Security Expert Security Purpose Output Expansion

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

[ SP-O8 ] Security Expert

Security Expert Security Purpose Output Expansion

The Security Expert Security Purpose Output Expansion


provides the control of 8 high current Form C relay outputs.
It provides extensive hardware advancements that provide
flexible access control, area control and alarm monitoring.
This device is designed for use with industry standard DIN
Rail mounting.

Feature Highlights Connectivity and System Expansion


 8 Form C relays capable of switching resistive loads up to 7 Expanding the Security Expert System with outputs from the
Amps Output Expansion allows convenient, cost effective expansion and
added benefit of:
 Ideal for connection in an electrical switch room to control
signage, lighting and building automation  8 multi-function outputs for use in any programmable output
entry
 LED indicators to show state of all onboard relays
 Ideal for connection in an electrical switch room to control
 High performance 32 Bit processor signage, lighting and building automation
 Address configuration of the Output Expansion is achieved
 Secure encrypted RS-485 module communications
using the address programming feature of the Security Expert
 Online and remote upgradable firmware System Controller
 Outputs can be configured to automatically turn on when
 Designed for use with industry standard DIN Rail mounting
powered up, communication failure, or to resume previous
state
Power Supply
Device power is supplied from a 12VDC input. Ultra low current Communication
requirements ensure cost effective power distribution.
Single RS-485 communication interface port used for all network
communication functions and interconnection to other modules.

Upgradable Firmware
Utilizing the latest flash technology and high performance
communication mediums, the firmware can be updated using the
Loadit utility over the system module network.

Schneider Electric | Building Business www.schneider-electric.com/buildings April 2018


Trademarks and registered trademarks are the property of their respective owners.
[ SP-O8 ] Security Expert
2

Technical Specifications
Power Supply

DC Input Voltage 11-14VDC


DC Output Voltage 10.83-14.0VDC 0.7A (Typical) Electronic Shutdown at 1.1A
(DC IN Pass-Through)

Operating Current 80mA (Typical)

Total Combined Current* 3.25A (Max)


Low Voltage Cutout 8.7VDC

Low Voltage Restore 10.5VDC


Communication

RS-485 Module Network

Outputs
PGM Outputs 8 Form C relays - 7A N.O./N.C. at 30 VAC/DC resistive/inductive
Dimensions
Dimensions (L x W x H) 156.8 x 90 x 60mm (6.17 x 3.54 x 2.36")

Weight 482g (17oz)


Temperature
Operating 0˚-50˚C (32˚ - 122˚F)

Storage -10˚- 85˚C (14˚ - 185˚F)


Humidity 0%-93% non-condensing, indoor use only (relative humidity)

* The Total Combined Current refers to the current that will be drawn from the external power supply to supply the Output Expansion and any
devices connected to the Expander's outputs. The Auxiliary outputs are directly connected via electronic fuses to the N+ N- input terminals, and
the maximum current is governed by the trip level of these fuses.

Ordering Information
SP-O8 Security Expert Security Purpose Output Expansion

Schneider Electric | Building Business www.schneider-electric.com/buildings April 2018


Trademarks and registered trademarks are the property of their respective owners.
[ SP-O8 ] Security Expert
3

Regulatory Notices
Federal Communications Commission (FCC) CE – Compliance with European Union (EU)
FCC Rules and Regulations CFR 47, Part 15, Class A. Conforms to European Union (EU) Low Voltage Directive (LVD)
2014/35/EU, Electro-Magnetic Compatibility (EMC) Directive
This equipment complies with the limits for a Class A digital
2014/30/EU and RoHS Recast (RoHS2) Directive: 2011/65/EU.
device, pursuant to Part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) This device may not cause This equipment complies with the rules of the Official Journal of
harmful interference; (2) This device must accept any interference the European Union for governing the Self Declaration of the CE
received, including interference that may cause undesired Marking for the European Union as specified in the above
operation. directive(s).

Industry Canada UL/ULC (Underwriters Laboratories)


ICES-003  UL 294 for Access Control System Units
This is a Class A digital device that meets all requirements of the  UL1610 for Central-Station Burglar-Alarm Units
Canadian Interference-Causing Equipment Regulations.  CAN/ULC S319 for Electronic Access Control Systems
CAN ICES-3 (A)/NMB-3(A)  CAN-ULC S304 for Signal Receiving Centre And Premise
Burglar Alarm Control Units
RCM (Australian Communications and Media Authority  CAN/ULC S559 for Fire Signal Receiving Centres And
(ACMA)) Systems
This equipment carries the RCM label and complies with EMC and
radio communications regulations of the Australian
Communications and Media Authority (ACMA) governing the
Australian and New Zealand (AS/NZS) communities.

Schneider Electric | Building Business www.schneider-electric.com/buildings April 2018


Trademarks and registered trademarks are the property of their respective owners.