Acme FS Finger Guard Industrial Control Transformer Spec
Acme FS Finger Guard Industrial Control Transformer Spec
Acme FS Finger Guard Industrial Control Transformer Spec
■ 50 VA through 3000 VA sizes, 50/60 Hz. The Directives that apply to Control or Power Distribution Transformers are:
Low Voltage Directive, 73/23/EEC effective January 1, 1997
■ 130°C (Class B) Insulation 80°C
temperature rise. Electromagnetic Compatibility (EMC) Directive, 89/336/EEC effective
January 1, 1996
■ Voltage regulation exceeds NEMA
requirements. The stringent testing required to obtain a third party certification mark in many
cases is significantly more rigid than domestic requirements. This ensures that
■ UL Listed, CSA Certified and
not only the Acme FINGER/GUARD® product, but all of our CE
CE Marked.
Marked products are designed to meet a higher level of safety
■ Attractive finish, nameplate, and design standards than non-CE Marked products.
features enhance the end product.
All Acme transformers are manufactured in a facility
■ Ten-year limited warranty. certified by Underwriters Laboratories to ISO-9001.
■ Smaller, lighter weight design.
GROUP A
120 X 240 PRIMARY VOLTS — 24 SECONDARY VOLTS — 50/60 Hz
APPROX. DIMENSIONS INCHES (CM.)
CATALOG VA EUROPEAN* APPROX.
NO. RATING RATING A B C D E F SHIP WEIGHT LBS. (Kg.)
FS-1-50
FS-1-75
FS-1-100
FS-1-150 Reference Group IC (CE01):
FS-1-250 CE Series Industrial Control Transformers
FS-1-350
50-750 VA
See Pg 84
FS-1-500
FS-1-750
FS-1-1000 1000 870 4.76 (12.1) 6.75 (17.1) 6.03 (15.3) 5.75 (14.6) 2.86 (7.3) .31 x .50 (0.8 x 1.3) 26 (11.8)
GROUP B
240 X 480, 230 X 460, 220 X 440 PRIMARY VOLTS — 120/115/110 SECONDARY VOLTS — 50/60 Hz
APPROX. DIMENSIONS INCHES (CM.)
CATALOG VA EUROPEAN* APPROX.
NO. RATING RATING A B C D E F SHIP WEIGHT LBS. (Kg.)
FS-2-50
FS-2-75
FS-2-100
FS-2-150 Reference Group VIC (CE06):
FS-2-250 CE Series Industrial Control Transformers
FS-2-300 50-750 VA
FS-2-350 See Pg 85
FS-2-500
FS-2-750
FS-2-1000 1000 870 4.76 (12.1) 6.75 (17.1) 6.03 (15.3) 5.75 (14.6) 2.86 (7.3) .31 x .50 (0.8 x 1.3) 26 (11.8)
FS-2-1500 1500 1290 6.01 (15.3) 6.75 (17.1) 6.03 (15.3) 5.75 (14.6) 4.13 (10.5) .31 x .50 (0.8 x 1.3) 38 (17.2)
FS-2-2000 2000 1680 6.51 (16.5) 6.75 (17.1) 6.03 (15.3) 5.75 (14.6) 4.63 (11.8) .31 x .50 (0.8 x 1.3) 44 (20.0)
FS-2-3000 3000 2465 7.44 (18.9) 7.50 (19.1) 6.68 (17.0) 6.50 (16.5) 6.47 (16.4) .41 x .81 (1.0 x 2.1) 60 (27.2)
GROUP C
240/416/480/600; 230/400/460/575; 220/380/440/550; 208/500 PRIMARY VOLTS
99/120/130; 95/115/125; 91/110/120; 85/100/110 SECONDARY VOLTS — 50/60 Hz
APPROX. DIMENSIONS INCHES (CM.)
CATALOG VA EUROPEAN* APPROX.
NO. RATING RATING A B C D E F SHIP WEIGHT LBS. (Kg.)
FS-3-50 50 50 2.59 (6.6) 3.75 (9.5) 3.64 (9.2) 3.13 (8.0) 1.70 (4.3) .22 x .50 (0.6 x 1.3) 5 (2.3)
FS-3-150 150 150 3.31 (8.4) 4.50 (11.4) 4.15 (10.5) 3.75 (9.5) 2.18 (5.5) .22 x .50 (0.6 x 1.3) 8 (3.6)
FS-3-250 250 250 3.61 (9.2) 4.88 (12.4) 4.46 (11.3) 4.06 (10.3) 2.33 (5.9) .22 x .50 (0.6 x 1.3) 11 (5.0)
FS-3-350 350 345 4.69 (11.9) 4.88 (12.4) 4.46 (11.3) 4.06 (10.3) 3.48 (8.8) .22 x .50 (0.6 x 1.3) 17 (7.7)
FS-3-500 500 490 4.39 (11.2) 6.75 (17.1) 6.03 (15.3) 5.75 (14.6) 2.48 (6.3) .31 x .50 (0.8 x 1.3) 22 (10.0)
FS-3-750 750 720 5.18 (13.2) 6.75 (17.1) 6.03 (15.3) 5.75 (14.6) 3.31 (8.4) .31 x .50 (0.8 x 1.3) 30 (13.6)
FS-3-1000 1000 870 6.18 (15.7) 6.75 (17.1) 6.03 (15.3) 5.75 (14.6) 4.30 (10.9) .31 x .50 (0.8 x 1.3) 39 (17.7)
FS-3-1500 1500 1290 6.26 (15.9) 7.50 (19.1) 6.68 (17.0) 6.50 (16.5) 5.26 (13.4) .41 x .81 (1.0 x 2.1) 51 (23.1)
FS-3-2000 2000 1680 7.76 (19.7) 7.50 (19.1) 7.70 (19.6) 6.50 (16.5) 6.75 (17.1) .41 x .81 (1.0 x 2.1) 66 (29.9)
FS-3-3000 3000 2465 8.88 (22.6) 11.92 (30.3) 8.83 (22.4) 6.75 (17.1) 5.75 (14.6) .41 x .81 (1.0 x 2.1) 70 (31.8)
®
FUSE KITS–FOR FINGER/GUARD INDUSTRIAL CONTROL TRANSFORMERS
CATALOG NO. DESCRIPTION
PL-79905 PRIMARY FUSE KIT FOR CLASS CC FUSES
PL-79906 PRIMARY & SECONDARY FUSE KIT FOR CLASS CC PRIMARY FUSES & MIDGET SECONDARY FUSE
PL-79907 PRIMARY FUSE KIT FOR MIDGET FUSES
PL-79908 PRIMARY & SECONDARY FUSE KIT FOR MIDGET FUSES
* EN60742 requires transformers to pass the temperature rise limits of a 130° C (Class B) insulation system at 6% above the rated supply voltage.
99V
95
120V 91
120V 115 85
24V 115
110 130V 110
X2 X1 125 100
X2 X1 120
110
X4 X3 X2 X1
50 VA Thru 2 KVA
A
E
F
B C
D
3 KVA
A
C
F
D
B
E