ABSTRACT
The efficiency of any power system is estimated by the losses that occur in
its generating transmitting and distributing equipment. As efficiency is the main criteria,
measures are taken to reduce losses and improve the efficiency. However, there are losses
which are sometimes advantageous and which are not eliminated completely for these
power conductors. This phenomena when occurs, creates power loss in the power
system. Though there are many disadvantages in the occurrence of corona, due to
its advantages of protecting the power system, no attempts are made to eliminate it
completely. However, only few measures to reduce it to some optimum value are
employed.
CORONA :
It is caused by the electric field next to an object, exceeding breakdown value for air. It is
self-sustaining electric discharge in which the field intensified ionization is localized only
Free electrons are present in free space because of radio activity and cosmic
rays. As potential between the conductors is increased, the gradient around the surface of
the conductor increases.The free electrons will move with certain velocity, depending on
field strength.These electrons will collide with molecules of air,thereby releasing more
on surface of the object reduce the corona starting voltage, probably by providing local
The ions produced by electric field result in space charges which move
round the conductor. This energy is derived from supply system. In order to maintain
from supply referred to as corona loss. Peek made experiments to study the effect of
various parameters on the corona loss and gave the following empirical relation.
Also a small error in m o, the irregularity factor, will lead to wrong results when using
this formula.
FACTORS AFFECTING CORONA:
1) Electrical factors:
2) Atmospheric factors:
Vo=21.1mo&oln(d/r) KV
Where &o= air density correction factor, lower the value of &, higher is
b) Dust, rain, snow and hail effect: The presence and occurance of these bad
the effect of second proportionality is much more than the first. Therefore,
c) Profile of conductor.
d) Surface conditions.
DISADVANTAGES:
effects.
ADVANTAGES:
It reduces the magnitude of high voltage steep fronted waves due to lightning
or switching by partially dissipating a corona loss. In this way, it acts as a safety valve
to some extent.
Thus as it is seen, there are also losses which need not be totally eliminated in a
power system. As this phenomenon works as a safety valve which protects the equipment
from lightening effects, this effect is maintained to some optimum value using the
BIBILOGRAPHY
1) Electrical power systems --------------------- C.L.Wadhwa