (PL) 4.80 kPa
RESTROOMS (PR) 2.40 kPa
EXIT FACILITIES (PEF) 4.80 kPa
ANALYSIS
CHECKING FOR THE INTERACTION DIAGRAM OF C24 GIVEN THIS CROSS SECTION
C24 (Cross-section)
x = 60 mm
ρ = 0.002%
BASED ON THE STAAD RESULTS, THE FORCES OF C24 ARE AS FOLLOWS
Fx = 2112.5871 kN
My = 18568.514 kN - m
Mz = 18912.678 kN - m
10000
8000
6000
4000
2000
0
-600 -400 -200 0 200 400 600 800 1000
-2000
INTERACTION SURFACE
SINCE THE CROSS SECTION AND REINFORCEMENT DETAILING
CAN CARRY THE LOAD
APPLIED TO IT, THE COMPUTATION FOR TIES WILL BE AS FOLLOWS
CASE 1:
Smax-1 = 16db
Smax-1 = 16(20 mm)
Smax-1 = 320 mm
CASE 2:
Smax-2 = 48dbt
Smax-2 = 48(10mm)
Smax-2 = 480 mm
CASE 3:
LEAST COLUMN DIMENSION
Smax-3 = 400 mm
Smax
16db 320 mm
48dbt 480 mm
LEAST COLUMN DIM. 400 mm
USE Smax 320 mm
FOR THE SPACING FOR S1
CASE 1:
S1-1 = 0.25bmin
S1-1 = 0.25(400)
S1-1 = 100 mm
CASE 2:
S1-2 = 6db
S1-2 = 6(20 mm)
S1-2 = 120 mm
CASE 3:
S1-3 = 100 mm
CASE 1:
LEAST COLUMN DIMENSION
Io-1 = 400 mm
CASE 2:
ℎ𝑡
Io-2 = 6
5500𝑚𝑚
Io-2 = 6
CASE 3:
Io-3 = 400 mm
USING
Io = 917 mm
BASED ON THE REACTIONS ON STAAD THE NODE WITH THE MAXIMUM AXIAL LOAD
APPLIED ON FOOTING NODE 11
SIDE OF FOOTING (s or B or L) 8m
COMPUTING FOR NET UPWARD PRESSURE
𝐹𝑦
ρO = 𝐴𝑟𝑒𝑞′𝑑
1160.687 𝑘𝑁
ρO = (2.828𝑚)2
M1 = 353.8897 kN-m
M1-u = 1.5 M1
M1-u = 1.5 (353.8897 kN-m)
M1-u = 530.8346 kN-m
1160.687 6(234.332)
𝜎= 2
+
3𝑚 (3 𝑚)(3 𝑚)2
𝜎 = 438.96 𝑘𝑁/𝑚2
RN = 0.8426
0.85f′c 2𝑅
ρreq'd = [1 − √1 − 0.85 𝑁𝑓′𝑐]
𝐹𝑦
0.85(21) 2(0.8426)
ρreq'd = [1 − √1 − ]
(420) 0.85(21)
ρreq'd = 0.00205
Asrq’d = ρbd
Asrq’d = (0.00205)(3000 mm)(450 mm)
Asrq’d = 2775.488621 mm2
0.85(21)(0.85) 3
ρmax = (8)
420
ρmax = 0.01355
Asmax = ρbd
Asmax = (0.01355)(3000mm)(450mm)
Asmax = 18292.50 mm2
1.4
ρmin = 𝐹𝑦
1.4
ρmin = 420
ρmin = 0.00333
√𝑓𝑐′
ρmin = 4𝐹𝑦
√21
ρmin = 4(420)
ρmin = 0.00273
Asmin = ρbd
Asmin = (0.00273)(3000mm)(450mm)
Asmin = 3685.50 mm2
MINIMUM STEEL RATIO (ρmin) 0.00333
MINIMUM STEEL AREA (Asmin) 3685.50 mm2
SINCE
Asmax > Asrq’d < Asmin
As = Asmin
As = 3685.50 mm2
3685.50 𝑚𝑚2
n= 𝜋
( ) (20 𝑚𝑚2 )
4
SPACING TO BE COMPUTED
𝐵
S= 𝑛+1
3000
S= 12+1
S=230.769 mm ≈ 230 mm
1
SLAB
DESIGN
2
MANUAL COMPUTATION
counter check for one way slab
𝑑𝑖𝑎𝑚𝑎𝑖𝑛 𝑏𝑎𝑟
d = t - concrete cover - 2
10
d = 150 - 20 - 2
d = 125 mm
SINCE THE SLAB IS FIXED ON BOTH ENDS THE MAXIMUM MOMENT AT THE MIDSPAN
AND AT THE SUPPORT IS STATED ON THE FIGURE BELOW
𝑀
RN = 0.9𝑏𝑑2
1693500 𝑁/𝑚𝑚
RN = 0.9(1000𝑚𝑚)(125𝑚𝑚)2
RN = 0.12042667
0.85 𝑓′𝑐 2𝑅
ρreq’d = [1 − √1 − 0.85 𝑁𝑓′𝑐]
𝐹𝑦
ρreq’d = 0.0004378104
Asreq’d = ρbd
Asreq’d = (0.0004378104)(1000mm)(125mm)
Asreq’d = 54.7263 mm2
4
BASED ON THE NSCP THE MAXIMUM AND MINIMUN STEEL AREA SHOULD BE
CONSIDERED IN DESIGNING
0.85𝑓′𝑐𝛽 3
ρmax = (8)
𝐹𝑦
0.85(21)(0.85) 3
ρmax = (8)
276
ρmax = 0.02061
Asmax = ρbd
Asmax = (0.02061)(1000mm)(125mm)
Asmax = 2576.25 mm2
1.4
ρmin = 𝐹𝑦
1.4
ρmin = 276
ρmin = 0.00507
√21
ρmin = 276
ρmin = 0.00415
SINCE
Asmin > Asreq’d < Asmax
As = Asmin = 518.75 mm2
1000 𝑆𝑂𝐶
=𝜋
518.75 mm2 (10𝑚𝑚)2
4
Smax-1 = 3t = 3(150mm)
Smax-1 = 450 mm
SINCE
𝑆𝑂𝐶 < Smax-1
S = 𝑆𝑂𝐶 = 150 mm
𝑀
RN = 0.9𝑏𝑑2
2540250 𝑁/𝑚𝑚
RN = 0.9(1000𝑚𝑚)(125𝑚𝑚)2
RN = 0.18064
0.85 𝑓′𝑐 2𝑅
ρreq’d = [1 − √1 − 0.85 𝑁𝑓′𝑐]
𝐹𝑦
ρreq’d = 0.000657838
Asreq’d = ρbd
Asreq’d = (0.000657838)(1000mm)(125mm)
Asreq’d = 82.2298 mm2
SINCE
Asmin > Asreq’d < Asmax
As = Asmin = 518.75 mm2
1000 𝑆𝑂𝐶
=𝜋
518.75 mm2 (10𝑚𝑚)2
4
SINCE
𝑆𝑂𝐶 < Smax-1
S = 𝑆𝑂𝐶 = 150 mm
AS = 0.002Ag
AS = 0.002(150mm)(1000mm)
AS = 300 mm2
1000 𝑆
= 𝐴 𝑂𝐶
𝐴𝑆 𝑏𝑎𝑟
1000 𝑆𝑂𝐶
=𝜋
300 mm2 (10𝑚𝑚)2
4
Smax-1 = 5t = 5(150mm)
Smax-1 = 750 mm
SINCE
𝑆𝑂𝐶 < Smax-1
S = 𝑆𝑂𝐶 = 260 mm
MANUAL COMPUTATION
(counter check for the beam with the maximum moment)
BASED ON THE BEAM RESULTS ON STAAD THE VALUE OF THE MAXIMUM MOMENT
OCCURED ON BEAM 49
𝑑𝑖𝑎𝑚𝑎𝑖𝑛𝑏𝑎𝑟
d = h - concrete cover - diastirrups - 2
20
d = 350 - 20 -10 - 2
𝑀
RN = 0.9𝑏𝑑2
116068700 𝑁−𝑚𝑚
RN = 0.9(300𝑚𝑚)(310𝑚𝑚)2
RN = 4.4732
0.85 𝑓𝑐′ 2𝑅
ρreq’d = [1 − √1 − 0.85 𝑁𝑓𝑐′]
𝐹𝑦
ρreq’d = 0.01248
Asreq’d = ρbd
Asreq’d = (0.01248)(300 mm)(310 mm)
Asreq’d = 1161.013 mm2
0.85 𝑓𝑐′β 3
ρmax = (8)
𝐹𝑦
0.85(21)(0.85) 3
ρmax = (8)
420
ρmax = 0.01355
Asmax = ρbd
Asmax = (0.01355)(300mm)(310 mm)
Asmax = 1260.15 mm2
1.4
ρmin = 𝐹𝑦
1.4
ρmin = 420
ρmin = 0.00333
√𝑓𝑐′
ρmin = 4𝐹𝑦
√21
ρmin = 4(452)
ρmin = 0.00273
Asmin = ρbd
Asmin = (0.00333)(300 mm)(310 mm)
Asmin = 309.69 mm2 ≅ 310 mm2
SINCE
Asmax > Asreq’d > Asmin
As = Asmin
As = 310 mm2
1161.013 mm2
n= 𝜋
( )(20𝑚𝑚2 )
4
n ≅ 4 pcs
n = 4pcs of 20 mm diameter bars